|
“Degradation of galvanised iron roofing material in Tanzania by atmospheric corrosion”. Potgieter-Vermaak SS, Mmari A, Van Grieken R, McCrindle RI, Potgieter JH, Corrosion engineering science and technology 46, 642 (2011). http://doi.org/10.1179/147842210X12695149033972
Abstract: Galvanised iron is popular in many applications, particular as a roofing material. However, just like other materials, especially metallic ones, it is prone to degradation by corrosion. In this particular study, the degradation of galvanised roof sheets was investigated at a coastal, urban and rural site in Tanzania, Africa. Samples were exposed to various outdoor environments over a period of 3 years. In addition, some accelerated laboratory investigations were conducted in different simulated air pollution environments in an artificial corrosion chamber constructed for this purpose to supplement the outdoor exposure tests. It was found that the combination of the tropical climate and increasing air pollution due to industrial development in the capital Dar-es-Salaam resulted in substantial atmospheric corrosion of the roof sheets, which eventually leads to failure and the necessity for replacement. The rural site had the lowest degree of atmospheric corrosion as expected. A combination of different corrosion products was identified as a result of the atmospheric corrosion by Raman and EDX analyses. The information gained from this investigation could be utilised to construct more durable structures requiring less frequent replacement and maintenance in future.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1179/147842210X12695149033972
|
|
“Degradation potential of airborne particulate matter at the Alhambra monument : a Raman spectroscopic and electron probe X-ray microanalysis study”. Potgieter-Vermaak S, Horemans B, Anaf W, Cardell C, Van Grieken R, Journal of Raman spectroscopy 43, 1570 (2012). http://doi.org/10.1002/JRS.4052
Abstract: It is well known that airborne particulate matter (APM) has an impact on our cultural heritage. A limited number of articles have been published on the sequential application of elemental and molecular techniques to estimate the degradation potential of APM in environments of cultural heritage importance, and most of these were concerned with indoor environments. The Alhambra monument (Granada, Spain) represents one of the grandest and finest examples of Islamic art and architecture from the Middle Ages. As part of an air quality investigation, two sets of APM were collected at the Hall of the Ambassadors and characterised to determine its potential degradation profile. These were analysed by means of micro-Raman spectroscopy (MRS) and electron probe microanalysis with X-ray detection (EPXMA). The Raman data indicated the presence of various mixed salts of acidic and/or hygroscopic nature, such as sodium and ammonium nitrates and sulfates, especially in the finer fraction. Automated EPXMA estimated this fraction to be as high as 50%. Apart from the potential chemical attack, the soiling due to carbonaceous matter deposition is a real concern. Soot was identified by MRS and EPXMA in all size fractions, reaching values of up to 55%, and was often intertwined with soluble inorganic salts. Ongoing degradation of the pigments is implicated by the presence of brightly coloured particles. MRS and molar abundance ternary diagrams elicited the chemical structure of individual APM so that the degradation potential could be established.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/JRS.4052
|
|
“Deposition of atmospheric trace elements into the North Sea: coastal, ship, platform measurements and model predictions”. Injuk J, Van Grieken R, de Leeuw G, Atmospheric environment : an international journal 32, 3011 (1998). http://doi.org/10.1016/S1352-2310(97)00497-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S1352-2310(97)00497-4
|
|
“Desorption-ionization of inorganic compounds in Fourier transform laser microprobe mass spectrometry with external ion source”. Struyf H, Van Vaeck L, Van Grieken R, Rapid communications in mass spectrometry 10, 551 (1996). http://doi.org/10.1002/(SICI)1097-0231(19960331)10:5<551::AID-RCM414>3.0.CO;2-S
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-0231(19960331)10:5<551::AID-RCM414>3.0.CO;2-S
|
|
