toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Kips, R.; Pidduck, A.J.; Houlton, M.R.; Leenaers, A.; Mace, J.D.; Marie, O.; Pointurier, F.; Stefaniak, E.A.; Taylor, P.D.P.; van den Berghe, S.; van Espen, P.; Van Grieken, R.; Wellum, R. doi  openurl
  Title Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age Type A1 Journal article
  Year 2009 Publication Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal  
  Volume 64 Issue (up) 3 Pages 199-207  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000265755600002 Publication Date 2008-12-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:77057 Serial 7780  
Permanent link to this record
 

 
Author Janssens, K.; van Espen, P. pdf  doi
openurl 
  Title A general-purpose interface between fortran and the low-level functions of the ibm-pc Type A1 Journal article
  Year 1988 Publication Trends in analytical chemistry Abbreviated Journal  
  Volume 7 Issue (up) 4 Pages 128-130  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1988M999800003 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0165-9936 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:149778 Serial 5450  
Permanent link to this record
 

 
Author Janssens, K.; van Espen, P.; Van 't dack, L. doi  openurl
  Title Euroanalysis 14: the European Conference on Analytical Chemistry Type Editorial
  Year 2008 Publication Analytical and bioanalytical chemistry Abbreviated Journal Anal Bioanal Chem  
  Volume 391 Issue (up) 4 Pages 1107-1108  
  Keywords Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000256088700001 Publication Date 2008-05-05  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1618-2642 ISBN Additional Links UA library record; WoS full record  
  Impact Factor 3.431 Times cited Open Access  
  Notes Approved Most recent IF: 3.431; 2008 IF: 3.328  
  Call Number UA @ admin @ c:irua:69316 Serial 5608  
Permanent link to this record
 

 
Author Janssens, K.; Nobels, J.; van Espen, P. pdf  doi
openurl 
  Title PC-MCA : a software package for the acquisition and processing of spectral data Type A1 Journal article
  Year 1988 Publication Chemometrics and intelligent laboratory systems Abbreviated Journal  
  Volume 3 Issue (up) 4 Pages 335-341  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1988P260100012 Publication Date 2002-07-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0169-7439 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:149776 Serial 5768  
Permanent link to this record
 

 
Author Treiger, B.; Injuk, J.; Bondarenko, I.; van Espen, P.; Van Grieken, R.; Breitenbach, L.; Wätjen, U. doi  openurl
  Title Non-linear mapping of microbeam proton-induced X-ray emission data for source identification of North Sea aerosols Type A1 Journal article
  Year 1994 Publication Spectrochimica acta: part B : atomic spectroscopy Abbreviated Journal  
  Volume 49 Issue (up) 4 Pages 345-353  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1994NM41200004 Publication Date 2003-04-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0584-8547; 1873-3565 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:9500 Serial 8314  
Permanent link to this record
 

 
Author Cabal Rodríguez, A.E.; Leyva Pernia, D.; Schalm, O.; van Espen, P.J.M. pdf  doi
openurl 
  Title Possibilities of energy-resolved X-ray radiography for the investigation of paintings Type A1 Journal article
  Year 2012 Publication Analytical and bioanalytical chemistry Abbreviated Journal  
  Volume 402 Issue (up) 4 Pages 1471-1480  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000299842000008 Publication Date 2011-07-14  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1618-2642; 1618-2650 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:96200 Serial 8394  
Permanent link to this record
 

 
Author Cabal, A.; Legrand, S.; Van den Bril, B.; Tote, K.; Janssens, K.; van Espen, P. pdf  doi
openurl 
  Title Study of the uniformity of aerosol filters by scanning MA-XRF Type A1 Journal article
  Year 2017 Publication X-ray spectrometry T2 – 17th European Conference on X-Ray Spectrometry (EXRS), JUN 19-24, 2016, Univ Gothenburg, Univ Gothenburg, Gothenburg, SWEDEN Abbreviated Journal X-Ray Spectrom  
  Volume 46 Issue (up) 5 Pages 461-466  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Energy-dispersive X-ray fluorescence (XRF) is an attractive analytical method to determine the level of air pollution by heavy metals. The concentration of the filter in ng/cm(2) is obtained by direct comparison of the net characteristic line intensity of an element with that of a thin film standard. As the sampled area on the filter and the area of the standard are larger than the area analysed by the instrument, the distribution of the elements on the surface of both samples and standards have to be sufficiently uniform. If this is not the case, biased concentration estimates are obtained. Two scanning macro-XRF setups with a beam diameter of similar to 0.5 mm were used to investigate the distribution of elements in (1) commercially available (Micromatter) standards, (2) in-house quartz filter standards obtained with an aerosol generator and (3) particulatematter (PM10) collected on quartz filters by a Leckel SEQ 47/50 sampler. The uniformity of the Micromatter standards was better than 2%. At least some in-house standards showed a concave distribution with less material at the edges. The maximum bias introduced by this is less than 5%. Because of the limited sensitivity of scanning XRF compared with conventional XRF, the distribution of only a few common elements like Ca and Fe could be determined reliably in aerosol filters. The distribution of some heavy elements could only be measured in filters sampled in polluted regions. In general, the loading of particulate matter over the filters was uniform. Copyright (C) 2017 John Wiley & Sons, Ltd.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000409246400026 Publication Date 2017-03-21  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0049-8246 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 1.298 Times cited 4 Open Access  
  Notes ; ; Approved Most recent IF: 1.298  
  Call Number UA @ admin @ c:irua:145644 Serial 5852  
Permanent link to this record
 

