|
“Material analysis methods applied to the study of ancient monuments, works of art and artefacts”. Delalieux F, Tsuji K, Wagatsuma K, Van Grieken R, Materials transactions 43, 2197 (2002). http://doi.org/10.2320/MATERTRANS.43.2197
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2320/MATERTRANS.43.2197
|
|
|
“EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials”. Belikov KN, Mikhailova LI, Spolnik ZM, Van Grieken R, X-ray spectrometry 35, 112 (2006). http://doi.org/10.1002/XRS.874
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.874
|
|
|
“Comparison of limestone, dolomite and fly ash as pre-treatment agents for acid mine drainage”. Potgieter-Vermaak SS, Potgieter JH, Monama P, Van Grieken R, Minerals engineering 19, 454 (2006). http://doi.org/10.1016/J.MINENG.2005.07.009
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MINENG.2005.07.009
|
|
|
“Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy: energy-dispersive X-ray spectrometry”. Choël M, Deboudt K, Osán J, Flament P, Van Grieken R, Analytical chemistry 77, 5686 (2005). http://doi.org/10.1021/AC050739X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC050739X
|
|
|
“Preconcentration and XRF-determination of heavy metals in hair from Sudanese populations”. Eltayeb MAH, Van Grieken RE, Journal of radioanalytical and nuclear chemistry 131, 331 (1989). http://doi.org/10.1007/BF02060598
Abstract: Energy-dispersive X-ray fluorescence analysis was applied for the analysis of hair. The hair samples were digested in a mixture of nitric and perchloric acid and the heavy metals were precipitated with ammonium pyrrolidine dithiocarbamate. The accuracy, precision and recovery of the method for the elements Fe, Ni, Cu, Zn and Pb were evaluated through the analysis of a standard hair sample. The procedure was applied to the analysis of hair from an occupationally exposed group of Sudanese workers and a control group. The hair of the exposed group showed a range of 80550 ppm Fe, 612 ppm Cu, 57190 ppm Zn and 703700 ppm Pb, while that of the control group had a range of 60310 ppm Fe, 722 ppm Cu, 89170 ppm Zn and 317 ppm Pb.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02060598
|
|
|
“Analysis of lateritic material from Cerro impacto by instrumental neutron activation employing a low-energy photon semiconductor and a high-energy Ge(Li) detector”. LaBrecque JJ, Beusen JM, Van Grieken RE, Applied spectroscopy 40, 140 (1986). http://doi.org/10.1366/0003702864509600
Abstract: Nineteen elements were determined in four different grain size fractions of a bulk geological material from Cerro Impacto for a study of the physical (mechanical) concentration process of different elements based upon the hardness of the different minerals. The analysis was performed by excitation of the sample with a high, slow neutron flux followed by gamma-ray spectroscopy with both a conventional Ge(Li) high-energy detector and a low-energy photon detector (LEPD). The accuracy of this method was studied with the use of two standard reference materials, SY-2 and SY-3, which are similar to the real samples. The values determined were also compared with a secondary target x-ray fluorescence method for all the elements that were suitable to both methods. Actually, the x-ray fluorescence method was found to be more complementary than competitive.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702864509600
|
|
|
“Detection of a Ca-rich lithology in the Earth's deep (>, 300 km) convecting mantle”. Brenker FE, Vincze L, Vekemans B, Nasdala L, Stachel T, Vollmer C, Kersten M, Somogyi A, Adams F, Joswig W, Harris JW, Earth and planetary science letters 236, 579 (2005). http://doi.org/10.1016/J.EPSL.2005.05.021
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.EPSL.2005.05.021
|
|
|
“A characterisation of the surface properties of an ultra fine fly ash (UFFA) used in the polymer industry”. Potgieter-Vermaak SS, Potgieter JH, Kruger RA, Spolnik Z, Van Grieken R, Fuel 84, 2295 (2005). http://doi.org/10.1016/J.FUEL.2005.05.013
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.FUEL.2005.05.013
|
|
|
“Immunoreactivity for P-170 glycoprotein in malignant mesothelioma and in non-neoplastic mesothelium of the pleura using the murine monoclonal antibody JSB-1”. Ramael M, van den Bossche J, Buysse C, van Meerbeeck J, Segers K, Vermeire P, Van Marck E, The journal of pathology 167, 5 (1992). http://doi.org/10.1002/PATH.1711670103
