“Micro-heterogeneity study of trace elements in BCR CRM 680 by means of synchrotron micro-XRF”. Kempenaers L, de Koster C, van Borm W, Janssens K, Fresenius' journal of analytical chemistry 369, 733 (2001). http://doi.org/10.1007/S002160000679
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1007/S002160000679
|
Kempenaers L, Vincze L, Vekemans B, Janssens K, Adams F, Somogyi A, Drakopoulos M, Simionovici AS (2004) Micro-heterogeneity study of trace elements in reference materials. 132 p
Keywords: MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Micro-heterogeneity study of trace elements in USGS, MPI-DING and glass reference materials by means of synchrotron micro-XRF”. Kempenaers L, Janssens K, Jochum KP, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Adams F, Journal of analytical atomic spectrometry 18, 350 (2003). http://doi.org/10.1039/B212196D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 38
DOI: 10.1039/B212196D
|
“Micro-Raman analysis for the identification of pigments from 19th and 20th century paintings”. Aibéo CL, Goffin S, Schalm O, van der Snickt G, Laquière N, Eyskens P, Janssens K, Journal of Raman spectroscopy 39, 1091 (2008). http://doi.org/10.1002/JRS.1990
Abstract: In this article, results using confocal µ-Raman to analyse the cross-section of paint samples are presented. Results obtained with light microscopy, scanning electron microscopy (SEM) combined with an energy dispersive X-ray analysis (EDX) and micro-X-ray fluorescence (µ-XRF) are mentioned and compared to the ones obtained with confocal (MRS). In some cases, pigment identification was possible only by combining analytical results from different techniques. The samples were drawn from five paintings belonging to the Academy of Fine Arts of Antwerp, which are part of a collection of 34 paintings made by students from the Academy between 1819 and 1920. Since, on the one hand, the painting techniques and materials, especially pigments, used in this period are still not completely known, and on the other hand, this collection constitutes a very important and reliable resource of information, these paintings were chosen for a systematic investigation. They represent the evolution of painting in Belgium over approximately a century.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.969
Times cited: 28
DOI: 10.1002/JRS.1990
|
“Micro-XANES determination of ferric iron and its application in thermobarometry”. Schmid R, Wilke M, Ober R, Dong S, Janssens K, Falkenberg G, Franz L, Gaab A, Lithos 70, 381 (2003). http://doi.org/10.1016/S0024-4937(03)00107-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0024-4937(03)00107-5
|
“A micro XRF spectrometer based on rotating anode generator and capillary optics”. Janssens K, Vekemans B, Vincze L, Adams F, Rindby A, Spectrochimica acta: part B : atomic spectroscopy 51, 1661 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microanalysis (micro-XRF, micro-XANES, and micro-XRD) of a tertiary sediment using microfocused synchrotron radiation”. Denecke MA, Somogyi A, Janssens K, Simon R, Dardenne K, Noseck U, Microscopy and microanalysis 13, 165 (2007). http://doi.org/10.1017/S1431927607070316
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.891
Times cited: 31
DOI: 10.1017/S1431927607070316
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
“Microscopic single particle characterization of zeolites synthesized in a soil polluted by copper or cadmium and treated with coal fly ash”. Terzano R, Spagnuolo M, Medici L, Dorriné, W, Janssens K, Ruggiero P, Applied clay science 35, 128 (2007). http://doi.org/10.1016/J.CLAY.2006.07.005
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.101
Times cited: 17
DOI: 10.1016/J.CLAY.2006.07.005
|
“Microscopic synchroton radiation induced X-ray fluorescence analysis”. Janssens K, Vincze L, Aerts A, Vekemans B, Adams F, Jones K, Knöchel A, Mikrochimica acta: supplementum , 87 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Janssens KHA, Adams FCV, Rindby A (2000) Microscopic X-ray fluorescence analysis. 419 p
Keywords: MA1 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microscopic X-ray fluorescence analysis”. Janssens K, Vincze L, Rubio J, Bernasconi G, Adams F, Journal of analytical atomic spectrometry 9, 151 (1994). http://doi.org/10.1039/JA9940900151
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/JA9940900151
|
“Microscopic X-ray fluorescence analysis at second and third generation synchrotron sources”. Janssens K, Adams F, Debye Institute synchrotron chronicle , 9 (1997)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microscopical X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources”. Adams F, Janssens K, Snigirev A, Journal of analytical atomic spectrometry 13, 319 (1998). http://doi.org/10.1039/A707100K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A707100K
|
“Modeling of photon scattering at high X-ray energies : experiment versus simulation”. Vincze L, Vekemans B, Janssens K, Adams F, Journal of analytical atomic spectrometry
T2 –, 15th International Congress on X-Ray Optics and Microanalysis (ICXOM), AUG 24-27, 1998, ANTWERP, BELGIUM 14, 529 (1999). http://doi.org/10.1039/A808040B
