“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
“Enhancement of X-ray fluorescence intensity from an ultra-thin sandwiched layer at grazing-emission angles”. Tsuji K, Takenaka H, Wagatsuma K, de Bokx PK, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1881 (1999). http://doi.org/10.1016/S0584-8547(99)00143-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00143-3
|
“Enrichment of trace anions from water with 2,2'-diaminodiethylamine cellulose filters”. Smits J, Van Grieken R, Analytica chimica acta 123, 9 (1981). http://doi.org/10.1016/S0003-2670(01)83152-4
Abstract: Cellulose filters with immobilized 2,2'-diaminodiethylamine (DEN) functional groups are studied for trace anion preconcentration from aqueous solution, with subsequent x-ray fluorescence measurements. For most oxoanions with a central metal atom, nearly quantitative collection can be achieved by 10-cm2 DEN filters under the following optimized conditions: pH 36, filtration rate up to 0.5 ml cm-2 min-1, and sample volume up to 100 ml cm-2. The collection yield is independent of the trace oxoanion concentration up to at least 1.5 μmol cm-2. Although the DEN filter exhibits some selectivity towards oxoanions with a central metal atom, ionic strength affects the results; the collection efficiency is strongly depressed with salt (e.g. NaCl) concentrations above 0.01 M. The applicability of the DEN filter in anion collection is therefore limited to dilute solutions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)83152-4
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Environmental conditions controlling the chemical weathering of the Madara Horseman monument, NE Bulgaria”. Delalieux F, Cardell C, Todorov V, Dekov V, Van Grieken R, Journal of cultural heritage 2, 43 (2001)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Environmental monitoring in four European museums”. Camuffo D, Van Grieken R, Busse H-J, Sturaro G, Valentino A, Bernardi A, Blades N, Shooter D, Gysels K, Deutsch F, Wieser M, Kim O, Ulrych U, Atmospheric environment : an international journal 35, S127 (2001)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
“Evaluation of multi-element analysis of blood serum by energy-dispersive x-ray spectrometry”. Robberecht H, Van Grieken R, Shani J, Barak S, Analytica chimica acta 136, 285 (1982). http://doi.org/10.1016/S0003-2670(01)95388-7
Abstract: Conventional energy-dispersive x-ray fluorescence is applied in the analysis of blood serum to give the concentrations of 710 elements simultaneously with minimal manipulation of the samples. Simple spotting onto a Mylar carrier of 250 μl of serum, doped with two internal standards, was chosen as the sample preparation step. Some 200 serum samples, analyzed in replicate (n = 26), were used to evaluate this procedure. The detection limits are 4 μg ml-1 for K and Ca, 0.50.2 μg ml-1 for Fe, Cu, Pb and Zn, and less than 0.1 μg ml-1 for Se, Rb and Sr. Well above these limits, the standard deviation is around 10%. Comparison with the results of other measurements on the same samples indicates an accuracy of that order. The simplicity and high throughput, and the possibility of automating the x.r.f. measurements, make the proposed procedure suitable for screening large numbers of sera.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95388-7
|
“Evaluation of secondary cathodes for glow discharge mass spectrometry analysis of different nonconducting sample types”. Schelles W, de Gendt S, Müller V, Van Grieken R, Applied spectroscopy 49, 939 (1995). http://doi.org/10.1366/0003702953964741
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702953964741
|
“An expert system for chemical speciation of individual particles using low-Z particle electron probe X-ray microanalysis data”. Ro C-U, Kim HK, Van Grieken R, Analytical chemistry 76, 1322 (2004). http://doi.org/10.1021/AC035149I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC035149I
|
“Extraction of environmental information from large aerosol data sets through combined application of cluster and factor analysis”. de Bock LA, Treiger B, van der Auwera L, Van Grieken RE, Microchimica acta 128, 191 (1998). http://doi.org/10.1007/BF01243049
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01243049
|
“Fast chromatographic determination of polycyclic aromatic hydrocarbons in aerosol samples from sugar cane burning”. Godoi AFL, Ravindra K, Godoi RHM, Andrade SJ, Santiago-Silva M, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 49 (2004). http://doi.org/10.1016/J.CHROMA.2003.10.048
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.10.048
|
“Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent”. György K, Ajtony Z, van Meel K, Van Grieken R, Czitrovszky A, Bencs L, Talanta : the international journal of pure and applied analytical chemistry 85, 1253 (2011). http://doi.org/10.1016/J.TALANTA.2011.05.028
