“Intercalation of proflavine in ssDNA aptamers : effect on binding of the specific target chloramphenicol”. Pilehvar S, Jambrec D, Gebala M, Schuhmann W, De Wael K, Electroanalysis 27, 1836 (2015). http://doi.org/10.1002/ELAN.201500192
Abstract: The structural modification of ssDNA-based aptamers upon specific binding of its target molecule leads to changes of the charge-transfer resistance (Rct) of a negatively-charged free-diffusing redox probe. The aptamer adopts a structure due to self-hybridization which is stabilized using profalvine as intercalator. The pre-organized aptamer structure is used to detect chloramphenicol (CAP) requiring a substantial change of the aptamer structure indicated by a CAP concentration dependent increase in the Rct values. Pre-incubation of the aptamer-modified electrode with an intercalator allows for the modulation of the aptamer/target interaction and hence for a modulation of the CAP-dependent variation of the Rct values.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.851
Times cited: 5
DOI: 10.1002/ELAN.201500192
|
“Label-free impedance aptasensor for major peanut allergen Ara h 1”. Trashin S, De Jong M, Breugelmans T, Pilehvar S, De Wael K, Electroanalysis 27, 32 (2015). http://doi.org/10.1002/ELAN.201400365
Abstract: The peanut allergen Ara h 1 belonging to the vicilin family of seed storage proteins is known to be a suitable marker for peanut detection in foods. In the present work, we suggest an electrochemical detection of Ara h 1 using a recently selected 80-base DNA aptamer. The detection strategy relies on insulation effect of a bulky protein captured by an immobilized aptamer. The electrodes were modified by the aptamer and characterized using electrochemical impedance spectroscopy (EIS). The aptamer surface density and analytical parameters of the calibration curves for Ara h 1 were compared with the system prepared with thrombin binding aptamer (TBA) and operated in the same conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Times cited: 10
DOI: 10.1002/ELAN.201400365
|
“Photodegradation mechanisms and kinetics of Eosin-Y in oxic and anoxic conditions”. Alvarez-Martin A, Trashin S, Cuykx M, Covaci A, De Wael K, Janssens K, Dyes and pigments 145, 376 (2017). http://doi.org/10.1016/J.DYEPIG.2017.06.031
Abstract: Lakes based on Eosin-Y are extensively used by 19th century artists. Unfortunately, the identification of these pigments in paintings is a difficult task because Eosin-Y degrades very fast under the influence of light. The characterization of the (photo)degradation products of Eosin-Y can be very useful for the identification of these pigments in historic works of art and related cultural heritage artifacts. Furthermore, knowledge on how different factors influence the discoloration process (e.g. different types of irradiation sources and presence/absence of oxygen) is a valuable tool for preventive conservation. To this aim we performed a study on the photodegradation of Eosin-Y in solution under different illumination and in both oxic and anoxic conditions. The photodegradation of Eosin-Y was monitored by UV-VIS spectrophotometry, LC-QTOFMS and electrochemistry techniques. Results indicated higher degradation rates, by a factor of 20 or higher, under illumination with wavelengths near to the main absorbance band of the red pigment. Two different degradation pathways are observed under the conditions studied. LC-QTOFMS and electrochemistry suggested that in the presence of oxygen the degradation mechanism is an oxidative process where the breakdown of the structure causes the total discoloration. Meanwhile under anoxic conditions, a debromination process takes place while the chromophore, and consequently the color of the molecule in solution, remains essentially intact.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.473
Times cited: 18
DOI: 10.1016/J.DYEPIG.2017.06.031
|
“Understanding the (in)stability of semiconductor pigments by a thermodynamic approach”. Anaf W, Schalm O, Janssens K, De Wael K, Dyes and pigments 113, 409 (2015). http://doi.org/10.1016/J.DYEPIG.2014.09.015
Abstract: Several artists pigments are semiconductors. Some of these materials appear stable over time, whereas others already show remarkable signs of degradation after limited time periods. The (in)stability of these pigments can be understood using a thermodynamic approach. For several pigment-related materials, the thermodynamic oxidation and reduction potential (ϕox and ϕred) were determined and evaluated considering the absolute energy positions of the valence and conduction band edges and the water redox potentials. The positions of ϕox and ϕred can be used in a fast screening of the stability of semiconductor pigments towards photoinduced corrosion in an aqueous/humid environment. This theoretical approach corresponds well with experimental data on pigment permanence and degradation phenomena found in literature.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
Impact Factor: 3.473
Times cited: 14
DOI: 10.1016/J.DYEPIG.2014.09.015
|
“Geranium lake pigments : the role of the synthesis on the structure and composition”. Beltran V, Marchetti A, De Meyer S, Nuyts G, De Wael K, Dyes And Pigments 189, 109260 (2021). http://doi.org/10.1016/J.DYEPIG.2021.109260
Abstract: Eosin Y has an extraordinary capacity to form complexes with metallic elements, that have applications in many different fields, from photovoltaics and photocatalysis to historical artists? pigments. To unravel the complexes reactivity, it is essential to have a precise knowledge of their structure and composition, as well as how these can be affected by the synthesis protocol, an often underestimated factor. This manuscript presents a thorough investigation of the structure and composition of eosin Y complexes based on Al and Pb, by FTIR, XRPD and Raman spectroscopy, with a particular focus on the effect of the synthesis conditions. Results clearly show the change of the coordination mode in Pb complexes depending on the protocol, while the structure of Al complexes remains stable. In both cases, the formation of by-products was observed. Additionally, a detailed band assignment of the FTIR and Raman spectra of eosin Y and Pb and Al complexes is described, providing interesting details such as the interaction between the metallic ion and the xanthene moiety (chromophore). This is extremely important for the analysis of historical paintings where eosin Y is bonded to metallic ions, as well as for other materials in dye-sensitized solar cells, wastewater treatment or photocatalysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.473
DOI: 10.1016/J.DYEPIG.2021.109260
|
“Practical tool for sampling and fast analysis of large cocaine seizures”. Eliaerts J, Meert N, Van Durme F, Samyn N, De Wael K, Dardenne P, Drug testing and analysis 10, 1039 (2018). http://doi.org/10.1002/DTA.2364
Abstract: Large quantities of illicit drugs are frequently seized by law enforcement. In such cases, a representative number of samples needs to be quickly examined prior to destruction. No procedure has yet been set up which rapidly provides information regarding the homogeneity of the samples, the presence of controlled substances and the degree of purity. This study establishes a protocol for fast analysis of cocaine and its most common cutting agent, levamisole, in large seizures. The protocol is based on a hypergeometric sampling approach combined with FTIR spectrometry and Support Vector Machines (SVM) algorithms as analysis methods. To demonstrate the practical use of this approach, five large cocaine seizures (consisting between 45 and 85 units) were analysed simultaneously with GC-MS, GC-FID and a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling combined with SVM models. According to the hypergeometric sampling plan of the Drugs Working Group ENFSI guidelines, the required number of subsamples ranged between 19 and 23. Considering the identification analyses, the SVM models detected cocaine and levamisole in all subsamples of cases 1 to 5 (100% correct classification), which was confirmed by GC-MS analysis. Considering the quantification analyses, the SVM models were able to estimate the cocaine and levamisole content in each subsample, compared to GC-FID data. The developed strategy is easy, cost effective and provides immediate information about both the presence and concentration of cocaine and levamisole. By using this new strategy, the number of confirmation analyses with laborious and expensive chromatographic techniques could be significantly reduced.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.469
Times cited: 1
DOI: 10.1002/DTA.2364
|
“Rapid classification and quantification of cocaine in seized powders with ATR-FTIR and chemometrics”. Eliaerts J, Dardenne P, Meert N, Van Durme F, Samyn N, Janssens K, De Wael K, Drug testing and analysis 9, 1480 (2017). http://doi.org/10.1002/DTA.2149
Abstract: Traditionally, fast screening for the presence of cocaine in unknown powders is performed by means of colour tests. The major drawbacks of these tests are subjective colour evaluation depending on the operator (50 shades of blue) and a lack of selectivity. An alternative fast screening technique is Fourier Transform InfraRed (FTIR) spectrometry. This technique provides spectra that are difficult to interpret without specialized expertise and showing a lack of sensitivity for the detection of cocaine in mixtures. To overcome these limitations, a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling was combined with a multivariate technique, called Support Vector Machines (SVM). Representative street drug powders (n = 482), seized during the period January 2013 to July 2015, and reference powders (n = 33) were used to build and validate a classification model (n = 515) and a quantification model (n = 378). Both models were compared with the conventional chromatographic techniques. The SVM classification model showed a high sensitivity, specificity and efficiency (99%). The SVM quantification model determined cocaine content with a root mean squared error of prediction (RMSEP) of 6% calculated over a wide working range from 4 to 99 w%. In conclusion, the developed models resulted in a clear output (cocaine detected or cocaine not detected) and a reliable estimation of the cocaine content in a wide variety of mixtures. The ATR-FTIR technique combined with SVM is a straightforward, user-friendly and fast approach for routine classification and quantification of cocaine in seized powders.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.469
Times cited: 9
DOI: 10.1002/DTA.2149
|
“Electrochemical profiling and liquid chromatography–mass spectrometry characterization of synthetic cathinones : from methodology to detection in forensic samples”. Schram J, Parrilla M, Sleegers N, Van Durme F, van den Berg J, van Nuijs ALN, De Wael K, Drug Testing And Analysis 13, 1282 (2021). http://doi.org/10.1002/DTA.3018
