|
“Comparison of strained SiGe heterostructure-on-insulator (0 0 1) and (1 1 0) PMOSFETs : CV characteristics, mobility, and ON current”. Pham A-T, Zhao Q-T, Jungemann C, Meinerzhagen B, Mantl S, Sorée B, Pourtois G, Solid state electronics 65-66, 64 (2011). http://doi.org/10.1016/j.sse.2011.06.021
Abstract: Strained SiGe heterostructure-on-insulator (0 0 1) and (1 1 0) PMOSFETs are investigated including important aspects like CV characteristics, mobility, and ON current. The simulations are based on the self-consistent solution of 6 × 6 k · p Schrödinger Equation, multi subband Boltzmann Transport Equation and Poisson Equation, and capture size quantization, strain, crystallographic orientation, and SiGe alloy effects on a solid physical basis. The simulation results are validated by comparison with different experimental data sources. The simulation results show that the strained SiGe HOI PMOSFET with (1 1 0) surface orientation has a higher gate capacitance and a much higher mobility and ON current compared to a similar device with the traditional (0 0 1) surface orientation.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.58
Times cited: 2
DOI: 10.1016/j.sse.2011.06.021
|
|
|
“Complex structural and analytical characterization of silver halide photographic systems by means of analytical electron microscopy”. Oleshko V, Gijbels R, Jacob W, Alfimov M Editions de physique, Les Ulis, page 701 (1994).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Comprehensive description of a Grimm-type glow discharge source used for optical emission spectrometry: a mathematical simulation”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 437 (1998). http://doi.org/10.1016/S0584-8547(97)00148-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 46
DOI: 10.1016/S0584-8547(97)00148-1
|
|
|
“Comprehensive modelling network for dc glow discharges in argon”. Bogaerts A, Plasma sources science and technology 8, 210 (1999). http://doi.org/10.1088/0963-0252/8/2/003
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 27
DOI: 10.1088/0963-0252/8/2/003
|
|
|
“Comprehensive three-dimensional modeling network for a dc glow discharge plasma”. Bogaerts A, Gijbels R, Plasma physics reports 24, 573 (1998)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.984
Times cited: 8
|
|
|
Aghaei M (2014) Computational study of inductively coupled plasma mass spectroscopy (ICP-MS). Antwerpen
Keywords: Doctoral thesis; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Setareh M (2014) Computational study of CH4 and CF4 conversion in presence of N2 and O2 in plasma discharges applied. Antwerpen
Keywords: Doctoral thesis; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Computer simulation of an analytical direct current glow discharge in argon: influence of the cell dimensions on the plasma quantities”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 12, 751 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
|
|
|
“Computer simulations of argon-hydrogen Grimm-type glow discharges”. Bogaerts A, Journal of analytical atomic spectrometry 23, 1476 (2008). http://doi.org/10.1039/b810599e
Abstract: Computer simulations have been performed to describe the effect of small admixtures of hydrogen to an argon glow discharge in the Grimm-type configuration. The two-dimensional density profiles of the various plasma species (i.e., electrons, Ar+, ArH+, H+, H2+ and H3+ ions, H atoms and H2 molecules, Ar metastable atoms and sputtered Cu atoms) are presented for 1% H2 added to the argon glow discharge, and the effect of different H2 additions (varying between 0.1 and 10%) on the species densities, the hydrogen dissociation degree, and the sputtering process, are investigated. Finally, the relative contributions of various production and loss processes for the different plasma species are calculated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b810599e
|
|
|
“Computer simulations of crater profiles in glow discharge optical emission spectrometry: comparison with experiments and investigation of the underlying mechanisms”. Bogaerts A, Verscharen W, Steers E, Spectrochimica acta: part B : atomic spectroscopy 59, 1403 (2004). http://doi.org/10.1016/j.sab.2004.06.005
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 14
DOI: 10.1016/j.sab.2004.06.005
|
|
|
“Computer simulations of laser ablation, plume expansion and plasma formation”. Bogaerts A, Aghaei M, Autrique D, Lindner H, Chen Z, Wendelen W Trans Tech, Aedermannsdorf, page 1 (2011).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 8
DOI: 10.4028/www.scientific.net/AMR.227.1
|
|
|
“A critical comparison of MINDO/3, MNDO, AM1 and PM3 for a model problem: carbon clusters C2-C10. An ad hoc reparametrization of MNDO well suited for the accurate prediction of their spectroscopic constants”. Martin JML, François JP, Gijbels R, Journal of computational chemistry 12, 52 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.589
Times cited: 76
|
|
|
“Cryo-analytical electron microscopy: new insight into understanding of crystalline and electronic structure of silver halides”. Oleshko V, Gijbels R, Jacob W Spie, Washington, D.C., page 326 (1998).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
|
|
|
“Cryo-electron spectroscopic imaging, electron energy-loss spectroscopy and energy-dispersive X-ray analysis of Ag(Br,I) nano- and microcrystals”. Oleshko V, Gijbels R, Jacob W, van Daele A, Mikrochimica acta: supplementum 15, 87 (1998)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Depth profiling of coated steel wires by GDMS”. van Straaten M, Butaye L, Gijbels R, , 629 (1992)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Depth profiling of silver halide microcrystals”. Geuens I, Gijbels R, Jacob W, Verbeeck A, de Keyzer R, , 479 (1992)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Depth profiling of silver halide microcrystals”. Geuens I, Gijbels R, Jacob W, , 479 (1991)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Depth profiling of ZrO2/SiO2/Si stacks : a TOF-SIMS and computer simulation study”. Ignatova VA, Conard T, Möller W, Vandervorst W, Gijbels R, Applied surface science 231/232, 603 (2004). http://doi.org/10.1016/j.apsusc.2004.03.121
