|
“Plasma based co2 conversion: a combined modeling and experimental study”. Bogaerts A, Snoeckx R, Berthelot A, Heijkers S, Wang W, Sun S, Van Laer K, Ramakers M, Michielsen I, Uytdenhouwen Y, Meynen V, Cool P, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: In recent years there is increased interest in plasma-based CO2 conversion. Several plasma setups are being investigated for this purpose, but the most commonly used ones are a dielectric barrier discharge (DBD), a microwave (MW) plasma and a gliding arc (GA) reactor. In this proceedings paper, we will show results from our experiments in a (packed bed) DBD reactor and in a vortex-flow GA reactor, as well as from our model calculations for the detailed plasma chemistry in a DBD, MW and GA, for pure CO2 as well as mixtures of CO2 with N-2, CH4 and H2O.
Keywords: P1 Proceeding; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Cluster issue on plasma modelling”. van Dijk J, Kroesen GMW, Bogaerts A London (2009).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Colloquium Spectroscopicum Internationale 34: a collection of papers presented at the Colloquium Spectroscopicum Internationale, Antwerp, Belgium, 4-9 September 2005”. Janssens K, Bogaerts A, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Colloquium Spectroscopicum Internationale 34 (CSI 34), Antwerp, Belgium, 4-9 September 2005”. Bogaerts A, Janssens K, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
“Glow discharge mass spectrometry, methods”. Bogaerts A Academic Press, San Diego, Calif., page 669 (2000).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Glow discharges in emission and mass spectrometry”. Jakubowski N, Bogaerts A, Hoffmann V Blackwell, Sheffield (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Mathematical modelling of an analytical glow discharge”. Bogaerts A, van Straaten M, Gijbels R KD Marketing Services, Milton Keynes, page 82 (1995).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling network for argon glow discharge plasmas with copper cathode”. Bogaerts A, Gijbels R Nova, New York, page 1 (2002).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modelling of radio frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 525 (1999).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Numerical modelling of analytical glow discharges”. Bogaerts A, Gijbels R Wiley, Chichester, page 155 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Plasma models”. Bogaerts A, Gijbels R Wiley, New York, page 176 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling for a Better Understanding of Plasma-Based CO2 Conversion”. Bogaerts A, Snoeckx R, Trenchev G, Wang W In: Britun N, Silva T (eds) Plasma Chemistry and Gas Conversion. IntechOpen, Rijeka (2018).
Abstract: This chapter discusses modeling efforts for plasma-based CO2 conversion, which are needed to obtain better insight in the underlying mechanisms, in order to improve this application. We will discuss two types of (complementary) modeling efforts that are most relevant, that is, (i) modeling of the detailed plasma chemistry by zero-dimensional (0D) chemical kinetic models and (ii) modeling of reactor design, by 2D or 3D fluid dynamics models. By showing some characteristic calculation results of both models, for CO2 splitting and in combination with a H-source, and for packed bed DBD and gliding arc plasma, we can illustrate the type of information they can provide.
Keywords: H1 Book Chapter; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
DOI: 10.5772/intechopen.80436
|
|
“Computer simulations of laser ablation, plume expansion and plasma formation”. Bogaerts A, Aghaei M, Autrique D, Lindner H, Chen Z, Wendelen W Trans Tech, Aedermannsdorf, page 1 (2011).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 8
DOI: 10.4028/www.scientific.net/AMR.227.1
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Steiner RE, Barshick CM, Bogaerts A Wiley, Chichester, page 1 (2009).
Abstract: Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupolemass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (5001500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (e.g. Ar, Ne, and Xe) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. Unfortunately, the GD source functions optimally in a dry environment, making analysis of solutions more difficult. These sources also suffer from difficulties associated with analyzing nonconductingsamples. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This section focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GDsources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with avariety of spectroscopic and spectrometric instruments for both quantitative and qualitative analysis.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Investigation of the electron distribution functions in low pressure electron cyclotron resonance discharges”. Kaganovich I, Misina M, Bogaerts A, Gijbels R Kluwer Academic, Dordrecht, page 543 (1999).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling aspects of plasma-enhanced chemical vapor deposition of carbon-based materials”. Neyts E, Mao M, Eckert M, Bogaerts A CRC Press, Boca Raton, Fla, page 245 (2012).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Modeling network for argon glow discharges: the output cannot be better than the input”. Bogaerts A, Gijbels R American Institute of Physics, Melville, N.Y., page 49 (2000).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|
“Modeling of the magnetron discharge”. Bogaerts A, Kolev I, Buyle G Springer, Berlin, page 61 (2008).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A John Wiley & Sons, Chichester, page 1 (2016).
