Records |
Author |
Verbeeck, J.; Hébert; Rubino, S.; Novák, P.; Rusz, J.; Houdellier, F.; Gatel, C.; Schattschneider, P. |
Title |
Optimal aperture sizes and positions for EMCD experiments |
Type |
A1 Journal article |
Year |
2008 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
108 |
Issue |
9 |
Pages |
865-872 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The signal-to-noise ratio (SNR) in energy-loss magnetic chiral dichroism (EMCD)the equivalent of X-ray magnetic circular dichroism (XMCD) in the electron microscopeis optimized with respect to the detector shape, size and position. We show that an important increase in SNR over previous experiments can be obtained when taking much larger detector sizes. We determine the ideal shape of the detector but also show that round apertures are a good compromise if placed in their optimal position. We develop the theory for a simple analytical description of the EMCD experiment and then apply it to dynamical multibeam Bloch wave calculations and to an experimental data set. In all cases it is shown that a significant and welcome improvement of the SNR is possible. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000258747600009 |
Publication Date |
2008-03-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
27 |
Open Access |
|
Notes |
This work was supported by the European Commission under contract no. 508971 CHIRALTEM. J.V. and F.H. thank the financial support from the European Union under the Framework 6 program under a contract for an Integrated Infrastructure Initiative. Reference 026019 ESTEEM. Thanks to J.P. Morniroli for making the Fe sample available. |
Approved |
Most recent IF: 2.843; 2008 IF: 2.629 |
Call Number |
UA @ lucian @ c:irua:76492UA @ admin @ c:irua:76492 |
Serial |
2480 |
Permanent link to this record |
|
|
|
Author |
de Backer, A.; De wael, A.; Gonnissen, J.; Van Aert, S. |
Title |
Optimal experimental design for nano-particle atom-counting from high-resolution STEM images |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
151 |
Issue |
151 |
Pages |
46-55 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In the present paper, the principles of detection theory are used to quantify the probability of error for atom-counting from high resolution scanning transmission electron microscopy (HR STEM) images. Binary and multiple hypothesis testing have been investigated in order to determine the limits to the precision with which the number of atoms in a projected atomic column can be estimated. The probability of error has been calculated when using STEM images, scattering cross-sections or peak intensities as a criterion to count atoms. Based on this analysis, we conclude that scattering cross-sections perform almost equally well as images and perform better than peak intensities. Furthermore, the optimal STEM detector design can be derived for atom-counting using the expression for the probability of error. We show that for very thin objects LAADF is optimal and that for thicker objects the optimal inner detector angle increases. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000351237800007 |
Publication Date |
2014-11-11 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
24 |
Open Access |
|
Notes |
312483 Esteem2; Fwo G039311; G037413; esteem2_jra2 |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:123926 c:irua:123926 |
Serial |
2481 |
Permanent link to this record |
|
|
|
Author |
Van Aert, S.; den Dekker, A.J.; van Dyck, D.; van den Bos, A. |
Title |
Optimal experimental design of STEM measurement of atom column positions |
Type |
A1 Journal article |
Year |
2002 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
90 |
Issue |
|
Pages |
273-289 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000174770900004 |
Publication Date |
2002-07-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
35 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 2.843; 2002 IF: 1.772 |
Call Number |
UA @ lucian @ c:irua:47517 |
Serial |
2483 |
Permanent link to this record |
|
|
|
Author |
Tan, H.; Verbeeck, J.; Abakumov, A.; Van Tendeloo, G. |
Title |
Oxidation state and chemical shift investigation in transition metal oxides by EELS |
Type |
A1 Journal article |
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
116 |
Issue |
|
Pages |
24-33 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Transition metal L2,3 electron energy-loss spectra for a wide range of V-, Mn- and Fe-based oxides were recorded and carefully analyzed for their correlation with the formal oxidation states of the transition metal ions. Special attention is paid to obtain an accurate energy scale which provides absolute energy positions for all core-loss edges. The white-line ratio method, chemical shift method, ELNES fitting method, two-parameter method and other methods are compared and their validity is discussed. Both the ELNES fitting method and the chemical shift method have the advantage of a wide application range and good consistency but require special attention to accurately measure the core-loss edge position. The obtained conclusions are of fundamental importance, e.g., for obtaining atomic resolution oxidation state information in modern experiments. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000304473700004 |
Publication Date |
2012-03-10 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
413 |
Open Access |
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
Call Number |
UA @ lucian @ c:irua:96959UA @ admin @ c:irua:96959 |
Serial |
2541 |
Permanent link to this record |
|
|
|
Author |
Verbeeck, J.; van Dyck, D.; Lichte, H.; Potapov, P.; Schattschneider, P. |
Title |