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/PATH.1711670103
|
|
|
“Immunoreactivity for p53 protein in malignant mesothelioma and non-neoplastic mesothelium”. Ramael M, Lemmens G, Eerdekens C, Buysse C, Deblier I, Jacobs W, Van Marck E, The journal of pathology 168, 371 (1992). http://doi.org/10.1002/PATH.1711680406
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/PATH.1711680406
|
|
|
Ramael M, van den Bossche J, Buysse C, Van Marck E (1992) Nucleolar organizer regions in mesothelial proliferations. 435
Keywords: L1 Letter to the editor; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.1002/PATH.1711670414
|
|
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
|
|
“Laser microprobe mass spectrometric identification of cyclosporine-induced intrarenal microliths in rat”. Verbueken AH, Van Grieken RE, Verpooten GA, de Broe ME, Wedeen RP, Biological mass spectrometry 21, 590 (1992). http://doi.org/10.1002/BMS.1200211111
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200211111
|
|
|
“Characterization of the spheroliths present in primary atypical bandkeratopathy using laser microprobe mass analysis”. Vandeputte DF, Van Grieken RE, Foets BJJ, Misotten L, Biomedical and environmental mass spectrometry 18, 753 (1989). http://doi.org/10.1002/BMS.1200180918
Abstract: Laser microprobe mass analysis was applied to study the chemical composition of spheroliths in the Bowman's membrane of patients suffering from primary atypical bandkeratopathy. The inclusions appear to consist mainly of calcium phosphate.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200180918
|
|
|
“Ultrastructural localization of aluminium in liver of aluminium maltol-treated rabbits by laser microprobe mass analysis”. Vandeputte D, Van Grieken RE, Jacob WA, Savory J, Bertholf RL, Wills MR, Biomedical and environmental mass spectrometry 18, 598 (1989). http://doi.org/10.1002/BMS.1200180815
Abstract: By means of laser microprobe mass analysis (LAMMA), we have studied the ultrastructural localization of aluminium in livers of aluminium maltol-treated rabbits. This animal model was developed to study long-term aluminium toxicity using systemic (intravenous) administration of aluminium. We could only detect aluminium in electron-dense inclusion bodies found in large, sometimes multinucleated cells. These results prove that the actual observation of aluminium deposits in liver with LAMMA gives more information than bulk analysis and can be very useful to explore mechanisms of toxicity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200180815
|
|
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
|
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
|
|
“Automated matrix-correction of line ratios in energy-dispersive x-ray fluorescence spectrum deconvolution”. Van Dyck P, Van Grieken R, X-ray spectrometry 12, 111 (1983). http://doi.org/10.1002/XRS.1300120306
Abstract: Most computer XRF-spectrum deconvolution routines make use of fixed intensity ratios for the lines from one element. The magnitude of the error that fixed ratios imply has been quantitatively evaluated for samples with a varible thickness or matrix. A procedure for routinely adapting the line ratios according to the matrix effect in every sample (by making use of the matrix information present in the scatter peaks) enhances the accuracy of the spectrum evaluation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300120306
|
|
|
“Automatic absorption correction in x-ray fluorescence analysis of intermediate thickness samples using a dual external reference signal”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 9, 70 (1980). http://doi.org/10.1002/XRS.1300090209
Abstract: A method has been investigated which allows calculations from the X-ray fluorescence spectra of the absorption coefficients at any energy for any sample, without any additional measurement. Use is made of the ratio of the characteristic X-ray signals from a Zr wire positioned in front of the sample and from a Pd foil placed behind the sample, both in a fixed geometry. From the experimentally measured absorption coefficient at the Pd L energy (2.9 keV), the coefficients for higher energies are calculated. By the use of an iterative computer routine in which corrections for the enhancement of the Pd foil by the sample are also included, an accuracy of 2% or better on the absorption coefficient determination can be reached for homogenous samples in one measurement. Grain-size and heterogeneity effects induce inaccuracies on the absorption coefficient determinations which might well reach 20% for particulate samples like intermediate thickness deposits of geological materials. This approach thus has the same limitations as the classical transmission method for such heterogeneous samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090209
