|
“Combined SEM/EDX and micro-Raman spectroscopy analysis of uranium minerals from a former uranium mine”. Stefaniak EA, Alsecz A, Frost R, Máthé, Z, Sajó, IE, Török S, Worobiec A, Van Grieken R, Journal of hazardous materials 168, 416 (2009). http://doi.org/10.1016/J.JHAZMAT.2009.02.057
Abstract: Samples of the secondary uranium minerals collected in the abandoned uranium mine at Pecs (Hungary) were investigated by two micro-techniques: scanning electron microscopy (SEM/EDX) and micro-Raman spectroscopy (MRS). They were applied to locate U-rich particles and identify the chemical form and oxidation state of the uranium compounds. The most abundant mineral was a K and/or Na uranyl sulphate (zippeite group). U(VI) was also present in the form showing intensive Raman scattering at 860 cm−1 which can be attributed to uranium trioxide. This research has shown the successful application of micro-Raman spectroscopy for the identification of uranyl mineral species on the level of individual particles.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JHAZMAT.2009.02.057
|
|
|
“Comprehensive microanalytical study of welding aerosols with x-ray and Raman based methods”. Worobiec A, Stefaniak EA, Kiro S, Oprya M, Bekshaev A, Spolnik Z, Potgieter-Vermaak SS, Ennan A, Van Grieken R, X-ray spectrometry 36, 328 (2007). http://doi.org/10.1002/XRS.979
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.979
|
|
|
“EPXMA survey of shelf sediments (Southern Bight, North Sea): a glance beyond the XRD-invisible”. de Maeyer-Worobiec A, Dekov VM, Laane RWPM, Van Grieken R, Microchemical journal 91, 21 (2009). http://doi.org/10.1016/J.MICROC.2008.07.001
Abstract: Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a reasonable analytical reliability. XRD studies of such a type of sediments with monotonous mineral composition are not able to provide mineralogical information beyond the main well-crystalline minerals and the mineralogical quantitative characteristic of the sediment based on XRD estimations are incorrect. The EPXMA mineralogical interpretations are based on the statistical evaluation of a huge data set (thousands of mineral particles) and provide a rather correct quantitative determination of the main minerals. The comparative EPXMAXRF study revealed that the Al, Si, K, Ca, Fe and to some extent Ti contents estimated by EPXMA are fairly reliable. In this respect the accuracy of the EPXMA-based mineral identification of the pure silicates, pure aluminosilicates, and Al-, Ca-, Fe- and Ti-containing minerals with simple composition is very high. Mg-calcite, augite and apatite determinations are assessed to be correct. The supposed accuracy of the clay mineral determinations is slightly lower (7080%) than that of the other main minerals due to the complex and varying composition of the clays. The identification of XRD-invisible accessory minerals and quantification of their presence in the sediments is an essential advantage of the EPXMA, which makes it a useful approach in tracing the origin of the sediments, the pathways of their transport and the geochemical processes they have undergone. However, the EPXMA has several flaws, which need to be solved in the future sediment investigations: (1) calibration with natural standards is needed in order to provide a higher accuracy of the mineral determinations; (2) any EPXMA study of sediments needs to be secured with XRF examinations of selected samples since EPXMA gives only semi-quantitative information about the abundance of the elements; (3) ultra-thin window EPXMA of low-Z elements has to be used since some of them (O, C) are always present in the main sediment components: silicates, aluminosilicates, carbonates and metal oxyhydroxides; (4) the interpretations of the clay fraction have to be supported with detailed XRD investigations of selected samples, while the mineralogy of the silt and sand fractions needs to be backed up with optical microscopy studies. The information from different analytical techniques (EPXMA with XRFXRD-optical microscopy of selected samples) combined with the knowledge about the most possible minerals in a given environment, would give the most reliable results in studying mineralogical composition of shelf sediments.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2008.07.001
|
|
|
“Heterogeneity assessment in individual CaCO3-CaSO4 particles using ultrathin window electron probe X-ray microanalysis”. Ro C-U, Oh K-Y, Osán J, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 73, 4574 (2001). http://doi.org/10.1021/AC010438X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC010438X
|
|
|
“Methodology for light element analysis of individual aerosol particles using thin-window EPMA”. Osán J, Ro C-U, Szalóki I, Worobiec A, de Hoog J, Joos P, Van Grieken R, Journal of aerosol science 31, 765 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Molecular and elemental characterisation of mineral particles by means of parallel micro-Raman spectrometry and Scanning Electron Microscopy/Energy Dispersive X-ray Analysis”. Stefaniak EA, Worobiec A, Potgieter-Vermaak S, Alsecz A, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 824 (2006). http://doi.org/10.1016/J.SAB.2006.04.009