Plasmon holographic experiments: theoretical framework |
Type |
A1 Journal article |
Year |
2005 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
102 |
Issue |
3 |
Pages |
239-255 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
A theoretical framework is described to understand the results of plasmon holography experiments leading to insight in the meaning of the experimental results and pointing out directions for future experiments. The framework is based on the formalism of mutual intensity to describe how coherence is transferred through an optical system. For the inelastic interaction with the object, an expression for the volume. plasmon excitations in a free electron gas is used as a model for the behaviour of aluminium. The formalism leads to a clear graphical intuitive tool for under-standing the experiments. It becomes evident that the measured coherence is solely related to the angular distribution of the plasmon scattering in the case of bulk plasmons. After describing the framework, the special case of coherence outside a spherical particle is treated and the seemingly controversial idea of a plasmon with a limited coherence length obtained front experiments is clarified. (C) 2004 Elsevier B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000226436600010 |
Publication Date |
2004-11-05 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
43 |
Open Access |
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2005 IF: 2.490 |
Call Number |
UA @ lucian @ c:irua:57133UA @ admin @ c:irua:57133 |
Serial |
2643 |
Permanent link to this record |
|
|
|
Author |
Van Eyndhoven, G.; Kurttepeli, M.; van Oers, C.J.; Cool, P.; Bals, S.; Batenburg, K.J.; Sijbers, J. |
Title |
Pore REconstruction and Segmentation (PORES) method for improved porosity quantification of nanoporous materials |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
148 |
Issue |
148 |
Pages |
10-19 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Laboratory of adsorption and catalysis (LADCA) |
Abstract |
Electron tomography is currently a versatile tool to investigate the connection between the structure and properties of nanomaterials. However, a quantitative interpretation of electron tomography results is still far from straightforward. Especially accurate quantification of pore-space is hampered by artifacts introduced in all steps of the processing chain, i.e., acquisition, reconstruction, segmentation and quantification. Furthermore, most common approaches require subjective manual user input. In this paper, the PORES algorithm POre REconstruction and Segmentation is introduced; it is a tailor-made, integral approach, for the reconstruction, segmentation, and quantification of porous nanomaterials. The PORES processing chain starts by calculating a reconstruction with a nanoporous-specific reconstruction algorithm: the Simultaneous Update of Pore Pixels by iterative REconstruction and Simple Segmentation algorithm (SUPPRESS). It classifies the interior region to the pores during reconstruction, while reconstructing the remaining region by reducing the error with respect to the acquired electron microscopy data. The SUPPRESS reconstruction can be directly plugged into the remaining processing chain of the PORES algorithm, resulting in accurate individual pore quantification and full sample pore statistics. The proposed approach was extensively validated on both simulated and experimental data, indicating its ability to generate accurate statistics of nanoporous materials. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000345973000002 |
Publication Date |
2014-08-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
7 |
Open Access |
OpenAccess |
Notes |
Colouratom; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:119083 |
Serial |
2672 |
Permanent link to this record |
|
|
|
Author |
Heidari Mezerji, H.; van den Broek, W.; Bals, S. |
Title |
A practical method to determine the effective resolution in incoherent experimental electron tomography |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
111 |
Issue |
5 |
Pages |
330-336 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
It is not straightforward to determine resolution for a 3D reconstruction when performing an electron tomography experiment. Different contributions such as missing wedge and misalignment add up and often influence the final resolution in an anisotropic manner. The conventional resolution measures can not be used for all of the reconstruction techniques, especially for iterative techniques which are more commonly used for electron tomography in materials science. Here we define a quantitative resolution measure that determines the resolution in three orthogonal directions of the reconstruction. As an application we use this measure to determine the optimum number of simultaneous iterative reconstruction technique (SIRT) iterations to reconstruct the gold nanoparticles, based on a high angle annular dark field STEM (HAADF-STEM) tilt series. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000289396900005 |
Publication Date |
2011-01-24 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
26 |
Open Access |
|
Notes |
Esteem 026019; Fwo |
Approved |
Most recent IF: 2.843; 2011 IF: 2.471 |
Call Number |
UA @ lucian @ c:irua:87606 |
Serial |
2688 |
Permanent link to this record |
|
|
|
Author |
Wang, A.; Van Aert, S.; Goos, P.; van Dyck, D. |
Title |
Precision of three-dimensional atomic scale measurements from HRTEM images : what are the limits? |
Type |
A1 Journal article |
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
114 |
Issue |
|
Pages |
20-30 |
