“Determination of the cd-bearing phases in municipal solid waste and Biomass single fly ash particles using SR-mu XRF Spectroscopy”. Camerani MC, Somogyi A, Vekemans B, Ansell S, Simionovici AS, Steenari B-M, Panas I, Analytical chemistry 79, 6496 (2007). http://doi.org/10.1021/AC070206J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070206J
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
“Direct current glow discharge mass spectrometry for elemental characterization of polymers”. Schelles W, Van Grieken R, Analytical chemistry 69, 2931 (1997). http://doi.org/10.1021/AC970186T
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC970186T
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
“Electrocatalytic oxidation of water by OH- –, and H₂O-capped IrOx nanoparticles electrophoretically deposited on graphite and basal plane HOPG : effect of the substrate electrode”. Mirbagheri N, Campos R, Ferapontova EE, Chemelectrochem 8, 1632 (2021). http://doi.org/10.1002/CELC.202100317
Abstract: Iridium oxide (IrOx) is one of the most efficient electrocatalysts for water oxidation reaction (WOR). Here, WOR electrocatalysis by 1.6 nm IrOx nanoparticles (NPs) electrophoretically deposited onto spectroscopic graphite (Gr) and basal plane highly ordered pyrolytic graphite (HOPG) was studied as a function of NPs' capping ligands and electrodeposition substrate. On Gr, OH-- and H2O-capped NPs exhibited close sub-monolayer surface coverages and specific electrocatalytic activity of 18.9-23.5 mA nmol(-1) of Ir-IV/V sites, at 1 V and pH 7. On HOPG, OH--capped NPs produced films with a diminished WOR activity of 5.17 +/- 2.40 mA nmol(-1). Electro-wettability-induced changes impeded electrophoretic deposition of H2O-capped NPs on HOPG, WOR currents being 25-fold lower than observed for OH--capped ones. The electrocatalysis efficiency correlated with hydrophilic properties of the substrate electrodes, affecting morphological and as a result catalytic properties of the formed IrOx films. These results, important both for studied and related carbon nanomaterials systems, allow fine-tuning of electrocatalysis by a proper choice of the substrate electrode.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.136
DOI: 10.1002/CELC.202100317
|
“Electrochemical fingerprints of illicit drugs on graphene and multi-walled carbon nanotubes”. Dragan A-M, Truta FM, Tertis M, Florea A, Schram J, Cernat A, Feier B, De Wael K, Cristea C, Oprean R, Frontiers In Chemistry 9, 641147 (2021). http://doi.org/10.3389/FCHEM.2021.641147
Abstract: Illicit drugs use and abuse remains an increasing challenge for worldwide authorities and, therefore, it is important to have accurate methods to detect them in seized samples, biological fluids and wastewaters. They are recently classified as the latest group of emerging pollutants as their consumption increased tremendously in recent years. Nanomaterials have gained much attention over the last decade in the development of sensors for a myriad of applications. The applicability of these nanomaterials, functionalized or not, significantly increases and it is therefore highly suitable for use in the detection of illicit drugs. We have assessed the suitability of various nanoplatforms, such as graphene (GPH), multi-walled carbon nanotubes (MWCNTs), gold nanoparticles (AuNPs) and platinum nanoparticles (PtNPs) for the electrochemical detection of illicit drugs. GPH and MWCNTs were chosen as the most suitable platforms and cocaine, 3,4-methylendioxymethamfetamine (MDMA), 3-methylmethcathinone (MMC) and alpha-pyrrolidinovalerophenone (PVP) were tested. Due to the hydrophobicity of the nanomaterials-based platforms which led to low signals, two strategies were followed namely, pretreatment of the electrodes in sulfuric acid by cyclic voltammetry and addition of Tween 20 to the detection buffer. Both strategies led to an increase in the oxidation signal of illicit drugs. Binary mixtures of illicit drugs with common adulterants found in street samples were also investigated. The proposed strategies allowed the sensitive detection of illicit drugs in the presence of most adulterants. The suitability of the proposed sensors for the detection of illicit drugs in spiked wastewaters was finally assessed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.994
DOI: 10.3389/FCHEM.2021.641147
|
“Elemental and single particle aerosol characterisation at a background station in Kazakhstan”. Hoornaert S, Godoi RHM, Van Grieken R, Journal of atmospheric chemistry 48, 301 (2004). http://doi.org/10.1023/B:JOCH.0000044432.74476.B0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/B:JOCH.0000044432.74476.B0
|
“The elemental chemistry of sediments in the Krishna River basin, India”. Ramesh R, Subramanian V, Van Grieken R, Van 't dack L, Chemical geology 74, 331 (1989). http://doi.org/10.1016/0009-2541(89)90042-9
