|
“Organische TOF-S-SIMS: gebruik van opgedampt Ag en Au voor de verhoging van secundaire ionenintensiteiten”. Adriaensen L, Vangaever F, Gijbels R, Chemie magazine , 10 (2004)
Keywords: A2 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Een tweede leven voor broeikasgassen?”.Paulussen S, Sels B, Bogaerts A, Paul J, Het ingenieursblad : maandblad van de Koninklijke Vlaamse Ingenieursvereniging KVIV 77, 16 (2008)
Keywords: A2 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Characterization of nano-crystalline diamond films grown under continuous DC bias during plasma enhanced chemical vapor deposition”. Mortet V, Zhang L, Echert M, Soltani A, d' Haen J, Douheret O, Moreau M, Osswald S, Neyts E, Troadec D, Wagner P, Bogaerts A, Van Tendeloo G, Haenen K, Materials Research Society symposium proceedings (2009). http://doi.org/10.1557/PROC-1203-J05-03
Abstract: Nanocrystalline diamond films have generated much interested due to their diamond-like properties and low surface roughness. Several techniques have been used to obtain a high re-nucleation rate, such as hydrogen poor or high methane concentration plasmas. In this work, the properties of nano-diamond films grown on silicon substrates using a continuous DC bias voltage during the complete duration of growth are studied. Subsequently, the layers were characterised by several morphological, structural and optical techniques. Besides a thorough investigation of the surface structure, using SEM and AFM, special attention was paid to the bulk structure of the films. The application of FTIR, XRD, multi wavelength Raman spectroscopy, TEM and EELS yielded a detailed insight in important properties such as the amount of crystallinity, the hydrogen content and grain size. Although these films are smooth, they are under a considerable compressive stress. FTIR spectroscopy points to a high hydrogen content in the films, while Raman and EELS indicate a high concentration of sp2 carbon. TEM and EELS show that these films consist of diamond nano-grains mixed with an amorphous sp2 bonded carbon, these results are consistent with the XRD and UV Raman spectroscopy data.
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1557/PROC-1203-J05-03
|
|
|
“Application of neural networks in image analysis: the classification of geometrical shapes”. Geuens I, Nys B, Gijbels R, Jacob W, CC-AI: the journal for the integrated study of artificial intelligence, cognitive science and applied epistemology 10, 61 (1993)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Chemical analysis in metal processing: overview and future needs in refined and ultrapure metals”. Gijbels R, Acta technica Belgica: metallurgie 30, 91 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Comparative bulk, surface and depth profile analyses on AIN and SiC-coated B4C powders”. Jenett H, Grallath E, Riedel R, Strecker K, Gijbels R, Kennis P, Fres J. Anal. Chem. 341, 265 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
|
|
|
“Corrélations chimiques-géothermométriques des paramètres microchimiques des hydrothermes profonds”. Pentcheva E, Van 't dack L, Veldeman E, Gijbels R, Comptes rendus de l'Académie bulgare des sciences 49, 61 (1996)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“The dawn of surface analysis that stands by the side users: ultra-thin film analysis by rf-GDOES”. Shimizu K, Habazaki H, Bender H, Gijbels R, Engineering materials 52, 97 (2004)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Development of a Fourier transform laser microprobe mass spectrometer with external ion source”. Gijbels R, ICR/Ion trap newsletter 30 (1993)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Evolution of impurity clusters and photographic sensitivity”. Oleshko VP, Gijbels RH, Bilous VM, Jacob WA, Alfimov MV, Zhurnal nauchnoj prikladnoj fotografii i kinematografii 45, 1 (2000)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Modeling of glow discharge ion sources for mass spectrometry: potentials and limitations”. Gijbels R, Bogaerts A, Spectroscopy 9, 8 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Modeling of glow discharges: what can we learn from it?”.Bogaerts A, Gijbels R, Analytical chemistry A-pages 69, 719 (1997)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Modeling of radio-frequency and direct current glow discharges in argon”. Bogaerts A, Gijbels R, Journal of technical physics 41, 183 (2000)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“On estimation of the dielectric function of Ag(Br,I) nanocrystals by cryo-EELS (addendum)”. Oleshko VP, Gijbels RH, van Daele AJ, Jacob WA, Nanostructered materials 11, 687 (1999)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Sample erosion studies in a glow discharge ionization cell”. van Straaten M, Vertes A, Gijbels R, Spectrochimica acta 46b, 283 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Structural analysis of silver halide cubic microcrystals with epitaxial or conversion growths by STEM-EDX”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Mikrochimica acta: supplementum 12, 261 (1992)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Sur les processus, controlant le caractère hydrochimique des eaux thermales profondes (Bulgarie Méridionale)”. Pentcheva E, Veldeman E, Van 't dack L, Gijbels R, Comptes rendus de l'Académie bulgare des sciences 44, 51 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Trace element and micro-mineral composition of some selected anhydrite samples from the Saint Ghislain drill hole (Hainaut, Belgium)”. Vandelannoote R, Van 't dack L, Gijbels R, Bulletin van de Belgische Vereniging voor Geologie 95, 101 (1986)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“L'analyse des eaux géothermales par spectrométrie de masse à, étincelles”. Vandelannoote R, Blommaert W, van Grieken R, Gijbels R, Spectra 2000: la revue de l'instrumentation 53, 66 (1979)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Analysis of geothermal waters by spark source mass spectrometry”. Vandelannoote R, Blommaert W, Gijbels R, van Grieken R, Fresenius' Zeitschrift für analytische Chemie 309, 291 (1981). http://doi.org/10.1007/BF00488604
