Home | << 1 2 3 4 5 6 >> |
![]() |
Records | |||||
---|---|---|---|---|---|
Author | Lobato, I.; De Backer, A.; Van Aert, S. | ||||
Title | Real-time simulations of ADF STEM probe position-integrated scattering cross-sections for single element fcc crystals in zone axis orientation using a densely connected neural network | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 251 | Issue | Pages | 113769 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantification of annular dark field (ADF) scanning transmission electron microscopy (STEM) images in terms of composition or thickness often relies on probe-position integrated scattering cross sections (PPISCS). In order to compare experimental PPISCS with theoretically predicted ones, expensive simulations are needed for a given specimen, zone axis orientation, and a variety of microscope settings. The computation time of such simulations can be in the order of hours using a single GPU card. ADF STEM simulations can be efficiently parallelized using multiple GPUs, as the calculation of each pixel is independent of other pixels. However, most research groups do not have the necessary hardware, and, in the best-case scenario, the simulation time will only be reduced proportionally to the number of GPUs used. In this manuscript, we use a learning approach and present a densely connected neural network that is able to perform real-time ADF STEM PPISCS predictions as a function of atomic column thickness for most common face-centered cubic (fcc) crystals (i.e., Al, Cu, Pd, Ag, Pt, Au and Pb) along [100] and [111] zone axis orientations, root-mean-square displacements, and microscope parameters. The proposed architecture is parameter efficient and yields accurate predictions for the PPISCS values for a wide range of input parameters that are commonly used for aberration-corrected transmission electron microscopes. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 001011617200001 | Publication Date | 2023-06-01 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes ![]() |
This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G034621N and G0A7723N) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF), Belgium. | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:197275 | Serial | 8812 | ||
Permanent link to this record | |||||
Author | Şentürk, DG.; Yu, CP.; De Backer, A.; Van Aert, S. | ||||
Title | Atom counting from a combination of two ADF STEM images | Type | A1 Journal article | ||
Year | 2024 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 255 | Issue | Pages | 113859 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | To understand the structure–property relationship of nanostructures, reliably quantifying parameters, such as the number of atoms along the projection direction, is important. Advanced statistical methodologies have made it possible to count the number of atoms for monotype crystalline nanoparticles from a single ADF STEM image. Recent developments enable one to simultaneously acquire multiple ADF STEM images. Here, we present an extended statistics-based method for atom counting from a combination of multiple statistically independent ADF STEM images reconstructed from non-overlapping annular detector collection regions which improves the accuracy and allows one to retrieve precise atom-counts, especially for images acquired with low electron doses and multiple element structures. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 001089064200001 | Publication Date | 2023-09-23 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes ![]() |
This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G034621N, G0A7723N, and EOS 40007495) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF). | Approved | Most recent IF: 2.2; 2024 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:201008 | Serial | 8964 | ||
Permanent link to this record | |||||
Author | De Backer, A.; Bals, S.; Van Aert, S. | ||||
Title | A decade of atom-counting in STEM: From the first results toward reliable 3D atomic models from a single projection | Type | A1 Journal article | ||
Year | 2023 | Publication | Ultramicroscopy | Abbreviated Journal | |
Volume | Issue | Pages | 113702 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Quantitative structure determination is needed in order to study and understand nanomaterials at the atomic scale. Materials characterisation resulting in precise structural information is a crucial point to understand the structure–property relation of materials. Counting the number of atoms and retrieving the 3D atomic structure of nanoparticles plays an important role here. In this paper, an overview will be given of the atom-counting methodology and its applications over the past decade. The procedure to count the number of atoms will be discussed in detail and it will be shown how the performance of the method can be further improved. Furthermore, advances toward mixed element nanostructures, 3D atomic modelling based on the atom-counting results, and quantifying the nanoparticle dynamics will be highlighted. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000953765800001 | Publication Date | 2023-02-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | 3 | Open Access | OpenAccess |
Notes ![]() |
