|
“Selenium in the Belgian soils and its uptake by rye-grass”. Robberecht H, vanden Berghe D, Deelstra H, Van Grieken R, The science of the total environment 25, 61 (1982). http://doi.org/10.1016/0048-9697(82)90042-0
Abstract: Data obtained by atomic absorption spectroscopy showed a selenium concentration of only 0.11 ppm as an average value for the most representative agricultural soils in Belgium. The selenium content in rye-grass grown on different soil types was between 0.05 and 0.11 ppm, and positively correlated with the soil selenium level. Addition of selenium in the form of selenite to the different soil types resulted in an increased selenium uptake by the plant. The ultimate concentration in the plant depended on the structural and chemical composition of the soil. Twelve other elements were determined in the soils by energy-dispersive X-ray fluorescence; none showed a strong correlation with the soil selenium content or with the selenium uptake by ryegrass.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(82)90042-0
|
|
|
“Serum bromine levels in psoriasis”. Shani J, Barak S, Ram M, Levi D, Pfeifer Y, Schlesinger T, Avrach WW, Robberecht H, Van Grieken R, Pharmacology 25, 297 (1982). http://doi.org/10.1159/000137756
Abstract: Serum bromine levels in psoriatic Danes increased 2- to 3-fold during a 4-week bathing course in the Dead Sea. This increase correlated well with the improvement in their clinical and psychic condition. Serum bromine levels in psoriatic Danes were somewhat lower than those in healthy subjects residing in Denmark, but the difference was not significant. Israelis working in the open air in the Dead Sea area (air bromine 20-fold higher than in Jerusalem) had higher bromine levels than psoriatic or healthy Israelis residing in Jerusalem or healthy Israelis working in air-conditioned rooms in the Dead Sea area (p < 0.05), but those levels were still within the normal range. As our animal experimentation indicates that the skin is a major target organ for 82Br, applied either by bathing or as an aerosol, we conclude that the higher bromine levels noticed in the psoriatic Danes after their 4-week stay at the Dead Sea may be equally due to their contact with the bromine-containing aerosol and the high bromine level of the Dead Sea waters.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1159/000137756
|
|
|
“Hyperfine electric parameters calculation in Si samples implanted with 57Mn\rightarrow57Fe”. Abreu Y, Cruz CM, Pinera I, Leyva A, Cabal AE, van Espen P, Van Remortel N, Physica: B : condensed matter 445, 1 (2014). http://doi.org/10.1016/J.PHYSB.2014.03.028
Abstract: Nowadays the electronic structure calculations allow the study of complex systems determining the hyperfine parameters measured at a probe atom, including the presence of crystalline defects. The hyperfine electric parameters have been measured by Mossbauer spectroscopy in silicon materials implanted with Mn-57 ->,Fe-57 ions, observing four main contributions to the spectra. Nevertheless, some ambiguities still remain in the Fe-57 Mossbauer spectra interpretation in this case, regarding the damage configurations and its evolution with annealing. In the present work several implantation environments are evaluated and the Fe-57 hyperfine parameters are calculated. The observed correlation among the studied local environments and the experimental observations is presented, and a tentative microscopic description of the behavior and thermal evolution of the characteristic defects local environments of the probe atoms concerning the location of vacancies and interstitial Si in the neighborhood of Fe-57 ions in substitutional and interstitial sites is proposed. (C) 2014 Elsevier B.V. All rights reserved
Keywords: A1 Journal article; Particle Physics Group; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.PHYSB.2014.03.028
|
|
|
“An adhesive conducting electrode material based on commercial mesoporous titanium dioxide as a support for Horseradish peroxidase for bioelectrochemical applications”. Rahemi V, Trashin S, Meynen V, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 146, 689 (2016). http://doi.org/10.1016/J.TALANTA.2015.06.041
Abstract: An adhesive conducting electrode material containing of graphite, biocompatible ion exchange polymer nafion® and commercial mesoporous TiO2 impregnated with horseradish peroxidase (HRP) is prepared and characterized by amperometric, UVvis and N2 sorption methods. The factors influencing the performance of the resulting biosensor are studied in detail. The optimal electrode material consists of 45% graphite, 50% impregnated HRPTiO2 and 5% nafion®. The optimum conditions for H2O2 reduction are an applied potential of 0.3 V and 0.1 mM hydroquinone. Sensitivity and limit of detection in the optimum conditions are 1 A M−1 cm−2 and 1 µM correspondingly. The N2 sorption results show that the pore volume of TiO2 decreases sharply upon adsorption of HRP. The preparation process of the proposed enzyme electrode is straightforward and potentially can be used for preparation of carbon paste electrodes for bioelectrochemical detections.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 7