“Detection limits of grazing-exit EPMA for particle analysis”. Tsuji K, Spolnik Z, Wagatsuma K, Nullens R, Van Grieken RE, Microchimica acta 132, 357 (2000). http://doi.org/10.1007/S006040050080
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050080
|
|
“Determination of barium, lanthanum, cerium and neodymium in lateritic materials by various energy-dispersive X-ray fluorescence techniques and neutron activation analysis”. Labrecque JJ, Beusen JM, Van Grieken RE, X-ray spectrometry 15, 13 (1986). http://doi.org/10.1002/XRS.1300150105
Abstract: A comparison of four methods for the determination of barium, lanthanum, cerium and neodymium in lateritic materials from Brazil is presented. Three of the methods were based on x-ray fluorescence (XRF) spectroscopy: two by radioisotope excitation (Co-57 and Am-241) and one by secondary target XRF (a molybdenum target with a tungsten anode). The other method was based on neutron activation analysis employing both a Ge(Li) coaxial detector and a high-purity germanium detector. The results from these four methods were similar for lanthanum, cerium and neodymium, but for barium at low concentrations (<500 ppm) the neutron activation and the secondary target XRF methods were not suitable. Data on the precision and accuracy of these methods using a series of standard reference rocks are given. The advantages and limitations of each of these methods with respect to the analysis of lateritic materials are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150105
|
|
“Determination of chemical composition of individual airborne particles by SEM/EDX and micro-Raman spectrometry : a review”. Stefaniak EA, Buczyńska A, Novakovic V, Kuduk R, Van Grieken R, Journal of physics : conference series 162, 012019 (2009). http://doi.org/10.1088/1742-6596/162/1/012019
Abstract: The strategies for sampling and analysis by SEM/EDX and micro-Raman spectrometry for individual airborne particles analysis as applied at the University of Antwerp (Belgium) by the MITAC group have been reviewed. Microbeam techniques provide detailed information concerning the origin, formation, transport, reactivity, transformation reactions and environmental impact of particulate matter. Moreover, some particles of certain chemical properties have been recognized as a threat for human health and cultural heritage objects. However, the small sizes of particles result in specific problems with respect to single particle analysis. Development of equipment and software for improvement of analysis and quantification are reported.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1088/1742-6596/162/1/012019
|
|
“Determination of chemical species in individual aerosol particles using ultrathin window EPMA”. Ro C-U, Osán J, Szalóki I, Oh K-Y, Kim H, Van Grieken R, Environmental science and technology 34, 3023 (2000). http://doi.org/10.1021/ES9910661
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES9910661
|
|
“The determination of copper in iron and steel by 14-Mev neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 51, 151 (1970). http://doi.org/10.1016/S0003-2670(01)95703-4
Abstract: A fast (10 min) non-destructive determination of copper in. steel and cast iron by 14-MeV neutron activation analysis is described. The 0.511-MeV annihilation radiation of62Cu (T1/2=9.8 min), induced by the reaction63Cu(n,2n)62Cu, is counted by two opposing NaI(Tl) detectors operating in coincidence. An oxygen flux monitor is used to normalise the irradiations. For high phosphorus contents, two measurements are made and the 9-min activity contribution is calculated. As the iron content of the samples is known, the use of pure iron samples allows correction for53Fe activity from the reaction54Fe(n,2n)53Fe(T1/2= 8.9 min). When the phosphorus and silicon activities are low, the procedure of counting and computing can be greatly simplified. Nuclear interferences of most common alloying and impurity elements were investigated.The precision is 23% for steels containing above 1% Cu, andCa. 10% for 0.1%Cu.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95703-4
|
|
“Determination of low-Z elements in individual environmental particles using windowless EPMA”. Ro C-U, Osán J, Van Grieken R, Analytical chemistry 71, 1521 (1999). http://doi.org/10.1021/AC981070F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC981070F
|
|