This work was supported by the European Research Council (Grant 770887 PICOMETRICS to S. Van Aert, Grant 815128 REALNANO to S. Bals, and Grant 823717 ESTEEM3). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0267.18N, G.0502.18N, G.0346.21N, and EOS 30489208) and a postdoctoral grant to A. De Backer. S. Van Aert acknowledges funding from the University of Antwerp Research fund (BOF) . The authors also thank the colleagues who have contributed to this work over the years, including T. Altantzis, E. Arslan Irmak, K.J. Batenburg, E. Bladt, A. De wael, R. Erni, C. Faes, B. Goris, L. Jones, L.M. Liz-Marzán, I. Lobato, G.T. Martinez, P.D. Nellist, M.D. Rosell, A. Rosenauer, K.H.W. van den Bos, A. Varambhia, and Z. Zhang.; esteem3reported; esteem3JRA | Approved | Most recent IF: 2.2; 2023 IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:195896 | Serial | 7236 | ||
Permanent link to this record | |||||
Author | Schattschneider, P.; Stöger-Pollach, M.; Löffler, S.; Steiger-Thirsfeld, A.; Hell, J.; Verbeeck, J. | ||||
Title | Sub-nanometer free electrons with topological charge | Type | A1 Journal article | ||
Year | 2012 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 115 | Issue | Pages | 21-25 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The holographic mask technique is used to create freely moving electrons with quantized angular momentum. With electron optical elements they can be focused to vortices with diameters below the nanometer range. The understanding of these vortex beams is important for many applications. Here, we produce electron vortex beams and compare them to a theory of electrons with topological charge. The experimental results show excellent agreement with simulations. As an immediate application, fundamental experimental parameters like spherical aberration and partial coherence are determined. (C) 2012 Elsevier B.V. All rights reserved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000302962400004 | Publication Date | 2012-01-30 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 24 | Open Access | |
Notes ![]() |
vortex ECASJO_; | Approved | Most recent IF: 2.843; 2012 IF: 2.470 | ||
Call Number | UA @ lucian @ c:irua:98279 | Serial | 3344 | ||
Permanent link to this record | |||||
Author | Vanrompay, H.; Skorikov, A.; Bladt, E.; Béché, A.; Freitag, B.; Verbeeck, J.; Bals, S. | ||||
Title | Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113191 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600003 | Publication Date | 2020-12-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | OpenAccess |
Notes ![]() |
We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CIC biomaGUNE, Spain for providing the Au@Ag nanoparticles, Prof. Sara. E. Skrabalak and co-workers of Indiana University, United States for the provision of the Au octopods and Prof. Teri W. Odom of Northwestern University, United States for the provision of the Au nanostars. H.V. acknowledges financial support by the Research Foundation Flanders (FWO grant 1S32617N). S.B acknowledges financial support by the Research Foundation Flanders (FWO grant G.0381.16N). This project received funding as well from the European Union’s Horizon 2020 research and innovation program under grant agreement No 731019 (EUSMI) and No 815128 (REALNANO). The authors acknowledge the entire EMAT technical staff for their support.; sygma | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174551 | Serial | 6660 | ||
Permanent link to this record | |||||
Author | Robert, Hl.; Lobato, I.; Lyu, Fj.; Chen, Q.; Van Aert, S.; Van Dyck, D.; Müller-Caspary, K. | ||||
Title | Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning transmission electron microscopy at atomic resolution | Type | A1 Journal article | ||
Year | 2022 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 233 | Issue | Pages | 113425 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | We report a study of scattering dynamics in crystals employing momentum-resolved scanning transmission electron microscopy under varying illumination conditions. As we perform successive changes of the probe focus, multiple real-space signals are obtained in dependence of the shape of the incident electron wave. With support from extensive simulations, each signal is shown to be characterised by an optimum focus for which the contrast is maximum and which differs among different signals. For instance, a systematic focus mismatch is found between images formed by high-angle scattering, being sensitive to thickness and chemical composition, and the first moment in diffraction space, being sensitive to electric fields. It follows that a single recording at one specific probe focus is usually insufficient to characterise materials comprehensively. Most importantly, we demonstrate in experiment and simulation that the second moment ( |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000734396800009 | Publication Date | 2021-11-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.2 | Times cited | Open Access | OpenAccess | |
Notes ![]() |
We thank Dr. Florian Winkler for valuable discussions and experimental work at the early stages of this study. This work was supported by the Initiative and Network Fund of the Helmholtz Association (Germany) under contracts VH-NG-1317 and ZT-I-0025. This project furthermore received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (grant agreement No. 770887). | Approved | Most recent IF: 2.2 | ||
Call Number | EMAT @ emat @c:irua:184833 | Serial | 6898 | ||
Permanent link to this record |