DOI: 10.1016/J.TALANTA.2015.06.041
|
|
|
“Amperometric flow-injection analysis of phenols induced by reactive oxygen species generated under daylight irradiation of titania impregnated with horseradish peroxidase”. Rahemi V, Trashin S, Hafideddine Z, Van Doorslaer S, Meynen V, Gorton L, De Wael K, Analytical Chemistry 92, 3643 (2020). http://doi.org/10.1021/acs.analchem.9b04617
Abstract: Titanium dioxide (TiO2) is a unique material for biosensing applications due to its capability of hosting enzymes. For the first time, we show that TiO2 can accumulate reactive oxygen species (ROS) under daylight irradiation and can support the catalytic cycle of horseradish peroxidase (HRP) without the need of H2O2 to be present in the solution. Phenolic compounds, such as hydroquinone (HQ) and 4-aminophenol (4-AP), were detected amperometrically in flow-injection analysis (FIA) mode via the use of an electrode modified with TiO2 impregnated with HRP. In contrast to the conventional detection scheme, no H2O2 was added to the analyte solution. Basically, the inherited ability of TiO2 to generate reactive oxygen species is used as a strategy to avoid adding H2O2 in the solution during the detection of phenolic compounds. Electron paramagnetic resonance (EPR) spectroscopy indicates the presence of ROS on titania which, in interaction with HRP, initiate the electrocatalysis toward phenolic compounds. The amperometric response to 4-AP was linear in the concentration range between 0.05 and 2 μM. The sensitivity was 0.51 A M–1 cm–2, and the limit of detection (LOD) 26 nM. The proposed sensor design opens new opportunities for the detection of phenolic traces by HRP-based electrochemical biosensors, yet in a more straightforward and sensitive way following green chemistry principles of avoiding the use of reactive and harmful chemical, such as H2O2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
Times cited: 3
DOI: 10.1021/acs.analchem.9b04617
|
|
|
“Attaching redox proteins onto electrode surfaces by bis-silane”. Trashin S, De Jong M, Meynen V, Dewilde S, De Wael K, ChemElectroChem 3, 1035 (2016). http://doi.org/10.1002/CELC.201600021
Abstract: Immobilization of redox proteins on electrode surfaces is of special interest for mechanistic studies and applications because of a well-controlled redox state of protein molecules by a polarized electrode and fast electron transfer kinetics, free from diffusion limitation. Here, bis-organosilane (1,2-bis(trimethoxysilyl)ethane) was applied as a fresh solution in a pH 7 phosphate buffer without use of any organic solvent, sol-gel or mesoporous bulk matrix. A short aging period of 30 minutes before deposition on the electrodes was optimal for the immobilization of proteins. Three redox proteins (cytochrome c, neuroglobin and GLB-12) were confined to the gold surface of electrodes with high coverages and stability, indicating that the suggested technique is simple, efficient and generic in nature.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.136
Times cited: 4
DOI: 10.1002/CELC.201600021
|
|
|
“The effect of the buffer solution on the adsorption and stability of horse heart myoglobin on commercial mesoporous titanium dioxide : a matter of the right choice”. Loreto S, Cuypers B, Brokken J, Van Doorslaer S, De Wael K, Meynen V, Physical chemistry, chemical physics 19, 13503 (2017). http://doi.org/10.1039/C6CP08585G
Abstract: Despite the numerous studies on the adsorption of different proteins onto mesoporous titanium dioxide and indications on the important role of buffer solutions in bioactivity, a systematic study on the impact of the buffer on the protein incorporation into porous substrates is still lacking. We here studied the interaction between a commercial mesoporous TiO2 and three of the most used buffers for protein incorporation, i.e. HEPES, Tris and phosphate buffer. In addition, this paper analyzes the adsorption of horse heart myoglobin (hhMb) onto commercial mesoporous TiO2 as a model system to test the influence of buffers on the protein incorporation behavior in mesoporous TiO2. N2 sorption analysis, FT-IR and TGA/DTG measurements were used to evaluate the interaction between the buffers and the TiO2 surface, and the effect of such an interaction on hhMb adsorption. Cyclic voltammetry (CV) and electron paramagnetic resonance (EPR) were used to detect changes in the microenvironment surrounding the heme. The three buffers show a completely different interaction with the TiO2 surface, which drastically affects the adsorption of myoglobin as well as its structure and electrochemical activity. Therefore, special attention is required while choosing the buffer medium to avoid misguided evaluation of protein adsorption on mesoporous TiO2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.123
