|
“Inorganic deterioration affecting the Altamira Cave, N Spain: quantitative approach to wall-corrosion (solutional etching) processes induced by visitors”. Sánchez-Moral S, Soler V, Cañaveras JC, Sanz-Rubio E, Van Grieken R, Gysels K, The science of the total environment 243/244, 67 (1999). http://doi.org/10.1016/S0048-9697(99)00348-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(99)00348-4
|
|
|
“Interference technique in grazing-emission electron probe microanalysis of submicrometer particles”. Bekshaev A, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 56, 503 (2001). http://doi.org/10.1016/S0584-8547(01)00177-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00177-X
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Molecular ion distributions in laser microprobe mass-spectrometry of calcium-oxide and calcium salts”. Bruynseels FJ, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 38, 853 (1983). http://doi.org/10.1016/0584-8547(83)80184-0
Abstract: Laser Microprobe Mass Spectrometry (LAMMA) is used to examine micrometric particles of calcium oxyanion salts (CaCO3, CaSO4, CaSO4·2H2O) and calcium oxide, in both the positive and negative ion mode. The major molecular ions, appearing in the positive mass spectrum, can be divided into three series, namely CamOm-1+, (CaO)m+ and (CaO)mH+ (m = 1-4). In the case of the former two series the relative intensities of the mass peaks as a function of the fragment valence K = (1 + 2n)/m, for CamOn+, can be fitted to a Gaussian distribution curve, as was earlier demonstrated for secondary ion mass spectrometry. The high stability of the (CaO)mH+ series can be explained by the favourable fragment valence of +2 corresponding to the usual oxidation state of calcium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(83)80184-0
|
|
|
“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
|
|
“On the precision of oxygen determinations in steel by 14-MeVv neutron activation”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 52, 275 (1970). http://doi.org/10.1016/S0003-2670(01)80957-0
Abstract: The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)80957-0
|
|
|
“Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters”. Smits J, Van Grieken R, Analytica chimica acta 88, 97 (1977). http://doi.org/10.1016/S0003-2670(01)96053-2
Abstract: Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)96053-2
|
|
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
|
|
“Present and future applications of beam techniques in environmental microanalysis”. Jambers W, Van Grieken R, Trends in analytical chemistry 15, 114 (1996). http://doi.org/10.1016/0165-9936(95)00098-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0165-9936(95)00098-4
|
|
|
“Quantitative characterization of individual aerosol particles by thin-window electron probe microanalysis combined with iterative simulation”. Szalóki I, Osán J, Ro C-U, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 55, 1017 (2000). http://doi.org/10.1016/S0584-8547(00)00174-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00174-9
|
|
|
“Radio-isotope neutron activation analysis for vanadium, manganese and tungsten in alloy steels”. Lins Galdino SM, Costa Dantas C, Van Grieken R, Analytica chimica acta 196, 337 (1987). http://doi.org/10.1016/S0003-2670(00)83107-4
Abstract: An instrumental neutron activation method for V, Mn and W in alloy steels with a 241 Am/Be isotopic neutron source is described. The samples were irradiated to induce the nuclear reactions 51V(n, γ) 52V, 55Mn(n, γ)56Mn, and 186W(n, γ)187W. The activities were measured with a NaI(TI) detector. Interferences on the measured photopeaks were shown to be negligible by measuring the half-lives of 62V, 56Mn and 187W.These thre elementes were determined in the range 1.512.9% in special steels; manganese in the range 0.51.6% was measured in cast irons. Calibration was done by comparison with results from wet chemistry and x-ray fluorescence spectrometry. The processing times for the vanadium, manganese and tungsten determinations were 11 min, 3 h and 26.3 h, respectively, but these were reduced greatly by intoruding a scheme wherein six samples were simultaneously irradiated and the 56Mn and 187W nuclides were measured sequentially for a series of 66 samples. The average processing time was reduced to 45 min for tungsten with a precision of 4.0% and accuracy of 3.4% and 22.8 min for manganese with a precision of 3.8% and accuracy of 3.1%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)83107-4
|
|
|
“Recombination reactions and geometry effects in laser microprobe mass analysis studied with 12C/13C bilayers”. Bruynseels F, Van Grieken R, International journal of mass spectrometry and ion processes 74, 161 (1986). http://doi.org/10.1016/0168-1176(86)85003-0
Abstract: Bilayers of carbon, consisting of a layer of natural carbon and a second layer highly enriched in 13C, were investigated with the LAMMA 500-® instrument. When such a bilayer is perforated by the laser beam, comparable amounts of 12C and 13C are evaporated and partly ionized so that geometry effects and recombination reactions during laser-induced ionization can straightforwardly be studied.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0168-1176(86)85003-0
|
|
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
|
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
|
|
“Selenium in environmental waters : determination, speciation and concentration levels”. Robberecht H, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 29, 823 (1982). http://doi.org/10.1016/0039-9140(82)80252-X
Abstract: This article reviews the different methods used for the determination of selenium species in all types of environmental waters. Basic difficulties are discussed and the efficiency of the methods is explained in view of the sub-μg/1. concentration levels. Special attention is paid to preconcentration steps. Published data on speciation and concentration levels in various water samples are critically reviewed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80252-X
