|
“Computational comparisons between the conventional multislice method and the third-order multislice method for calculating high-energy electron diffraction and imaging”. Chen JH, van Dyck D, op de Beeck M, van Landuyt J, Ultramicroscopy 69, 219 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 11
|
|
|
“Determination of the mean inner potential in III-V semiconductors, Si and Ge by density functional theory and electron holography”. Kruse P, Schowalter M, Lamoen D, Rosenauer A, Gerthsen D, Ultramicroscopy 106, 105 (2006). http://doi.org/10.1016/j.ultramic.2005.06.057
Keywords: A1 Journal article; Electron Microscopy for Materials Science (EMAT);
Impact Factor: 2.843
Times cited: 50
DOI: 10.1016/j.ultramic.2005.06.057
|
|
|
“Does a monochromator improve the precision in quantitative HRTEM?”.den Dekker AJ, Van Aert S, van Dyck D, van den Bos A, Geuens P, Ultramicroscopy 89, 275 (2001). http://doi.org/10.1016/S0304-3991(01)00089-4
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 22
DOI: 10.1016/S0304-3991(01)00089-4
|
|
|
“Dynamical effects in strain measurements by dark-field electron holography”. Javon E, Lubk, Cours R, Reboh S, Cherkashin N, Houdellier F, Gatel C, Hytch MJ, Ultramicroscopy 147, 70 (2014). http://doi.org/10.1016/j.ultramic.2014.06.005
Abstract: Here, we study the effect of dynamic scattering on the projected geometric phase and strain maps reconstructed using dark-field electron holography (DFEH) for non-uniformly strained crystals. The investigated structure consists of a {SiGe/Si} superlattice grown on a (001)-Si substrate. The three dimensional strain held within the thin TEM lamella is modelled by the finite element method. The observed projected strain is simulated in two ways by multiplying the strain at each depth in the crystal by a weighting function determined from a recently developed analytical two-beam dynamical theory, and by simply taking the average value. We demonstrate that the experimental results need to be understood in terms of the dynamical theory and good agreement is found between the experimental and simulated results. Discrepancies do remain for certain cases and are likely to be from an imprecision in the actual two-beam diffraction conditions, notably the deviation parameter, and points to limitations in the 2-beam approximation. Finally, a route towards a 3D reconstruction of strain fields is proposed. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 10
DOI: 10.1016/j.ultramic.2014.06.005
|
|
|
“Dynamical electron diffraction in substitutionally disordered column structures”. De Meulenaere P, van Dyck D, Van Tendeloo G, van Landuyt J, Ultramicroscopy 60, 171 (1995). http://doi.org/10.1016/0304-3991(95)00040-8
Abstract: For column structures, such as fee-based alloys viewed along the cube direction, the concept of electron channelling through the atom columns is more and more used to interpret the corresponding HREM images. In the case of(partially) disordered columns, the projected potential approach which is used in the channelling description must be questioned since the arrangement of the atoms along the beam direction might affect the exit wave of the electrons. In this paper, we critically inspect this top-bottom effect using multi-slice calculations. A modified channelling theory is introduced which turns out to be very appropriate for the interpretation of these results. For substitutionally disordered column structures, it is also discussed how to link the chemical composition of the material to statistical data of the HREM image. This results in a convenient tool to discern images taken at different thicknesses and focus values.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(95)00040-8
|
|
|
“Electron channelling based crystallography”. Van Aert S, Geuens P, van Dyck D, Kisielowski C, Jinschek JR, Ultramicroscopy 107, 551 (2007). http://doi.org/10.1016/j.ultramic.2006.04.031
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 32
DOI: 10.1016/j.ultramic.2006.04.031
|
|
|
“Electron diffraction effects of conical, helically wound, graphite whiskers”. Luyten W, Krekels T, Amelinckx S, Van Tendeloo G, van Dyck D, van Landuyt J, Ultramicroscopy 49, 123 (1993). http://doi.org/10.1016/0304-3991(93)90219-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 14
DOI: 10.1016/0304-3991(93)90219-N
|
|
|
“An emission-potential multislice approximation to simulate thermal diffuse scattering in high-resolution transmission electron microscopy”. Rosenauer A, Schowalter M, Titantah JT, Lamoen D, Ultramicroscopy 108, 1504 (2008). http://doi.org/10.1016/j.ultramic.2008.04.002