Times cited: 2
DOI: 10.1039/C6CP08585G
|
|
|
“Enzymatic sensor for phenols based on titanium dioxide generating surface confined ROS after treatment with H2O2”. Rahemi V, Trashin S, Hafideddine Z, Meynen V, Van Doorslaer S, De Wael K, Sensors and actuators : B : chemical 283, 343 (2019). http://doi.org/10.1016/J.SNB.2018.12.039
Abstract: Titanium dioxide (TiO2) is a popular material as host matrix for enzymes. We now evidence that TiO2 can accumulate and retain reactive oxygen species after treatment by hydrogen peroxide (H2O2) and support redox cycling of a phenolic analyte between horseradish peroxidase (HRP) and an electrode. The proposed detection scheme is identical to that of second generation biosensors, but the measuring solution requires no dissolved H2O2. This significantly simplifies the analysis and overcomes issues related to H2O2 being present (or generated) in the solution. The modified electrodes showed rapid stabilization of the baseline, a low noise level, fast realization of a steady-state current response, and, in addition, improved sensitivity and limit of detection compared to the conventional approach, i.e. in the presence of H2O2 in the measuring solution. Hydroquinone, 4-aminophenol, and other phenolic compounds were successfully detected at sub-μM concentrations. Particularly, a linear response in the concentration range between 0.025 and 2 μM and LOD of 24 nM was demonstrated for 4-aminophenol. The proposed sensor design goes beyond the traditional concept with three sensors generations offering a new possibility for the development of enzymatic sensors based on peroxidases and the formation of ROS on titania after treatment with H2O2.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 5.401
Times cited: 1
DOI: 10.1016/J.SNB.2018.12.039
|
|
|
“SnIV-containing layered double hydroxides as precursors for nano-sized ZnO/SnO2 photocatalysts”. Seftel EM, Popovici E, Mertens M, Stefaniak EA, Van Grieken R, Cool P, Vansant EF, Applied catalysis : B : environmental 84, 699 (2008). http://doi.org/10.1016/J.APCATB.2008.06.006
Abstract: Sn4+-containing LDH was prepared using the co-precipitation method at constant pH, and characterized using X-ray diffraction, UVvis diffuse reflectance spectroscopy and TG/DTG methods. The obtained product was further exposed to different thermal treatments in order to obtain nano-sized coupled ZnO/SnO2 systems with enhanced photocatalytic performances than the ones obtained by mixing the two semiconductor oxides. The formation of a well-defined ZnO/SnO2 system and the crystallite size, fully investigated using XRD, micro-Raman scattering and UVvis DR techniques, were found to be influenced by the nature of the precursors and the calcination temperature. The photocatalytic activity of the ZnO/SnO2 systems, evaluated for the photodegradation of methyl orange (MO) dye, was studied as a function of the initial pH, catalyst loading and the calcination temperature. The metal dispersion supplied by layered structures proved to be an advantage when preparing coupled ZnO/SnO2 systems, the photocatalytic activity being 2.3 times higher comparing with the physical mixtures performances. The maximum photocatalytic activity of the coupled ZnO/SnO2 system having a layered precursor was observed when using neutral pH, at a catalyst loading of 1 g/L calcined at 600 °C for 4 h.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.APCATB.2008.06.006
|
|
|
“Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data”. Osán J, de Hoog J, Worobiec A, Ro C-U, Oh K-Y, Szalóki I, Van Grieken R, Analytica chimica acta 446, 211 (2001)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Application of thin-window EPMA to environmental problems in Hungary”. Osán J, Kurunczi S, Török S, Worobiec A, Van Grieken R, Microchimica acta 139, 111 (2002). http://doi.org/10.1007/S006040200048
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040200048
|
|
|
“Characterisation of aerosol particles in the São Paulo Metropolitan Area”. de Miranda RM, de Fátima Andrade M, Worobiec A, Van Grieken R, Atmospheric environment : an international journal 36, 345 (2002). http://doi.org/10.1016/S1352-2310(01)00363-6
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(01)00363-6
|
|
|
