“Optimization of operating parameters for inductively coupled plasma mass spectrometry : a computational study”. Aghaei M, Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 76, 56 (2012). http://doi.org/10.1016/j.sab.2012.06.006
Abstract: An inductively coupled plasma, connected to a mass spectrometer interface, is computationally investigated. The effect of pressure behind the sampler, injector gas flow rate, auxiliary gas flow rate, and applied power is studied. There seems to be an optimum range of injector gas flow rate for each setup which guaranties the presence and also a proper length of the central channel in the torch. Moreover, our modeling results show that for any specific purpose, it is possible to control that either only the central gas flow passes through the sampler orifice or that it is accompanied by the auxiliary gas flow. It was also found that depending on geometry, the variation of outgoing gas flow rate is much less than the variation of the injector gas flow rate and this causes a slightly higher pressure inside the torch. The general effect of increasing the applied power is a rise in the plasma temperature, which results in a higher ionization in the coil region. However, the negative effect is reducing the length of the cool central channel which is important to transfer the sample substances to the sampler. Using a proper applied power can enhance the efficiency of the system. Indeed, by changing the gas path lines, the power can control which flow (i.e., only from injector gas or also from the auxiliary gas) goes to the sampler orifice. Finally, as also reported from experiments in literature, the pressure behind the sampler has no dramatic effect on the plasma characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 18
DOI: 10.1016/j.sab.2012.06.006
|
“Organic SIMS: the influence of time on the ion yield enhancement by silver and gold deposition”. Adriaensen L, Vangaever F, Gijbels R, Applied surface science 231/232, 256 (2004). http://doi.org/10.1016/j.apsusc.2004.03.031
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 10
DOI: 10.1016/j.apsusc.2004.03.031
|
“Organische TOF-S-SIMS: gebruik van opgedampt Ag en Au voor de verhoging van secundaire ionenintensiteiten”. Adriaensen L, Vangaever F, Gijbels R, Chemie magazine , 10 (2004)
Keywords: A2 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Parametric study by means of numerical modelling for a dielectric barrier discharge at atmospheric pressure in nitrogen”. Madani M, Bogaerts A, Gijbels R, Vangeneugden D, , 49 (2004)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Particle-in-cell/Monte Carlo collisions treatment of an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx films”. Bultinck E, Bogaerts A, New journal of physics 11, 103010 (2009). http://doi.org/10.1088/1367-2630/11/10/103010
Abstract: The physical processes in an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx thin films were simulated with a 2d3v particle-in-cell/Monte Carlo collisions (PIC/MCC) model. The plasma species taken into account are electrons, Ar+ ions, fast Arf atoms, metastable Arm* atoms, Ti+ ions, Ti atoms, O+ ions, O2+ ions, O− ions and O atoms. This model accounts for plasmatarget interactions, such as secondary electron emission and target sputtering, and the effects of target poisoning. Furthermore, the deposition process is described by an analytical surface model. The influence of the O2/Ar gas ratio on the plasma potential and on the species densities and fluxes is investigated. Among others, it is shown that a higher O2 pressure causes the region of positive plasma potential and the O− density to be more spread, and the latter to decrease. On the other hand, the deposition rates of Ti and O are not much affected by the O2/Ar proportion. Indeed, the predicted stoichiometry of the deposited TiOx film approaches x=2 for nearly all the investigated O2/Ar proportions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 24
DOI: 10.1088/1367-2630/11/10/103010
|
“Particle-in-cell Monte Carlo modeling of Langmuir probes in an Ar plasma”. Cenian A, Chernukho A, Bogaerts A, Gijbels R, Leys C, Journal of applied physics 97, 123310 (2005). http://doi.org/10.1063/1.1938275
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 18
DOI: 10.1063/1.1938275
|
“Particle-in-cell/Monte Carlo simulation of a capacitively coupled radio frequency Ar/Cf4 discharge: effect of gas composition”. Georgieva V, Bogaerts A, Gijbels R, Journal of applied physics 93, 2369 (2003). http://doi.org/10.1063/1.1542920
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 57
DOI: 10.1063/1.1542920
|
“Particle-in-cell/Monte Carlo simulations of a low-pressure capacitively coupled radio-frequency discharge: effect of adding H2 to an Ar discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Journal of applied physics 93, 5025 (2003). http://doi.org/10.1063/1.1563820