“Determination of methanesulfonic acid and non-sea-salt sulfate in single marine aerosol particles”. Kolaitis LN, Bruynseels FJ, Van Grieken RE, Andreae MO, Environmental science and technology 23, 236 (1989). http://doi.org/10.1021/ES00179A018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00179A018
|
|
“Determination of platinum, palladium, and rhodium in automotive catalysts using high-energy secondary target X-ray fluorescence spectrometry”. van Meel K, Smekens A, Behets M, Kazandjian P, Van Grieken R, Analytical chemistry 79, 6383 (2007). http://doi.org/10.1021/AC070815R
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC070815R
|
|
“Determination of protein-bound copper and zinc in some organs of the cuttlefish Sepia officinalis L”. Decleir W, Vlaeminck A, Geladi P, Van Grieken R, Comparative biochemistry and physiology : B : biochemistry and molecular biology 60, 347 (1978). http://doi.org/10.1016/0305-0491(78)90057-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0305-0491(78)90057-3
|
|
“Determination of rare earth elements in geological materials by total reflection X-ray fluorescence”. Muia LM, Van Grieken R, Analytica chimica acta 251, 177 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
|
“Determination of trace elements in organic matrices by grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken R, Analytica chimica acta 401, 293 (1999). http://doi.org/10.1016/S0003-2670(99)00471-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(99)00471-7
|
|
“Determination of trace metals in rain water by differential-pulse stripping voltammetry”. Vos L, Komy G, Reggers G, Roekens E, Van Grieken R, Analytica chimica acta 184, 271 (1986). http://doi.org/10.1016/S0003-2670(00)86491-0
Abstract: Differential-pulse stripping voltammetry is applied to measure zinc, cadmium, lead and copper by anodic stripping and selenium(IV) by cathodic stripping in rain water at pH 2; subsequently, at pH 9,1, manganese is measured by anodic stripping on the same portion, and cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The instrumental parameters are optimized. The linear ranges, mutual interferences and detection limits are studied. Excellent accuracy is demonstrated; the standard deviation is around 15% at 2.550 μg l−1 levels. The method is shown to be applicable for rain water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86491-0
|
|
“Determination of trace selenium in biological material by preconcentration and X-ray emission spectrometry”. Robberecht H, Van Grieken R, Analytica chimica acta 147, 113 (1983). http://doi.org/10.1016/0003-2670(83)80077-4
Abstract: Selenium is determined in the ng g−1 to μg g−1 range in biological and environmental samples. A wet digestion procedure was optimized with respect to volatility losses and recovery yields, by using 75Se metabolically incorporated into rat organs. Selenium is preconcentrated from the digestion liquid by a two-step reduction with 4 M HCl and ascorbic acid. The colloidal selenium formed is adsorbed on activated carbon and filtered on a Nucleopore membrane for measurement by energy-dispersive x-ray fluorescence. Almost complete recovery was obtained, and the detection limit was 20 ng, corresponding to 10 ng g−1 for a 2-g sample. Biological reference materials were analyzed with satisfactory results, and the accuracy of the method was good.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(83)80077-4
|
|
“Direct current glow discharge mass spectrometric analysis of Macor ceramic using a secondary cathode”. Schelles W, Van Grieken R, Analytical chemistry 68, 3570 (1996). http://doi.org/10.1021/AC960441U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC960441U
|
|
“Direct current glow discharge mass spectrometry for elemental characterization of polymers”. Schelles W, Van Grieken R, Analytical chemistry 69, 2931 (1997). http://doi.org/10.1021/AC970186T
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC970186T
|
|
“Direct detection of sulfate and nitrate layers on sampled marine aerosols by laser microprobe mass analysis”. Bruynseels F, Van Grieken R, Atmospheric environment 19, 1969 (1985). http://doi.org/10.1016/0004-6981(85)90023-X
Abstract: The direct detection of sulfate and nitrate layers on sampled marine aerosols was carried out by laser microprobe mass analysts.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0004-6981(85)90023-X
|
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
|