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2006.04.009
|
|
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
|
|
“Optimisation of light element analysis of individual particles using UTW-EPMA”. de Hoog J, Osán J, Worobiec A, Ro C-U, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 388 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Optimization of experimental conditions of thin-window EPMA for ligh-element analysis of individual environmental particles”. Szalóki I, Osán J, Worobiec A, de Hoog J, Van Grieken R, X-ray spectrometry 30, 143 (2001). http://doi.org/10.1002/XRS.473.ABS
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.473.ABS
|
|
|
“Recognition of uranium oxides in soil particulate matter by means of ì-Raman spectrometry”. Stefaniak EA, Sajó, I, Alsecz A, Worobiec A, Máthé, Z, Török S, Van Grieken R, Journal of nuclear materials 381, 278 (2008). http://doi.org/10.1016/J.JNUCMAT.2008.08.036
Abstract: Soil samples from an abandoned uranium mine have been investigated in order to determine the molecular phases of uranium compounds. The experiments were carried out with soil particulate matter, collected randomly from the area of the formerly exploited ore. To select the particles rich with uranium, scanning electron microscopy with energy-dispersive X-ray attachment (SEM/EDX) was applied first. Afterwards, the particles were relocated and measured by l-Raman spectrometry (MRS). Residues of the main deposit, uraninite UO2, were detected, along with its alteration products. In terms of Raman scattering properties, uranium oxides are quite sensitive to the laser beam wavelength, which results in very specific features of their Raman spectra. In this paper the Raman spectra of uranium oxides of different origin and oxidation states, measured with 514 and 785 nm lasers, are also presented
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JNUCMAT.2008.08.036
|
|
|
“Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles”. Worobiec A, Kaplinski A, Van Grieken R, X-ray spectrometry 34, 245 (2005). http://doi.org/10.1002/XRS.807
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.807
|
|
|
“Single-particle analysis of aerosols at Cheju Island, Korea, using low-Z electron probe X-ray microanalysis: a direct proof of nitrate formation from sea salts”. Ro C-U, Oh K-Y, Kim H, Kim YP, Lee CB, Kim K-H, Kang CH, Osán J, de Hoog J, Worobiec A, Van Grieken R, Environmental science and technology 35, 4487 (2001). http://doi.org/10.1021/ES0155231
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES0155231
|
|
|
“Speciation of selected metals in aerosol samples by TXRF after sequential leaching”. Samek L, Ostachowicz B, Worobiec A, Spolnik Z, Van Grieken R, X-ray spectrometry 35, 226 (2006). http://doi.org/10.1002/XRS.905
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.905
|
|
|
“Thermal stability of beam sensitive atmospheric aerosol particles in electron probe microanalysis at liquid nitrogen temperature”. Worobiec A, de Hoog J, Osán J, Szalóki I, Ro C-U, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 58, 479 (2003). http://doi.org/10.1016/S0584-8547(03)00013-2
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(03)00013-2
|
|
|
“Unconventional microanalysis for low-Z, volatile and organic aerosol compounds”. Worobiec A, de Hoog J, Osán J, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 384 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“SnIV-containing layered double hydroxides as precursors for nano-sized ZnO/SnO2 photocatalysts”. Seftel EM, Popovici E, Mertens M, Stefaniak EA, Van Grieken R, Cool P, Vansant EF, Applied catalysis : B : environmental 84, 699 (2008). http://doi.org/10.1016/J.APCATB.2008.06.006
Abstract: Sn4+-containing LDH was prepared using the co-precipitation method at constant pH, and characterized using X-ray diffraction, UVvis diffuse reflectance spectroscopy and TG/DTG methods. The obtained product was further exposed to different thermal treatments in order to obtain nano-sized coupled ZnO/SnO2 systems with enhanced photocatalytic performances than the ones obtained by mixing the two semiconductor oxides. The formation of a well-defined ZnO/SnO2 system and the crystallite size, fully investigated using XRD, micro-Raman scattering and UVvis DR techniques, were found to be influenced by the nature of the precursors and the calcination temperature. The photocatalytic activity of the ZnO/SnO2 systems, evaluated for the photodegradation of methyl orange (MO) dye, was studied as a function of the initial pH, catalyst loading and the calcination temperature. The metal dispersion supplied by layered structures proved to be an advantage when preparing coupled ZnO/SnO2 systems, the photocatalytic activity being 2.3 times higher comparing with the physical mixtures performances. The maximum photocatalytic activity of the coupled ZnO/SnO2 system having a layered precursor was observed when using neutral pH, at a catalyst loading of 1 g/L calcined at 600 °C for 4 h.