|
|
|
“Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis”. Vandecasteele C, Van Grieken R, Hoste J, Analytica chimica acta 72, 31 (1974). http://doi.org/10.1016/S0003-2670(01)82945-7
Abstract: Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)82945-7
|
|
|
“Single particle analysis of suspended matter in the Makasar Strait and Flores Sea with particular reference to tin-bearing particles”. Dekov VM, van Put A, Eisma D, Van Grieken R, Journal of sea research 41, 35 (1999). http://doi.org/10.1016/S1385-1101(98)00035-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1385-1101(98)00035-5
|
|
|
“Single particle and inorganic characterization of rainwater collected above the North Sea”. Jambers W, Dekov V, Van Grieken R, The science of the total environment 256, 133 (2000). http://doi.org/10.1016/S0048-9697(00)00477-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0048-9697(00)00477-0
|
|
|
“Single particle characterisation of inorganic and organic North Sea suspension”. Jambers W, Dekov V, Van Grieken R, Marine chemistry 67, 17 (1999). http://doi.org/10.1016/S0304-4203(99)00046-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(99)00046-8
|
|
|
“Soil analysis by thin-film energy-dispersive X-ray fluorescence”. Van Grieken R, Van 't dack L, Costa Dantas C, Da Silveira Dantas H, Analytica chimica acta 108, 93 (1979). http://doi.org/10.1016/S0003-2670(01)93044-2
Abstract: Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93044-2
|
|
|
“Spark-source mass-spectrometric sensitivity factors for elements in a graphite matrix”. Vanderborght B, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 26, 461 (1979). http://doi.org/10.1016/0039-9140(79)80111-3
Abstract: Relative sensitivity factors for determination of 41 elements by spark-source mass-spectrometry have been measured. The samples were pressed into graphite electrodes and ionized with a radiofrequency spark. The mass spectra were recorded on a photoplate and the resulting data processed by a computer. Indium was used as standard and the relative sensitivity factors for both singly- and doubly-charged ions were determined with reference to the singly-charged indium ion, with an overall error of 30%. The mean analysis precision was 16%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(79)80111-3
|
|
|
“Study of inorganic ammonium compounds in individual marine aerosol particles by laser microprobe mass spectrometry”. Otten P, Bruynseels F, Van Grieken R, Analytica chimica acta 195, 117 (1987). http://doi.org/10.1016/S0003-2670(00)85654-8
Abstract: Ammonia is important in the atmosphere because it neutralizes acidic species. The relative importance of different inorganic ammonium compounds (chloride, nitrate and sulfate) in marine air chemistry was studied by single-particle characterization with the laser microprobe mass analyser. Standard aerosols were generated as a reference for compound identification, based on the fingerprint spectra obtained, and calculation of the relative sensitivity achieved for different ions in a marine aerosol matrix. The relative sensitivity for ammonium was low. Aerosol samples were collected in the Southern Bight of the North Sea under different meteorological conditions and examined for their ammonium compounds. Samples collected during an inversion period with continental influences showed a much higher content in all particles than samples collected under different meteorological conditions, where ammonium was mostly detected in the submicrometer particle-size range.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85654-8
|
|
|
“A study of the weathering of an historic building”. Leysen L, Roekens E, Komy Z, Van Grieken R, Analytica chimica acta 195, 247 (1987). http://doi.org/10.1016/S0003-2670(00)85666-4
Abstract: Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85666-4
|
|
|
“Studying aerosol samples by non-linear mapping of electron probe microanalysis data”. Treiger B, van Malderen H, Bondarenko I, van Espen P, Van Grieken R, Analytica chimica acta 284, 119 (1993). http://doi.org/10.1016/0003-2670(93)80014-C
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0003-2670(93)80014-C
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“Weathering of dolomitic sandstone under ambient conditions”. Sweevers H, Delalieux F, Van Grieken R, Atmospheric environment : an international journal 32, 733 (1998). http://doi.org/10.1016/S1352-2310(97)00341-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(97)00341-5
|
|
|
“Analyses of petrified wood by electron, X-ray and optical microprobes”. Kuczumov A, Vekemans B, Schalm O, Dorriné, W, Chevallier P, Dillmann P, Ro C-U, Janssens K, Van Grieken R, Journal of analytical atomic spectroscopy 14, 435 (1999). http://doi.org/10.1039/A806748A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A806748A
|
|
|
“Analysis of speleothems by electron and X-ray microprobes”. Kuczumow A, Vekemans B, Schalm O, Gysels K, Ro C-U, Van Grieken R, Journal of analytical atomic spectrometry 16, 90 (2001). http://doi.org/10.1039/B007725I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B007725I
|
|
|
“Analysis of X-ray spectra excited by X rays, electrons, and protons in monazite”. Annegarn HJ, Madiba CCP, Sellschop JPF, Genz H, Hoffmann DHH, Low W, Richter A, Van Grieken RE, Physical review : C : nuclear physics 16, 379 (1977). http://doi.org/10.1103/PHYSREVC.16.379
Abstract: Mineral monazite from Malaysia has been investigated by energy dispersive x-ray analysis employing three different methods: x-ray, relativistic electron and proton induced excitation. An upper limit of 15 ppm has been placed on the possible concentration of the superheavy element with Z=126.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1103/PHYSREVC.16.379
|
|
|
“Assessing the molecular weight of a conducting polymer by grazing emission XRF”. Blockhuys F, Claes M, Van Grieken R, Geise HJ, Analytical chemistry 72, 3366 (2000). http://doi.org/10.1021/AC990877K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990877K
|
|