|
Records |
Links |
|
Author |
Van Grieken, R. |
|
|
Title |
New members of the editorial board of X-ray Spectrometry |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
42 |
Issue |
1 |
Pages |
1-2 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000314971600001 |
Publication Date |
2012-12-22 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:104627 |
Serial |
8301 |
|
Permanent link to this record |
|
|
|
|
Author |
van der Linden, V.; Schalm, O.; Houbraken, J.; Thomas, M.; Meesdom, E.; Devos, A.; van Dooren, R.; Nieuwdorp, H.; Janssen, E.; Janssens, K. |
|
|
Title |
Chemical analysis of 16th to 19th century Limoges School painted enamel objects in three museums of the Low Countries |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
39 |
Issue |
2 |
Pages |
112-121 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this study, the results of analysing of a series of 16th-19th century painted enamel objects of the Limoges School currently in collections in three Dutch and Flemish museums by means of portable and micro x-ray fluorescence analysis (PXRF and µ-XRF) and electron probe micro analysis (EPMA) are presented. The aim of the investigation was the authentication of specific pieces. Therefore, the glass compositions as well as the (glass) colouring agents used by the Limoges' artists were studied as a function of the age of the objects. Due to the evolution of these properties, it is possible to approximately date these objects based on their chemical composition. The complete émail peint collection of the Museum Boijmans-Van Beuningen (Rotterdam, The Netherlands), consisting of 20 émail peint plaques, was analysed with µ-XRF. Quantitative information was obtained by EPMA analysis of 15 enamel fragments of objects from museum and private collections in the Low Countries. PXRF analyses were performed on the painted enamel collection of the Antwerp Vleeshuis Museum (13 objects) and the Mayer van den Bergh Museum (4 objects) and on a set of 18 plaques that were donated to the Boijmans-Van Beuningen Museum by a private collector. The results obtained by means of EPMA, µ-XRF and PXRF proved to be useful in the discrimination of 16th century painted enamel objects from those of the19th century. From a total of 70 objects examined, 2 objects (OM964A and OM993) featured a chemical signature that deviated from the published literature composition and pigment use consistent with its presumed period of manufacture. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000275959400007 |
Publication Date |
2009-08-11 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 1.298; 2010 IF: 1.661 |
|
|
Call Number |
UA @ admin @ c:irua:82325 |
Serial |
5509 |
|
Permanent link to this record |
|
|
|
|
Author |
Storms, H.M.; Janssens, K.H.; Török, S.B.; Van Grieken, R.E. |
|
|
Title |
Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles |
Type |
A1 Journal article |
|
Year |
1989 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
18 |
Issue |
2 |
Pages |
45-52 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1989U261400001 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116489 |
Serial |
5616 |
|
Permanent link to this record |
|
|
|
|
Author |
van der Snickt, G.; Janssens, K.; Schalm, O.; Aibéo, C.; Kloust, H.; Alfeld, M. |
|
|
Title |
James Ensor's pigment use: artistic and material evolution studied by means of portable X-ray fluorescence spectrometry |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
39 |
Issue |
2 |
Pages |
103-111 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In this paper, portable X-ray fluorescence spectrometry (PXRF) was employed as a screening tool for determining and comparing the pigment use in a large series of paintings by the Belgian artist James Ensor (1860-1949). Benefits and drawbacks of PXRF as a method, and the instrument employed, are discussed from a practical, conservation and instrumental perspective. Regardless of several restrictions due to the set-up and/or the analytical method, it appeared feasible to document the evolution with time in Ensor's use of inorganic pigments and to correlate this technical evolution with stylistic developments, Nevertheless, it became clear that a full identification of all materials present can only be done by means of the analysis of (cross-sectioned) samples. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000275959400006 |
Publication Date |
2009-12-15 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
25 |
Open Access |
|
|
|
Notes |
; This research was supported by the Interuniversity Attraction Poles Programme – Belgian Science Policy (IUAP VI/16). The staff of the different museums and private institutions is acknowledged for rendering their assistance to this research, i.e. by making all paintings available for analysis and authorising the publication of the images in this article. Therefore, a word of gratitude to Paul Huvenne, Yolande Deckers, Herwig Todts, Stef Antonissen, Gwen Borms and Lizet Klaassen of the Koninklijk Museum voor Schone Kunsten Antwerpen (KMSKA), Luuk Van der Loeff of the Kroller-Muller Museum in Otterlo and Mireille Engel, Barbara De Jong of the Musea aan Zee (MuZee), Patricia Jaspers of the Dexia bank, Hildegard Van de Velde of the KBC bank and Frederik Leen of the Koninklijke Musea voor Schone Kunsten van Belgie (KMSKB). Special thanks to Xavier Tricot and the other members of the Ensor committee for their valuable feedback. ; |