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 15
DOI: 10.1063/1.1563820
|
“Photographic materials”. Verlinden G, Gijbels R, Geuens I Surface Spectra IM, Chichester, page 727 (2001).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Physics of generation and detection of signals used for microcharacterization”. Remond G, Gijbels R, Levenson LL, Shimizu R Scanning Microscopy International, Chicago, Ill. (1994).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“PIC-MC simulation of an RF capacitively coupled Ar/H2 discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Nuclear instruments and methods in physics research: B 202, 300 (2003). http://doi.org/10.1016/S0168-583X(02)01873-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 8
DOI: 10.1016/S0168-583X(02)01873-6
|
“Plasma characteristics of an Ar/CF4/N2 discharge in an asymmetric dual frequency reactor: numerical investigation by a PIC/MC model”. Georgieva V, Bogaerts A, Plasma sources science and technology 15, 368 (2006). http://doi.org/10.1088/0963-0252/15/3/010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 35
DOI: 10.1088/0963-0252/15/3/010
|
Van Gaens W (2014) Plasma chemistry modelling of an atmospheric pressure argon plasma jet with air impurities for plasma medicine applications. Antwerpen
Keywords: Doctoral thesis; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Plasma diagnostics of an analytical Grimm-type glow discharge in argon and in neon: Langmuir probe and optical emission spectroscopy measurements”. Bogaerts A, Quentmeier A, Jakubowski N, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 1337 (1995). http://doi.org/10.1016/0584-8547(95)01356-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 37
DOI: 10.1016/0584-8547(95)01356-5
|
“Plasma enhanced growth of single walled carbon nanotubes at low temperature : a reactive molecular dynamics simulation”. Shariat M, Hosseini SI, Shokri B, Neyts EC, Carbon 65, 269 (2013). http://doi.org/10.1016/j.carbon.2013.08.025
Abstract: Low-temperature growth of carbon nanotubes (CNTs) has been claimed to provide a route towards chiral-selective growth, enabling a host of applications. In this contribution, we employ reactive molecular dynamics simulations to demonstrate how plasma-based deposition allows such low-temperature growth. We first show how ion bombardment during the growth affects the carbon dissolution and precipitation process. We then continue to demonstrate how a narrow ion energy window allows CNT growth at 500 K. Finally, we also show how CNTs in contrast cannot be grown in thermal CVD at this low temperature, but only at high temperature, in agreement with experimental data. (C) 2013 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.337
Times cited: 21
DOI: 10.1016/j.carbon.2013.08.025
|
“Plasma models”. Bogaerts A, Gijbels R Wiley, New York, page 176 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Preconcentration of precious metals by tellurium sulphide fire-assay followed by instrumental neutron activation analysis”. Shazali I, Van 't dack L, Gijbels R, , 29 (1988)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Quantitative analysis of individual AgxAuy nanoparticles by TEM-EDX: track 1”. de Vyt A, Gijbels R, van Roost C, Geuens I, , 524 (1998)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Quantitative determination of C60 and C70 in soot extracts by high performance liquid chromatography and mass spectrometric characterization”. van Cleempoel A, Gijbels R, Zhu D, Claeys M, Richter H, Fonseca A, Fullerene science and technology 4, 1001 (1996). http://doi.org/10.1080/10641229608001158
Abstract: A quantitative HPLC method was applied to determine the amounts of C-60 and C-70 present in extracts of soot produced in the electric arc reactor and in flames. The combustion method was found to yield a higher C-70/C-60 ratio (0.67) compared with the evaporation experiment where the C-70/C-60 ratio amounts to 0.27.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.836
Times cited: 6
DOI: 10.1080/10641229608001158
|
“Quantitative secondary ion mass spectrometry depth profiling of surface layers of cubic silver halide microcrystals”. Verlinden G, Gijbels R, Geuens I, Journal of the American Society for Mass Spectrometry 10, 1016 (1999). http://doi.org/10.1016/S1044-0305(99)00064-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.786
Times cited: 4
DOI: 10.1016/S1044-0305(99)00064-1
|