Abstract: Although the analysis of thermal water by spark-source mass spectrometry (SSMS) is rather timeconsuming, it allows the detection of about 20 elements of geochemical interest down to the ppb-level. A physical preconcentration is proposed in order to collect elements having quite different chemical properties, e.g. alkalis, transition elements, and elements occurring in anionic form. The relative sensitivity factors appear to be rather independent of the salt content of the graphite electrodes. Contrary to neutron activation analysis, SSMS has a quite uniform elemental sensitivity, and allows to determine elements for which neutron activation is not suitable, e.g. Sn and Pb. The precision of SSMS is however by a factor of about 2 worse than that obtained for neutron activation.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 8
DOI: 10.1007/BF00488604
|
|
|
“Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multi-element analysis of geothermal waters”. Blommaert W, Vandelannoote R, Van 't dack L, Gijbels R, van Grieken R, Journal of radioanalytical chemistry 57, 382 (1980)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Statistical grouping and controlling factors of dissolved trace elements in a surface water system”. Vandelannoote R, Blommaert W, Van 't dack L, Gijbels R, van Grieken R, Environmental technology letters 4, 363 (1983). http://doi.org/10.1080/09593338309384219
Abstract: Sensitive multi‐element analytical techniques were applied to determine 24 dissolved trace components in 25 different water samples from a 10 km2 zone in Brittany, France. Correspondence factor and multiple regression analyses showed that the elements considered are influenced mainly by the presence of: Fe‐Mn oxide accumulations, a local poly‐metallic sulfide mineralization, and non‐mineralized host rocks, agricultural activity and abundant organic material in local swamps. Via these numerical techniques the location of the poly‐metallic ore body can be derived from the data set.
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 1
DOI: 10.1080/09593338309384219
|
|
|
“How would a superconducting liquid flow in a magnetic field?”.Maeyens A, Tempère J, Europhysics news 38, 18 (2007)
Keywords: A3 Journal article; Theory of quantum systems and complex systems; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Chirumamilla CS, Palagani A, Kamaraj B, Declerck K, Verbeek MWC, Ryabtsova O, De Bosscher K, Bougarne N, Ruttens B, Gevaert K, Houtman R, De Vos WH, Joossens J, van der Veken P, Augustyns K, van Ostade X, Bogaerts A, De Winter H, Vanden Berghe W (2017) Selective glucocorticoid receptor properties of GSK866 analogs with cysteine reactive warheads. Place of publication unknown, 1324
Abstract: Synthetic glucocorticoids (GC) are the mainstay therapy for treatment of acute and chronic inflammatory disorders. Due to the high adverse effects associated with long-term use, GC pharmacology has focused since the nineties on more selective GC ligand-binding strategies, classified as selective glucocorticoid receptor (GR) agonists (SEGRAs) or selective glucocorticoid receptor modulators (SEGRMs). In the current study, GSK866 analogs with electrophilic covalent-binding warheads were developed with potential SEGRA properties to improve their clinical safety profile for long-lasting topical skin disease applications. Since the off-rate of a covalently binding drug is negligible compared to that of a non-covalent drug, its therapeutic effects can be prolonged and typically, smaller doses of the drug are necessary to reach the same level of therapeutic efficacy, thereby potentially reducing systemic side effects. Different analogs of SEGRA GSK866 coupled to cysteine reactive warheads were characterized for GR potency and selectivity in various biochemical and cellular assays. GR- and NFκB-dependent reporter gene studies show favorable anti-inflammatory properties with reduced GR transactivation of two non-steroidal GSK866 analogs UAMC-1217 and UAMC-1218, whereas UAMC-1158 and UAMC-1159 compounds failed to modulate cellular GR activity. These results were further supported by GR immuno-localization and S211 phospho-GR western analysis, illustrating significant GR phosphoactivation and nuclear translocation upon treatment of GSK866, UAMC-1217, or UAMC-1218, but not in case of UAMC-1158 or UAMC-1159. Furthermore, mass spectrometry analysis of tryptic peptides of recombinant GR ligand-binding domain (LBD) bound to UAMC-1217 or UAMC-1218 confirmed covalent cysteine-dependent GR binding. Finally, molecular dynamics simulations, as well as glucocorticoid receptor ligand-binding domain (GR-LBD) coregulator interaction profiling of the GR-LBD bound to GSK866 or its covalently binding analogs UAMC-1217 or UAMC-1218 revealed subtle conformational differences that might underlie their SEGRA properties. Altogether, GSK866 analogs UAMC-1217 and UAMC-1218 hold promise as a novel class of covalent-binding SEGRA ligands for the treatment of topical inflammatory skin disorders.