Abstract: Thermal diffuse scattered electrons significantly contribute to high-resolution transmission electron microscopy images. Their intensity adds to the background and is peaked at positions of atomic columns. In this paper we suggest an approximation to simulate intensity of thermal diffuse scattered electrons in plane-wave illumination transmission electron microscopy using an emission-potential multislice algorithm which is computationally less intensive than the frozen lattice approximation or the mutual intensity approach. Intensity patterns are computed for Au and InSb for different crystal orientations. These results are compared with intensities from the frozen lattice approximation based on uncorrelated vibration of atoms as well as with the frozen phonon approximation for Au. The frozen phonon method uses a detailed phonon model based on force constants we computed by a density functional theory approach. The comparison shows that our suggested emission-potential method is in close agreement with both the frozen lattice and the frozen phonon approximations.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 25
DOI: 10.1016/j.ultramic.2008.04.002
|
|
|
“Improved multislice calculations for including higher-order Laue zones effects”. Lobato I, van Dyck D, Ultramicroscopy 119, 63 (2012). http://doi.org/10.1016/j.ultramic.2012.01.003
Abstract: A new method for including higher-order Laue zones (HOLZs) effects in an efficient way in electron scattering simulations has been developed and tested by detail calculations. The calculated results by the conventional multislice (CMS) method and the improved conventional multislice (ICMS) method using a large dynamical aperture to avoid numerical errors are compared with accurate results. We have found that the zero-order Laue zones (ZOLZs) reflection cannot be properly described only using the projected potential in the whole unit cell; in general, we need to subslice the electrostatic potential inside the unit cell. It is shown that the ICMS method has higher accuracy than the CMS method for the calculation of the ZOLZ, HOLZ and Pseudo-HOLZ reflections. Hence, ICMS method allows to use a larger slice thickness than the CMS method and reduces the calculation time. (C) 2012 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 6
DOI: 10.1016/j.ultramic.2012.01.003
|
|
|
“In situ HREM study of electron irradiation effects in AgCl microcrystals”. Goessens C, Schryvers D, van Landuyt J, de Keyzer R, Ultramicroscopy 40, 151 (1992). http://doi.org/10.1016/0304-3991(92)90056-P
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 10
DOI: 10.1016/0304-3991(92)90056-P
|
|
|
“Inelastic scattering of high-energy electrons in a crystal in thermal equilibrium with the environment: 1: theoretical framework”. Fanidis C, van Dyck D, van Landuyt J, Ultramicroscopy 41, 55 (1992). http://doi.org/10.1016/0304-3991(92)90094-Z
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 17
DOI: 10.1016/0304-3991(92)90094-Z
|
|
|
“Inelastic scattering of high-energy electrons in a crystal in thermal equilibrium with the environment: part 2: solution of the equations and applications to concrete cases”. Fanidis C, van Dyck D, van Landuyt J, Ultramicroscopy 48, 133 (1993)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 6
|
|
|
“Introduction to a special issue in honour of W. Owen Saxton, David J. Smith and Dirk Van Dyck on the occasion of their 65th birthdays”. Dunin-Borkowski RE, Lichte H, Tillmann K, Van Aert S, Van Tendeloo G, Ultramicroscopy 134, 1 (2013). http://doi.org/10.1016/j.ultramic.2013.07.013
Keywords: Editorial; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 1
DOI: 10.1016/j.ultramic.2013.07.013
|
|
|
“Is atomic resolution transmission electron microscopy able to resolve and refine amorphous structures?”.van Dyck D, Van Aert S, den Dekker AJ, van den Bos A, Ultramicroscopy 98, 27 (2003). http://doi.org/10.1016/S0304-3991(03)00023-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 26
DOI: 10.1016/S0304-3991(03)00023-8
|
|
|
“Maximum likelihood estimation of structure parameters from high resolution electron microscopy images: part 1: a theoretical framework”. den Dekker AJ, Van Aert S, van den Bos A, van Dyck D, Ultramicroscopy 104, 83 (2005). http://doi.org/10.1016/j.ultramic.2005.03.001
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 70
DOI: 10.1016/j.ultramic.2005.03.001
|
|
|
“Maximum likelihood estimation of structure parameters from high resolution electron microscopy images : part 2 : a practical example”. Van Aert S, den Dekker AJ, van den Bos A, van Dyck D, Chen JH, Ultramicroscopy 104, 107 (2005). http://doi.org/10.1016/j.ultramic.2005.03.002
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 37
DOI: 10.1016/j.ultramic.2005.03.002
|
|
|
“Measurement of specimen thickness by phase change determination in TEM”. Croitoru MD, van Dyck D, Liu YZ, Zhang Z, Ultramicroscopy 108, 1616 (2008). http://doi.org/10.1016/j.ultramic.2008.06.002