Abstract: The use of a detailed Monte Carlo simulation code for X-ray fluorescence spectrometers is demonstrated for calculating the outcome of X-ray scattering experiments in the incident energy range 40-80 keV. The code was validated by comparisons of experimental and simulated spectral distributions in the case of thick, homogeneous samples in which multiple photon scattering occurs with high probability. The experimental spectral distributions were collected at beamline BW5 of HASYLAB, Germany, where a highly energetic, monochromatic synchrotron beam is available. With respect to heterogeneous samples, the code was employed to evaluate the use of Rayleigh and Compton scatter signals for obtaining three dimensional information on the sample dark matrix composition.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
DOI: 10.1039/A808040B
|
“A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence”. Kempenaers L, Janssens K, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Simionovici AS, Adams F, Analytical chemistry 74, 5017 (2002). http://doi.org/10.1021/AC025662G
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 21
DOI: 10.1021/AC025662G
|
“Monte Carlo simulation for X-ray fluorescence spectroscopy”. Vincze L, Janssens K, Vekemans B, Adams F page 435 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
“Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments”. Vincze L, Janssens K, Vekemans B, Adams F page 328 (1999).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.363736
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
“Multianalytical study of patina formed on archaeological metal objects from Bliesbruck-Reinheim”. Wadsak M, Constantinides I, Vittiglio G, Adriaens A, Janssens K, Schreiner M, Adams FC, Brunella P, Wuttmann M, Microchimica acta 133, 159 (2000). http://doi.org/10.1007/S006040070086
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.58
DOI: 10.1007/S006040070086
|
“In vitro validation of a mobile Raman-XRF micro-analytical instrument's capabilities on the diagnosis of Byzantine icons”. Andrikopoulos KS, Daniilia S, Roussel B, Janssens K, Journal of Raman spectroscopy 37, 1026 (2006). http://doi.org/10.1002/JRS.1612
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.969
Times cited: 53
DOI: 10.1002/JRS.1612
|
“Near-field diffraction of fs and sub-fs pulses: super resolution of NSOM in space and time”. Kukhlevsky SV, Mechler M, Csapo L, Janssens K, Physics letters : A 319, 439 (2003). http://doi.org/10.1016/J.PHYSLETA.2003.10.054
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.772
Times cited: 10
DOI: 10.1016/J.PHYSLETA.2003.10.054
|
“The non-destructive determination of REE in fossilized bone using synchrotron radiation induced K-line X-ray microfluorescence analysis”. Janssens K, Vincze L, Vekemans B, Williams CT, Radtke M, Haller M, Knöchel A, Fresenius' journal of analytical chemistry 363, 413 (1999). http://doi.org/10.1007/S002160051212
Abstract: The sensitivity and applicability of the synchrotron radiation induced X-ray microfluorescence (mu-SRXRF) spectrometer at the Hamburg synchrotron laboratory Hasylab for the determination of the distribution of trace concentrations of rare-earth elements (REE) in fossilized bone are discussed and critically compared to those of other trace analytical methods such as instrumental neutron activation analysis (INAA) and LAMP-ICPMS (laser ablation microprobe inductively-coupled plasma mass spectrometry). Measurements were carried out on two bone samples from contrasting terrestrial depositional environments at Olduvai Gorge (Tanzania). Results indicate that the microdistribution of the REE in these biological materials is not homogeneous and that the relative abundance of these elements can provide information on the palaeoenvironment during the fossilization process. The heterogeneous distribution of the REE can be determined in a quantitative and completely non-destructive manner provided the concentrations of individual REE are above 10 mu g/g.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S002160051212
|
“Non-destructive micoranalysis of cultural heritage materials”. Janssens K, Van Grieken R page 800 p. (2004).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Novel quantitative procedures for in-situ X-ray fluorescence analysis”. Van Grieken R, Janssens K, van Espen P, Injuk J, Padilla R, Vittiglio G, Potgieter JH page 45 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Novel quantitative procedures for in-situ X-ray fluorescence analysis”. Injuk J, Janssens K, van Espen P, Van Grieken R, (2001)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“On the distinction between 16th and 17th century Venetian glass and façon-de-Venise glass”. de Raedt I, Janssens K, Veeckman J page 95 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Optics for X-ray microfluorescence to be used at the European synchrotron radiation facility”. Vincze L, Janssens K, Adams F, Advances in X-ray analysis 37, 553 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|