|
“Hybrid Monte Carlo-fluid model of a direct current glow discharge”. Bogaerts A, Gijbels R, Goedheer W, Journal of applied physics 78, 2233 (1995). http://doi.org/10.1063/1.360139
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 117
DOI: 10.1063/1.360139
|
|
|
“Hybrid Monte-Carlo-fluid modeling network for an argon/hydrogen direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 57, 1071 (2002). http://doi.org/10.1016/S0584-8547(02)00047-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 68
DOI: 10.1016/S0584-8547(02)00047-2
|
|
|
“Hydrodynamic model of matrix-assisted laser desorption mass spectrometry”. Vertes A, Irinyi G, Gijbels R, Analytical chemistry 65, 2389 (1993). http://doi.org/10.1021/ac00065a036
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 100
DOI: 10.1021/ac00065a036
|
|
|
“Hydrogeochemical exploration for gold in the Osilo area, Sardinia, Italy”. Cidu R, Fanfani L, Shand P, Edmunds WM, Van 't dack L, Gijbels R, Applied geochemistry 10, 517 (1995). http://doi.org/10.1016/0883-2927(95)00022-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.268
Times cited: 10
DOI: 10.1016/0883-2927(95)00022-4
|
|
|
“Imaging TOF-SIMS for the surface analysis of silver halide microcrystals”. Lenaerts J, Gijbels R, van Vaeck L, Verlinden G, Geuens I, Applied surface science 203/204, 614 (2003). http://doi.org/10.1016/S0169-4332(02)00777-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 7
DOI: 10.1016/S0169-4332(02)00777-8
|
|
|
“The impact of quantum chemical methods on the interpretation of molecular spectra of carbon clusters (review article)”. Martin JML, François JP, Gijbels R, Journal of molecular structure 294, 21 (1993). http://doi.org/10.1016/0022-2860(93)80305-F
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.602
Times cited: 21
DOI: 10.1016/0022-2860(93)80305-F
|
|
|
“Improved hybrid Monte Carlo-fluid model for the electrical characteristics in an analytical radiofrequency glow discharge in argon”. Bogaerts A, Gijbels R, Goedheer W, Journal of analytical atomic spectrometry 16, 750 (2001). http://doi.org/10.1039/b103768b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/b103768b
|
|
|
“Incorporating the gas flow in a numerical model of rf discharges in methane”. Okhrimovskyy A, Bogaerts A, Gijbels R, Journal of applied physics 96, 3070 (2004). http://doi.org/10.1063/1.1782951
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 11
DOI: 10.1063/1.1782951
|
|
|
“Influence of axial and radial diffusion processes on the analytical performance of a glow discharge cell”. van Straaten M, Gijbels R, Vertes A, Analytical chemistry 64, 1855 (1992). http://doi.org/10.1021/ac00041a021
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 5.636
Times cited: 43
DOI: 10.1021/ac00041a021
|
|
|
“Influence of electron recapture by the cathode upon the discharge characteristics in dc planar magnetrons”. Kolev I, Bogaerts A, Gijbels R, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 72, 056402 (2005). http://doi.org/10.1103/PhysRevE.72.056402
Abstract: In dc magnetrons the electrons emitted from the cathode may return there due to the applied magnetic field. When that happens, they can be recaptured or reflected back into the discharge, depending on the value of the reflection coefficient (RC). A 2d3v (two-dimensional in coordinate and three-dimensional in velocity space) particle-in-cellMonte Carlo model, including an external circuit, is developed to determine the role of the electron recapture in the discharge processes. The detailed discharge structure as a function of RC for two pressures (4 and 25mtorr) is studied. The importance of electron recapture is clearly manifested, especially at low pressures. The results indicate that the discharge characteristics are dramatically changed with varying RC between 0 and 1. Thus, the electron recapture at the cathode appears to be a significant mechanism in magnetron discharges and RC a very important parameter in their correct quantitative description that should be dealt with cautiously.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 29
DOI: 10.1103/PhysRevE.72.056402
|
|
|