Abstract: The emergence of new psychoactive drugs in the market demands rapid and accurate tools for the on‐site classification of illegal and legal compounds with similar structures. Herein, a novel method for the classification of synthetic cathinones (SC) is presented based on their electrochemical profile. First, the electrochemical profile of five common SC (i.e., mephedrone, ethcathinone, methylone, butylone and 4‐chloro‐alpha‐pyrrolidinovalerophenone) is collected to build calibration curves using square wave voltammetry on graphite screen‐printed electrodes (SPE). Second, the elucidation of the oxidation pathways, obtained by liquid chromatography‐high resolution mass spectrometry, allows the pairing of the oxidation products to the SC electrochemical profile, providing a selective and robust classification. Additionally, the effect of common adulterants and illicit drugs on the electrochemical profile of the SC is explored. Interestingly, a cathodic pretreatment of the SPE allows the selective detection of each SC in presence of electroactive adulterants. Finally, the electrochemical approach is validated with gas‐chromatography‐mass spectrometry by analyzing 26 confiscated samples from seizures and illegal webshops. Overall, the electrochemical method exhibits a successful classification of SC including structural derivatives, a crucial attribute in an ever‐diversifying drug market.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre
Impact Factor: 3.469
DOI: 10.1002/DTA.3018
|
“Real-time electrochemical screening of cocaine in lab and field settings with automatic result generation”. de Jong M, Van Echelpoel R, Langley AR, Eliaerts J, van den Berg J, De Wilde M, Somers N, Samyn N, De Wael K, Drug testing and analysis 14, 1471 (2022). http://doi.org/10.1002/DTA.3276
Abstract: This work presents the results of a novel application for the fast on-site screening of cocaine and its main cutting agents in suspicious and confiscated samples. The methodology behind the novel application consists of portable electrochemical detection coupled with a peak-recognition algorithm for automated result output generation, validated both in laboratory and field settings. Currently used field tests, predominantly colorimetric tests, are lacking accuracy, often giving false positive or negative results. This presses the need for alternative approaches to field testing. By combining portable electrochemical approaches with peak-recognition algorithms, an accuracy of 98.4% concerning the detection of cocaine was achieved on a set of 374 powder samples. In addition, the approach was tested on multiple 'smuggled', colored cocaine powders and cocaine mixtures in solid and liquid states, typically in matrices such as charcoal, syrup and clothing. Despite these attempts to hide cocaine, our approach succeeded in detecting cocaine during on-site screening scenarios. This feature presents an advantage over colorimetric and optical detection techniques, which can fail with colored sample matrices. This enhanced accuracy on smuggled samples will lead to increased efficiency in confiscation procedures in the field, thus significantly reducing societal economic and safety concerns and highlighting the potential for electrochemical approaches in on-the-spot identification of drugs of abuse.
Keywords: A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1002/DTA.3276
|
“Design of smart nanoparticles for the electrochemical detection of 3,4-methylenedioxymethamphetamine to allow in field screening by law enforcement officers”. Truta FM, Cruz AG, Dragan A-M, Tertis M, Cowen T, Stefan M-G, Topala T, Slosse A, Piletska E, Van Durme F, Kiss B, De Wael K, Piletsky SA, Cristea C, Drug testing and analysis , 1 (2023). http://doi.org/10.1002/DTA.3605
Abstract: A portable and highly sensitive sensor was designed for the specific detection of 3,4-methyl-enedioxy-methamphetamine (MDMA), in a range of field-testing situations. The sensor can detect MDMA in street samples, even when other controlled substances drugs, or adulterants are present. In this work, we report for the first time a sensor using electroactive molecularly imprinted polymer nanoparticles computationally designed to recognize MDMA and then produced using solid phase synthesis. A composite comprising chitosan, reduced graphene oxide, and molecularly imprinted polymer nanoparticles synthesized for MDMA for the first time was immobilized on screen-printed carbon electrodes. The sensors displayed a satisfactory sensitivity (106.8 nA x mu M-1), limit of detection (1.6 nM; 0.31 ng/mL), and recoveries (92-99%). The accuracy of the results was confirmed through validation using Ultra-High Performance Liquid Chromatography coupled with tandem Mass Spectrometry (UPLC-MS/MS). This technology could be used in forensic analysis and make it possible to selectively detect MDMA in street samples. A highly sensitive and portable sensor has been developed to detect MDMA in street samples. It uses electroactive molecularly imprinted polymer nanoparticles computationally designed to recognize MDMA, which were immobilized on screen-printed carbon electrodes with chitosan and graphene. The sensor showed good sensitivity and satisfactory recoveries (92-99%), confirmed with UPLC-MS/MS validation. This technology has the potential to be used in forensic analysis.image
Keywords: A1 Journal article; Pharmacology. Therapy; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 2.9