 
Author Abreu, Y.; Cruz, C.M.; van Espen, P.; Pérez, C.; Piñera, I.; Leyva, A.; Cabal, A.E. pdf  doi
openurl 
  Title Electric field gradient calculations in ZnO samples implanted with 111In(111Cd) Type A1 Journal article
  Year 2012 Publication Solid state communications Abbreviated Journal  
  Volume 152 Issue (up) 5 Pages 399-402  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A first-principles study of the electric field gradient (EFG) calculated for ideal and In-111(Cd-111) implanted ZnO samples is reported in the present work. The study was made for ZnO ideal hexagonal structures and supercells were introduced in order to consider the possible implantation environments. The calculation was done using the “WIEN2k” code within the density functional theory, the exchange and correlation effects were determined by the GGA approximation. Three possible In-111(Cd-111) implantation configurations were studied, one substitutional incorporation at cation site and two interstitials. The obtained EFG values for the ideal structure and the substitutional site are in good agreement with the experimental reports measured by perturbed angular correlation (PAC) and high precision nuclear magnetic resonance (NMR). Thus, the ascription of substitutional incorporation of In-111(Cd-111) probe atom at the ZnO cation site after annealing was confirmed. (C) 2011 Elsevier Ltd. All rights reserved.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000301329200016 Publication Date 2011-12-09  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0038-1098 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:97821 Serial 7857  
Permanent link to this record
 

 
Author Schalm, O.; Cabal, A.; van Espen, P.; Laquière, N.; Storme, P. pdf  doi
openurl 
  Title Improved radiographic methods for the investigation of paintings using laboratory and synchrotron X-ray sources Type A1 Journal article
  Year 2011 Publication Journal of analytical atomic spectrometry Abbreviated Journal  
  Volume 26 Issue (up) 5 Pages 1068-1077  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract It is generally known that radiographic inspection of 1517th century paintings can easily be done with a polychromatic X-ray source using a voltage between 20 kV and 40 kV in combination with classic X-ray films. Unfortunately, the spatial structure of numerous 19th and early 20th century paintings cannot be visualized with conventional radiography due to several reasons such as the use of lead white grounds or low absorbing pigments. Radiographic images are blurred or worse, they do not contain the picture of the painting. During the last decades, many technological innovations have been introduced in the field of radiography but their possibilities in cultural heritage have not been explored in full detail. In our investigation we used phosphor imaging plates, energy dispersive detectors and CCD-cameras in combination with synchrotron radiation and conventional X-ray tubes in order to improve the quality of radiographic images. Several promising techniques that could improve the quality of radiographs of paintings were identified.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000289731900023 Publication Date 2011-04-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0267-9477 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:89928 Serial 8070  
Permanent link to this record
 

 
Author van Espen, P.; Van 't dack, L.; Adams, F.; Van Grieken, R. doi  openurl
  Title Effective sample weight from scatter peaks in energy-dispersive x-ray fluorescence Type A1 Journal article
  Year 1979 Publication Analytical chemistry Abbreviated Journal  
  Volume 51 Issue (up) 7 Pages 961-967  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos A1979GW66100047 Publication Date 2005-03-16  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2700; 5206-882x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:111404 Serial 7841  
Permanent link to this record
 

 
Author Alejo, D.; Morales, M.C.; de la Torre, J.B.; Grau, R.; Bencs, L.; Van Grieken, R.; van Espen, P.; Sosa, D.; Nuñez, V. pdf  doi
openurl 
  Title Seasonal trends of atmospheric nitrogen dioxide and sulfur dioxide over North Santa Clara, Cuba Type A1 Journal article
  Year 2013 Publication Environmental monitoring and assessment Abbreviated Journal  
  Volume 185 Issue (up) 7 Pages 6023-6033  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Atmospheric nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels were monitored simultaneously by means of Radiello passive samplers at six sites of Santa Clara city, Cuba, in the cold and the warm seasons in 2010. The dissolved ionic forms of NO2 and SO2 as nitrate and sulfite plus sulfate, respectively, were determined by means of ion chromatography. Analysis of NO2 as nitrite was also performed by UVVis spectrophotometry. For NO2, significant t tests show good agreement between the results of IC and UVVis methods. The NO2 and SO2 concentrations peaked in the cold season, while their minimum levels were experienced in the warm season. The pollutant levels do not exceed the maximum allowable limit of the Cuban Standard 39:1999, i.e., 40 μg/m3 and 50 μg/m3 for NO2 and SO2, respectively. The lowest pollutant concentrations obtained in the warm season can be attributed to an increase in their removal via precipitation (scavenging) while to the decreased traffic density and industrial emission during the summer holidays (e.g., July and August).  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000319753600053 Publication Date 2012-12-03  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1420-2026; 1573-2967 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:107293 Serial 8501  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: