“Numerical study of Ar/CF4/N2 discharges in single and dual frequency capacitively coupled plasma reactors”. Georgieva V, Bogaerts A, Gijbels R, Journal of applied physics 94, 3748 (2003). http://doi.org/10.1063/1.1603348
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 90
DOI: 10.1063/1.1603348
|
|
|
“Numerical study on energy efficiency of a cylindrical dielectric barrier discharge plasma-chemical reactor”. Petrovic D, Martens T, De Bie C, van Dijk J, Brok WJM, Bogaerts A, , 109 (2009)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“On the reaction behaviour of hydrocarbon species at diamond (1 0 0) and (1 1 1) surfaces: a molecular dynamics investigation”. Eckert M, Neyts E, Bogaerts A, Journal of physics: D: applied physics 41, 032006 (2008). http://doi.org/10.1088/0022-3727/41/3/032006
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
Times cited: 17
DOI: 10.1088/0022-3727/41/3/032006
|
|
|
“A one-dimensional fluid model for an acetylene rf discharge: a study of the plasma chemistry”. Herrebout D, Bogaerts A, Gijbels R, Goedheer WJ, Vanhulsel A, IEEE transactions on plasma science 31, 659 (2003). http://doi.org/10.1109/TPS.2003.815249
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 26
DOI: 10.1109/TPS.2003.815249
|
|
|
“One-dimensional modelling of a capacitively coupled rf plasma in silane/helium, including small concentrations of O2 and N2”. de Bleecker K, Herrebout D, Bogaerts A, Gijbels R, Descamps P, Journal of physics: D: applied physics 36, 1826 (2003)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.588
|
|
|
“Optimization of operating parameters for inductively coupled plasma mass spectrometry : a computational study”. Aghaei M, Lindner H, Bogaerts A, Spectrochimica acta: part B : atomic spectroscopy 76, 56 (2012). http://doi.org/10.1016/j.sab.2012.06.006
Abstract: An inductively coupled plasma, connected to a mass spectrometer interface, is computationally investigated. The effect of pressure behind the sampler, injector gas flow rate, auxiliary gas flow rate, and applied power is studied. There seems to be an optimum range of injector gas flow rate for each setup which guaranties the presence and also a proper length of the central channel in the torch. Moreover, our modeling results show that for any specific purpose, it is possible to control that either only the central gas flow passes through the sampler orifice or that it is accompanied by the auxiliary gas flow. It was also found that depending on geometry, the variation of outgoing gas flow rate is much less than the variation of the injector gas flow rate and this causes a slightly higher pressure inside the torch. The general effect of increasing the applied power is a rise in the plasma temperature, which results in a higher ionization in the coil region. However, the negative effect is reducing the length of the cool central channel which is important to transfer the sample substances to the sampler. Using a proper applied power can enhance the efficiency of the system. Indeed, by changing the gas path lines, the power can control which flow (i.e., only from injector gas or also from the auxiliary gas) goes to the sampler orifice. Finally, as also reported from experiments in literature, the pressure behind the sampler has no dramatic effect on the plasma characteristics.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 18
DOI: 10.1016/j.sab.2012.06.006
|
|
|
“Parametric study by means of numerical modelling for a dielectric barrier discharge at atmospheric pressure in nitrogen”. Madani M, Bogaerts A, Gijbels R, Vangeneugden D, , 49 (2004)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Particle-in-cell/Monte Carlo collisions treatment of an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx films”. Bultinck E, Bogaerts A, New journal of physics 11, 103010 (2009). http://doi.org/10.1088/1367-2630/11/10/103010
Abstract: The physical processes in an Ar/O2 magnetron discharge used for the reactive sputter deposition of TiOx thin films were simulated with a 2d3v particle-in-cell/Monte Carlo collisions (PIC/MCC) model. The plasma species taken into account are electrons, Ar+ ions, fast Arf atoms, metastable Arm* atoms, Ti+ ions, Ti atoms, O+ ions, O2+ ions, O− ions and O atoms. This model accounts for plasmatarget interactions, such as secondary electron emission and target sputtering, and the effects of target poisoning. Furthermore, the deposition process is described by an analytical surface model. The influence of the O2/Ar gas ratio on the plasma potential and on the species densities and fluxes is investigated. Among others, it is shown that a higher O2 pressure causes the region of positive plasma potential and the O− density to be more spread, and the latter to decrease. On the other hand, the deposition rates of Ti and O are not much affected by the O2/Ar proportion. Indeed, the predicted stoichiometry of the deposited TiOx film approaches x=2 for nearly all the investigated O2/Ar proportions.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 24