Abstract: Composition of bed, core and suspended sediments collected from Krishna River sediments were studied and the observations are discussed in the light of other Indian rivers, world's average river suspended particles, surficial rock and soils. The contents of V, Cr, Co, Ni, Cu and Zn in the suspended particles are higher in the Krishna River than in the world's average, indicating pollution inputs. Suspended sediments are enriched (5 to 10 times) in all the elements considered relative to bed sediments. Downstream profile and metal/Al ratios of the elements indicate that the mobility of elements within the basin is controlled by basin geology, size and mineralogical characteristics. Good correlations observed for a number of elements point out to their common sink in the clay fraction of the sediments. There is no systematic variation with depth for the major elements and most of the elements are considerably higher compared to estuarine or Bay of Bengal sediments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0009-2541(89)90042-9
|
“Elemental composition of mineral aerosol generated from Sudan Sahara sand”. Eltayeb MAH, Injuk J, Maenhaut W, Van Grieken RE, Journal of atmospheric chemistry 40, 247 (2001). http://doi.org/10.1023/A:1012272208129
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1012272208129
|
“Elemental trace analysis of small samples by proton-induced X-ray-emission”. Johansson TB, Van Grieken RE, Nelson JW, Winchester JW, Analytical chemistry 47, 855 (1975). http://doi.org/10.1021/AC60356A035
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC60356A035
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
“Enhancement effect in X-ray fluorescence analysis of environmental samples of medium thickness”. Van Dyck PM, Török SB, Van Grieken RE, Analytical chemistry 58, 1761 (1986). http://doi.org/10.1021/AC00121A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00121A036
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Epidermal patch with glucose biosensor : pH and temperature correction toward more accurate sweat analysis during sport practice”. Wiorek A, Parrilla M, Cuartero M, Crespo GA, Analytical Chemistry 92, 10153 (2020). http://doi.org/10.1021/ACS.ANALCHEM.0C02211
Abstract: We present an epidermal patch for glucose analysis in sweat incorporating for the first time pH and temperature correction according to local dynamic fluctuations in sweat during on-body tests. This sort of correction is indeed the main novelty of the paper, being crucial toward reliable measurements in every sensor based on an enzymatic element whose activity strongly depends on pH and temperature. The results herein reported for corrected glucose detection during on-body measurements are supported by a two-step validation protocol: with the biosensor operating off- and on-bodily, correlating the results with UV-vis spectrometry and/or ion chromatography. Importantly, the wearable device is a flexible skin patch that comprises a microfluidic cell designed with a sweat collection zone coupled to a fluidic channel in where the needed electrodes are placed: glucose biosensor, pH potentiometric electrode and a temperature sensor. The glucose biosensor presents a linear range of response within the expected physiological levels of glucose in sweat (10-200 mu M), and the calibration parameters are dynamically adjusted to any change in pH and temperature during the sport practice by means of a new “correction approach”. In addition, the sensor displays a fast response time, appropriate selectivity, and excellent reversibility. A total of 9 validated on-body tests are presented: the outcomes revealed a great potential of the wearable glucose sensor toward the provision of reliable physiological data linked to individuals during sport activity. In particular, the developed “correction approach” is expected to impact into the next generation of wearable devices that digitalize physiological activities through chemical information in a trustable manner for both sport and healthcare applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.0C02211
|
“An expert system for chemical speciation of individual particles using low-Z particle electron probe X-ray microanalysis data”. Ro C-U, Kim HK, Van Grieken R, Analytical chemistry 76, 1322 (2004). http://doi.org/10.1021/AC035149I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC035149I
|
“Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent”. György K, Ajtony Z, van Meel K, Van Grieken R, Czitrovszky A, Bencs L, Talanta : the international journal of pure and applied analytical chemistry 85, 1253 (2011). http://doi.org/10.1016/J.TALANTA.2011.05.028
Abstract: A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO3) and bismuth tellurite (Bi2TeO5) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl4) was dispensed with a conventional autosampler into the graphite tube. The CCl4 was partially dried at 80 °C under the mini-flow (40 cm3 min−1) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 19002100 °C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100 °C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L−1 for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L−1 were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol−1 Er and 11 μmol mol−1 Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2011.05.028
|
“Ferrihydrite precipitation in groundwater-fed river systems (Nete and Demer river basins, Belgium) : insights from a combined Fe-Zn-Sr-Nd-Pb-isotope study”. Dekov VM, Vanlierde E, Billström K, Gatto Rotondo G, van Meel K, Darchuk L, Van Grieken R, et al, Chemical geology 386, 1 (2014). http://doi.org/10.1016/J.CHEMGEO.2014.07.023
