|
“Spatial neutron flux distributions around A 14 MeV neutron generator”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 10, 95 (1972). http://doi.org/10.1007/BF02518771
Abstract: The neutron flux distribution in the vicinity of 30, 20 and 10 mm diameter targets is measured by irradiating concentric ring-type iron monitors at different distances from the target and counting the induced56Mn activity. Considering the many uncertainties, satisfactory agreement was found between theory and experiment.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02518771
|
|
|
“State-of-the-art X-ray fluorescence instrumentation for chemical analysis”. Margui E, Van Grieken R, Petro Industry News , 16 (2013)
Abstract: Nowadays, X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis (sometimes from Be to U) of a wide variety of samples. In particular, the truly multi-element character, acceptable speed and economy, ease of automation and the possibility to directly analyse solid samples are the most important features among the many that have made it a very mature analytical tool for routine quality controls in many industries, as well as for analytical support for the research laboratory.e recent technological advances, including the design of low-power micro-focus tubes and the novel X-ray optics and detectors have made it possible to extend XRF to the determination of low-Z elements and to obtain 2D or 3D information on a micrometre-scale. Furthermore, the recent development and commercialisation of benchtop and portable instrumentation, that offer extreme simplicity of operation in a low-cost design, have promoted even more the approach of XRF for many analytical problems.is article highlights this state-of-the art technique with regards to currently available XRF instrumentation on the market as well as recent applications in environmental and industrial fields.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Study of the Antarctic aerosol using X-ray fluorescence and single particle analysis”. Rojas CM, Van Grieken RE, Cantillano ME, Scientific series of the Chilean Antarctic Institute (Ser. Cinet. INACH) 42, 37 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Synthesis of a chelating cellulose filter with 2,2-diaminodiethylamine functional groups”. Smits J, Van Grieken R, Zeitschrift für angewandte Makromolekare Chemie 72, 105 (1978)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Total analysis of plant material and biological tissue by spark source mass spectrometry”. Verbueken A, Michiels E, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 300 (1981). http://doi.org/10.1007/BF00488606
Abstract: Analysis of biological material by spark source mass spectrometry is reported. Preliminary studies mainly based upon the analysis of the NBS standard reference material SRM-1571 (Orchard Leaves) are described. Attention is drawn to the importance of a suitable sample preparation method. The advantages of a wet digestion technique in a Teflon bomb are discussed and its use is justified by the satisfactory overall analysis precision of about 20%.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00488606
|
|
|
“Trace elements and individual particle analysis of atmospheric aerosols from the Antarctic peninsula”. Artaxo P, Rabello MLC, Maenhaut W, Van Grieken R, Tellus 44b, 318 (1992)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace elements in the atmospheric aerosols and soils in and around Recife, N.E. Brasil”. Costa Dantas C, Moura de Amorim W, Van 't dack L, Van Grieken R, Ciencia e cultura 32, 1525 (1980)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace metal analysis of sediments and particulate matter in sea water by energy-dispersive X-ray fluorescence”. Vanderstappen M, Van Grieken R, Fresenius' Zeitschrift für analytische Chemie 282, 25 (1976). http://doi.org/10.1007/BF00443774
Abstract: The capability of energy-dispersive X-ray fluorescence was investigated for fast and simple chemical analysis of trace elements in sediments and particulate matter in sea water. Nuclepore 0.4 μm pore-size membranes are recommended as optimal filters for a straightforward collection of suspended material. The collection of suspended trace metals by filtration seemed to give a sufficiently homogeneous filter load (s% <2.5). Data are presented on the concentrations of K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Rb and Sr with a fair precision (s% < 5.6) and accuracy.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00443774
