|
“Empirical evaluation of metal deposition for the analysis of organic compounds with static secondary ion mass spectrometry (S-SIMS)”. de Mondt R, Adriaensen L, Vangaever F, Lenaerts J, van Vaeck L, Gijbels R, Applied surface science 252, 6652 (2006). http://doi.org/10.1016/j.apsusc.2006.02.110
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 9
DOI: 10.1016/j.apsusc.2006.02.110
|
|
|
“Exchange of fluorinated cyanine dyes between different types of silver halide microcrystals studied by imaging time-of-flight secondary ion mass spectrometry”. Lenaerts J, Verlinden G, van Vaeck L, Gijbels R, Geuens I, Callant P, Langmuir 17, 7332 (2001). http://doi.org/10.1021/la010862t
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.833
Times cited: 8
DOI: 10.1021/la010862t
|
|
|
“Comparison of mono- and polyatomic primary ions for the characterization of organic dye overlayers with static secondary ion mass spectrometry”. Lenaerts J, van Vaeck L, Gijbels R, Van Luppen J, Rapid communications in mass spectrometry 18, 257 (2004). http://doi.org/10.1002/rcm.1320
Abstract: Organic carbocyanine dye coatings have been analyzed by time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) using three types of primary ions: Ga+ operating at 25 keV, and Xe+ and SF5+ both operating at 9 keV. Secondary ion yields obtained with these three primary ions have been compared for coatings with different layer thickness, varying from (sub)-monolayer to multilayers, on different substrates (Si, Ag and AgBr cubic microcrystals). For (sub)-monolayers deposited on Ag, Xe+ and SF5+ primary ions generate similar precursor ion intensities, but with Ga+ slightly lower precursor ion intensities were obtained. Thick coatings on Ag as well as mono- and multilayers on Si produce the highest precursor and fragment ion intensities with the polyatomic primary ion. The yield difference between SF5+ and Xe+ can reach a factor of 6. In comparison with Ga+, yield enhancements by up to a factor of 180 are observed with SF5+. For the mass spectrometric analysis of dye layers on AgBr microcrystals, SF5+ again proves to be the primary ion of choice. Copyright (C) 2004 John Wiley Sons, Ltd.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 5
DOI: 10.1002/rcm.1320
|
|
|
“Modeling of the sputtering process of cubic silver halide microcrystals and its relevance in depth profiling by secondary ion-mass spectrometry (SIMS)”. Lenaerts J, Verlinden G, Ignatova VA, van Vaeck L, Gijbels R, Geuens I, Fresenius' journal of analytical chemistry 370, 654 (2001). http://doi.org/10.1007/s002160100880
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 3
DOI: 10.1007/s002160100880
|
|
|
“Chemical characterization of neo-ceramic powders by time-of-flight and Fourier transform laser microprobe mass spectrometry”. Struyf H, van Vaeck L, Kennis P, Gijbels R, van Grieken R, Rapid communications in mass spectrometry 10, 699 (1996). http://doi.org/10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
Abstract: Laser microprobe mass spectrometry (LMMS) aims at the identification of local organic and inorganic constituents at the surface of solids, The low mass resolution capabilities of the initially used time-of-flight (TOF) mass spectrometers have often proved to be insufficient for identification, Therefore, high mass resolution Fourier transform (ET) LMMS was developed, Neo-ceramic powders with oxide or carbide coatings were analyzed by both FT LMMS and TOF LMMS, The data are useful to compare the analytical information gained from both methods, Analytical results of these samples by electron microprobe x-ray analysis (EPXMA) and secondary ion mass spectrometry (SIMS) are discussed to assess the place of FT LMMS and TOF LMMS in the spectrum of microanalytical techniques.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.253
Times cited: 11
DOI: 10.1002/(SICI)1097-0231(199604)10:6<699::AID-RCM521>3.0.CO;2-8
|
|
|
“Laser ionization mass-spectrometry for the characterization of solid materials”. van Vaeck L, Vanroy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 20, S29 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Metal and composite nanocluster precipitate formation in silicon dioxide implanted with Sb+ ions”. Ignatova VA, Lebedev OI, Watjen U, van Vaeck L, van Landuyt J, Gijbels R, Adams F, Journal of applied physics 92, 4336 (2002). http://doi.org/10.1063/1.1508425
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 5
DOI: 10.1063/1.1508425
|
|