Keywords: A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.APCATB.2008.06.006
|
|
|
“Determination of selenium in blood components by X-ray emission spectrometry”. Robberecht H, Deelstra H, Van Grieken R, Biological trace element research 25, 149 (1990). http://doi.org/10.1007/BF02990412
Abstract: Sampling, storing, sample pretreatment, and experimental conditions for selenium (Se) determination in human serum, plasma, and whole blood by X-ray emission spectrometric (XRS) methods are described. Concentration levels in these biological fluids, found by this technique, are discussed and compared to values found by other techniques for the same healthy population group in the same area. XRS analysis of blood from patients with various pathological conditions is reviewed, with special attention to the relation of Se with the concentration level of other essential or nonessential trace elements.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02990412
|
|
|
“Elemental composition of bottom-sediments from Pangani river basin, Tanzania : lithogenic and anthropogenic sources”. Hellar-Kihampa H, Potgieter-Vermaak S, van Meel K, Gatto Rotondo G, Kishimba M, Van Grieken R, Toxicological and environmental chemistry 94, 525 (2012). http://doi.org/10.1080/02772248.2011.648940
Abstract: River-bed sediments from the Pangani basin, Tanzania, were characterized for elemental compositions, following contamination risks from rapid expansions of human activities in the area. Samples were collected during two individual seasons and analyzed by high-polarizing beam energy dispersive X-ray fluorescence (EDXRF) for eight major and 14 trace elements. Evaluation of enrichment factors (EFs) was used to investigate the elemental flux and assess the contributions of natural and anthropogenic influences. The abundances of the major elements followed the order Si > Al > Fe > Ca > K > Ti > Mn > P, similar to that of the upper earth's crust, and were generally from the weathering of the bed-rock. The high concentrations of typical anthropogenic trace-elements (Cr < 160 mg kg−1, V < 85 mg kg−1, Ni < 60 mg kg−1, Cu < 87 mg kg−1, La < 90 mg kg−1) coupled with high EFs (>2) in some locations indicated contamination associated with agricultural and industrial activities. Factor analysis extracted five principal components that contributed to 96.0% of the total observed variance. The results indicated that river-bed sediments of the Pangani basin were influenced to a larger extent by lithogenic sources than anthropogenic impacts.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/02772248.2011.648940
|
|
|
“Losses of metabolically incorporated selenium in common digestion procedures for biological material”. Robberecht HJ, Van Grieken RE, Van den Bosch PA, Deelstra H, vanden Berghe D, Talanta : the international journal of pure and applied analytical chemistry 29, 1025 (1982). http://doi.org/10.1016/0039-9140(82)80244-0
Abstract: Two common procedures for wet destruction of biological materials for subsequent determination of selenium have been investigated. Rat organs and biological fluids were endogenously labelled with 75Se to monitor losses during the procedures. Addition of nitric and perchloric acids with gradual heating up to 210° seemed to be the best method: at this temperature the labelled selenium was still recovered quantitatively, and the destruction was fast and efficient.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(82)80244-0
|
|
|
“Metal pollution and selenium distributions in soils and grass near a non-ferrous plant”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, The science of the total environment 29, 229 (1983). http://doi.org/10.1016/0048-9697(83)90093-1
Abstract: Multi-element analysis results of direct energy-dispersive X-ray fluorescence of soil samples taken in the vicinity of a non-ferrous plant in Antwerp are reported. High concentrations of Pb, Cu, Zn, As and Se are found in nearby residential areas, especially in top-soil layers. Selenium pollution appears not to be leached significantly to lower soil horizons, but it is available for uptake by rye-grass, in which toxic levels are found. Results are compared to literature data. Hydride generation atomic absorption spectrometry proved to be unsuitable for direct analysis of the heavily contaminated soils.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(83)90093-1
|
|
|
“Percentage selenium in consumed belgian feeding”. Robberecht H, Deelstra H, vanden Berghe D, Van Grieken R, Revue des fermentations et des industries alimentaires 37, 188 (1982)