Abstract: A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO3) and bismuth tellurite (Bi2TeO5) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl4) was dispensed with a conventional autosampler into the graphite tube. The CCl4 was partially dried at 80 °C under the mini-flow (40 cm3 min−1) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 19002100 °C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100 °C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L−1 for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L−1 were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol−1 Er and 11 μmol mol−1 Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2011.05.028
|
“Ferrihydrite precipitation in groundwater-fed river systems (Nete and Demer river basins, Belgium) : insights from a combined Fe-Zn-Sr-Nd-Pb-isotope study”. Dekov VM, Vanlierde E, Billström K, Gatto Rotondo G, van Meel K, Darchuk L, Van Grieken R, et al, Chemical geology 386, 1 (2014). http://doi.org/10.1016/J.CHEMGEO.2014.07.023
Abstract: Two groundwater-fed river systems (Nete and Demer, Belgium) carry red suspended material that settles on the river bed forming red sediments. The local aquifer that feeds these river systems is a glauconite-rich sand, which provides most of the dissolved Fe to the rivers. The solid component of these systems, i.e., the red suspended material and sediments, has a simple mineralogy (predominantly ferrihydrite), but shows a complex geochemistry pointing out the different processes contributing to the river chemistry: (1) the red sediments have higher transition metal (excluding Cu) and detrital element (e.g., Si, Al, K, Rb, etc.) concentrations than the red suspended matter because of their longer residence time in the river and higher contribution of the background (aquifer) component, respectively; (2) the red suspended material and sediments have inherited their rare earth element (REE) patterns from the aquifer; (3) the origin of Sr present in the red suspended matter and red sediments is predominantly marine (i.e., Quaternary calcareous rocks), but a small amount is geogenic (i.e., from detrital rocks); (4) Pb in both solids originates mostly from anthropogenic and geogenic sources; (5) all of the anthropogenic Pb in the red suspended material and sediments is hosted by the ferrihydrite; (6) Nd budget of the red riverine samples is controlled by the geogenic source and shows little anthropogenic component; (7) the significant Fe- and Zn-isotope fractionations are in line with the previous studies. Their fractionation patterns do not correlate, suggesting that the processes controlling the isotope geochemistry of Fe and Zn are different: oxidation/reduction most likely governs the Fe-isotope fractionation, whereas adsorption/desorption or admixing of anthropogenic sources controls the isotope fractionation of Zn.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHEMGEO.2014.07.023
|
“Field evaluation of a wind tunnel-impactor system for sampling ambient aerosols”. Gysels K, Van Grieken R, Journal of aerosol science 30, 639 (1999). http://doi.org/10.1016/S0021-8502(98)00747-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0021-8502(98)00747-2
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
“Geochemical assessment of a subtropical reservoir : a case study in Curitiba, Southern Brazil”. Godoi RHM, Hirata PY, Bitterncourt AVL, Godoi AFL, Potgieter-Vermaak S, Gatto Rotondo G, Van Grieken R, et al, Clean : soil, air, water 40, 364 (2012). http://doi.org/10.1002/CLEN.201000610
Abstract: Suspended particles and dissolved substances in water provide reactive surfaces, influence metabolic activity and contribute to the net sediment deposition. It therefore plays an important part in the ecology and quality of the water mass. The water quality in reservoirs is crucial and it is naturally maintained by flushing and sedimentation, which continuously remove phosphorus from the water. In some reservoirs, however, these removal processes are countered by recycling of ions which could play a key role to start and/or maintain the eutrophic state. The combination of macro-, trace- and microanalysis techniques can be useful to trace pollution sources through a chemical fingerprint, whether be during an acute environmental disaster or a long-term release of pollutants. The water quality and total metal content of reservoir sediments were assessed in a reservoir, situated in the capital of the Paraná State, in the South-Eastern part of Brazil. The goal of this paper was to determine the metal presence in the sediment and metal and ionic speciation in the Green River reservoir water. Water and bed sediment samples, collected from various sites during 2008 and 2009, were investigated using XRF, ICP-OES, ICP-MS, XRD and zeta potential measurements. Based on the results, the heavy metal concentration and chemical composition of the suspended matter in the water samples, as well as the sediment's chemical composition will be discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/CLEN.201000610