DOI: 10.1088/1367-2630/11/10/103010
|
|
|
“Particle-in-cell Monte Carlo modeling of Langmuir probes in an Ar plasma”. Cenian A, Chernukho A, Bogaerts A, Gijbels R, Leys C, Journal of applied physics 97, 123310 (2005). http://doi.org/10.1063/1.1938275
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 18
DOI: 10.1063/1.1938275
|
|
|
“Particle-in-cell/Monte Carlo simulation of a capacitively coupled radio frequency Ar/Cf4 discharge: effect of gas composition”. Georgieva V, Bogaerts A, Gijbels R, Journal of applied physics 93, 2369 (2003). http://doi.org/10.1063/1.1542920
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 57
DOI: 10.1063/1.1542920
|
|
|
“Particle-in-cell/Monte Carlo simulations of a low-pressure capacitively coupled radio-frequency discharge: effect of adding H2 to an Ar discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Journal of applied physics 93, 5025 (2003). http://doi.org/10.1063/1.1563820
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 15
DOI: 10.1063/1.1563820
|
|
|
“PIC-MC simulation of an RF capacitively coupled Ar/H2 discharge”. Neyts E, Yan M, Bogaerts A, Gijbels R, Nuclear instruments and methods in physics research: B 202, 300 (2003). http://doi.org/10.1016/S0168-583X(02)01873-6
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 8
DOI: 10.1016/S0168-583X(02)01873-6
|
|
|
“Plasma characteristics of an Ar/CF4/N2 discharge in an asymmetric dual frequency reactor: numerical investigation by a PIC/MC model”. Georgieva V, Bogaerts A, Plasma sources science and technology 15, 368 (2006). http://doi.org/10.1088/0963-0252/15/3/010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 35
DOI: 10.1088/0963-0252/15/3/010
|
|
|
“Plasma diagnostics of an analytical Grimm-type glow discharge in argon and in neon: Langmuir probe and optical emission spectroscopy measurements”. Bogaerts A, Quentmeier A, Jakubowski N, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 1337 (1995). http://doi.org/10.1016/0584-8547(95)01356-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 37
DOI: 10.1016/0584-8547(95)01356-5
|
|
|
“Plasma models”. Bogaerts A, Gijbels R Wiley, New York, page 176 (1997).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Reaction mechanisms and thin a-C:H film growth from low energy hydrocarbon radicals”. Neyts E, Bogaerts A, van de Sanden MCM, Journal of physics : conference series 86, 12020 (2007). http://doi.org/10.1088/1742-6596/86/1/012020
Abstract: Molecular dynamics simulations using the Brenner potential have been performed to investigate reaction mechanisms of various hydrocarbon radicals with low kinetic energies on amorphous hydrogenated carbon (a-C:H) surfaces and to simulate thin a-C:H film growth. Experimental data from an expanding thermal plasma setup were used as input for the simulations. The hydrocarbon reaction mechanisms were studied both during growth of the films and on a set of surface sites specific for a-C:H surfaces. Thin film growth was studied using experimentally detected growth species. It is found that the reaction mechanisms and sticking coefficients are dependent on the specific surface sites, and the structural properties of the growth radicals. Furthermore, it is found that thin a-C:H films can be densified using an additional H-flux towards the substrate.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 22
DOI: 10.1088/1742-6596/86/1/012020
|
|
|
“Reactive sputter deposition of TiNx films, simulated with a particle-in-cell/Monte Carlo collisions model”. Bultinck E, Mahieu S, Depla D, Bogaerts A, New journal of physics 11, 023039 (2009). http://doi.org/10.1088/1367-2630/11/2/023039
Abstract: The physical processes in an Ar/N2 magnetron discharge used for the reactive sputter deposition of TiNx thin films were simulated with a 2d3v particle-in-cell/Monte Carlo collisions (PIC/MCC) model. Cathode currents and voltages were calculated self-consistently and compared with experiments. Also, ion fractions were calculated and validated with mass spectrometric measurements. With this PIC/MCC model, the influence of N2/Ar gas ratio on the particle densities and fluxes was investigated, taking into account the effect of the poisoned state of the target.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.786