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In this paper, we investigate to what extent high resolution transmission electron microscopy images can be used to measure the mass, in terms of thickness, and surface profile, corresponding to the defocus offset, of an object at the atomic scale. Therefore, we derive an expression for the statistical precision with which these object parameters can be estimated in a quantitative analysis. Evaluating this expression as a function of the microscope settings allows us to derive the optimal microscope design. Acquiring three-dimensional structure information in terms of thickness turns out to be much more difficult than obtaining two-dimensional information on the projected atom column positions. The attainable precision is found to be more strongly affected by processes influencing the image contrast, such as phonon scattering, than by the specific choice of microscope settings. For a realistic incident electron dose, it is expected that atom columns can be distinguished with single atom sensitivity up to a thickness of the order of the extinction distance. A comparable thickness limit is determined to measure surface steps of one atom. An increase of the electron dose shifts the limiting thickness upward due to an increase in the signal-to-noise ratio. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000301954300003 |
Publication Date |
2012-01-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
5 |
Open Access |
|
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
Call Number |
UA @ lucian @ c:irua:94116 |
Serial |
2692 |
Permanent link to this record |
|
|
|
Author |
Chen, D.; Goris, B.; Bleichrodt, F.; Heidari Mezerji, H.; Bals, S.; Batenburg, K.J.; de With, G.; Friedrich, H. |
Title |
The properties of SIRT, TVM, and DART for 3D imaging of tubular domains in nanocomposite thin-films and sections |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
147 |
Issue |
|
Pages |
137-148 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In electron tomography, the fidelity of the 3D reconstruction strongly depends on the employed reconstruction algorithm. In this paper, the properties of SIRT, TVM and DART reconstructions are studied with respect to having only a limited number of electrons available for imaging and applying different angular sampling schemes. A well-defined realistic model is generated, which consists of tubular domains within a matrix having slab-geometry. Subsequently, the electron tomography workflow is simulated from calculated tilt-series over experimental effects to reconstruction. In comparison with the model, the fidelity of each reconstruction method is evaluated qualitatively and quantitatively based on global and local edge profiles and resolvable distance between particles. Results show that the performance of all reconstruction methods declines with the total electron dose. Overall, SIRT algorithm is the most stable method and insensitive to changes in angular sampling. TVM algorithm yields significantly sharper edges in the reconstruction, but the edge positions are strongly influenced by the tilt scheme and the tubular objects become thinned. The DART algorithm markedly suppresses the elongation artifacts along the beam direction and moreover segments the reconstruction which can be considered a significant advantage for quantification. Finally, no advantage of TVM and DART to deal better with fewer projections was observed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000343157400015 |
Publication Date |
2014-08-19 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
42 |
Open Access |
OpenAccess |
Notes |
Fwo |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
Call Number |
UA @ lucian @ c:irua:119073 |
Serial |
2729 |
Permanent link to this record |
|
|
|
Author |
Guzzinati, G.; Clark, L.; Béché, A.; Juchtmans, R.; Van Boxem, R.; Mazilu, M.; Verbeeck, J. |
Title |
Prospects for versatile phase manipulation in the TEM : beyond aberration correction |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
151 |
Issue |
151 |
Pages |
85-93 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In this paper we explore the desirability of a transmission electron microscope in which the phase of the electron wave can be freely controlled. We discuss different existing methods to manipulate the phase of the electron wave and their limitations. We show how with the help of current techniques the electron wave can already be crafted into specific classes of waves each having their own peculiar properties. Assuming a versatile phase modulation device is feasible, we explore possible benefits and methods that could come into existence borrowing from light optics where the so-called spatial light modulators provide programmable phase plates for quite some time now. We demonstrate that a fully controllable phase plate building on Harald Rose׳s legacy in aberration correction and electron optics in general would open an exciting field of research and applications. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000351237800012 |
Publication Date |
2014-10-22 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
19 |
Open Access |
|
Notes |
278510 Vortex; Fwo; 312483 Esteem2; esteem2jra2; esteem2jra3 ECASJO_; |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:121405 c:irua:121405UA @ admin @ c:irua:121405 |
Serial |
2731 |
Permanent link to this record |
|
|
|
Author |
Bertoni, G.; Beyers, E.; Verbeeck, J.; Mertens, M.; Cool, P.; Vansant, E.F.; Van Tendeloo, G. |
Title |
Quantification of crystalline and amorphous content in porous TiO2 samples from electron energy loss spectroscopy |
Type |
A1 Journal article |
