“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
“The elemental composition of airborne particulate matter in the Atacama desert, Chile”. Rojas CM, Figueroa L, Janssens KH, Van Espen PE, Adams FC, Van Grieken RE, The science of the total environment 91, 251 (1990). http://doi.org/10.1016/0048-9697(90)90302-B
Abstract: Air particulate samples were collected at Chapiquiña near Arica (Chile) with a six-stage cascade impactor for about 17-day periods during a 31 month interval. Sixteen elements were determined by energy dispersive X-ray fluorescence analysis, and the elemental concentrations were subjected to principal factor analysis. The variability with time of the coarse particles was described by two factors both related to soil dispersion, whereas the fine particle variations could be explained by a third factor related to marine influence. Enrichment factors were compared with those obtained in other remote continental areas, in particular those of air particulate matter sampled at Chacaltaya, Bolivia. Results point to a negligible anthropogenic influence.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90302-B
|
“Large-area elemental imaging reveals Van Eyck's original paint layers on the Ghent altarpiece (1432), rescoping its conservation treatment”. van der Snickt G, Dubois H, Sanyova J, Legrand S, Coudray A, Glaude C, Postec M, van Espen P, Janssens K, Angewandte Chemie: international edition in English 56, 4797 (2017). http://doi.org/10.1002/ANIE.201700707
Abstract: A combination of large-scale and micro-scale elemental imaging, yielding elemental distribution maps obtained by, respectively non-invasive macroscopic X-ray fluorescence (MA-XRF) and by secondary electron microscopy/energy dispersive X-ray analysis (SEM-EDX) and synchrotron radiation-based micro-XRF (SR m-XRF) imaging was employed to reorient and optimize the conservation strategy of van Eyck's renowned Ghent Altarpiece. By exploiting the penetrative properties of X-rays together with the elemental specificity offered by XRF, it was possible to visualize the original paint layers by van Eyck hidden below the overpainted surface and to simultaneously assess their condition. The distribution of the high-energy Pb-L and Hg-L emission lines revealed the exact location of hidden paint losses, while Fe-K maps demonstrated how and where these lacunae were filled-up using an iron-containing material. The chemical maps nourished the scholarly debate on the overpaint removal with objective, chemical arguments, leading to the decision to remove all skillfully applied overpaints, hitherto interpreted as work by van Eyck. MA-XRF was also employed for monitoring the removal of the overpaint during the treatment phase. To gather complementary information on the in-depth layer build-up, SEM-EDX and SR mu-XRF imaging was used on paint cross sections to record microscale elemental maps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 11
DOI: 10.1002/ANIE.201700707
|
“Study of the uniformity of aerosol filters by scanning MA-XRF”. Cabal A, Legrand S, Van den Bril B, Tote K, Janssens K, van Espen P, X-ray spectrometry
T2 –, 17th European Conference on X-Ray Spectrometry (EXRS), JUN 19-24, 2016, Univ Gothenburg, Univ Gothenburg, Gothenburg, SWEDEN 46, 461 (2017). http://doi.org/10.1002/XRS.2767
Abstract: Energy-dispersive X-ray fluorescence (XRF) is an attractive analytical method to determine the level of air pollution by heavy metals. The concentration of the filter in ng/cm(2) is obtained by direct comparison of the net characteristic line intensity of an element with that of a thin film standard. As the sampled area on the filter and the area of the standard are larger than the area analysed by the instrument, the distribution of the elements on the surface of both samples and standards have to be sufficiently uniform. If this is not the case, biased concentration estimates are obtained. Two scanning macro-XRF setups with a beam diameter of similar to 0.5 mm were used to investigate the distribution of elements in (1) commercially available (Micromatter) standards, (2) in-house quartz filter standards obtained with an aerosol generator and (3) particulatematter (PM10) collected on quartz filters by a Leckel SEQ 47/50 sampler. The uniformity of the Micromatter standards was better than 2%. At least some in-house standards showed a concave distribution with less material at the edges. The maximum bias introduced by this is less than 5%. Because of the limited sensitivity of scanning XRF compared with conventional XRF, the distribution of only a few common elements like Ca and Fe could be determined reliably in aerosol filters. The distribution of some heavy elements could only be measured in filters sampled in polluted regions. In general, the loading of particulate matter over the filters was uniform. Copyright (C) 2017 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 4