Abstract: This study is dedicated to a better understanding of the processes occurring under ion bombardment of ultra-thin ZrO2/SiO2/Si gate dielectric stacks. Complex-shaped depth profiles were obtained by using TOF-SIMS with dual beam (500 eV for sputtering and 10 keV for analysis) Ar+ ions. The SIMS intensities of all the elements depend critically on the amount of oxygen at any moment of the sputtering process. Increased intensity is observed at the surface and at the ZrO2/SiO2 interface. A long tail of the Zr signal is present in the Si substrate, even after the second (SiO2/Si) interface, and a double bump structure in the Zr-90 and ZrO dimer is observed, which is more pronounced with increasing thickness of the interfacial SiO2 layer. Computer simulations using the dynamic Monte Carlo code (TRIDYN) are performed in order to distinguish the ion bombardment-induced effects from changes in the ionization degree. The original code is extended with simple models for the ionization mechanism and for the molecular yield during sputtering. Oxygen preferential sputtering at the surface and ballistic transport of Zr towards and through the interface are clearly demonstrated, but there is also evidence that due to recoil implantation oxygen gets piled-up near the ZrO2/SiO2 interface. (C) 2004 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 4
DOI: 10.1016/j.apsusc.2004.03.121
|
|
|
“Description of the argon-excited levels in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 263 (2000). http://doi.org/10.1016/S0584-8547(00)00143-9
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 24
DOI: 10.1016/S0584-8547(00)00143-9
|
|
|
“Description of the plasma chemistry in an atmospheric pressure CH4 dielectric barrier discharge using a two dimensional fluid model”. De Bie C, Martens T, van Dijk J, van der Mullen JJAM, Bogaerts A, , 13 (2009)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Description of the thermalization process of the sputtered atoms in a glow discharge using a 3-dimensional Monte Carlo method”. Bogaerts A, van Straaten M, Gijbels R, Journal of applied physics 77, 1868 (1995). http://doi.org/10.1063/1.358887
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 87
DOI: 10.1063/1.358887
|
|
|
“Design and development of a new program for data processing of mass spectra acquired by means of a high-resolution double-focusing glow-discharge mass spectrometer”. Robben J, Dufour D, Gijbels R, Fresenius' journal of analytical chemistry 370, 663 (2001). http://doi.org/10.1007/s002160100881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
DOI: 10.1007/s002160100881
|
|
|
“Desorption-ionization of organic compounds studied by Fourier transform laser microprobe mass spectrometry”. van Roy W, Struyf H, van Vaeck L, Gijbels R, Caravatti P, Rapid communications in mass spectrometry 8, 40 (1994). http://doi.org/10.1002/rcm.1290080108
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.253
Times cited: 5
DOI: 10.1002/rcm.1290080108
|
|
|
“Determination of gold at the ultratrace level in natural waters”. Cidu R, Fanfani L, Shaud P, Edmunds WM, Van 't dack L, Gijbels R, Analytica chimica acta 296, 295 (1994). http://doi.org/10.1016/0003-2670(94)80249-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 20
DOI: 10.1016/0003-2670(94)80249-1
|
|
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“Determination of scandium in high-purity titanium using inductively coupled plasma mass spectrometry and glow discharge mass spectrometry as part of its certification as a reference material”. Held A, Taylor P, Ingelbrecht C, de Bièvre P, Broekaert J, van Straaten M, Gijbels R, Journal of analytical atomic spectrometry 10, 849 (1995). http://doi.org/10.1039/ja9951000849
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 6
DOI: 10.1039/ja9951000849
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Determination of the silver sulphide cluster size distribution via computer simulations”. Charlier E, Gijbels R, Van Doorselaer M, De Keyzer R page 85 (2000).
Abstract: Addition of a labile sulphur donor to light sensitive silver halide microcrystals results in the formation of a distribution of silver sulphide clusters on the crystal surface. These silver sulphide clusters enhance the efficiency of image formation during the photographic process. Their activity towards the capturing of light photons, however, is very critical to their size (aggregation number) and concentration. By incorporating gold ions into silver sulphide clusters it was possible to monitor the size distribution by measuring the amount of gold reacted. From these experiments, no evidence was found for aggregation of the reacted sulphur entities on the surface. The uptake of gold ions at different sulphur concentrations could well be fitted with a simulated size distribution when a catalyzed deposition of sulphur was assumed, with a reactivity of the surface equal to 1.0 % for the microcrystals studied. From a simulation of the silver sulphide cluster size distribution a correlation could also be found between increasing aggregation numbers and the absorption at increasing wavelengths in diffuse reflectance spectroscopy.
Keywords: H1 Book chapter; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Development of a Fourier transform laser microprobe mass spectrometer with external ion source”. Gijbels R, ICR/Ion trap newsletter 30 (1993)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|