Year |
2006 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
106 |
Issue |
7 |
Pages |
630-635 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA) |
Abstract |
We present an efficient method for the quantification of crystalline versus amorphous phase content in mesoporous materials, making use of electron energy loss spectroscopy. The method is based on fitting a superposition of core-loss edges using the maximum likelihood method with measured reference spectra. We apply the method to mesoporous TiO2 samples. We show that the absolute amount of the crystalline phase can be determined with an accuracy below 5%. This method takes also the amorphous phase into account, where standard X-ray diffraction is only quantitative for crystalline phases and not for amorphous phase. (c) 2006 Elsevier B.V.. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000238479300011 |
Publication Date |
2006-04-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
83 |
Open Access |
|
Notes |
Iap-V; Goa-2005; Fwo |
Approved |
Most recent IF: 2.843; 2006 IF: 1.706 |
Call Number |
UA @ lucian @ c:irua:58823UA @ admin @ c:irua:58823 |
Serial |
2741 |
Permanent link to this record |
|
|
|
Author |
Van Aert, S.; Verbeeck, J.; Erni, R.; Bals, S.; Luysberg, M.; van Dyck, D.; Van Tendeloo, G. |
Title |
Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
10 |
Pages |
1236-1244 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
A model-based method is proposed to relatively quantify the chemical composition of atomic columns using high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. The method is based on a quantification of the total intensity of the scattered electrons for the individual atomic columns using statistical parameter estimation theory. In order to apply this theory, a model is required describing the image contrast of the HAADF STEM images. Therefore, a simple, effective incoherent model has been assumed which takes the probe intensity profile into account. The scattered intensities can then be estimated by fitting this model to an experimental HAADF STEM image. These estimates are used as a performance measure to distinguish between different atomic column types and to identify the nature of unknown columns with good accuracy and precision using statistical hypothesis testing. The reliability of the method is supported by means of simulated HAADF STEM images as well as a combination of experimental images and electron energy-loss spectra. It is experimentally shown that statistically meaningful information on the composition of individual columns can be obtained even if the difference in averaged atomic number Z is only 3. Using this method, quantitative mapping at atomic resolution using HAADF STEM images only has become possible without the need of simultaneously recorded electron energy loss spectra. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000270015200004 |
Publication Date |
2009-05-28 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
166 |
Open Access |
|
Notes |
Fwo; Esteem 026019 |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:78585UA @ admin @ c:irua:78585 |
Serial |
2748 |
Permanent link to this record |
|
|
|
Author |
Martinez, G.T.; Rosenauer, A.; de Backer, A.; Verbeeck, J.; Van Aert, S. |
Title |
Quantitative composition determination at the atomic level using model-based high-angle annular dark field scanning transmission electron microscopy |
Type |
A1 Journal article |
Year |
2014 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
137 |
Issue |
|
Pages |
12-19 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
High angle annular dark field scanning transmission electron microscopy (HAADF STEM) images provide sample information which is sensitive to the chemical composition. The image intensities indeed scale with the mean atomic number Z. To some extent, chemically different atomic column types can therefore be visually distinguished. However, in order to quantify the atomic column composition with high accuracy and precision, model-based methods are necessary. Therefore, an empirical incoherent parametric imaging model can be used of which the unknown parameters are determined using statistical parameter estimation theory (Van Aert et al., 2009, [1]). In this paper, it will be shown how this method can be combined with frozen lattice multislice simulations in order to evolve from a relative toward an absolute quantification of the composition of single atomic columns with mixed atom types. Furthermore, the validity of the model assumptions are explored and discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000331092200003 |
Publication Date |
2013-11-09 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
74 |
Open Access |
|
Notes |
FWO; FP7; ERC Countatoms; ESTEEM2; esteem2_ta |
Approved |
Most recent IF: 2.843; 2014 IF: 2.436 |
Call Number |
UA @ lucian @ c:irua:111579UA @ admin @ c:irua:111579 |
Serial |
2749 |
Permanent link to this record |
|
|
|
Author |
Heidari, H.; van den Broek, W.; Bals, S. |
Title |
Quantitative electron tomography : the effect of the three-dimensional point spread function |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
135 |
Issue |
|
Pages |
1-5 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The intensity levels in a three-dimensional (3D) reconstruction, obtained by electron tomography, can be influenced by several experimental imperfections. Such artifacts will hamper a quantitative interpretation of the results. In this paper, we will correct for artificial intensity variations by determining the 3D point spread function (PSF) of a tomographic reconstruction based on high angle annular dark field scanning transmission electron microscopy. The large tails of the PSF cause an underestimation of the intensity of smaller particles, which in turn hampers an accurate radius estimate. Here, the error introduced by the PSF is quantified and corrected a posteriori. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000326941500001 |