DOI: 10.1002/XRS.2767
|
“Case specific prediction intervals for tri-PLS1 : the full local linearisation”. Serneels S, Faber K, Verdonck T, van Espen PJ, Chemometrics and intelligent laboratory systems 108, 93 (2011). http://doi.org/10.1016/J.CHEMOLAB.2011.05.002
Abstract: A new method to estimate case specific prediction uncertainty for univariate trilinear partial least squares (tri-PLS1) regression is introduced. This method is, from a theoretical point of view, the most exact finite sample approximation to true prediction uncertainty that has been reported up till now. Using the new method, different error sources can be propagated, which is an advantage that cannot be offered by data driven approaches such as the bootstrap. In a concise example, it is illustrated how the method can be applied. In the Appendix, efficient algorithms are presented to compute the estimates required.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHEMOLAB.2011.05.002
|
“DFT study of the hyperfine parameters and magnetic properties of ZnO doped with 57Fe”. Abreu Y, Cruz CM, Pinera I, Leyva A, Cabal AE, van Espen P, Solid state communications 185, 25 (2014). http://doi.org/10.1016/J.SSC.2014.01.010
Abstract: Magnetic state of Fe-57 implanted and doped ZnO samples have been reported and studied by Mossbauer spectroscopy at different temperatures. The Mossbauer spectra mainly showed four doublets and three sextets, but some ambiguous identification remains regarding the probe site location and influence of defects in the hyperfine and magnetic parameters. In the present work some possible implantation configurations are suggested and evaluated using Monte Carlo simulation and electronic structure calculations within the density functional theory. Various implantation environments were proposed and studied considering the presence of defects. The obtained Fe-57 hyperfine parameters show a good agreement with the reported experimental values for some of these configurations. The possibility of Fe pair formation, as well as a Zn site vacancy stabilization between he second and third neighborhood of the implantation site, is supported. (C) 2014 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SSC.2014.01.010
|
“Electric field gradient calculations in ZnO samples implanted with 111In(111Cd)”. Abreu Y, Cruz CM, van Espen P, Pérez C, Piñera I, Leyva A, Cabal AE, Solid state communications 152, 399 (2012). http://doi.org/10.1016/J.SSC.2011.12.001
Abstract: A first-principles study of the electric field gradient (EFG) calculated for ideal and In-111(Cd-111) implanted ZnO samples is reported in the present work. The study was made for ZnO ideal hexagonal structures and supercells were introduced in order to consider the possible implantation environments. The calculation was done using the “WIEN2k” code within the density functional theory, the exchange and correlation effects were determined by the GGA approximation. Three possible In-111(Cd-111) implantation configurations were studied, one substitutional incorporation at cation site and two interstitials. The obtained EFG values for the ideal structure and the substitutional site are in good agreement with the experimental reports measured by perturbed angular correlation (PAC) and high precision nuclear magnetic resonance (NMR). Thus, the ascription of substitutional incorporation of In-111(Cd-111) probe atom at the ZnO cation site after annealing was confirmed. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SSC.2011.12.001
|
“Improved radiographic methods for the investigation of paintings using laboratory and synchrotron X-ray sources”. Schalm O, Cabal A, van Espen P, Laquière N, Storme P, Journal of analytical atomic spectrometry 26, 1068 (2011). http://doi.org/10.1039/C0JA00242A
Abstract: It is generally known that radiographic inspection of 1517th century paintings can easily be done with a polychromatic X-ray source using a voltage between 20 kV and 40 kV in combination with classic X-ray films. Unfortunately, the spatial structure of numerous 19th and early 20th century paintings cannot be visualized with conventional radiography due to several reasons such as the use of lead white grounds or low absorbing pigments. Radiographic images are blurred or worse, they do not contain the picture of the painting. During the last decades, many technological innovations have been introduced in the field of radiography but their possibilities in cultural heritage have not been explored in full detail. In our investigation we used phosphor imaging plates, energy dispersive detectors and CCD-cameras in combination with synchrotron radiation and conventional X-ray tubes in order to improve the quality of radiographic images. Several promising techniques that could improve the quality of radiographs of paintings were identified.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/C0JA00242A