|
“Geochemical characterization of recent sediments in the Baltic Sea by bulk and electron microprobe analysis”. Belmans F, Van Grieken R, Brügmann L, Marine chemistry 42, 223 (1993). http://doi.org/10.1016/0304-4203(93)90014-F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(93)90014-F
|
“Geochemistry of suspended matter from the baltic sea : 1 : results of individual particle characterization by automated electron microprobe”. Bernard PC, Van Grieken RE, Brügmann L, Marine chemistry 26, 155 (1989). http://doi.org/10.1016/0304-4203(89)90058-3
Abstract: Automated electron probe X-ray microanalysis was used to characterize some 15 000 individual suspension particles from 50 samples of suspended matter collected from different depths at 18 stations throughout the Baltic Sea and the transient area to the North Sea. For each particle, 14 minor and major elements were determined and size information data were obtained. To process this huge amount of results, multivariate analysis techniques were invoked: the particles were classified into specific types and the abundance variations of these groups were studied. It appeared that 80% of all investigated particles contained mostly silicon, and seemed to consist of quartz, and K-rich and Fe-rich aluminosilicates. The abundance of BaSO4 particles averaged 5% throughout the Baltic Sea, but amounted to up to 44% at some stations. The abundance of the Fe-rich particles varied significantly with location and depth, and averaged ∼ 4%. They were often found to be associated with significant amounts of P. Both of these particle types and the Mn-rich particles are thought to be mainly authigenic. Calcium carbonate particles are more abundant towards the North Sea (which seems to act as a source). Principal component analysis of the data revealed that most of the compositional variability can be explained by differences between deep and surface waters and by the influences of inflowing North Sea waters. Additional information about the types and sources of the suspended matter in the Baltic Sea was gained from the comparison and correlation of the single particle results with different fractions of the bulk concentrations of elements such as Al, Ca, Mn, Fe, Zn and Ba.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(89)90058-3
|
“Geochemistry of suspended matter from the Baltic Sea: 2: results of bulk trace metal analysis by AAS”. Brügmann L, Bernard PC, Van Grieken R, Marine chemistry 38, 303 (1992). http://doi.org/10.1016/0304-4203(92)90039-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(92)90039-D
|
“Geophysical applicability of aerosol size distribution measurements using cascade impactors and proton-induced X-ray-emission”. Van Grieken RE, Johansson TB, Akselsson KR, Winchester JW, Nelson JW, Chapman KR, Atmospheric environment : an international journal 10, 571 (1976). http://doi.org/10.1016/0004-6981(76)90040-8
Abstract: Proton Induced X-ray Emission, (PIXE), is capable of high precision analysis for trace element components of aerosol particle size fractions sampled by cascade impactor. A statistical evaluation of data quality has been carried out in order to distinguish between analytical uncertainties in the PIXE procedure, errors caused by cascade impactor performance and by other factors in the sampling procedure, and geophysical causes of differences in composition and particle size distributions of the elements in aerosols. Replicate analyses and simultaneous samplings taken in north Florida and St. Louis have been used for the data evaluation. In addition to the analytical error the sampling procedure contributes an error of ~ 10% to be added quadratically. The resulting precision is sufficient to evaluate the data in geophysical terms. This is illustrated by means of sample sets taken simultaneously in an urban, forest and coastal environment of the same region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(76)90040-8
|
“Grazing-emission electron probe microanalysis of particles near the substrate edge”. Bekshaev A, de Hoog J, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 56, 2385 (2001). http://doi.org/10.1016/S0584-8547(01)00300-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00300-7
|
“Grazing exit electron probe microanalysis for surface and particle analysis”. Tsuji K, Wagatsuma K, Nullens R, Van Grieken RE, Analytical chemistry 71, 2497 (1999). http://doi.org/10.1021/AC990075P
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990075P
|
“Grazing-exit electron probe x-ray microanalysis of light elements in particles”. Spolnik Z, Tsuji K, Van Grieken R, X-ray spectrometry 33, 16 (2004). http://doi.org/10.1002/XRS.656
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.656
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
“Health implications of atmospheric aerosols from asbestos-bearing road pavements traditionally used in Southern Brazil”. Godoi RHM, Goncalves SJ Jr, Sayama C, Polezer G, Reis Neto JM, Alfoldy B, Van Grieken R, Riedi CA, Yamamoto CI, Godoi AFL, Bencs L, Environmental Science and Pollution Research