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Selenium in environmental and drinking waters of Belgium”. Robberecht H, Van Grieken R, van Sprundel M, vanden Berghe D, Deelstra H, The science of the total environment 26, 163 (1983). http://doi.org/10.1016/0048-9697(83)90109-2
Abstract: The tetravalent and hexavalent selenium content of water samples can be determined by conventional energy-dispersive X-ray fluorescence after different preconcentration steps. Selenium values of nearly three-hundred different environmental and drinking water samples in Belgium are reported. The results are quite low, ranging from the detection limits up to 1 μg l−1. The concentration levels are compared to literature data and the speciation is discussed. The contribution of drinking water to the daily intake of selenium in Belgium ranges from less than 0.2 to 5%.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(83)90109-2
|
|
|
“Selenium in the Belgian soils and its uptake by rye-grass”. Robberecht H, vanden Berghe D, Deelstra H, Van Grieken R, The science of the total environment 25, 61 (1982). http://doi.org/10.1016/0048-9697(82)90042-0
Abstract: Data obtained by atomic absorption spectroscopy showed a selenium concentration of only 0.11 ppm as an average value for the most representative agricultural soils in Belgium. The selenium content in rye-grass grown on different soil types was between 0.05 and 0.11 ppm, and positively correlated with the soil selenium level. Addition of selenium in the form of selenite to the different soil types resulted in an increased selenium uptake by the plant. The ultimate concentration in the plant depended on the structural and chemical composition of the soil. Twelve other elements were determined in the soils by energy-dispersive X-ray fluorescence; none showed a strong correlation with the soil selenium content or with the selenium uptake by ryegrass.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(82)90042-0
|
|
|
“Serum bromine levels in psoriasis”. Shani J, Barak S, Ram M, Levi D, Pfeifer Y, Schlesinger T, Avrach WW, Robberecht H, Van Grieken R, Pharmacology 25, 297 (1982). http://doi.org/10.1159/000137756
Abstract: Serum bromine levels in psoriatic Danes increased 2- to 3-fold during a 4-week bathing course in the Dead Sea. This increase correlated well with the improvement in their clinical and psychic condition. Serum bromine levels in psoriatic Danes were somewhat lower than those in healthy subjects residing in Denmark, but the difference was not significant. Israelis working in the open air in the Dead Sea area (air bromine 20-fold higher than in Jerusalem) had higher bromine levels than psoriatic or healthy Israelis residing in Jerusalem or healthy Israelis working in air-conditioned rooms in the Dead Sea area (p < 0.05), but those levels were still within the normal range. As our animal experimentation indicates that the skin is a major target organ for 82Br, applied either by bathing or as an aerosol, we conclude that the higher bromine levels noticed in the psoriatic Danes after their 4-week stay at the Dead Sea may be equally due to their contact with the bromine-containing aerosol and the high bromine level of the Dead Sea waters.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1159/000137756
|
|
|
“Correlation of serum aluminium values with tissue aluminium concentration”. de Broe ME, van de Vijver FL, Bekaert AB, d'Haese P, Paulus GJ, Visser WJ, Van Grieken R, de Wolff FA, Verbueken AH, Contributions to nephrology 38, 37 (1984)
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Patterns of iron storage in patients with severe renal failure”. van de Vijver FL, Vanheule AO, Verbueken AH, Van Grieken R, d'Haese P, Visser WJ, Bekaert AB, Buyssens N, de Broe ME, Contributions to nephrology 38, 153 (1984)
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Ultrastructural localization of aluminum in patients with dialysis-associated osteomalacia”. Verbueken AH, van de Vijver FL, Van Grieken RE, Paulus GJ, Visser WJ, d'Haese P, de Broe ME, Clinical chemistry : international journal of laboratory medicine and molecular diagnostics 30, 763 (1984)
Abstract: Using laser microprobe mass analysis, we studied the ultrastructural localization of aluminum in liver and bone tissue of chronic-hemodialysis patients with proven aluminum-induced osteomalacia. In the liver, aluminum was observed to be almost exclusively associated with iron. Detectable aluminum and large amounts of iron were found in lysosomes of both hepatocytes and Kupffer cells. In bone, aluminum was localized at the osteoid/calcified-bone interface and also was associated with iron in some cases.