|
“Monitoring of tropospheric ozone in the ambient air with passive samplers”. Alejo ellys, Morales MC, Nuñez V, Bencs L, Van Grieken R, van Espen P, Microchemical journal 99, 383 (2011). http://doi.org/10.1016/J.MICROC.2011.06.010
Abstract: Two sampling campaigns in suburban places in the north zone of Santa Clara city, Cuba, have been carried out on a weekly base with the use of Radiello passive diffusion tubes in order to monitor the tropospheric ozone (O3) levels in 2010. The first campaign was scheduled from February to April (cold season) and the second one in August and October (warm season), both of them at two sampling sites, i.e., Farm and School of Art Instructors. After aqueous extraction, the samples were analyzed by UVVIS spectrophotometry. A seasonal trend was observed with the maximum O3 concentrations in the cold season and the minimum levels in the warm season. Samples collected during the cold season showed the highest O3 levels. Higher levels were reached at the Farm site with average values of about 58 ± 12 μg/m3, which exceeded the limit of the Cuban Standard 99:1999. In the warm season, the O3 concentrations were similar for both sites, but lower than those observed in the cold season. The overall, seasonal average value was found to be 24 μg/m3. Despite the higher weekly average temperatures in August, the O3 concentrations during this month showed the lowest values of the whole sampling period, which finding is in agreement with that reported by the Meteorological Institute of Cuba. Mathematical models, based on the Cochrane-Orcutt algorithm, were fitted to the acquired data set to explain the change in the tropospheric ozone concentrations under various meteorological conditions during the two campaigns. The correlation coefficients for both the cold and the warm seasons demonstrated a strong correlation, i.e., 0.779 and 0.951, respectively. The high correlation of wind speed in the model from the first sampling campaign explains the sharp decrease in O3 concentrations at the SAI sampling site from the sixth week of sampling.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2011.06.010
|
“Monte Carlo simulation of X-ray spectra from low energy electrons using optical data”. Roet D, van Espen P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 268, 2794 (2010). http://doi.org/10.1016/J.NIMB.2010.07.004
Abstract: An approach using optical data to simulate both the bremsstrahlung continuum and characteristic K and L X-ray lines generated by low energy electrons (cfr. electron microscopy) in solids is discussed in this paper. The necessary analytical expressions together with the data to calculate the relevant cross sections for elastic and inelastic interactions at these energies along with variance reduction techniques are given. The results of the Monte Carlo simulation are compared to experimental data measured with a JEOL 6300 electron microscope.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2010.07.004
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
“Seasonal trends of atmospheric nitrogen dioxide and sulfur dioxide over North Santa Clara, Cuba”. Alejo D, Morales MC, de la Torre JB, Grau R, Bencs L, Van Grieken R, van Espen P, Sosa D, Nuñez V, Environmental monitoring and assessment 185, 6023 (2013). http://doi.org/10.1007/S10661-012-3003-4
Abstract: Atmospheric nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels were monitored simultaneously by means of Radiello passive samplers at six sites of Santa Clara city, Cuba, in the cold and the warm seasons in 2010. The dissolved ionic forms of NO2 and SO2 as nitrate and sulfite plus sulfate, respectively, were determined by means of ion chromatography. Analysis of NO2 as nitrite was also performed by UVVis spectrophotometry. For NO2, significant t tests show good agreement between the results of IC and UVVis methods. The NO2 and SO2 concentrations peaked in the cold season, while their minimum levels were experienced in the warm season. The pollutant levels do not exceed the maximum allowable limit of the Cuban Standard 39:1999, i.e., 40 μg/m3 and 50 μg/m3 for NO2 and SO2, respectively. The lowest pollutant concentrations obtained in the warm season can be attributed to an increase in their removal via precipitation (scavenging) while to the decreased traffic density and industrial emission during the summer holidays (e.g., July and August).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-012-3003-4
|