Keywords: Administrative Services; A1 Journal article; Pharmacology. Therapy; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Medicinal Chemistry (UAMC)
Impact Factor: 6.429
Times cited: 2
DOI: 10.3389/FIMMU.2017.01324
|
|
|
Grü,newald L, Chezganov D, De Meyer R, Orekhov A, Van Aert S, Bogaerts A, Bals S, Verbeeck J (2023) Supplementary Information for “In-situ Plasma Studies using a Direct Current Microplasma in a Scanning Electron Microscope”
Abstract: Supplementary information for the article “In-situ Plasma Studies using a Direct Current Microplasma in a Scanning Electron Microscope” containing the videos of in-situ SEM imaging (mp4 files), raw data/images, and Jupyter notebooks (ipynb files) for data treatment and plots. Link to the preprint: https://doi.org/10.48550/arXiv.2308.15123 Explanation of the data files can be found in the Information.pdf file. The Videos folder contains the in-situ SEM image series mentioned in the paper. If there are any questions/bugs, feel free to contact me at lukas.grunewaldatuantwerpen.be
Keywords: Dataset; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.5281/ZENODO.8042030
|
|
|
Ghorbanfekr Kalashami H (2019) Graphene-based membranes and nanoconfined water : molecular dynamics simulation study. 243 p
Keywords: Doctoral thesis; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Wang J (2022) Plasma catalysis : study of CO2 reforming of CH4 in a DBD reactor. XVI, 232 p
Abstract: The plasma-based dry reforming in a dielectric barrier discharge (DBD) reactor is important to achieve sustainable goals, but many challenges remain. For example, the conversion and energy yield of DBD reactors are relatively low, and the catalysts or packing materials used in existing studies cannot improve them, possibly due to the unsuitable properties and structures of catalysts or packing materials for plasma processes. In order to study the effect of catalyst structure on plasma-based dry reforming, a controllable synthesis of the catalyst supports or templates was explored. In Chapter 2, an initially immiscible synthesis method was proposed to synthesize uniform silica spheres, which can replace the organic solvent-based Stöber method to successfully synthesize silica particles with the same size ranges as the original Stöber process without addition of organic solvents. Using the silica spheres as templates, 3D porous Cu and CuO catalysts with different pore sizes were synthesized in Chapter 3 to study the effect of catalyst pore size on the plasma-catalytic dry reforming. In most cases, the smaller the pore size, the higher the conversion of CH4 and CO2 due to the reaction of radicals and ions formed in the plasma. An exception are the samples synthesized from 1 μm silica, which show better performance due to the electric field enhancement for pore sizes close to the Debye length. Besides the pore size, the particle diameter of the catalyst or packing is also one of the important factors affecting the interaction between plasma and catalyst. In Chapter 4, SiO2 spheres (with or without supported metal) were used to study the effect of different support particle sizes on plasma-based dry reforming. We found that a uniform SiO2 packing improves the conversion of plasma-based dry reforming. The conversion of plasma-based dry reforming first increases and then decreases with increasing particle size, due to the balance between the promoting and hindering effect of the particle filling on the plasma discharge. Chapter 5 is to improve the design of the DBD reactor itself, in order to try to increase its low energy yield. Some stainless steel rings were put over the inner electrode rod of the DBD reactor. The presence of rings increases the local electric field, the displaced charges and the discharge fraction, and also makes the discharge more stable and with more uniform intensity. The placement of the rings improves the performance of the reactor at 30 W supplied power.
Keywords: Doctoral thesis; Engineering sciences. Technology; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Snoeckx R (2017) Plasma technology : a novel solution for CO2 conversion? Antwerpen
Keywords: Doctoral thesis; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Huygh S (2017) Towards a fundamental understanding of plasma : TiO2 catalyst interaction for greenhouse gas conversion. Universiteit Antwerpen, Antwerpen
Keywords: Doctoral thesis; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Ramakers M (2019) Using a gliding arc plasmatron for CO2 conversion : the future in industry? 235 p
Keywords: Doctoral thesis; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|