“Dispersal of suspended matter in Makasar Strait and the Flores Basin”. Eisma D, Kalf J, Karmini M, Mook WG, Van Put A, Bernard P, Van Grieken R, Netherlands journal of sea research 24, 383 (1989). http://doi.org/10.1016/0077-7579(89)90116-6
Abstract: In November 1984 in Makasar and the Flores Basin water samples were collected (T, S, dissolved O2, total CO2), bottom samples (sediment composition) and suspended matter (particle composition, particle size). A sediment trap was moored in the Flores Basin at 4600 m depth for nearly four months, covering the dry season. In the Flores Basin there are indications for bottom flow resuspending bottom material or preventing suspended material from settling; in Makasar Strait there is probably inflow of deep water both from the south and from the north, resulting in a very slow bottom water flor. Bottom deposits in Makasar Strait and the Flores Basin are predominantly terrigenous, with an admixture of organic carbonate and silica (mostly coccoliths). Volcanic material is primarily present near to the volcanoes in the south and reaches the deeper basins by slumping. In the suspended matter no volcanic particles and little planktonic material were found, although the latter form 10 to 15% of the top sediment and of the material deposited in the sediment trap. In suspension particles with a large concentration of tin (Sn) were found associated mainly with iron. They probably come from northern Kalimantan or northern Sulawesi. Suspended matter concentrations were mainly less than 0.5 mg·dm−3, only off the Mahakam river mouth were concentrations higher than 1 mg·dm−3. Particle size was erratic because of the variable composition of the coarser particles in suspension. Organic matter concentrations in suspension (in mg·dm−3) roughly follow the distribution of total suspended matter but organic content (in %) of the suspended matter does not show any trends. All organic matter in suspension is of marine origin except in the Mahakam river and estuary. Deposition rates, as estimated from the sediment trap results, are 150 mg·cm−2·a−1 for the total sediment, 26 mg·cm−2·a−1 for carbonate and 13 mg·cm−2·a−1 for organic matter. Flocs and fibres in suspension were only found in and below the Mahakam river plume that reaches ca 400 km from the river mouth to the southeast, and in surface waters associated with plankton (diatoms). The formation of these flocs (broken-up macroflocs or marine snow) is primarily related to particle concentration, turbulence, and the presence of organisms that produce sticky material or glue particles together.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(89)90116-6
|
|
“Distribution of atmospheric marine salt depositions over Continental Western Europe”. Delalieux F, Van Grieken R, Potgieter JH, Marine pollution bulletin 52, 606 (2006). http://doi.org/10.1016/J.MARPOLBUL.2005.08.018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MARPOLBUL.2005.08.018
|
|
“Doped albumin : stndardization possibilities for LAMMA-analysis of thin freeze-dried cryosections of biological tissue”. Verbueken AH, Jacob WA, Frederik PM, Busing WM, Hersten RC, Van Grieken RE, Journal de physique 45, 561 (1984)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
“Dry and wet deposition fluxes of Cd, Cu, Pb, and Zn into the Southern Bight of the North Sea”. Rojas CM, Injuk J, Van Grieken R, Laane RW, Atmospheric environment: part A : general topics 27, 251 (1993). http://doi.org/10.1016/0960-1686(93)90355-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90355-3
|
|
“Editorial : award for best X-Ray Spectrometry referee during 2011-2012”. Van Grieken R, X-ray spectrometry 42, 3 (2013). http://doi.org/10.1002/XRS.2428
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2428
|
|
“Editorial: Award for best XRS referee during 2007-2008”. Van Grieken R, X-ray spectrometry 37, 571 (2008). http://doi.org/10.1002/XRS.1107
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1107
|
|
“Editorial : introducing Dr Markowicz as X-Ray Spectrometry's new associate editor for Europe”. Van Grieken R, X-ray spectrometry 42, 175 (2013). http://doi.org/10.1002/XRS.2447
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2447
|
|
“EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials”. Belikov KN, Mikhailova LI, Spolnik ZM, Van Grieken R, X-ray spectrometry 35, 112 (2006). http://doi.org/10.1002/XRS.874
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.874
|