T2 –, 1st International Caparica Conference on Pollutant Toxic Ions and, Molecules (PTIM), 2015, Caparica, PORTUGAL 23, 25180 (2016). http://doi.org/10.1007/S11356-016-7586-0
Abstract: Serpentine and amphibole asbestos occur naturally in certain geologic settings worldwide, most commonly in association with ultramafic rocks, along associated faults. Ultramafic rocks have been used in Pin County, Southern Brazil for decades for the purpose of road paving in rural and urban areas, but without the awareness of their adverse environmental and health impact. The aim of this study was the chemical characterization of aerosols re-suspended in two rural roads of Pin, paved with ultramafic rocks and to estimate the pulmonary deposition of asbestos aerosols. Bulk aerosol samples were analyzed by means of X-ray fluorescence spectrometry and X-ray diffraction analysis, in order to characterize elemental composition and crystallinity. Single-particle compositions of aerosols were analyzed by computer-controlled electron-probe microanalysis, indicating the presence of a few percentages of serpentine and amphibole. Given the chemical composition and size distribution of aerosol particles, the deposition efficiency of chrysotile, a sub-group of serpentine, in two principal segments of the human respiratory system was estimated using a lung deposition model. As an important finding, almost half of the inhaled particles were calculated to be deposited in the respiratory system. Asbestos depositions were significant (similar to 25 %) in the lower airways, even though the selected breathing conditions (rest situation, nose breathing) implied the lowest rate of respiratory deposition. Considering the fraction of inhalable suspended chrysotile near local roads, and the long-term exposure of humans to these aerosols, chrysotile may represent a hazard, regarding more frequent development of lung cancer in the population of the exposed region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11356-016-7586-0
|
“Heavy metal contamination in sediments from the Belgian coast and Scheldt estuary”. Araújo MFD, Bernard PC, Van Grieken RE, Marine pollution bulletin 19, 269 (1988). http://doi.org/10.1016/0025-326X(88)90597-8
Abstract: Sixty-two samples of total sediments and the separated clay/silt size fractions were analysed by energy-dispersive X-ray fluorescence spectrometry to evaluate the pollution level and the trends in samples collected along the Belgian coast over a period of 6 yr and at four stations located in the Scheldt estuary where two of these were sampled periodically for 4 yr. Three correction methods for grain size effects were applied, either to the bulk sediment samples or to the clay/silt size fractions, and the results were compared. Local variations on the concentrations in some of the elements determined were used to establish whether they result from an anthropogenic or natural origin. The level of pollution was assessed as a function of the location, sampling date, and depth.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0025-326X(88)90597-8
|
“Heavy metal distribution in sediments of Krishna River basin, India”. Ramesh R, Subramanian V, Van Grieken R, Environmental geology and water sciences 15, 207 (1990)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Heavy metal distribution in the Godavari river basin”. Biksham G, Subramanian V, Ramanathan A, Van Grieken R, Environmental geology and water sciences 17, 117 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Heavy metals distribution in the sediments of Ganges and Brahmaputra rivers”. Subramanian V, Van Grieken R, Van 't dack L, Environmental geology 9, 93 (1987). http://doi.org/10.1007/BF02449940
Abstract: Bed sediments were collected from the entire region of the Ganges basin and some parts of the Brahmaputra. In addition, selected stations were sampled for suspended sediments as well. The samples were analysed for a number of heavy metals (Fe, Mn, Ni, Cr, Cu, and Zn) by the thin-film energy dispersive X-ray fluorescence technique. There are pronounced temporal and spatial variations in the heavy metals distributions. Suspended sediments are 510 times richer than the bed sediments. None of the tributaries contribute significant heavy metal load, but around urban areas in Yamuna (tributary of Ganges), very high levels due to the distribution from the drainage network are observed. Compared to the Brahmaputra, the distribution and fractionation of heavy metals in the Ganges sediments are more erratic and highly variable. All the metals considered show high correlation among themselves. Given the high flux of suspended sediments from the Himalayan rivers (nearly 20% of the global flux), the worldwide budget for heavy metal transport may need to be suitably revised.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02449940
|