Keywords: A1 Journal article; Pharmacology. Therapy; Pathophysiology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Atmospheric turbulence triggers pronounced diel pattern in karst carbonate geochemistry”. Roland M, Serrano-Ortiz P, Kowalski AS, Van Grieken R, Janssens IA, et al, Biogeosciences 10, 5009 (2013). http://doi.org/10.5194/BG-10-5009-2013
Abstract: CO2 exchange between terrestrial ecosystems and the atmosphere is key to understanding the feedbacks between climate change and the land surface. In regions with carbonaceous parent material, CO2 exchange patterns occur that cannot be explained by biological processes, such as disproportionate outgassing during the daytime or night-time CO2 uptake during periods when all vegetation is senescent. Neither of these phenomena can be attributed to carbonate weathering reactions, since their CO2 exchange rates are too small. Soil ventilation induced by high atmospheric turbulence is found to explain atypical CO2 exchange between carbonaceous systems and the atmosphere. However, by strongly altering subsurface CO2 concentrations, ventilation can be expected to influence carbonate weathering rates. By imposing ventilation-driven CO2 outgassing in a carbonate weathering model, we show here that carbonate geochemistry is accelerated and does play a surprisingly large role in the observed CO2 exchange pattern of a semi-arid ecosystem. We found that by rapidly depleting soil CO2 during the daytime, ventilation disturbs soil carbonate equilibria and therefore strongly magnifies daytime carbonate precipitation and associated CO2 production. At night, ventilation ceases and the depleted CO2 concentrations increase steadily. Dissolution of carbonate is now enhanced, which consumes CO2 and largely compensates for the enhanced daytime carbonate precipitation. This is why only a relatively small effect on global carbonate weathering rates is to be expected. On the short term, however, ventilation has a drastic effect on synoptic carbonate weathering rates, resulting in a pronounced diel pattern that exacerbates the non-biological behavior of soil-atmosphere CO2 exchanges in dry regions with carbonate soils.
Keywords: A1 Journal article; Plant and Ecosystems (PLECO) – Ecology in a time of change; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.5194/BG-10-5009-2013
|
|
|
“Chemical characterization of neo-ceramic powders by time-of-flight and Fourier transform laser microprobe mass spectrometry”. Struyf H, van Vaeck L, Kennis P, Gijbels R, van Grieken R, Rapid communications in mass spectrometry 10, 699 (1996). http://doi.org/10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
Abstract: Laser microprobe mass spectrometry (LMMS) aims at the identification of local organic and inorganic constituents at the surface of solids, The low mass resolution capabilities of the initially used time-of-flight (TOF) mass spectrometers have often proved to be insufficient for identification, Therefore, high mass resolution Fourier transform (ET) LMMS was developed, Neo-ceramic powders with oxide or carbide coatings were analyzed by both FT LMMS and TOF LMMS, The data are useful to compare the analytical information gained from both methods, Analytical results of these samples by electron microprobe x-ray analysis (EPXMA) and secondary ion mass spectrometry (SIMS) are discussed to assess the place of FT LMMS and TOF LMMS in the spectrum of microanalytical techniques.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.253
Times cited: 11
DOI: 10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|