Abstract: Two groundwater-fed river systems (Nete and Demer, Belgium) carry red suspended material that settles on the river bed forming red sediments. The local aquifer that feeds these river systems is a glauconite-rich sand, which provides most of the dissolved Fe to the rivers. The solid component of these systems, i.e., the red suspended material and sediments, has a simple mineralogy (predominantly ferrihydrite), but shows a complex geochemistry pointing out the different processes contributing to the river chemistry: (1) the red sediments have higher transition metal (excluding Cu) and detrital element (e.g., Si, Al, K, Rb, etc.) concentrations than the red suspended matter because of their longer residence time in the river and higher contribution of the background (aquifer) component, respectively; (2) the red suspended material and sediments have inherited their rare earth element (REE) patterns from the aquifer; (3) the origin of Sr present in the red suspended matter and red sediments is predominantly marine (i.e., Quaternary calcareous rocks), but a small amount is geogenic (i.e., from detrital rocks); (4) Pb in both solids originates mostly from anthropogenic and geogenic sources; (5) all of the anthropogenic Pb in the red suspended material and sediments is hosted by the ferrihydrite; (6) Nd budget of the red riverine samples is controlled by the geogenic source and shows little anthropogenic component; (7) the significant Fe- and Zn-isotope fractionations are in line with the previous studies. Their fractionation patterns do not correlate, suggesting that the processes controlling the isotope geochemistry of Fe and Zn are different: oxidation/reduction most likely governs the Fe-isotope fractionation, whereas adsorption/desorption or admixing of anthropogenic sources controls the isotope fractionation of Zn.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHEMGEO.2014.07.023
|
“Geochemical characterization of recent sediments in the Baltic Sea by bulk and electron microprobe analysis”. Belmans F, Van Grieken R, Brügmann L, Marine chemistry 42, 223 (1993). http://doi.org/10.1016/0304-4203(93)90014-F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(93)90014-F
|
“Geochemistry of suspended matter from the baltic sea : 1 : results of individual particle characterization by automated electron microprobe”. Bernard PC, Van Grieken RE, Brügmann L, Marine chemistry 26, 155 (1989). http://doi.org/10.1016/0304-4203(89)90058-3
Abstract: Automated electron probe X-ray microanalysis was used to characterize some 15 000 individual suspension particles from 50 samples of suspended matter collected from different depths at 18 stations throughout the Baltic Sea and the transient area to the North Sea. For each particle, 14 minor and major elements were determined and size information data were obtained. To process this huge amount of results, multivariate analysis techniques were invoked: the particles were classified into specific types and the abundance variations of these groups were studied. It appeared that 80% of all investigated particles contained mostly silicon, and seemed to consist of quartz, and K-rich and Fe-rich aluminosilicates. The abundance of BaSO4 particles averaged 5% throughout the Baltic Sea, but amounted to up to 44% at some stations. The abundance of the Fe-rich particles varied significantly with location and depth, and averaged ∼ 4%. They were often found to be associated with significant amounts of P. Both of these particle types and the Mn-rich particles are thought to be mainly authigenic. Calcium carbonate particles are more abundant towards the North Sea (which seems to act as a source). Principal component analysis of the data revealed that most of the compositional variability can be explained by differences between deep and surface waters and by the influences of inflowing North Sea waters. Additional information about the types and sources of the suspended matter in the Baltic Sea was gained from the comparison and correlation of the single particle results with different fractions of the bulk concentrations of elements such as Al, Ca, Mn, Fe, Zn and Ba.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(89)90058-3
|
“Geochemistry of suspended matter from the Baltic Sea: 2: results of bulk trace metal analysis by AAS”. Brügmann L, Bernard PC, Van Grieken R, Marine chemistry 38, 303 (1992). http://doi.org/10.1016/0304-4203(92)90039-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(92)90039-D
|
“Grazing exit electron probe microanalysis for surface and particle analysis”. Tsuji K, Wagatsuma K, Nullens R, Van Grieken RE, Analytical chemistry 71, 2497 (1999). http://doi.org/10.1021/AC990075P
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990075P
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
“High-energy polarized-beam energy-dispersive X-ray fluorescence analysis combined with activated thin layers for cadmium determination at trace levels in complex environmental liquid samples”. Marguí, E, Fontàs C, van Meel K, Van Grieken R, Queralt I, Hidalgo M, Analytical chemistry 80, 2357 (2008). http://doi.org/10.1021/AC7018427
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC7018427