Publication Date |
2013-06-21 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
6 |
Open Access |
|
Notes |
Esteem2; Sunflower; esteem2_jra4 |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
Call Number |
UA @ lucian @ c:irua:111397 |
Serial |
2756 |
Permanent link to this record |
|
|
|
Author |
Martinez, G.T.; Jones, L.; de Backer, A.; Béché, A.; Verbeeck, J.; Van Aert, S.; Nellist, P.D. |
Title |
Quantitative STEM normalisation : the importance of the electron flux |
Type |
A1 Journal article |
Year |
2015 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
159 |
Issue |
159 |
Pages |
46-58 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Annular dark-field (ADF) scanning transmission electron microscopy (STEM) has become widely used in quantitative studies based on the opportunity to directly compare experimental and simulated images. This comparison merely requires the experimental data to be normalised and expressed in units of fractional beam-current. However, inhomogeneities in the response of electron detectors can complicate this normalisation. The quantification procedure becomes both experiment and instrument specific, requiring new simulations for the particular response of each instrument's detector, and for every camera-length used. This not only impedes the comparison between different instruments and research groups, but can also be computationally very time consuming. Furthermore, not all image simulation methods allow for the inclusion of an inhomogeneous detector response. In this work, we propose an alternative method for normalising experimental data in order to compare these with simulations that consider a homogeneous detector response. To achieve this, we determine the electron flux distribution reaching the detector by means of a camera-length series or a so-called atomic column cross-section averaged convergent beam electron diffraction (XSACBED) pattern. The result is then used to determine the relative weighting of the detector response. Here we show that the results obtained by this new electron flux weighted (EFW) method are comparable to the currently used method, while considerably simplifying the needed simulation libraries. The proposed method also allows one to obtain a metric that describes the quality of the detector response in comparison with the ideal detector response. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000366220000006 |
Publication Date |
2015-08-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
27 |
Open Access |
|
Notes |
246791 Countatoms; 278510 Vortex; 312483 Esteem2; Fwo G036815; G036915; G037413; G004413; esteem2ta ECASJO; |
Approved |
Most recent IF: 2.843; 2015 IF: 2.436 |
Call Number |
c:irua:127293 c:irua:127293UA @ admin @ c:irua:127293 |
Serial |
2762 |
Permanent link to this record |
|
|
|
Author |
Schattschneider, P.; Verbeeck, J.; Hamon, A.L. |
Title |
Real space maps of atomic transitions |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
7 |
Pages |
781-787 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Considering the rapid technical development of transmission electron microscopes, we investigate the possibility to map electronic transitions in real space on the atomic scale. To this purpose, we analyse the information carried by the scatterer's initial and final state wave functions and the role of the different atomic transition channels for the inelastic scattering cross section. It is shown that the change in the magnetic quantum number in the transition can be mapped. Two experimental set-ups are proposed, one blocking half the diffraction plane, the other one using a cylinder lens for imaging. Both methods break the conventional circular symmetry in the electron microscope making it possible to detect the handedness of electronic transitions as an asymmetry in the image intensity. This finding is of important for atomic resolution energy-loss magnetic chiral dichroism (EMCD), allowing to obtain the magnetic moments of single atoms. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000266787900002 |
Publication Date |
2009-03-01 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
10 |
Open Access |
|
Notes |
J.V. acknowledges the FWO-Vlaanderen for support (contract no. G.0147.06) and the European Union under the Framework 6 program under a contract for an Integrated Infrastructure Initiative. Reference 026019 ESTEEM. |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:77360UA @ admin @ c:irua:77360 |
Serial |
2829 |
Permanent link to this record |
|
|
|
Author |
Schattschneider, P.; Ennen, I.; Stoger-Pollach, M.; Verbeeck, J.; Mauchamp, V.; Jaouen, M. |
Title |
Real space maps of magnetic moments on the atomic scale: theory and feasibility |
Type |
A1 Journal article |
Year |
2010 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
110 |
Issue |
8 |
Pages |
1038-1041 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The recently discovered EMCD technique (energy loss magnetic chiral dichroism) can detect atom specific magnetic moments with nanometer resolution, exploiting the spin selectivity of electronic transitions in energy loss spectroscopy. Yet, direct imaging of magnetic moments on the atomic scale is not possible. In this paper we present an extension of EMCD that can overcome this limit. As a model system we chose bcc Fe. We present image simulations of the L3 white line signal, based on the kinetic equation for the density matrix of the 200 kV probe electron. With actual progress in instrumentation (high brightness sources, aberration corrected lenses) this technique should allow direct imaging of spin moments on the atomic scale. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000281216600016 |
