“Relative sensitivity factors in glow discharge mass spectrometry: the role of charge transfer ionization”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 11, 841 (1996). http://doi.org/10.1039/ja9961100841
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 38
DOI: 10.1039/ja9961100841
|
“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, Journal of analytical atomic spectrometry 14, 429 (1999). http://doi.org/10.1039/a807276k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/a807276k
|
“Temporal and spatially resolved laser-scattering plasma diagnostics for the characterization of a ms-pulsed glow discharge”. Gamez G, Bogaerts A, Hieftje GM, Journal of analytical atomic spectrometry 21, 350 (2006). http://doi.org/10.1039/b511764j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b511764j
|
“A novel gas inlet system for improved aerosol entrainment in laser ablation inductively coupled plasma mass spectrometry”. Bleiner D, Altorfer H, Journal of analytical atomic spectrometry (2005). http://doi.org/10.1039/B505248C
Abstract: In order to minimize the dead volume in large cells for laser ablation inductively coupled plasma mass spectrometry, and improve the aerosol entrainment characteristics, the gas inlet nozzle has been set in rotation. This allowed a wider volume to be swept than with the traditional static inlet nozzle approach. Therefore, sensitivity combined with site-to-site repeatability was improved by a factor of two, together with minimization of aerosol loss within the cell and signal dispersion.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/B505248C
|
“Overcoming pulse mixing and signal tailing in laser ablation inductively coupled plasma mass spectrometry depth profiling”. Bleiner D, Belloni F, Doria D, Lorusso A, Nassisi V, Journal of analytical atomic spectrometry (2005). http://doi.org/10.1039/B509379C
Abstract: The laser ablation-induced plasma was used as a composition-con trolled source for ion implantation in Si crystals. Then, laser ablation in combination with inductively coupled plasma mass spectrometry was used for the elemental depth profiling of the implanted samples. Monte Carlo simulations permitted us to conclude that a depth resolution of tens of nm would be necessary to define the shape of the implantation profiles, as is obtained using XPS and RBS, whereas a hundred nm depth resolution is sufficient to determine the total implanted dose. The detection power of LA-ICP-MS would routinely allow rapid analytical control on the trace level implanted dose. Nevertheless, this technique is limited in terms of depth profiling resolution due to pulse mixing and signal tailing induced during the aerosol transport. Raw signal processing procedures were developed for the minimization of shapeline dispersion, deconvolution of pulse mixing and more appropriate assessment of the implanted profiles. Shapeline dispersion could be corrected for by determining the signal waning constant and implementing this information for a non-affine alibi transformation of the LA-ICP-MS signal traces. Pulse mixing deconvolution was attained with an algorithm that considered accumulated signal intensity due to pulse-on-pulse stacking, i.e., the latest pulse on top of all antecedent individual pulses' exponential tails proportionally.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 26
DOI: 10.1039/B509379C
|
“Micro-heterogeneity study of trace elements in USGS, MPI-DING and glass reference materials by means of synchrotron micro-XRF”. Kempenaers L, Janssens K, Jochum KP, Vincze L, Vekemans B, Somogyi A, Drakopoulos M, Adams F, Journal of analytical atomic spectrometry 18, 350 (2003). http://doi.org/10.1039/B212196D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 38
DOI: 10.1039/B212196D
|
“Suitability of polycapillary optics for focusing of monochromatic synchrotron radiation as used in trace level micro-XANES measurements”. Vincze L, Wei F, Proost K, Vekemans B, Janssens K, He Y, Yan Y, Falkenberg G, Journal of analytical atomic spectrometry 17, 177 (2002). http://doi.org/10.1039/B110210A
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/B110210A
|