Abstract: A non-destructive method for measuring the thickness of thin amorphous films composed of light elements has been developed. The method employs the statistics of the phase of the electron exit wave function. The accuracy of this method has been checked numerically by the multislice method and compared with that based on the mean inner potential.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 2
DOI: 10.1016/j.ultramic.2008.06.002
|
|
|
“Measuring the absolute position of EELS ionisation edges in a TEM”. Potapov PL, Schryvers D, Ultramicroscopy 99, 73 (2004). http://doi.org/10.1016/S0304-3991(03)00185-2
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 29
DOI: 10.1016/S0304-3991(03)00185-2
|
|
|
“A model based atomic resolution tomographic algorithm”. van den Broek W, Van Aert S, van Dyck D, Ultramicroscopy 109, 1485 (2009). http://doi.org/10.1016/j.ultramic.2009.08.003
Abstract: Tomography with high angular annular dark field scanning transmission electron microscopy at atomic resolution can be greatly improved if one is able to take advantage of prior knowledge. In this paper we present a reconstruction technique that explicitly takes into account the microscope parameters and the atomic nature of the projected object. This results in a more accurate estimate of the atomic positions and in a good resistance to noise. The reconstruction is a maximum likelihood estimator of the object. Moreover, the limits to the precision have been explored, allowing for a prediction of the amount of expected noise in the reconstruction for a certain experimental setup. We believe that the proposed reconstruction technique can be generalized to other tomographic experiments.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 17
DOI: 10.1016/j.ultramic.2009.08.003
|
|
|
“On the interpretation of HREM images of partially ordered alloys”. De Meulenaere P, Van Tendeloo G, van Landuyt J, van Dyck D, Ultramicroscopy 60, 265 (1995). http://doi.org/10.1016/0304-3991(95)00065-9
Abstract: The ordering for 11/20 alloys has been studied by high-resolution electron microscopy (HREM). The distribution of the intensity maxima in the HREM image have been statistically examined, which provides a profound basis for the image interpretation. Processing of the HREM images allows ''dark-field'' images to be obtained, exhibiting a two-dimensional distribution of those columns which contain the most information in order to interpret the short-range order correlations. Pair correlations and higher cluster correlations between projected columns can be visualised, providing unique information about the ordering as retrieved from an experimental result without any other assumption. The method has been applied to Au4Cr and to Au4Mn to interpret the quenched short-range order state and the transition to long-range order.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.436
Times cited: 20
DOI: 10.1016/0304-3991(95)00065-9
|
|
|
“Optimal experimental design of STEM measurement of atom column positions”. Van Aert S, den Dekker AJ, van Dyck D, van den Bos A, Ultramicroscopy 90, 273 (2002). http://doi.org/10.1016/S0304-3991(01)00152-8
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 35
DOI: 10.1016/S0304-3991(01)00152-8
|
|
|
“The reciprocal space of carbon tubes: a detailed interpretation of the electron diffraction effects”. Zhang XB, Zhang XF, Amelinckx S, Van Tendeloo G, van Landuyt J, Ultramicroscopy 54, 237 (1994). http://doi.org/10.1016/0304-3991(94)90123-6
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 59
DOI: 10.1016/0304-3991(94)90123-6
|
|
|
“Selective imaging of sublattices in complex structures”. Amelinckx S, Milat O, Van Tendeloo G, Ultramicroscopy 51, 90 (1993). http://doi.org/10.1016/0304-3991(93)90138-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 8
DOI: 10.1016/0304-3991(93)90138-N
|
|
|
“Selective imaging of the “substructures&rdquo, in incommensurately modulated intergrowth crystal structures”. Milat O, Van Tendeloo G, Amelinckx S, Ultramicroscopy 41, 65 (1992). http://doi.org/10.1016/0304-3991(92)90095-2
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 5
DOI: 10.1016/0304-3991(92)90095-2
|
|
|
“A simple preparation method for air-sensitive specimens for transmission electron microscopy demonstrated by Rb6C60”. Zhang XF, Zhang XB, Bernaerts D, Van Tendeloo G, Amelinckx S, van Landuyt J, Werner H, Ultramicroscopy 55, 25 (1994). http://doi.org/10.1016/0304-3991(94)90077-9
Abstract: In this paper a particularly simple but efficient method is presented by which samples of alkali-doped C-60 materials or other air-sensitive materials can be prepared and transferred into a transmission electron microscope for direct observations and investigations. Flexible, transparent glove bags are used which are filled to a slight overpressure with dry nitrogen. Under this protective atmosphere, the air-sensitive sample is mounted in the specimen holder and inserted in the vacuum of the electron microscope. Rb6C60 which is prepared and transferred into the microscope in this way has been investigated by transmission electron microscopy (TEM). The results confirm the bcc structure and especially the location of the rubidium atoms.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 2