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
“Comment on 'Integral cross sections for electron impact excitation of electronic states of N2'”. Cenian A, Chernukho A, Bogaerts A, Gijbels R, Journal of physics: B : atomic and molecular physics 35, 5163 (2002). http://doi.org/10.1088/0953-4075/35/24/401
Abstract: Based on the existing experimental data and their statistical errors, it is not possible to make a sound recommendation of the cross-section set of Campbell et al (J. Phys. B: At. Mol. Opt. Phys. 34 (2001) 1185). We comment on this paper.
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.792
Times cited: 2
DOI: 10.1088/0953-4075/35/24/401
|
|
“Plasma modelling and numerical simulation”. van Dijk J, Kroesen GMW, Bogaerts A, Journal of physics: D: applied physics 42, 190301 (2009). http://doi.org/10.1088/0022-3727/42/19/190301
Abstract: Plasma modelling is an exciting subject in which virtually all physical disciplines are represented. Plasma models combine the electromagnetic, statistical and fluid dynamical theories that have their roots in the 19th century with the modern insights concerning the structure of matter that were developed throughout the 20th century. The present cluster issue consists of 20 invited contributions, which are representative of the state of the art in plasma modelling and numerical simulation. These contributions provide an in-depth discussion of the major theories and modelling and simulation strategies, and their applications to contemporary plasma-based technologies. In this editorial review, we introduce and complement those papers by providing a bird's eye perspective on plasma modelling and discussing the historical context in which it has surfaced.
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 64
DOI: 10.1088/0022-3727/42/19/190301
|
|
“Response to “Comment on 'Laser ablation of Cu and plume expansion into 1 atm ambient gas'&rdquo, [J. Appl. Phys. 115, 166101 (2014)]”. Chen Z, Bogaerts A, Journal of applied physics 115, 166102 (2014). http://doi.org/10.1063/1.4872326
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 1
DOI: 10.1063/1.4872326
|
|
“Special issue on fundamentals of plasmasurface interactions”. Bogaerts A, Neyts EC, Rousseau A, Journal of physics: D: applied physics 47, 220301 (2014). http://doi.org/10.1088/0022-3727/47/22/220301
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 2
DOI: 10.1088/0022-3727/47/22/220301
|
|
“Special Issue of Papers by Plenary and Topical Invited Lecturers at the 22nd International Symposium on Plasma Chemistry (ISPC 22), 5–10 July 2015, Antwerp, Belgium: Introduction”. Bogaerts A, van de Sanden R, Plasma chemistry and plasma processing 36, 1 (2016). http://doi.org/10.1007/s11090-015-9691-0
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.355
DOI: 10.1007/s11090-015-9691-0
|
|
“Plasma processes and polymers third special issue on plasma and cancer”. Laroussi M, Bogaerts A, Barekzi N, Plasma processes and polymers 13, 1142 (2016). http://doi.org/10.1002/ppap.201600193
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 1
DOI: 10.1002/ppap.201600193
|
|
“Special issue on numerical modelling of low-temperature plasmas for various applications –, part II: Research papers on numerical modelling for various plasma applications”. Bogaerts A, Alves LL, Plasma processes and polymers 14, 1790041 (2017). http://doi.org/10.1002/ppap.201790041
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 2
DOI: 10.1002/ppap.201790041
|
|
“Special issue: Plasma Conversion”. Nozaki T, Bogaerts A, Tu X, Sanden R, Plasma processes and polymers 14, 1790061 (2017). http://doi.org/10.1002/ppap.201790061
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
DOI: 10.1002/ppap.201790061
|
|
“Special Issue on Numerical Modelling of Low-Temperature Plasmas for Various Applications –, Part I: Review and Tutorial Papers on Numerical Modelling Approaches”. Alves LL, Bogaerts A, Plasma processes and polymers 14, 1690011 (2017). http://doi.org/10.1002/ppap.201690011
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.846
Times cited: 3
DOI: 10.1002/ppap.201690011
|
|
“Editorial Catalysts: Special Issue on Plasma Catalysis”. Bogaerts A, Catalysts 9, 196 (2019). http://doi.org/10.3390/catal9020196
Abstract: Plasma catalysis is gaining increasing interest for various gas conversion applications, such as CO2 conversion into value-added chemicals and fuels, N2 fixation for the synthesis of NH3 or NOx, and CH4 conversion into higher hydrocarbons or oxygenates [...]
Keywords: Editorial; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.082
Times cited: 1
DOI: 10.3390/catal9020196
|