|
|
|
“O vlijanii kolitsjestva osadkov na kontsentratsioe elementov i ionov v tsjastitsach gorodskogo aerozolja”. Deutsch F, Stranger M, Kaplinskii AE, Samek L, Joos P, Van Grieken R, Optika atmospheri i okeana 16, 927 (2003)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Weathering of treated and untreated limestones in atmospheric exposures”. Vleugels GJ, Van Grieken RE, Journal of preservation technology 23, 48 (1991)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Zware metalen in Noordzee- en Schelde-sedimenten”. Van Alsenoy W, Bernard P, Van Grieken R, Wtare 5, 113 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Young Anthony van Dyck revisited : a multidisciplinary approach to a portrait once attributed to Peter Paul Rubens”. Van der Stighelen K, Janssens K, van der Snickt G, Alfeld M, Van Beneden B, Demarsin B, Proesmans M, Marchal G, Dik J, Art matters : international journal for technical art history 6, 21 (2014)
Abstract: Part of the collection of the Rubens House in Antwerp is a portrait of young Anthony van Dyck, alternatively attributed to Peter Paul Rubens and his pupil Anthony van Dyck. In order to reconstruct the genesis of the portrait in a manner that improves upon past investigations, a number of high-end technological methods, such as X-radiography, X-ray computer tomography, mammographic tomosynthesis and macroscopic X-ray fluorescence, have been employed to render the overpainted layers visible again. The results of the interdisciplinary examinations of the portrait of the youthful Van Dyck are impressive. The combined results allow the later additions to be peeled away until the original composition can be reached. Several pentimenti are easily discernible and refer to a rather immature hand that makes the authorship of Peter Paul Rubens very unlikely. What emerges is a portrait of an ambitious young man with a luxuriant head of hair and a slightly turned-up collar. The hat and cape were added later. The facial features are more recognisable and the execution of the bold curls points irrefutably in the direction of Anthony van Dyck as the author of his own portrait.
Keywords: A3 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Les conclusions du programme européen Vidrio sur la protection des vitraux par verrière extérieure”. Pallot-Frossard I, Van Grieken R, Godoi R, Kontozova V, et al, Monumental: revue scientifique et technique , 113 (2007)
Keywords: A3 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental composition of PM2.5 in Araraquara City (Southeast Brazil) during seasons with and without sugar cane burning”. Silva FS, Godoi RHM, Tauler R, de André, PA, Saldiva PHN, Van Grieken R, de Marchi MRR, Journal of environmental protection 6, 426 (2015). http://doi.org/10.4236/JEP.2015.65041
Abstract: Particulate matter with an aerodynamic diameter below 2.5 μm (PM2.5), present in polluted air, has been associated with a large spectrum of health impairments, mainly because of its deep deposition into the lungs. Araraquara City (Southeast Brazil) is surrounded by sugar-cane plantations, which are burned to facilitate the harvesting; this process causes environmental pollution due to the large amounts of soot that are released into the atmosphere. In this work, the elemental composition of PM2.5 was studied in two scenarios, namely in sugar-cane harvesting (HV) and in non-harvesting (NHV) seasons. The sampling strategy included one campaign in each season. PM2.5 was collected using a dichotomous sampler (10 L·min-1, 24 h) with PTFE filters. Information concerning the bulk elemental concentration was provided by energy-dispersive X-ray fluorescence. Enrichment factor analysis indicated that S, Cl, K, Cr, Ni, Cu, Zn, As, Cd and Pb were highly enriched relative to their crustal ratios (to Al). Principal component analysis was used to get some insight about the sources of the elements. Principal component 1 (PC1) explained 30.5% of data variance. The elements that had high loading (>0.7) were: S, Cr, As, and Pb; these are associated with combustion of fossil fuels. In principal component 2 (PC2), Cl, Cu, Zn, and Cd showed high loadings; these elements are associated with biomass burning. The Ni concentration found is three times larger than the threshold of risk for lung cancer, as recommended by the World Health Organization.