“Characterisation of concentrates of heavy mineral sands by micro-Raman spectrometry and CC-SEM/EDX with HCA”. Worobiec A, Stefaniak EA, Potgieter-Vermaak S, Sawlowicz Z, Spolnik Z, Van Grieken R, Applied geochemistry 22, 2078 (2007). http://doi.org/10.1016/J.APGEOCHEM.2007.05.003
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.APGEOCHEM.2007.05.003
|
|
|
“Characterisation of individual aerosol particles for atmospheric and cultural heritage studies”. Van Grieken R, Gysels K, Hoornaert S, Joos P, Osán J, Szalóki I, Worobiec A, Water, air and soil pollution 123, 215 (2000). http://doi.org/10.1023/A:1005215304729
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1005215304729
|
|
|
“Characterisation of sugar cane combustion particles in the Araraquara region, Southeast Brazil”. Godoi RHM, Godoi AFL, Worobiec A, Andrade SJ, de Hoog J, Santiago-Silva MR, Van Grieken R, Microchimica acta 145, 53 (2004). http://doi.org/10.1007/S00604-003-0126-X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-003-0126-X
|
|
|
“Chemical characterization of airborne particles in St. Martinus Cathedral in Weert, The Netherlands”. Spolnik Z, Worobiec A, Injuk J, Neilen D, Schellen H, Van Grieken R, Microchimica acta 145, 223 (2004). http://doi.org/10.1007/S00604-003-0158-2
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-003-0158-2
|
|
|
“Combined SEM/EDX and micro-Raman spectroscopy analysis of uranium minerals from a former uranium mine”. Stefaniak EA, Alsecz A, Frost R, Máthé, Z, Sajó, IE, Török S, Worobiec A, Van Grieken R, Journal of hazardous materials 168, 416 (2009). http://doi.org/10.1016/J.JHAZMAT.2009.02.057
Abstract: Samples of the secondary uranium minerals collected in the abandoned uranium mine at Pecs (Hungary) were investigated by two micro-techniques: scanning electron microscopy (SEM/EDX) and micro-Raman spectroscopy (MRS). They were applied to locate U-rich particles and identify the chemical form and oxidation state of the uranium compounds. The most abundant mineral was a K and/or Na uranyl sulphate (zippeite group). U(VI) was also present in the form showing intensive Raman scattering at 860 cm−1 which can be attributed to uranium trioxide. This research has shown the successful application of micro-Raman spectroscopy for the identification of uranyl mineral species on the level of individual particles.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JHAZMAT.2009.02.057
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“EPXMA survey of shelf sediments (Southern Bight, North Sea): a glance beyond the XRD-invisible”. de Maeyer-Worobiec A, Dekov VM, Laane RWPM, Van Grieken R, Microchemical journal 91, 21 (2009). http://doi.org/10.1016/J.MICROC.2008.07.001
Abstract: Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a reasonable analytical reliability. XRD studies of such a type of sediments with monotonous mineral composition are not able to provide mineralogical information beyond the main well-crystalline minerals and the mineralogical quantitative characteristic of the sediment based on XRD estimations are incorrect. The EPXMA mineralogical interpretations are based on the statistical evaluation of a huge data set (thousands of mineral particles) and provide a rather correct quantitative determination of the main minerals. The comparative EPXMAXRF study revealed that the Al, Si, K, Ca, Fe and to some extent Ti contents estimated by EPXMA are fairly reliable. In this respect the accuracy of the EPXMA-based mineral identification of the pure silicates, pure aluminosilicates, and Al-, Ca-, Fe- and Ti-containing minerals with simple composition is very high. Mg-calcite, augite and apatite determinations are assessed to be correct. The supposed accuracy of the clay mineral determinations is slightly lower (7080%) than that of the other main minerals due to the complex and varying composition of the clays. The identification of XRD-invisible accessory minerals and quantification of their presence in the sediments is an essential advantage of the EPXMA, which makes it a useful approach in tracing the origin of the sediments, the pathways of their transport and the geochemical processes they have undergone. However, the EPXMA has several flaws, which need to be solved in the future sediment investigations: (1) calibration with natural standards is needed in order to provide a higher accuracy of the mineral determinations; (2) any EPXMA study of sediments needs to be secured with XRF examinations of selected samples since EPXMA gives only semi-quantitative information about the abundance of the elements; (3) ultra-thin window EPXMA of low-Z elements has to be used since some of them (O, C) are always present in the main sediment components: silicates, aluminosilicates, carbonates and metal oxyhydroxides; (4) the interpretations of the clay fraction have to be supported with detailed XRD investigations of selected samples, while the mineralogy of the silt and sand fractions needs to be backed up with optical microscopy studies. The information from different analytical techniques (EPXMA with XRFXRD-optical microscopy of selected samples) combined with the knowledge about the most possible minerals in a given environment, would give the most reliable results in studying mineralogical composition of shelf sediments.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2008.07.001