DOI: 10.1016/0304-3991(94)90077-9
|
|
|
“Strain measurement at the nanoscale : comparison between convergent beam electron diffraction, nano-beam electron diffraction, high resolution imaging and dark field electron holography”. Béché, A, Rouviere JL, Barnes JP, Cooper D, Ultramicroscopy 131, 10 (2013). http://doi.org/10.1016/j.ultramic.2013.03.014
Abstract: Convergent beam electron diffraction (CBED), nano-beam electron diffraction (NBED or NBD), high resolution imaging (HRTEM and HRSTEM) and dark field electron holography (DFEH or HoloDark) are five TEM based techniques able to quantitatively measure strain at the nanometer scale. In order to demonstrate the advantages and disadvantages of each technique, two samples composed of epitaxial silicon-germanium layers embedded in a silicon matrix have been investigated. The five techniques are then compared in terms of strain precision and accuracy, spatial resolution, field of view, mapping abilities and ease of performance and analysis. (C) 2013 Elsevier By. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 73
DOI: 10.1016/j.ultramic.2013.03.014
|
|
|
“Structures and phase transitions in C60 and C70 fullerites”. Van Tendeloo G, Amelinckx S, Muto S, Verheijen MA, van Loosdrecht PHM, Meijer G, Ultramicroscopy 51, 168 (1993). http://doi.org/10.1016/0304-3991(93)90145-N
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
Times cited: 17
DOI: 10.1016/0304-3991(93)90145-N
|
|
|
“The evolution of HVEM application in antwerp”. van Landuyt J, Ultramicroscopy
T2 –, 2nd Osaka International Symp.on High-Voltage Electron Microscopy : New Directions and Future Aspects of High Voltage Electron Microscopy, November 8-10, 1990, Osaka University, Osaka, Japan 39, 287 (1991). http://doi.org/10.1016/0304-3991(91)90208-N
Abstract: The evolution of the use of the 1250 keV high-voltage electron microscope in Antwerp is sketched by illustrating a non-exhaustive set of examples in various fields. One of the main present fields of application gets some more attention, i.e. the defect studies as produced by processing steps in microelectronic devices: (i) strain-induced dislocations at the edges of various device isolation interlayers, (ii) morphologies resulting from high-energy ion implantation creating buried layers for silicon on insulator (SOI) and other implantation technologies.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.436
DOI: 10.1016/0304-3991(91)90208-N
|
|
|
“Throughput maximization of particle radius measurements by balancing size and current of the electron probe”. van den Broek W, Van Aert S, Goos P, van Dyck D, Ultramicroscopy 111, 940 (2011). http://doi.org/10.1016/j.ultramic.2010.11.025
Abstract: In thispaperweinvestigatewhichprobesizemaximizesthethroughputwhenmeasuringtheradiusof nanoparticlesinhighangleannulardarkfieldscanningtransmissionelectronmicroscopy(HAADFSTEM). The sizeandthecorrespondingcurrentoftheelectronprobedeterminetheprecisionoftheestimateofa particlesradius.Maximizingthroughputmeansthatamaximumnumberofparticlesshouldbeimaged withinagiventimeframe,sothataprespecifiedprecisionisattained.WeshowthatBayesianstatistical experimentaldesignisaveryusefulapproachtodeterminetheoptimalprobesizeusingacertainamount of priorknowledgeaboutthesample.Thedependenceoftheoptimalprobesizeonthedetectorgeometry and thediameter,variabilityandatomicnumberoftheparticlesisinvestigated.Anexpressionforthe optimalprobesizeintheabsenceofanykindofpriorknowledgeaboutthespecimenisderivedaswell.
Keywords: A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.843
Times cited: 7
DOI: 10.1016/j.ultramic.2010.11.025
|
|
|
“Dark field electron holography for strain measurement”. Béché, A, Rouvière JL, Barnes JP, Cooper D, Ultramicroscopy 111, 227 (2011). http://doi.org/10.1016/J.ULTRAMIC.2010.11.030
Abstract: Dark field electron holography is a new TEM-based technique for measuring strain with nanometer scale resolution. Here we present the procedure to align a transmission electron microscope and obtain dark field holograms as well as the theoretical background necessary to reconstruct strain maps from holograms. A series of experimental parameters such as biprism voltage, sample thickness, exposure time, tilt angle and choice of diffracted beam are then investigated on a silicon-germanium layer epitaxially embedded in a silicon matrix in order to obtain optimal dark field holograms over a large field of view with good spatial resolution and strain sensitivity.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.843
Times cited: 31
DOI: 10.1016/J.ULTRAMIC.2010.11.030
|
|