Publication Date |
2009-12-07 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
10 |
Open Access |
|
Notes |
--- |
Approved |
Most recent IF: 2.843; 2010 IF: 2.063 |
Call Number |
UA @ lucian @ c:irua:84439UA @ admin @ c:irua:84439 |
Serial |
2830 |
Permanent link to this record |
|
|
|
Author |
Zhang, X.B.; Zhang, X.F.; Amelinckx, S.; Van Tendeloo, G.; van Landuyt, J. |
Title |
The reciprocal space of carbon tubes: a detailed interpretation of the electron diffraction effects |
Type |
A1 Journal article |
Year |
1994 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
54 |
Issue |
|
Pages |
237-249 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
A1994PA59800016 |
Publication Date |
2002-10-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.436 |
Times cited |
59 |
Open Access |
|
Notes |
|
Approved |
|
Call Number |
UA @ lucian @ c:irua:10006 |
Serial |
2844 |
Permanent link to this record |
|
|
|
Author |
Müller, K.; Schowalter, M.; Jansen, J.; Tsuda, K.; Titantah, J.; Lamoen, D.; Rosenauer, A. |
Title |
Refinement of the 200 structure factor for GaAs using parallel and convergent beam electron nanodiffraction data |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
7 |
Pages |
802-814 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
We present a new method to measure structure factors from electron spot diffraction patterns recorded under almost parallel illumination in transmission electron microscopes. Bloch wave refinement routines have been developed to refine the crystal thickness, its orientation and structure factors by comparison of experimentally recorded and calculated intensities. Our method requires a modicum of computational effort, making it suitable for contemporary personal computers. Frozen lattice and Bloch wave simulations of GaAs diffraction patterns are used to derive optimised experimental conditions. Systematic errors are estimated from the application of the method to simulated diffraction patterns and rules for the recognition of physically reasonable initial refinement conditions are derived. The method is applied to the measurement of the 200 structure factor for GaAs. We found that the influence of inelastically scattered electrons is negligible. Additionally, we measured the 200 structure factor from zero loss filtered two-dimensional convergent beam electron diffraction patterns. The precision of both methods is found to be comparable and the results agree well with each other. A deviation of more than 20% from isolated atom scattering data is observed, whereas close agreement is found with structure factors obtained from density functional theory [A. Rosenauer, M. Schowalter, F. Glas, D. Lamoen, Phys. Rev. B 72 (2005), 085326-1], which account for the redistribution of electrons due to chemical bonding via modified atomic scattering amplitudes. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000266787900005 |
Publication Date |
2009-03-23 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
8 |
Open Access |
|
Notes |
Fwo; G.0425.05; Esteem; Ant 200611271505 |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:77361 |
Serial |
2856 |
Permanent link to this record |
|
|
|
Author |
Amelinckx, S.; Milat, O.; Van Tendeloo, G. |
Title |
Selective imaging of sublattices in complex structures |
Type |
A1 Journal article |
Year |
1993 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
51 |
Issue |
|
Pages |
90-108 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
A1993LN79100010 |
Publication Date |
2002-10-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.436 |
Times cited |
8 |
Open Access |
|
Notes |
|
Approved |
CHEMISTRY, PHYSICAL 54/144 Q2 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 9/35 Q2 # |
Call Number |
UA @ lucian @ c:irua:6835 |
Serial |
2964 |
Permanent link to this record |
|
|
|
Author |
Milat, O.; Van Tendeloo, G.; Amelinckx, S. |
Title |
Selective imaging of the “substructures” in incommensurately modulated intergrowth crystal structures |
Type |
A1 Journal article |
Year |
1992 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
41 |
Issue |
|
Pages |
65-76 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
A1992HX68100006 |
Publication Date |
2002-10-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.436 |
Times cited |
5 |
Open Access |
|
Notes |
|
Approved |
MATERIALS SCIENCE, MULTIDISCIPLINARY 96/271 Q2 # |
Call Number |
UA @ lucian @ c:irua:4437 |
Serial |
2966 |
Permanent link to this record |
|
|
|
Author |
Zhang, X.F.; Zhang, X.B.; Bernaerts, D.; Van Tendeloo, G.; Amelinckx, S.; van Landuyt, J.; Werner, H. |
Title |
A simple preparation method for air-sensitive specimens for transmission electron microscopy demonstrated by Rb6C60 |
Type |
A1 Journal article |
Year |
1994 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
55 |
Issue |
|
Pages |
25-30 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