|
|
|
“Heterogeneity assessment in individual CaCO3-CaSO4 particles using ultrathin window electron probe X-ray microanalysis”. Ro C-U, Oh K-Y, Osán J, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 73, 4574 (2001). http://doi.org/10.1021/AC010438X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC010438X
|
|
|
“Methodology for light element analysis of individual aerosol particles using thin-window EPMA”. Osán J, Ro C-U, Szalóki I, Worobiec A, de Hoog J, Joos P, Van Grieken R, Journal of aerosol science 31, 765 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Molecular and elemental characterisation of mineral particles by means of parallel micro-Raman spectrometry and Scanning Electron Microscopy/Energy Dispersive X-ray Analysis”. Stefaniak EA, Worobiec A, Potgieter-Vermaak S, Alsecz A, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 824 (2006). http://doi.org/10.1016/J.SAB.2006.04.009
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2006.04.009
|
|
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
|
|
“Optimisation of light element analysis of individual particles using UTW-EPMA”. de Hoog J, Osán J, Worobiec A, Ro C-U, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 388 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Optimization of experimental conditions of thin-window EPMA for ligh-element analysis of individual environmental particles”. Szalóki I, Osán J, Worobiec A, de Hoog J, Van Grieken R, X-ray spectrometry 30, 143 (2001). http://doi.org/10.1002/XRS.473.ABS
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.473.ABS
|
|
|
“Particulate ba-barite and acantharians in the Southern Ocean during the European iron fertilization experiment (EIFEX)”. Jacquet SHM, Henjes J, Dehairs F, Worobiec A, Savoye N, Cardinal D, Journal of geophysical research: G: biogeosciences 112, 04006 (2007). http://doi.org/10.1029/2006JG000394
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/2006JG000394
|
|
|
“Recognition of uranium oxides in soil particulate matter by means of ì-Raman spectrometry”. Stefaniak EA, Sajó, I, Alsecz A, Worobiec A, Máthé, Z, Török S, Van Grieken R, Journal of nuclear materials 381, 278 (2008). http://doi.org/10.1016/J.JNUCMAT.2008.08.036
Abstract: Soil samples from an abandoned uranium mine have been investigated in order to determine the molecular phases of uranium compounds. The experiments were carried out with soil particulate matter, collected randomly from the area of the formerly exploited ore. To select the particles rich with uranium, scanning electron microscopy with energy-dispersive X-ray attachment (SEM/EDX) was applied first. Afterwards, the particles were relocated and measured by l-Raman spectrometry (MRS). Residues of the main deposit, uraninite UO2, were detected, along with its alteration products. In terms of Raman scattering properties, uranium oxides are quite sensitive to the laser beam wavelength, which results in very specific features of their Raman spectra. In this paper the Raman spectra of uranium oxides of different origin and oxidation states, measured with 514 and 785 nm lasers, are also presented
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JNUCMAT.2008.08.036
|
|
|
“Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles”. Worobiec A, Kaplinski A, Van Grieken R, X-ray spectrometry 34, 245 (2005). http://doi.org/10.1002/XRS.807
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.807
|
|
|
“Single-particle analysis of aerosols at Cheju Island, Korea, using low-Z electron probe X-ray microanalysis: a direct proof of nitrate formation from sea salts”. Ro C-U, Oh K-Y, Kim H, Kim YP, Lee CB, Kim K-H, Kang CH, Osán J, de Hoog J, Worobiec A, Van Grieken R, Environmental science and technology 35, 4487 (2001). http://doi.org/10.1021/ES0155231
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES0155231
|
|
|
“Speciation of selected metals in aerosol samples by TXRF after sequential leaching”. Samek L, Ostachowicz B, Worobiec A, Spolnik Z, Van Grieken R, X-ray spectrometry 35, 226 (2006). http://doi.org/10.1002/XRS.905
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.905
|
|