|
“Impedimetric sensing of the immuno-enzymatic reaction of gliadin with a collagen-modified electrode”. Bottari F, Moretto LM, Ugo P, Electrochemistry communications 97, 51 (2018). http://doi.org/10.1016/J.ELECOM.2018.10.011
Abstract: This paper presents a previously unexplored biosensing strategy for detecting gliadin which exploits the crosslinking of gliadin with collagen, catalyzed by transglutaminase at the interfacial electron transfer rate, on a modified electrode. The process is monitored by electrochemical impedance spectroscopy using a glassy carbon electrode coated with a collagen layer. To validate the specificity of the response as well as to eliminate possible interferences from other proteins, such as soy protein or casein, the captured gliadin is further reacted with a specific anti-gliadin antibody. Changes in charge transfer resistance, measured from the Nyquist plots, scale linearly with the gliadin concentration in the range 5-20 mg/L, a range suitable for testing the gliadin concentration in gluten-free food commodities.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ELECOM.2018.10.011
|
“Individual particle analysis of Western Mediterranean sediment cores, Rhône suspended matter and Sahara aerosols: investigation of inputs to the sediments”. Wegrzynek D, Jambers W, Van Grieken R, Eisma D, Marine chemistry 57, 25 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Influence of fixation procedures on the microanalysis of lead-induced intranuclear inclusions in rat kidney”. Vandeputte DF, Jacob WA, Van Grieken RE, The journal of histochemistry and cytochemistry 38, 331 (1990). http://doi.org/10.1177/38.3.2154517
Abstract: Using Laser Microprobe Mass Analysis (LAMMA), we studied the chemical composition of lead-induced intranuclear inclusions in rat kidney tissue prepared by three different wet chemical fixation procedures for transmission electron microscopy. Fixation with glutaraldehyde-Na2S gave the same results as fixation with glutaraldehyde only: a high lead concentration could be detected. Therefore, for lead strongly bound to proteins, precipitation procedures are not essential. Post-fixation with osmium tetroxide drastically changed the composition of the inclusions: the lead concentration decreased substantially, while sodium, calcium, and barium were introduced. The osmium tetroxide fixative was found to be the source of the contamination. It also contained aluminum, and we suggest that other proteins (e.g., in neurofibrillary tangles) might be able to take up Al out of solution and that care must be exercised in interpreting the microanalytical results of osmium-fixed material. For the microanalysis of the lead inclusions, fixation with glutaraldehyde only provides a good compromise between preservation of the ultrastructure and maintenance of the element distribution.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1177/38.3.2154517
|
“Interface for reproducible, multishot direct analysis of solid-phase microextraction samples”. Newsome GA, Kavich G, Alvarez-Martin A, Analytical Chemistry 92, 4182 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05691
Abstract: An enclosed interface that joins a direct analysis in real time (DART) probe, solid-phase microextraction (SPME) fiber, and the inlet of a high-resolution mass spectrometer is described. Unlike other systems to couple SPME sampling to ambient mass spectrometry, the interface is able to perform discrete analyses on different areas of a single SPME fiber device for up to three technical replicate measurements of one sampling event. Inlet flow speed and desorption temperature are optimized, and reproducibility is demonstrated between replicate analyses on the same derivatized SPME fiber and with sequential fiber sampling events, yielding analyte measurement center of variance (CV) from 3 to 6%. Conditioning is also performed with the enclosed DART. The interface is a straightforward addition to commercially available technologies, and machine diagrams for custom components operated with SPME/DART/MS equipment are included.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05691
|
“Investigation of heterogeneous reactions of PAH's on particle surfaces using laser microprobe mass analysis”. Niessner R, Klockow D, Bruynseels F, Van Grieken R, International journal of environmental analytical chemistry 22, 281 (1985). http://doi.org/10.1080/03067318508076427
Abstract: Artificially generated NaCl particles were coated with PAH's by using a condensation technique. These particles were exposed to reactive gases like ozone, bromine and nitrogen dioxide. The original as well as the exposed particles were investigated by fluorimetric analysis and by LAMMA (Laser Microprobe Mass Analysis) in the desorption mode, which allows the evaporation and characterization of surfaces of single particles. The results are interpreted in terms of possible heterogeneous atmospheric reactions. The reactivity of the considered PAH's towards nitrogen dioxide was found to be negligible. The structure of the reaction products formed with ozone was partially elucidated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076427
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|