“Control and readout of current-induced magnetic flux quantization in a superconducting transformer”. Kerner C, Hackens B, Golubović, DS, Poli S, Faniel S, Magnus W, Schoenmaker W, Bayot V, Maes H, Superconductor science and technology 22, 025001 (2009). http://doi.org/10.1088/0953-2048/22/2/025001
Abstract: We demonstrate a simple and robust method for inducing and detecting changes of magnetic flux quantization in the absence of an externally applied magnetic field. In our device, an isolated ring is interconnected with two access loops via permalloy cores, forming a superconducting transformer. By applying and tuning a direct current at the first access loop, the number of flux quanta trapped in the isolated ring is modified without the aid of an external field. The flux state of the isolated ring is simply detected by recording the evolution of the critical current of the second access loop.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.878
Times cited: 2
DOI: 10.1088/0953-2048/22/2/025001
|
“Defects in high-dose oxygen implanted silicon : a TEM study”. Deveirman A, van Landuyt J, Vanhellemont J, Maes HE, Yallup K, Vacuum: the international journal and abstracting service for vacuum science and technology
T2 –, 1ST SIOMX WORKSHOP ( SEPARATION BY IMPLANTATION OF OXYGEN ) ( SWI-88 ), NOV 07-08, 1988, UNIV SURREY, GUILDFORD, ENGLAND 42, 367 (1991). http://doi.org/10.1016/0042-207X(91)90055-N
Abstract: Results are discussed of a transmission electron microscopy study of high-dose oxygen implanted silicon. In addition to the general high temperature (> 1200-degrees-C) annealing treatments also annealings at 'low' temperatures (1000-1100-degrees-C) were performed in order to slow down the precipitate and defect reactions. The observed dissolution of the oxide precipitates during prolonged high temperature annealing is explained by critical radius considerations. Threading dislocations are the remaining lattice defects in the silicon overlayer and cannot be removed by further annealing. Low temperature annealing results in the formation and subsequent unfaulting of extrinsic stacking fault loops below the buried oxide layer.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.858
Times cited: 4
DOI: 10.1016/0042-207X(91)90055-N
|
“Round-robin investigation of silicon-oxide on silicon reference materials for ellipsometry”. Vanhellemont J, Maes HE, Schaekers M, Armigliato A, Cerva H, Cullis A, de Sande J, Dinges H, Hallais J, Nayar V, Pickering C, Stehlé, JL, Van Landuyt J, Walker C, Werner H, Salieri P;, Applied surface science
T2 –, SYMP ON DIAGNOSTIC TECHNIQUES FOR SEMICONDUCTOR MATERIALS ANALYSIS AND, FABRICATION PROCESS CONTROL, AT THE 1992 SPRING CONF OF THE EUROPEAN, MATERIALS RESEARCH SOC, JUN 02-05, 1992, STRASBOURG, FRANCE 63, 45 (1993). http://doi.org/10.1016/0169-4332(93)90062-G
Abstract: The main results and conclusions are presented of a round robin study of silicon oxide on silicon reference samples for ellipsometry. The oxide films with nominal thicknesses of 10, 50 and 120 nm are grown by thermal oxidation. The oxide film thicknesses have been determined by single wavelength ellipsometry (SWE), by spectroscopic ellipsometry (SE) and by cross-sectional conventional and high-resolution transmission electron microscopy (TEM and HREM) in different laboratories. The main conclusions are that special precautions have to be taken in order to use TEM as a reliable thickness measurement technique; that single wavelength ellipsometry can be used with great accuracy and reproducibility for the 50 and 120 nm film thicknesses but that it shows some inherent problems for the 10 nm films; and that spectroscopic ellipsometry showed for all film thicknesses an accuracy and reproducibility which is clearly superior to that of SWE.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.711
Times cited: 13
DOI: 10.1016/0169-4332(93)90062-G
|