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.4236/JEP.2015.65041
|
|
|
“Fijn stof en pollutiegassen in de binnenlucht”. Van Grieken R, Stranger M, ARGUS milieumagazine 4, 18 (2006)
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Gevolgen van luchtverontreiniging op historische gebouwen”. Roekens E, Van Grieken R, Ons erfdeel 30, 361 (1987)
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Die risikoprofiel van Pb en Cr in stedelike padstof”. Potgieter-Vermaak S, Van Grieken R, Potgieter H, Litnet akademies : 'n joernaal vir die geesteswetenskappe 9, 1 (2012)
Abstract: The risk profile of Cr and Pb in urban road deposited sediment Exponential urbanisation and industrial growth occur on a global scale and result in an ecological burden, of which one important part is pollution. It is well known that the extent of air pollution has escalated over the past two decades in several parts of the world, despite mitigating measures and legislation. Current research points to the fact that air pollution in urban and industrial areas is substantially different from that found in rural areas. Road dust (RD) contributes up to 35% of airborne particulate matter due to resuspension thereof, and poses a health concern due to carcinogenic and toxic components potentially present in the micron-sized fractions. Although literature does report on the concentrations of trace, toxic metals and metalloids present in RD (Hooker and Nathanail 2006), the molecular make-up of particulates generated due to the resuspension of the RD is not well documented. In vitro and animal toxicological studies have confirmed that the chemical composition of inhaled particles plays a major role in its toxic, genotoxic and carcinogenic mechanisms, but the component-specific toxic effects are still not understood. Transition metals binding to air particle matter can result in reactive oxygen species in the human body (particularly in the lungs), and this is a significant risk, especially for vulnerable population groups like elderly people, children and terminally ill patients. The characterisation of the molecular composition of the fine fraction is evidently of importance for public health. During an earlier study, road dust from an inner-city environment in the UK was collected and partially characterised (Barrett e.a. 2010). These same-size fractions were analysed for their elemental concentrations, using X-ray Fluorescence Spectrometry (XRFS) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In addition, single-particle analysis was performed on the different fractions by means of Computer Controlled Electron Probe X-ray Micro Analysis (CC-EPXMA) and their molecular structure probed by studying elemental associations. These findings were correlated with Micro Raman Spectroscopy (MRS) results. It was found that the fine fraction (<38 μm) had the highest Pb (238 ppm) and Cr (171 ppm) concentrations. The CC-EPXMA data showed >50% association of Cr-rich particles with Pb and the MRS data showed that the Cr was mostly present as lead chromate and therefore in the Cr(VI) oxidation state. Concentrations of both Pb and Cr decreased substantially (279 (<38 mm) 13 ppm (<1mm); 171 (<38 mm) 91 ppm (<1mm) respectively) in the larger fractions. Apart from rather alarmingly high concentrations of oxidative stressors (Cu, Fe, Mn), the carcinogenic and toxic potential of the inhalable fraction is evident. Preliminary bioaccessibility data indicated that both Cr and Pb are readily
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Einfluss verschiedener Silbersalze auf die Farbintensität von Silbergelb : analytische Untersuchungen”. De Vis K, Jembrih-Simbürger D, Schalm O, Schreiner M, Caen J, Zeitschrift für Kunsttechnologie und Konservierung 16, 147 (2002)
Keywords: A2 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of micro computed tomography images, a look inside historic enamelled metal objects”. van der Linden V, Van de Casteele E, Thomas MS, de Vos A, Janssen E, Janssens K, Applied physics A : materials science &, processing 98, 385 (2010). http://doi.org/10.1007/S00339-009-5394-9
Abstract: In this study the usefulness of micro-Computed Tomography (µ-CT) for the in-depth analysis of enamelled metal objects was tested. Usually investigations of enamelled metal artefacts are restricted to non-destructive surface analysis or analysis of cross sections after destructive sampling. Radiography, a commonly used technique in the field of cultural heritage studies, is limited to providing two-dimensional information about a three-dimensional object (Lang and Middleton, Radiography of Cultural Material, pp. 6061, Elsevier-Butterworth-Heinemann, Amsterdam-Stoneham-London, 2005). Obtaining virtual slices and information about the internal structure of these objects was made possible by CT analysis. With this technique the underlying metal work was studied without removing the decorative enamel layer. Moreover visible defects such as cracks were measured in both width and depth and as of yet invisible defects and weaker areas are visualised. All these features are of great interest to restorers and conservators as they allow a view inside these objects without so much as touching them.