|
|
|
“Current trends in the literature on X-ray emission spectrometry”. Van Grieken R, Markowicz A, Veny P, X-ray spectrometry 20, 271 (1991). http://doi.org/10.1002/XRS.1300200605
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300200605
|
|
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“EDXRS study of aerosol composition variations in air masses crossing the North Sea”. Injuk J, van Malderen H, Van Grieken R, Swietlicki E, Knox JM, Schofield R, X-ray spectrometry 22, 220 (1993). http://doi.org/10.1002/XRS.1300220410
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300220410
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“Heterogeneity effects in direct X-ray fluorescence analysis of hair”. Török S, Van Dyck P, Van Grieken R, X-ray spectrometry 13, 27 (1984). http://doi.org/10.1002/XRS.1300130106
Abstract: The methodology of direct hair analysis by energy-dispersive x-ray fluorescence was studied. The effect on the XRF result of having a non-homogeneous radial distribution of the analyte in a single hair strand and the macroscopic effects in a bundle of hairs were calculated to evaluate possible systematic errors. The detection limits were mapped as a function of the target thickness and surface fraction. It appeared that a 10 mg cm−2 sample thickness, i. e. a target with about four layers of hair strands, is recommended. The standard deviation of this simple direct analytical method is 619% for some important elements. Discrepancies with neutron activation analysis had a mean value of around 15%. About twelve elements can be determined simultaneously on a routine basis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300130106
|
|
|
“Heterogeneity effects in direct XRF analysis of traces of heavy metals preconcentrated on polyurethane foam sorbents”. Török S, Braun T, Van Dyck P, Van Grieken R, X-ray spectrometry 15, 7 (1986). http://doi.org/10.1002/XRS.1300150104
Abstract: Trace amounts of heavy metals were preconcentrated on discs of polyurethane (PU) foam loaded with ammonium diethyldithiocarbamate (DDTC), to increase the sensitivity of XRF. Since the diameter of the cavities in the open-cell PU foams reaches 30300 μm, considerable heterogeneity effects might occur, which could reduce the accuracy of the method. The possible systematic error introduced by considering the sample to be homogeneous is calculated using the Berry et al. model. The calculations show that the underestimation of the absorption correction factor when considering the sample as being homogeneous is less than 2% for high-Z elements when the sample thickness is at least 2 mm. The detection limits are also around the minima for this thickness.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150104
|
|
|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
|
|
“Laser microprobe mass spectrometry of platinum in dog kidney after cisplatin adminstration”. Verbueken AH, Van Grieken RE, Paulus GJ, Verpooten GA, de Broe ME, Biomedical mass spectrometry 11, 159 (1984). http://doi.org/10.1002/BMS.1200110404
Abstract: By means of laser microprobe mass analysis (LAMMA) platinum was detected in the renal proximal tubular cells of a dog that had been intravenously adminstered the antitumor drug cisplatin (5 mg per kg body weight). No definite subcellular localization of the heavy metal was obtained. Sample prparation and analytical features are examined to increase spatial resolution of analysis while maintaining sufficient detection efficiency. The LAMMA method is destructive, but the amount and type of evaporated material can readily be determined when using LAMMA in combination with transmission electron microscopy. Instrumental optimization and standardization of mass signals is possible by using platinum-loaded, ion chelating resin beads embedded and sectioned with the tissue.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200110404
|
|