DOI: 10.1002/DTA.3605
|
“Evaluation of an electrochemical sensor and comparison with spectroscopic approaches as used today in practice for harm reduction in a festival setting: a case study : analysis of 3,4-methylenedioxymethamphetamine samples”. Deconinck E, Polet MA, Canfyn M, Duchateau C, De Braekeleer K, Van Echelpoel R, De Wael K, Gremeaux L, Degreef M, Balcaen M, Drug testing and analysis , 1 (2023). http://doi.org/10.1002/DTA.3625
Abstract: More and more countries and organisations emphasise the value of harm reduction measures in the context of illicit drug use and abuse. One of these measures is drug checking, a preventive action that can represent a quick win by tailored consultation on the risks of substance use upon analytical screening of a submitted sample. Unlike drop-in centres that operate within a fixed setting, enabling drug checking in a harm reduction context at events requires portable, easy to use analytical approaches, operated by personnel with limited knowledge of analytical chemistry. In this case study, four different approaches were compared for the characterisation of 3,4-methylenedioxymethamphetamine samples and this in the way the approaches would be applied today in an event context. The four approaches are mid-infrared (MIR), near-infrared, and Raman spectroscopy, which are today used in drug checking context in Belgium, as well as an electrochemical sensor approach initially developed in the context of law enforcement at ports. The MIR and the electrochemical approach came out best, with the latter allowing for a direct straightforward analysis of the percentage 3,4-methylenedioxymethamphetamine (as base equivalent) in the samples. However, MIR has the advantage that, in a broader drug checking context, it allows to screen for several molecules and so is able to identify unexpected active components or at least the group to which such components belong. The latter is also an important advantage in the context of the growing emergence of new psychotropic substances. MIR, NIR, Raman spectroscopy, and an electrochemical sensor (Narcoreader (R)) for MDMA analysis were compared in a realistic harm reduction context. NIR and Raman failed in simple library approaches. MIR and Narcoreader (R) were preferred. MIR came out as first choice. MIR and Narcoreader (R) have complementary (dis)advantages and could be used in a two-step approach: MIR for screening and Narcoreader (R) for dosage/risk evaluation of MDMA samples.image
Keywords: A1 Journal article; Pharmacology. Therapy; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 2.9
DOI: 10.1002/DTA.3625
|
“X-Ray Fluorescence as an analytical tool for studying the copper matrices in the collection of the Museum Plantin-Moretus”. Storme P, Fransen E, De Wael K, Caen J, De gulden passer 95, 7 (2017)
Keywords: A1 Journal article; Engineering sciences. Technology; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
“Synthesis and characterization of heteroleptic rare earth double-decker complexes involving tetradiazepinoporphyrazine and phthalocyanine macrocycles”. Tarakanova EN, Tarakanov PA, Simakov AO, Furuyama T, Kobayashi N, Konev DV, Goncharova OA, Trashin SA, De Wael K, Sulimenkov IV, Filatov VV, Kozlovskiy VI, Tomilova LG, Stuzhin PA, Pushkarev VE, Dalton Transactions 50, 6245 (2021). http://doi.org/10.1039/D1DT00088H
Abstract: Reaction of (2,3,9,10,16,17,23,24-octabutylphthalocyaninato)lanthanide(iii) acetylacetonates ((Bu)PcLn(acac), 1a-c, Ln = Lu (a), Eu (b), La (c)) with a tetrakis(5,7-bis(4-tert-butylphenyl)-6H-1,4-diazepino)[2,3-b,g,l,q]porphyrazine ligand ((tBuPh)DzPzH(2), 2) produced sandwich compounds ((tBuPh)DzPz)Ln(Pc-Bu) (3a-c), which represent the first heteroleptic double-deckers incorporating both Pc and DzPz decks. A combination of high-resolution mass spectrometry, UV-Vis/NIR, MCD, and H-1 NMR spectroscopy, and square-wave voltammetry provided unambiguous characterization of target complexes 3 indicating that their spectral and electrochemical properties are generally intermediate with respect to their homoleptic relatives. Based on the data of solution-state H-1-H-1 NMR (COSY, NOESY) correlation spectroscopy supported by DFT calculations, a dimerization tendency of compounds 3 proportional to the Ln(iii) ion size was found. The spectroelectrochemical study of 3 and the corresponding homoleptic double-deckers revealed a pronounced tendency to aggregation of the one-electron oxidized forms of DzPz-containing double-decker complexes compared to homoleptic Pc(2)Ln compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.029
DOI: 10.1039/D1DT00088H
|
“Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics”. Bottari F, Blust R, De Wael K, Current opinion in electrochemistry 10, 143 (2018). http://doi.org/10.1016/J.COELEC.2018.05.016
Abstract: The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1016/J.COELEC.2018.05.016
|
“Challenges in the electrochemical (bio)sensing of non-electroactive food and environmental contaminants”. Moro G, De Wael K, Moretto LM, Current opinion in electrochemistry 16, 57 (2019). http://doi.org/10.1016/J.COELEC.2019.04.019