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.455
Times cited: 3
DOI: 10.1007/S00339-009-5394-9
|
|
|
“Investigating morphological changes in treated vs. untreated stone building materials by x-ray micro-CT”. Bugani S, Camaiti M, Morselli L, Van de Casteele E, Janssens K, Analytical and bioanalytical chemistry 391, 1343 (2008). http://doi.org/10.1007/S00216-008-1946-7
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.431
Times cited: 25
DOI: 10.1007/S00216-008-1946-7
|
|
|
“Investigation on porosity changes of Lecce stone due to conservation treatments by means of x-ray nano- and improved micro-computed tomography: preliminary results”. Bugani S, Camaiti M, Morselli L, Van de Casteele E, Janssens K, X-ray spectrometry 36, 316 (2007). http://doi.org/10.1002/XRS.976
Keywords: A1 Journal article; Vision lab; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 28
DOI: 10.1002/XRS.976
|
|
|
“Occupational allergic contact dermatitis from bisphenol A in vinyl gloves”. Matthieu L, Godoi AFL, Lambert J, Van Grieken R, Contact dermatitis 49, 281 (2003). http://doi.org/10.1111/J.0105-1873.2003.0241.X
Abstract: Allergic contact dermatitis caused by polyvinyl chloride gloves is rarely reported, and in only 2 cases was bisphenol A considered to be the responsible sensitizer. We report a patient with occupational hand dermatitis after the use of a new type of high-density vinyl (HDV) gloves. Patch tests showed positive (++) reactions to both used and new HDV gloves and to bisphenol A. Chemical analysis by gas chromatography-mass spectrometry demonstrated the presence of bisphenol A in the HDV gloves. Replacement by nitrile rubber gloves resulted in complete clearance of the hand dermatitis.
Keywords: A1 Journal article; Translational Pathophysiological Research (TPR); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.0105-1873.2003.0241.X
|
|
|
“Organohalogenated pollutants in human serum from Iassy, Romania and their relation with age and gender”. Dirtu AC, Cernat R, Dragan D, Mocanu R, Van Grieken R, Neels H, Covaci A, Environment international 32, 797 (2006). http://doi.org/10.1016/J.ENVINT.2006.04.002
Keywords: A1 Journal article; Toxicological Centre; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ENVINT.2006.04.002
|
|
|
“Chemical characterization of neo-ceramic powders by time-of-flight and Fourier transform laser microprobe mass spectrometry”. Struyf H, van Vaeck L, Kennis P, Gijbels R, van Grieken R, Rapid communications in mass spectrometry 10, 699 (1996). http://doi.org/10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
Abstract: Laser microprobe mass spectrometry (LMMS) aims at the identification of local organic and inorganic constituents at the surface of solids, The low mass resolution capabilities of the initially used time-of-flight (TOF) mass spectrometers have often proved to be insufficient for identification, Therefore, high mass resolution Fourier transform (ET) LMMS was developed, Neo-ceramic powders with oxide or carbide coatings were analyzed by both FT LMMS and TOF LMMS, The data are useful to compare the analytical information gained from both methods, Analytical results of these samples by electron microprobe x-ray analysis (EPXMA) and secondary ion mass spectrometry (SIMS) are discussed to assess the place of FT LMMS and TOF LMMS in the spectrum of microanalytical techniques.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.253
Times cited: 11
DOI: 10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Equilibrium constants for trace elements in natural waters”. Van 't dack L, Blommaert W, Vandelannoote R, Gijbels R, van Grieken R, Reviews in analytical chemistry 7, 297 (1983)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Hydrogeochemistry in the zinclead mining district of Les Malines (Gard, France)”. Bosch B, Leleu M, Oustrière P, Sarcia C, Sureau JF, Blommaert W, Gijbels R, Sadurski A, Vandelannoote R, Van Grieken R, Van 'T Dack L;, Chemical geology 55, 31 (1986). http://doi.org/10.1016/0009-2541(86)90125-7
Abstract: Sensitive multi-element analysis techniques together with major-element and isotopic analyses were applied to spring, mine and surface waters in the vicinity of an important known zinclead deposit in a carbonate environment, in the Les Malines area (Gard, France). Both the dissolved and suspended phases were investigated, and concretions and sediments were also considered in some cases. This methodological test shows that the ore body leaves various clear fingerprints, such as the Zn, As, Sb, Pb and U levels in the dissolved phase, the sulfate increment and the δ 34S. Some of the elements in solution are controlled by slightly soluble compounds, e.g. Zn by smithsonite and hydrozincite, Ba by barite, and Pb by hydrocerussite. Mapping the saturation indices for these elements appears useful for displaying the hydrogeochemical anomaly.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.524
Times cited: 3
DOI: 10.1016/0009-2541(86)90125-7
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
|
|
“Laser microprobe mass spectrometry in biology and biomedicine”. Eeckhaoudt S, van Vaeck L, Gijbels R, van Grieken RE, Scanning microscopy S8, 335 (1994)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|