Times cited: 23
DOI: 10.1088/1367-2630/11/2/023039
|
|
|
“Recent trends in solids mass spectrometry: GDMS and other methods”. Gijbels R, Bogaerts A, Fresenius' journal of analytical chemistry 359, 326 (1997). http://doi.org/10.1007/s002160050581
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 5
DOI: 10.1007/s002160050581
|
|
|
“Recent trends in solids mass spectrometry, with special emphasis on glow discharge mass spectrometry”. Gijbels R, Bogaerts A, , 71 (1996)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Relative sensitivity factors in glow discharge mass spectrometry: the role of charge transfer ionization”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 11, 841 (1996). http://doi.org/10.1039/ja9961100841
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 38
DOI: 10.1039/ja9961100841
|
|
|
“The role of fast argon ions and atoms in the ionization of argon in a direct current glow discharge: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of applied physics 78, 6427 (1995). http://doi.org/10.1063/1.360526
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.183
Times cited: 60
DOI: 10.1063/1.360526
|
|
|
“Role of the fast Ar atoms, Ar+ ions and metastable Ar atoms in a hollow cathode glow discharge: study by a hybrid model”. Baguer N, Bogaerts A, Gijbels R, Journal of applied physics 94, 2212 (2003). http://doi.org/10.1063/1.1594276
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 19
DOI: 10.1063/1.1594276
|
|
|
“Role of the thermophoretic force on the transport of nanoparticles in dusty silane plasmas”. de Bleecker K, Bogaerts A, Goedheer W, Physical review : E : statistical physics, plasmas, fluids, and related interdisciplinary topics 71, 066405 (2005). http://doi.org/10.1103/PhysRevE.71.066405
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.366
Times cited: 25
DOI: 10.1103/PhysRevE.71.066405
|
|
|
“A self-consistent mathematical model of a hollow cathode glow discharge”. Baguer N, Bogaerts A, Gijbels R, , 157 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Semianalytical description of nonlocal secondary electrons in a radio-frequency capacitively coupled plasma at intermediate pressures”. Berezhnoi S, Kaganovich I, Misina M, Bogaerts A, Gijbels R, IEEE transactions plasma science 27, 1339 (1999). http://doi.org/10.1109/27.799810
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.052
Times cited: 7
DOI: 10.1109/27.799810
|
|
|
“Short-pulse laser absorption in very steep plasma density gradients”. Cai H-bo, Yu W, Zhu S-ping, Zheng C-yang, Cao L-hua, Li B, Chen ZY, Bogaerts A, Physics of plasmas 13, 094504 (2006). http://doi.org/10.1063/1.2354583
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.115
Times cited: 17
DOI: 10.1063/1.2354583
|
|
|
“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
|
|
“Simulation of disk- and band-like voids in dusty plasma systems”. Liu YH, Chen ZY, Huang F, Yu MY, Wang L, Bogaerts A, Physics of plasmas 13, 052110 (2006). http://doi.org/10.1063/1.2201058
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.115
Times cited: 20
DOI: 10.1063/1.2201058
|
|
|
“Simulation of plasma processes in plasma assisted CVD reactors”. Herrebout D, Bogaerts A, Goedheer W, Dekempeneer E, Gijbels R, , 213 (1999)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Space charge limited electron emission from a Cu surface under ultrashort pulsed laser irradiation”. Wendelen W, Autrique D, Bogaerts A, AIP conference proceedings 1278, 407 (2010). http://doi.org/10.1063/1.3507129
Abstract: In this theoretical study, the electron emission from a copper surface under ultrashort pulsed laser irradiation is investigated using a one dimensional particle in cell model. Thermionic emission as well as multi-photon photoelectron emission were taken into account. The emitted electrons create a negative space charge above the target, consequently the generated electric field reduces the electron emission by several orders of magnitude. The simulations indicate that the space charge effect should be considered when investigating electron emission related phenomena in materials under ultrashort pulsed laser irradiation of metals.the word abstract, but do replace the rest of this text. ©2010 American Institute of Physics
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1063/1.3507129
|
|