Abstract: The electrochemical detection of non-electroactive contaminants can be successfully faced via the use of indirect detection strategies. These strategies can provide sensitive and selective responses often coupled with portable and user-friendly analytical tools. Indirect detection strategies are usually based on the change in the signal of an electroactive probe, induced by the presence of the target molecule at a modified electrode. This critical review aims at addressing the developments in indirect electro-sensing strategies for non-electroactive contaminants in food and environmental analysis in the last years (2017-2019). Emphasis is given to the strategy design, the electrode modifiers used and the feasibility of technological transfer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 4
DOI: 10.1016/J.COELEC.2019.04.019
|
“Electrochemical strategies for the detection of forensic drugs”. Florea A, De Jong M, De Wael K, Current opinion in electrochemistry 11, 34 (2018). http://doi.org/10.1016/J.COELEC.2018.06.014
Abstract: Illicit drugs consumption and trafficking is spread worldwide and remains an increasing challenge for local authorities. Forensic drugs and their metabolites are released into wastewaters due to human excretion after illegal consumption of drugs and occasionally due to disposal of clandestine laboratory wastes into sewage systems, being recently classified as the latest group of emerging pollutants. Hence, it is essential to have efficient and accurate methods to detect these type of compounds in seized street samples, biological fluids and wastewaters in order to reduce and prevent trafficking and consumption and negative effects on aquatic systems. Electrochemical strategies offer a fast, portable, low-cost and accurate alternative to chromatographic and spectrometric methods, for the analysis of forensic drugs and metabolites in different matrices. Recent electrochemical strategies applied to the detection of illicit drugs in wastewaters, biological fluids and street samples are presented in this review, together with the impact of drug consumption on the environment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 7
DOI: 10.1016/J.COELEC.2018.06.014
|
“(Electro)sensing of phenicol antibiotics : a review”. Pilehvar S, Gielkens K, Trashin SA, Dardenne F, Blust R, De Wael K, Critical reviews in food science and nutrition 56, 2416 (2016). http://doi.org/10.1080/10408398.2013.845140
Abstract: The presence of residues from frequent antibiotic use in animal feed can cause serious health risks by contaminating products for human consumption such as meat and milk. The present article gives an overview of the electrochemical methods developed for the detection of phenicol antibiotic residues (chloramphenicol, thiamphenicol, and florfenicol) in different kinds of foodstuffs. Electrochemical sensors based on different biomolecules and nanomaterials are described. The detection limit of various developed methods with their advantages and disadvantage will be highlighted.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.077
Times cited: 13
DOI: 10.1080/10408398.2013.845140
|
“Photoelectrochemistry for measuring the photocatalytic activity of soluble photosensitizers”. Khan SU, Trashin SA, Korostei YS, Dubinina TV, Tomilova LG, Verbruggen SW, De Wael K, ChemPhotoChem 4, 300 (2020). http://doi.org/10.1002/CPTC.201900275
Abstract: We introduce a rapid method to test the photocatalytic activity of singlet‐oxygen‐producing photosensitizers using a batch cell, a LED laser and a conventional potentiostat. The strategy is based on coupling of photo‐oxidation of hydroquinone and simultaneous electrochemical reduction of its oxidized form at a carbon electrode in an organic solvent (methanol). This scheme gives an immediate response and avoids complications related to long‐term experiments such as oxidative photo‐degradation of photosensitizers and singlet oxygen traps by reactive oxygen species (ROS). Among the tested compounds, a fluoro‐substituted subphthalocyanine showed the highest photocurrent and singlet oxygen quantum yield (ΦΔ) in comparison to phenoxy‐ and tert‐butyl‐substituted analogues, whereas the lowest photocurrents and yields were observed for aggregated and dimeric phthalocyanine complexes. The method is useful for fast screening of the photosensitizing activity and represents the first example of one‐pot coupling of electrochemical and photocatalytic reactions in organic media.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL)
Impact Factor: 3.7
Times cited: 1
DOI: 10.1002/CPTC.201900275
|
“Leaf-deposited semi-volatile organic compounds (SVOCs) : an exploratory study using GCxGC-TOFMS on leaf washing solutions”. Castanheiro A, Joos P, Wuyts K, De Wael K, Samson R, Chemosphere 214, 103 (2019). http://doi.org/10.1016/J.CHEMOSPHERE.2018.09.067
Abstract: Airborne particulate matter (PM) includes semi-volatile organic compounds (SVOCs), which can be deposited on vegetation matrices such as plant leaves. In alternative to air-point measurements or artificial passive substrates, leaf monitoring offers a cost-effective, time-integrating means of assessing local air quality. In this study, leaf washing solutions from ivy (Hedera hibernica) leaves exposed during one-month at different land use classes were explored via comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GCxGC-TOFMS). The composition of leaf-deposited SVOCs, corrected for those of unexposed leaves, was compared against routinely monitored pollutants concentrations (PM10, PM2.5, O3, NO2, SO2) measured at co-located air monitoring stations. The first study on leaf-deposited SVOCs retrieved from washing solutions, herein reported, delivered a total of 911 detected compounds. While no significant