In this paper a particularly simple but efficient method is presented by which samples of alkali-doped C-60 materials or other air-sensitive materials can be prepared and transferred into a transmission electron microscope for direct observations and investigations. Flexible, transparent glove bags are used which are filled to a slight overpressure with dry nitrogen. Under this protective atmosphere, the air-sensitive sample is mounted in the specimen holder and inserted in the vacuum of the electron microscope. Rb6C60 which is prepared and transferred into the microscope in this way has been investigated by transmission electron microscopy (TEM). The results confirm the bcc structure and especially the location of the rubidium atoms. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
A1994PE30800005 |
Publication Date |
2002-10-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.436 |
Times cited |
2 |
Open Access |
|
Notes |
|
Approved |
CHEMISTRY, PHYSICAL 77/144 Q3 # MATHEMATICS, INTERDISCIPLINARY 19/101 Q1 # PHYSICS, ATOMIC, MOLECULAR & CHEMICAL 17/35 Q2 # |
Call Number |
UA @ lucian @ c:irua:10007 |
Serial |
3002 |
Permanent link to this record |
|
|
|
Author |
Lichtert, S.; Verbeeck, J. |
Title |
Statistical consequences of applying a PCA noise filter on EELS spectrum images |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
125 |
Issue |
|
Pages |
35-42 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Principal component analysis (PCA) noise filtering is a popular method to remove noise from experimental electron energy loss (EELS) spectrum images. Here, we investigate the statistical behaviour of this method by applying it on a simulated data set with realistic noise levels. This phantom data set provides access to the true values contained in the data set as well as to many different realizations of the noise. Using least squares fitting and parameter estimation theory, we demonstrate that even though the precision on the estimated parameters can be better as the CramérRao lower bound, a significant bias is introduced which can alter the conclusions drawn from experimental data sets. The origin of this bias is in the incorrect retrieval of the principal loadings for noisy data. Using an expression for the bias and precision of the singular values from literature, we present an evaluation criterion for these singular values based on the noise level and the amount of information present in the data set. This criterion can help to judge when to avoid PCA noise filtering in practical situations. Further we show that constructing elemental maps of PCA noise filtered data using the background subtraction method, does not guarantee an increase in the signal to noise ratio due to correlation of the spectral data as a result of the filtering process. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000314679700006 |
Publication Date |
2012-10-27 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
54 |
Open Access |
|
Notes |
Fwo; Countatoms; Vortex; Esteem 312483; esteem2jra3 ECASJO; |
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
Call Number |
UA @ lucian @ c:irua:105293 |
Serial |
3153 |
Permanent link to this record |
|
|
|
Author |
Béché, A.; Rouviere, J.L.; Barnes, J.P.; Cooper, D. |
Title |
Strain measurement at the nanoscale : comparison between convergent beam electron diffraction, nano-beam electron diffraction, high resolution imaging and dark field electron holography |
Type |
A1 Journal article |
Year |
2013 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
131 |
Issue |
|
Pages |
10-23 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
Convergent beam electron diffraction (CBED), nano-beam electron diffraction (NBED or NBD), high resolution imaging (HRTEM and HRSTEM) and dark field electron holography (DFEH or HoloDark) are five TEM based techniques able to quantitatively measure strain at the nanometer scale. In order to demonstrate the advantages and disadvantages of each technique, two samples composed of epitaxial silicon-germanium layers embedded in a silicon matrix have been investigated. The five techniques are then compared in terms of strain precision and accuracy, spatial resolution, field of view, mapping abilities and ease of performance and analysis. (C) 2013 Elsevier By. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000322631200002 |
Publication Date |
2013-04-06 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
73 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 2.843; 2013 IF: 2.745 |
Call Number |
UA @ lucian @ c:irua:109774 |
Serial |
3171 |
Permanent link to this record |
|
|
|
Author |
Van Tendeloo, G.; Amelinckx, S.; Muto, S.; Verheijen, M.A.; van Loosdrecht, P.H.M.; Meijer, G. |
Title |
Structures and phase transitions in C60 and C70 fullerites |
Type |
A1 Journal article |
Year |
1993 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
51 |
Issue |
|
Pages |
168-188 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
|
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
A1993LN79100017 |
Publication Date |
2002-10-18 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.436 |
Times cited |
17 |
Open Access |
|
Notes |
|
Approved |
PHYSICS, APPLIED 28/145 Q1 # |
Call Number |
UA @ lucian @ c:irua:6836 |
Serial |
3319 |
Permanent link to this record |
|
|
|
Author |
Schattschneider, P.; Stöger-Pollach, M.; Löffler, S.; Steiger-Thirsfeld, A.; Hell, J.; Verbeeck, J. |
Title |
Sub-nanometer free electrons with topological charge |
Type |
A1 Journal article |
Year |
2012 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
115 |
Issue |
|
Pages |