“Interpretation of TOF-SIMS depth profiles from ultrashallow high-k dielectric stacks assisted by hybrid collisional computer simulation”. Ignatova VA, Möller W, Conard T, Vandervorst W, Gijbels R, Applied physics A : materials science &, processing 81, 71 (2005). http://doi.org/10.1007/s00339-005-3239-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.455
Times cited: 4
DOI: 10.1007/s00339-005-3239-8
|
|
|
“Investigation of growth mechanisms of clusters in a silane discharge with the use of a fluid model”. de Bleecker K, Bogaerts A, Goedheer W, Gijbels R, IEEE transactions on plasma science 32, 691 (2004). http://doi.org/10.1109/TPS.2004.826095
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 29
DOI: 10.1109/TPS.2004.826095
|
|
|
“Investigation of laser output power saturation in the He-Cu+ IR hollow cathode discharge laser by experiments and numerical modeling”. Bogaerts A, Gijbels R, Grozeva M, Sabotinov N, Physica scripta T105, 90 (2003). http://doi.org/10.1238/Physica.Topical.105a00090
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
DOI: 10.1238/Physica.Topical.105a00090
|
|
|
“The ion- and atom-induced secondary electron emission yield: numerical study for the effect of clean and dirty cathode surfaces”. Bogaerts A, Gijbels R, Plasma sources science and technology 11, 27 (2002). http://doi.org/10.1088/0963-0252/11/1/303
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 51
DOI: 10.1088/0963-0252/11/1/303
|
|
|
“Ion-bombardment artifact in TOF-SIMS analysis of ZrO2/SiO2/Si stacks”. de Witte H, Conard T, Vandervorst W, Gijbels R, Applied surface science 203, 523 (2003). http://doi.org/10.1016/S0169-4332(02)00728-6
Abstract: We analyzed ultra-thin ZrO2/SiO2/Si gate dielectrics under post-deposition anneals in dry O-2 at temperatures from 500 to 700 degreesC. TOF-SIMS profiling of ZrO2/SiO2/Si stacks is hampered by many sputter induced artifacts. The depletion of oxygen leads to a decrease in SIMS intensities. However, preferential sputtering is accompanied by transport of the depleted species towards the surface. Due to recoil implantation oxygen gets piled-up near the ZrO2/SiO2 interface. Either normal or radiation-enhanced diffusion transports oxygen back to the surface. Simultaneously also segregation of zirconium towards and through the interface is observed, resulting in a large zirconium tail in the underlying silicon substrate. (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 15
DOI: 10.1016/S0169-4332(02)00728-6
|
|
|
“Kinetic modeling of relaxation phenomena after photodetachment in a rf electronegative SiH4 discharge”. Yan M, Bogaerts A, Gijbels R, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 63 (2001). http://doi.org/10.1103/PhysRevE.63.026405
Abstract: The global relaxation process after pulsed laser induced photodetachment in a rf electronegative SIH4 discharge is studied by a self-consistent kinetic one-dimensional particle-in-cell-Monte Carlo model. Our results reveal a comprehensive physical picture of the relaxation process, including the main plasma variables, after a perturbation up to the full recovery of the steady state. A strong influence of the photodetachment on the discharge is found, which results from an increase of the electron density, leading to a weaker bulk field, and hence to a drop in the high energy tail of the electron energy distribution function (EEDF), a reduction of the reaction rates of electron impact attachment and ionization, and a subsequent decrease of the positive and negative ion densities. All the plasma quantities related to electrons recover synchronously. The recovery time of the ion densities is about 1-2 orders of magnitude longer than that of the electrons due to different recovery mechanisms. The modeled behavior of all the charged particles agrees very well with experimental results from the literature. In addition, our work clarifies some unclear processes assumed in the literature, such as the relaxation of the EEDF, the evolution of the electric field, and the recovery of negative ions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 4
DOI: 10.1103/PhysRevE.63.026405
|
|