“Quantitative SIMS analysis of surface layers of cubic silver halide microcrystals: comparison of different quantification methods”. Verlinden G, Gijbels R, Geuens I, , 995 (1998)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Quantitative surface analysis of silver halide microcrystals using scanning ion microprobe and scanning Auger microprobe”. Janssens G, Geuens I, de Keyzer R, van Espen P, Gijbels R, Hubin A, Terryn H, Vereecken J Wiley, Chichester, page 161 (1996).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
|
“Quantum simulations of electrostatics in Si cylindrical junctionless nanowire nFETs and pFETs with a homogeneous channel including strain and arbitrary crystallographic orientations”. Pham A-T, Sorée B, Magnus W, Jungemann C, Meinerzhagen B, Pourtois G, Solid state electronics 71, 30 (2012). http://doi.org/10.1016/j.sse.2011.10.016
Abstract: Simulation results of electrostatics in Si cylindrical junctionless nanowire transistors with a homogenous channel are presented. Junctionless transistors including strain and arbitrary crystallographic orientations are studied. Size quantization effects are simulated by self-consistent solutions of the Poisson and Schrodinger equations. The 6 x 6 k.p method is employed for the calculation of the valence subband structure in a junctionless nanowire pFET. The influence of stress/strain and crystallographic channel orientation on to the electrostatics in terms of subband structure, charge density, and C-V curve is systematically studied. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.58
Times cited: 2
DOI: 10.1016/j.sse.2011.10.016
|
“Reaction mechanisms and thin a-C:H film growth from low energy hydrocarbon radicals”. Neyts E, Bogaerts A, van de Sanden MCM, Journal of physics : conference series 86, 12020 (2007). http://doi.org/10.1088/1742-6596/86/1/012020
Abstract: Molecular dynamics simulations using the Brenner potential have been performed to investigate reaction mechanisms of various hydrocarbon radicals with low kinetic energies on amorphous hydrogenated carbon (a-C:H) surfaces and to simulate thin a-C:H film growth. Experimental data from an expanding thermal plasma setup were used as input for the simulations. The hydrocarbon reaction mechanisms were studied both during growth of the films and on a set of surface sites specific for a-C:H surfaces. Thin film growth was studied using experimentally detected growth species. It is found that the reaction mechanisms and sticking coefficients are dependent on the specific surface sites, and the structural properties of the growth radicals. Furthermore, it is found that thin a-C:H films can be densified using an additional H-flux towards the substrate.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 22
DOI: 10.1088/1742-6596/86/1/012020
|
“Reactions of high FeO-olivine rock with groundwater and redox-sensitive elements studied by surface-analytical methods and autoradiography”. Hellmuth KH, Siitari-Kaupi M, Rauhala E, Johansson B, Zilliacus R, Gijbels R, Adriaens A, Materials Research Society symposium proceedings 333, 947 (1994)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 6
|
“Reactive sputter deposition of TiNx films, simulated with a particle-in-cell/Monte Carlo collisions model”. Bultinck E, Mahieu S, Depla D, Bogaerts A, New journal of physics 11, 023039 (2009). http://doi.org/10.1088/1367-2630/11/2/023039
Abstract: The physical processes in an Ar/N2 magnetron discharge used for the reactive sputter deposition of TiNx thin films were simulated with a 2d3v particle-in-cell/Monte Carlo collisions (PIC/MCC) model. Cathode currents and voltages were calculated self-consistently and compared with experiments. Also, ion fractions were calculated and validated with mass spectrometric measurements. With this PIC/MCC model, the influence of N2/Ar gas ratio on the particle densities and fluxes was investigated, taking into account the effect of the poisoned state of the target.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 23
DOI: 10.1088/1367-2630/11/2/023039
|
“Recent trends in solids mass spectrometry: GDMS and other methods”. Gijbels R, Bogaerts A, Fresenius' journal of analytical chemistry 359, 326 (1997). http://doi.org/10.1007/s002160050581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1007/s002160050581
|
“Recent trends in solids mass spectrometry, with special emphasis on glow discharge mass spectrometry”. Gijbels R, Bogaerts A, , 71 (1996)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Recherches microchimiques comparatives (SME et AAN) d'hydrothermes des granites de la Bulgarie du Sud”. Pentcheva EN, Swenters K, Van 't dack L, Verlinden J, Gijbels R, Doklady Bolgarskoi Akademii Nauk 37, 509 (1984)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Reduction of composite Ag(Br,I) grains as studied by AEM and digital image analysis techniques”. Oleshko VP, Gijbels RH, Jacob WA, , 657 (1998)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|