land use (rural, urban, industrial, traffic, mixed) effects were observed, increasing exposure time (from one to 28 days) resulted in a higher number and diversity of SVOCs, suggesting cumulative time-integration to be more relevant than local source variations between sites. After one day, leaf-deposited SVOCs were mainly due to alcohols, N-containing compounds, carboxylic acids, esters and lactones, while ketones, diketones and hydrocarbons compounds gained relevance after one week, and phenol compounds after one month. As leaf-deposited SVOCs became overall more oxidized throughout exposure time, SVOCs transformation or degradation at the leaf surface is suggested to be an important phenomenon. This study confirmed the applicability of GCxGC-TOFMS to analyze SVOCs from leaf washing solutions, further research should include validation of the methodology and comparison with atmospheric organic pollutants.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.208
DOI: 10.1016/J.CHEMOSPHERE.2018.09.067
|
“Precision and accuracy of ST-EDXRF performance for As determination comparing with ICP-MS and evaluation of As deviation in the soil media”. Akbulut S, Cevik U, Van AA, De Wael K, Van Grieken R, Chemosphere 96, 16 (2014). http://doi.org/10.1016/J.CHEMOSPHERE.2013.06.086
Abstract: The present study was conducted to (i) determine the precision and accuracy of arsenic measurement in soil samples using ST-EDXRF by comparison with the results of ICP-MS analyses and (ii) identify the relationship of As concentration with soil characteristics. For the analysis of samples, inductively coupled plasma mass spectrometry (ICP-MS) and energy dispersive X-ray fluorescence spectrometry (EDXRF) were performed. According to the results found in the soil samples, the addition of HCl to HNO3, used for the digestion gave significant variations in the recovery of As. However, spectral interferences between peaks for As and Pb can affect detection limits and accuracy for XRF analysis. When comparing the XRF and ICP-MS results a correlation was observed with R2 = 0.8414. This means that using a ST-EDXRF spectrometer, it is possible to achieve accurate and precise analysis by the calibration of certified reference materials and choosing an appropriate secondary target. On the other hand, with regard to soil characteristics analyses, the study highlighted that As is mostly anthropogenically enriched in the studied area.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.208
Times cited: 5
DOI: 10.1016/J.CHEMOSPHERE.2013.06.086
|
“Unique properties of core shell Ag@Au nanoparticles for the aptasensing of bacterial cells”. Hamidi-Asl E, Dardenne F, Pilehvar S, Blust R, De Wael K, Chemosensors 4, 16 (2016). http://doi.org/10.3390/CHEMOSENSORS4030016
Abstract: In this article, it is shown that the efficiency of an electrochemical aptasensing device is influenced by the use of different nanoparticles (NPs) such as gold nanoparticles (Au), silver nanoparticles (Ag), hollow gold nanospheres (HGN), hollow silver nanospheres (HSN), silvergold core shell (Ag@Au), goldsilver core shell (Au@Ag), and silvergold alloy nanoparticles (Ag/Au). Among these nanomaterials, Ag@Au core shell NPs are advantageous for aptasensing applications because the core improves the physical properties and the shell provides chemical stability and biocompatibility for the immobilization of aptamers. Self-assembly of the NPs on a cysteamine film at the surface of a carbon paste electrode is followed by the immobilization of thiolated aptamers at these nanoframes. The nanostructured (Ag@Au) aptadevice for Escherichia coli as a target shows four times better performance in comparison to the response obtained at an aptamer modified planar gold electrode. A comparison with other (core shell) NPs is performed by cyclic voltammetry and differential pulse voltammetry. Also, the selectivity of the aptasensor is investigated using other kinds of bacteria. The synthesized NPs and the morphology of the modified electrode are characterized by UV-Vis absorption spectroscopy, scanning electron microscopy, energy dispersive X-ray analysis, and electrochemical impedance spectroscopy.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 9
DOI: 10.3390/CHEMOSENSORS4030016
|
“Rapid on-site detection of illicit drugs in smuggled samples with a portable electrochemical device”. Parrilla M, Slosse A, Van Echelpoel R, Montiel FN, Langley AR, Van Durme F, De Wael K, Chemosensors 10, 108 (2022). http://doi.org/10.3390/CHEMOSENSORS10030108
Abstract: The smuggling of illicit drugs urges the development of new tools for rapid on-site identification in cargos. Current methods rely on presumptive color tests and portable spectroscopic techniques. However, these methods sometimes exhibit inaccurate results due to commonly used cutting agents, the colorful nature of the sample or because the drugs are smuggled in common goods. Interestingly, electrochemical sensors can deal with these specific problems. Herein, an electrochemical device is presented that uses affordable screen-printed electrodes for the electrochemical profiling of several illicit drugs by square-wave voltammetry (SWV). The identification of the illicit compound is based on the oxidation potential of the analyte. Hence, a library of electrochemical profiles is built upon the analysis of illicit drugs and common cutting agents. This library allows the design of a tailor-made script that enables the identification of each drug through a user-friendly interface (laptop or mobile phone). Importantly, the electrochemical test is compared by analyzing 48 confiscated samples with other portable devices based on Raman and FTIR spectroscopy as well as a laboratory standard method (i.e., gas chromatography-mass spectrometry). Overall, the electrochemical results, obtained through the analysis of different samples from confiscated cargos at an end-user site, present a promising alternative to current methods, offering low-cost and rapid testing in the field.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.3390/CHEMOSENSORS10030108