|
“Laser ablation for analytical sampling: what can we learn from modeling?”.Bogaerts A, Chen Z, Gijbels R, Vertes A, Spectrochimica acta: part B : atomic spectroscopy 58, 1867 (2003). http://doi.org/10.1016/j.sab.2003.08.004
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 321
DOI: 10.1016/j.sab.2003.08.004
|
|
|
“Laser ionization mass spectrometry for the characterization of solid materials”. van Vaeck L, van Roy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 21, 53 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 10
|
|
|
“Laser ionization mass-spectrometry for the characterization of solid materials”. van Vaeck L, Vanroy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 20, S29 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Laser microprobe mass spectrometry of quaternary phosphonium salts: direct versus matrix-assisted laser desorption”. Claereboudt J, Claeys M, Geise H, Gijbels R, Vertes A, Journal of the American Society for Mass Spectrometry 4, 798 (1993). http://doi.org/10.1016/1044-0305(93)80038-Z
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.945
Times cited: 17
DOI: 10.1016/1044-0305(93)80038-Z
|
|
|
“Laser microprobe mass spectrometry: principle and applications in biology and medicine”. van Vaeck L, Poels K, de Nollin S, Hachimi A, Gijbels R, Cell biology international 21, 635 (1997). http://doi.org/10.1006/cbir.1997.0198
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.831
Times cited: 6
DOI: 10.1006/cbir.1997.0198
|
|
|
“Local and fast relaxation phenomena after laser-induced photodetachment in a strongly electronegative rf discharge”. Yan M, Bogaerts A, Gijbels R, Goedheer WJ, Physical review : E : statistical, nonlinear, and soft matter physics 65, 016408 (2002). http://doi.org/10.1103/PhysRevE.65.016408
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 2
DOI: 10.1103/PhysRevE.65.016408
|
|
|
“Mass spectrometric analysis of inorganic solids: GDMS and other methods”. Gijbels R, van Straaten M, Bogaerts A, Advances in mass spectrometry 13, 241 (1995)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 12
|
|
|
“A mass spectrometric study of the dissolution behavior of sanidine”. Adriaens A, Van 't dack L, Adams F, Gijbels R, Microchimica acta 120, 139 (1995). http://doi.org/10.1007/BF01244427
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.741
Times cited: 1
DOI: 10.1007/BF01244427
|
|
|
“Mathematical description of a direct current glow discharge in argon”. Bogaerts A, Gijbels R, Fresenius' journal of analytical chemistry 355, 853 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 12
|
|
|
“Matrix-enhanced secondary ion mass spectrometry: the influence of MALDI matrices on molecular ion yields of thin organic films”. Adriaensen L, Vangaever F, Lenaerts J, Gijbels R, Rapid communications in mass spectrometry 19, 1017 (2005). http://doi.org/10.1002/rcm.1881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 24
DOI: 10.1002/rcm.1881
|
|
|
“Metal-assisted secondary ion mass spectrometry: the influence of Ag and Au deposition on molecular ion yields”. Adriaensen L, Vangaever F, Gijbels R, Analytical chemistry 76, 6777 (2004). http://doi.org/10.1021/ac049108d
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 67
DOI: 10.1021/ac049108d
|
|
|
“Microanalysis of individual silver halide microcrystals”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Scanning microscopy 7, 17 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 7
|
|
|
“Microprobe speciation analysis of inorganic solids by Fourier transform laser mass spectrometry”. Poels K, van Vaeck L, Gijbels R, Analytical chemistry 70, 504 (1998). http://doi.org/10.1021/ac9709108
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.32
Times cited: 32
DOI: 10.1021/ac9709108
|
|
|
“Modeling of a capacitively coupled radio-frequency methane plasma: comparison between a one-dimensional and a two-dimensional fluid model”. Herrebout D, Bogaerts A, Yan M, Gijbels R, Goedheer W, Vanhulsel A, Journal of applied physics 92, 2290 (2002). http://doi.org/10.1063/1.1500789
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 15
DOI: 10.1063/1.1500789
|
|