21-25 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The holographic mask technique is used to create freely moving electrons with quantized angular momentum. With electron optical elements they can be focused to vortices with diameters below the nanometer range. The understanding of these vortex beams is important for many applications. Here, we produce electron vortex beams and compare them to a theory of electrons with topological charge. The experimental results show excellent agreement with simulations. As an immediate application, fundamental experimental parameters like spherical aberration and partial coherence are determined. (C) 2012 Elsevier B.V. All rights reserved. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000302962400004 |
Publication Date |
2012-01-30 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
24 |
Open Access |
|
Notes |
vortex ECASJO_; |
Approved |
Most recent IF: 2.843; 2012 IF: 2.470 |
Call Number |
UA @ lucian @ c:irua:98279 |
Serial |
3344 |
Permanent link to this record |
|
|
|
Author |
Ke, X.; Bals, S.; Romo Negreira, A.; Hantschel, T.; Bender, H.; Van Tendeloo, G. |
Title |
TEM sample preparation by FIB for carbon nanotube interconnects |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
11 |
Pages |
1353-1359 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000270765800006 |
Publication Date |
2009-07-11 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
21 |
Open Access |
|
Notes |
Esteem 026019; Iap |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:79074 |
Serial |
3485 |
Permanent link to this record |
|
|
|
Author |
Schattschneider, P.; Verbeeck, J. |
Title |
Theory of free electron vortices |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
111 |
Issue |
9/10 |
Pages |
1461-1468 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT) |
Abstract |
The recent creation of electron vortex beams and their first practical application motivates a better understanding of their properties. Here, we develop the theory of free electron vortices with quantized angular momentum, based on solutions of the Schrödinger equation for cylindrical boundary conditions. The principle of transformation of a plane wave into vortices with quantized angular momentum, their paraxial propagation through round magnetic lenses, and the effect of partial coherence are discussed. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000300461200002 |
Publication Date |
2011-07-26 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
57 |
Open Access |
|
Notes |
Esteem 026019 |
Approved |
Most recent IF: 2.843; 2011 IF: 2.471 |
Call Number |
UA @ lucian @ c:irua:91882 |
Serial |
3617 |
Permanent link to this record |
|
|
|
Author |
van den Broek, W.; Van Aert, S.; Goos, P.; van Dyck, D. |
Title |
Throughput maximization of particle radius measurements by balancing size and current of the electron probe |
Type |
A1 Journal article |
Year |
2011 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
111 |
Issue |
7 |
Pages |
940-947 |
Keywords |
A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
In thispaperweinvestigatewhichprobesizemaximizesthethroughputwhenmeasuringtheradiusof nanoparticlesinhighangleannulardarkfieldscanningtransmissionelectronmicroscopy(HAADFSTEM). The sizeandthecorrespondingcurrentoftheelectronprobedeterminetheprecisionoftheestimateofa particlesradius.Maximizingthroughputmeansthatamaximumnumberofparticlesshouldbeimaged withinagiventimeframe,sothataprespecifiedprecisionisattained.WeshowthatBayesianstatistical experimentaldesignisaveryusefulapproachtodeterminetheoptimalprobesizeusingacertainamount of priorknowledgeaboutthesample.Thedependenceoftheoptimalprobesizeonthedetectorgeometry and thediameter,variabilityandatomicnumberoftheparticlesisinvestigated.Anexpressionforthe optimalprobesizeintheabsenceofanykindofpriorknowledgeaboutthespecimenisderivedaswell. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000300461000026 |
Publication Date |
2010-11-25 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
7 |
Open Access |
|
Notes |
|
Approved |
Most recent IF: 2.843; 2011 IF: 2.471 |
Call Number |
UA @ lucian @ c:irua:89657 |
Serial |
3659 |
Permanent link to this record |
|
|
|
Author |
van den Broek, W.; Verbeeck, J.; Schryvers, D.; de Backer, S.; Scheunders, P. |
Title |
Tomographic spectroscopic imaging; an experimental proof of concept |
Type |
A1 Journal article |
Year |
2009 |
Publication |
Ultramicroscopy |
Abbreviated Journal |
Ultramicroscopy |
Volume |
109 |
Issue |
4 |
Pages |
296-303 |
Keywords |
A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab |
Abstract |
Recording the electron energy loss spectroscopy data cube with a series of energy filtered images is a dose inefficient process because the energy slit blocks most of the electrons. When recording the data cube by scanning an electron probe over the sample, perfect dose efficiency is attained; but due to the low current in nanoprobes, this often is slower, with a smaller field of view. In W. Van den Broek et al. [Ultramicroscopy, 106 (2006) 269], we proposed a new method to record the data cube, which is more dose efficient than an energy filtered series. It produces a set of projections of the data cube and then tomographically reconstructs it. In this article, we demonstrate these projections in practice, we present a simple geometrical model that allows for quantification of the projection angles and we present the first successful experimental reconstruction, all on a standard post-column instrument. |
Address |
|
Corporate Author |
|
Thesis |
|
Publisher |
|
Place of Publication |
Amsterdam |
Editor |
|
Language |
|
Wos |
000265345400003 |
Publication Date |
2008-12-10 |
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0304-3991; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
Impact Factor |
2.843 |
Times cited |
1 |
Open Access |
|
Notes |
Esteem 026019 |
Approved |
Most recent IF: 2.843; 2009 IF: 2.067 |
Call Number |
UA @ lucian @ c:irua:77271 |
Serial |
3671 |
Permanent link to this record |