|
“Selectivity in ligand functionalization of photocatalytic metal oxide nanoparticles for phase transfer and self‐assembly applications”. Borah R, Ninakanti R, Nuyts G, Peeters H, Pedrazo-Tardajos A, Nuti S, Vande Velde C, De Wael K, Lenaerts S, Bals S, Verbruggen S, Chemistry-A European Journal , chem.202100029 (2021). http://doi.org/10.1002/CHEM.202100029
Abstract: Functionalization of photocatalytic metal oxide nanoparticles of TiO 2 , ZnO, WO 3 and CuO with amine‐terminated (oleylamine) and thiol‐terminated (1‐dodecanethiol) alkyl chained ligands was studied under ambient conditions. A high selectivity was observed in the binding specificity of a ligand towards nanoparticles of these different oxides. It was observed that oleylamine binds stably to only TiO 2 and WO 3 , while 1‐dodecanethiol binds stably only to ZnO and CuO. Similarly, polar to non‐polar solvent phase transfer of TiO 2 and WO 3 nanoparticles could be achieved by using oleylamine, but not by 1‐dodecanethiol, while the contrary holds for ZnO and CuO. The surface chemistry of ligand functionalized nanoparticles was probed by ATR‐FTIR spectroscopy, that enabled to elucidate the occupation of the ligands at the active sites. The photo‐stability of the ligands on the nanoparticle surface was determined by the photocatalytic self‐cleaning properties of the material. While TiO 2 and WO 3 degrade the ligands within 24 hours under both UV and visible light, ligands on ZnO and CuO remain unaffected. The gathered insights are also highly relevant from an application point of view. As an example, since the ligand functionalized nanoparticles are hydrophobic in nature, they can thus be self‐assembled at the air‐water interface, for obtaining nanoparticle films with demonstrated photocatalytic as well as anti‐fogging properties.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL); Intelligence in PRocesses, Advanced Catalysts and Solvents (iPRACS)
Impact Factor: 5.317
Times cited: 15
DOI: 10.1002/CHEM.202100029
|
“Unraveling the Role of Lattice Substitutions on the Stabilization of the Intrinsically Unstable Pb2Sb2O7Pyrochlore: Explaining the Lightfastness of Lead Pyroantimonate Artists&rsquo, Pigments”. Marchetti A, Saniz R, Krishnan D, Rabbachin L, Nuyts G, De Meyer S, Verbeeck J, Janssens K, Pelosi C, Lamoen D, Partoens B, De Wael K, Chemistry Of Materials 32, 2863 (2020). http://doi.org/10.1021/acs.chemmater.9b04821
Abstract: The pyroantimonate pigments Naples yellow and lead tin antimonate yellow are recognized as some of the most stable synthetic yellow pigments in the history of art. However, this exceptional lightfastness is in contrast with experimental evidence suggesting that this class of mixed oxides is of semiconducting nature. In this study the electronic structure and light-induced behavior of the lead pyroantimonate pigments were determined by means of a combined multifaceted analytical and computational approach (photoelectrochemical measurements, UV-vis diffuse reflectance spectroscopy, STEM-EDS, STEM-HAADF, and density functional theory calculations). The results demonstrate both the semiconducting nature and the lightfastness of these pigments. Poor optical absorption and minority carrier mobility are the main properties responsible for the observed stability. In addition, novel fundamental insights into the role played by Na atoms in the stabilization of the otherwise intrinsically unstable Pb2Sb2O7 pyrochlore were obtained.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT)
Impact Factor: 8.6
Times cited: 8
DOI: 10.1021/acs.chemmater.9b04821
|
“Technoques and applications of Surface-Enhanced Raman Scattering Spectroscopy (SERSS) focused on cultural heritage”. Kuckova S, Hamidi-Asl E, Matulkova I, Hynek R, De Wael K, Sanyova J, Janssens K, Chemické, listy 112, 312 (2018)
Abstract: The review is devoted to a modern method of vibrational spectroscopy – surface enhanced Raman spectroscopy Its principle and some of its special variants (imunnoSERS and TERS (Tip-Enhanced Raman Spectroscopy)) are described m a simpinified manner Wide application possibilities are demonstrated on selected examples from its application m culturinl heritage.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 0.387
|
“Electrochemical fingerprint of street samples for fast on-site screening of cocaine in seized drug powders”. De Jong M, Sleegers N, Kim J, Van Durme F, Samyn N, Wang J, De Wael K, Chemical science , 1 (2016). http://doi.org/10.1039/C5SC04309C
Abstract: We report on a wearable fingertip sensor for on-the-spot identification of cocaine and its cutting agents in street samples. Traditionally, on-site screening is performed by means of colour tests which are difficult to interpret and lack selectivity. By presenting the distinct voltammetric response of cocaine, cutting agents, binary mixtures of cocaine and street samples in solution and powder street samples, we were able to elucidate the electrochemical fingerprint of all these compounds. The new electrochemical concept holds considerable promise as an on-site screening method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.668