“Comparison of x-ray absorption and emission techniques for the investigation of paintings”. Cabal A, Schalm O, Eyskens P, Willems P, Harth A, van Espen P, X-ray spectrometry 44, 141 (2015). http://doi.org/10.1002/XRS.2591
Abstract: Four x-ray techniques: computed radiography, emission radiography, energy-resolved radiography and imaging x-ray fluorescence were compared using four mock-up panel paintings. The paintings have different stratigraphy and pigments and are representative for different historical periods. One of the paintings has a hidden underlying painting. The type of pigments used mainly influences the information obtained by both the emission and absorption measurements; high-Z white pigment and high-Z color pigments giving the best contrast. Each of the techniques revealed interesting aspects of the paintings, but none of them could reveal the hidden painting to a satisfactory level. Due to the statistical quality of the spectral data, x-ray fluorescence gives elemental images with high contrast. The radiographic images are better to reveal the internal structure. Imaging x-ray fluorescence and energy-resolved radiography measurements can be done simultaneously, and the combination has the highest potential for the study of complex multilayer paintings. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1002/XRS.2591
|
“Study of a unique 16th century Antwerp majolica floor in the Rameyenhof castle's chapel by means of X-ray fluorescence and portable Raman analytical instrumentation”. Van de Voorde L, Vandevijvere M, Vekemans B, Van Pevenage J, Caen J, Vandenabeele P, van Espen P, Vincze L, Spectrochimica acta: part B : atomic spectroscopy 102, 28 (2014). http://doi.org/10.1016/J.SAB.2014.10.007
Abstract: The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles – an element that was not used for making 16th century majolica – valuable information about the originality of the chapel floor and the two central medallions is acquired. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.SAB.2014.10.007
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|
“Analysis of X-ray spectra by iterative least squares (AXIL): new developments”. Vekemans B, Janssens K, Vincze L, Adams F, van Espen P, X-ray spectrometry 23, 278 (1994). http://doi.org/10.1002/XRS.1300230609
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300230609
|
“AXIL-PC, software for the analysis of complex-x-ray spectra”. van Espen P, Janssens K, Nobels J, Chemometrics and intelligent laboratory systems 1, 109 (1986). http://doi.org/10.1016/0169-7439(86)80031-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(86)80031-4
|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
“Increased accuracy in the automated interpretation of large epma data sets by the use of an expert system”. Janssens K, Vanborm W, van Espen P, Journal of research of the National Bureau of Standards (1934) 93, 260 (1988). http://doi.org/10.6028/JRES.093.037
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.6028/JRES.093.037
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
“Quantitative analysis of 16-17th century archaeological glass vessels using PLS regression of EPXMA and μ-XRF data”. Lemberge P, Deraedt I, Janssens K, van Espen P, Journal of chemometrics 14, 751 (2000). http://doi.org/10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 1.884
DOI: 10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
|
“Semiempirical approach for standardless calibration in µ-XRF spectrometry using capillary lenses”. Padilla R, van Espen P, Abrahantes A, Janssens K, X-ray spectrometry 34, 19 (2005). http://doi.org/10.1002/XRS.781
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 1.298
Times cited: 23
DOI: 10.1002/XRS.781
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
“Characterization of individual soot aggregates from different sources using image analysis”. Smekens A, Godoi RHM, Vervoort M, van Espen P, Potgieter-Vermaak SS, Van Grieken R, Journal of atmospheric chemistry 56, 211 (2007). http://doi.org/10.1007/S10874-006-9050-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1007/S10874-006-9050-X
|
“Classification of coal mine dust particles through fuzzy clustering of their energy-dispersive electron microprobe X-ray spectra”. Bondarenko I, van Espen P, Treiger B, Van Grieken R, Adams F, Microbeam analysis 3, 33 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Classification of mineral particles by nonlinear mapping of electron microprobe energy-dispersive X-ray spectra”. Treiger B, Bondarenko I, van Espen P, Van Grieken R, Adams F, The analyst 119, 971 (1994). http://doi.org/10.1039/AN9941900971
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1039/AN9941900971
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|