Times cited: 37
DOI: 10.1039/C5SC04309C
|
“The application of an electrochemical microflow reactor for the electrosynthetic aldol reaction of acetone to diacetone alcohol”. Pauwels D, Geboes B, Hereijgers J, Choukroun D, De Wael K, Breugelmans T, Chemical engineering research and design 128, 205 (2017). http://doi.org/10.1016/J.CHERD.2017.10.014
Abstract: The design and application of an electrochemical micro-flow reactor for the aldol reaction of acetone to diacetone alcohol (DAA) is reported. The modular reactor could be readily disassembled and reassembled to change the electrodes, incorporate a membrane and remove possible obstructions. The productivity and efficiency was quantified. Using a platinum deposit as electrocatalyst or an inert glassy carbon electrode as working electrode, the maximum obtainable equilibrium concentration of ±15 m% was reached after a single pass up to a flow rate of 8 ml min−1, yielding 0.57 g min−1 DAA (3.46 mmol cm−3 min−1) at an efficiency of 0.33 g C−1 on platinum and 0.50 g min−1 (3.04 mmol cm−3 min−1) at 1.20 g C−1 on glassy carbon. Note that no optimisation studies have been made in the present paper.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 2.538
Times cited: 2
DOI: 10.1016/J.CHERD.2017.10.014
|
“Investigation of the electrosynthetic pathway of the aldol condensation of acetone”. Pauwels D, Hereijgers J, Verhulst K, De Wael K, Breugelmans T, Chemical engineering journal 289, 554 (2016). http://doi.org/10.1016/J.CEJ.2016.01.018
Abstract: The potential-controlled electrochemical aldol condensation of acetone to diacetone alcohol in a standard batch electrolysis set-up was studied in this work. It is confirmed that the reaction proceeds at the cathode and that, contrary to what is mentioned in earlier literature, water in the electrolyte has a disadvantageous effect on the reaction. Similar to the chemical reaction, the electrochemical reaction reaches a maximum yield when the equilibrium is reached. Separating the anode and cathode prevents cross-over and degradation of products, leading to a higher yield. Starting with pure acetone and support electrolyte, it was possible to obtain a diacetone alcohol concentration of 15 m% after two hours electrolysis in a divided set-up with a platinum electrode at -2.5 V. The concentration gradient throughout the electrolysis follows an exponential curve up to its equilibrium concentration.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Applied Electrochemistry & Catalysis (ELCAT)
Impact Factor: 6.216
Times cited: 6
DOI: 10.1016/J.CEJ.2016.01.018
|
“Tuning the turnover frequency and selectivity of photocatalytic CO2 reduction to CO and methane using platinum and palladium nanoparticles on Ti-Beta zeolites”. Blommaerts N, Hoeven N, Arenas Esteban D, Campos R, Mertens M, Borah R, Glisenti A, De Wael K, Bals S, Lenaerts S, Verbruggen SW, Cool P, Chemical Engineering Journal 410, 128234 (2021). http://doi.org/10.1016/j.cej.2020.128234
Abstract: A Ti-Beta zeolite was used in gas phase photocatalytic CO2 reduction to reduce the charge recombination rate and increase the surface area compared to P25 as commercial benchmark, reaching 607 m2 g-1. By adding Pt nanoparticles, the selectivity can be tuned toward CO, reaching a value of 92% and a turnover frequency (TOF) of 96 µmol.gcat-1.h-1, nearly an order of magnitude higher in comparison with P25. By adding Pd nanoparticles the selectivity can be shifted from CO (70% for a bare Ti-Beta zeolite), toward CH4 as the prevalent species (60%). In this way, the selectivity toward CO or CH4 can be tuned by either using Pt or Pd. The TOF values obtained in this work outperform reported state-of-the-art values in similar research. The improved activity by adding the nanoparticles was attributed to an improved charge separation efficiency, together with a plasmonic contribution of the metal nanoparticles under the applied experimental conditions.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL); Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.216
Times cited: 15
DOI: 10.1016/j.cej.2020.128234
|
“Attaching redox proteins onto electrode surfaces by bis-silane”. Trashin S, De Jong M, Meynen V, Dewilde S, De Wael K, ChemElectroChem 3, 1035 (2016). http://doi.org/10.1002/CELC.201600021
Abstract: Immobilization of redox proteins on electrode surfaces is of special interest for mechanistic studies and applications because of a well-controlled redox state of protein molecules by a polarized electrode and fast electron transfer kinetics, free from diffusion limitation. Here, bis-organosilane (1,2-bis(trimethoxysilyl)ethane) was applied as a fresh solution in a pH 7 phosphate buffer without use of any organic solvent, sol-gel or mesoporous bulk matrix. A short aging period of 30 minutes before deposition on the electrodes was optimal for the immobilization of proteins. Three redox proteins (cytochrome c, neuroglobin and GLB-12) were confined to the gold surface of electrodes with high coverages and stability, indicating that the suggested technique is simple, efficient and generic in nature.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.136
Times cited: 4
DOI: 10.1002/CELC.201600021
|