Approved |
Most recent IF: 1.298; 2010 IF: 1.661 |
|
|
Call Number |
UA @ admin @ c:irua:82324 |
Serial |
5680 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Dyck, P.; Markowicz, A.; Van Grieken, R. |
|
|
Title |
Automatic absorption correction in x-ray fluorescence analysis of intermediate thickness samples using a dual external reference signal |
Type |
A1 Journal article |
|
Year |
1980 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
9 |
Issue |
2 |
Pages |
70-76 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A method has been investigated which allows calculations from the X-ray fluorescence spectra of the absorption coefficients at any energy for any sample, without any additional measurement. Use is made of the ratio of the characteristic X-ray signals from a Zr wire positioned in front of the sample and from a Pd foil placed behind the sample, both in a fixed geometry. From the experimentally measured absorption coefficient at the Pd L energy (2.9 keV), the coefficients for higher energies are calculated. By the use of an iterative computer routine in which corrections for the enhancement of the Pd foil by the sample are also included, an accuracy of 2% or better on the absorption coefficient determination can be reached for homogenous samples in one measurement. Grain-size and heterogeneity effects induce inaccuracies on the absorption coefficient determinations which might well reach 20% for particulate samples like intermediate thickness deposits of geological materials. This approach thus has the same limitations as the classical transmission method for such heterogeneous samples. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1980JN16500007 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116483 |
Serial |
7541 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R. |
|
|
Title |
Awards for best referees of X-ray Spectrometry |
Type |
Editorial |
|
Year |
2014 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
43 |
Issue |
2 |
Pages |
68-69 |
|
|
Keywords |
Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
2014-02-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:114471 |
Serial |
7542 |
|
Permanent link to this record |
|
|
|
|
Author |
Belikov, K.N.; Mikhailova, L.I.; Spolnik, Z.M.; Van Grieken, R. |
|
|
Title |
EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
35 |
Issue |
2 |
Pages |
112-115 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000236405500005 |
Publication Date |
2005-10-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:56727 |
Serial |
7835 |
|
Permanent link to this record |
|
|
|
|
Author |
Markowicz, A.; Storms, H.; Van Grieken, R. |
|
|
Title |
Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
15 |
Issue |
2 |
Pages |
131-133 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986C017300009 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113873 |
Serial |
7937 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R.E.; Adams, F.C. |
|
|
Title |
Folding of aerosol loaded filters during X-ray fluorescence analysis |
Type |
A1 Journal article |
|
Year |
1976 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
5 |
Issue |
2 |
Pages |
61-67 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1976BM95300002 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116480 |
Serial |
7976 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R. |
|
|
Title |
Introducing John Campbell, the new regional editor for North America of X-Ray Spectrometry |
Type |
Editorial |
|
Year |
2014 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
43 |
Issue |
2 |
Pages |
67 |
|
|
Keywords |
Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000331386000001 |
Publication Date |
2014-02-07 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:114470 |
Serial |
8120 |
|
Permanent link to this record |
|
|
|
|
Author |
Markowicz, A.; Van Dyck, P.; Van Grieken, R. |
|
|
Title |
Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis |
Type |
A1 Journal article |
|
Year |
1980 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
9 |
Issue |
2 |
Pages |
52-56 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1980JN16500003 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116482 |
Serial |
8451 |
|
Permanent link to this record |
|
|
|
|
Author |
Markowicz, A.; Storms, H.; Van Grieken, R. |
|
|
Title |
A simple absorption correction for electron probe X-ray microanalysis of bulk samples |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
15 |
Issue |
2 |
Pages |
115-119 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986C017300007 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113872 |
Serial |
8524 |
|
Permanent link to this record |
|
|
|
|
Author |
Proost, K.; Vincze, L.; Janssens, K.; Gao, N.; Bulska, E.; Schreiner, M.; Falkenberg, G. |
|
|
Title |
Characterization of a polycapillary lens for use in micro-XANES experiments |
Type |
A1 Journal article |
|
Year |
2003 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
32 |
Issue |
3 |
Pages |
215-222 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000183630400007 |
Publication Date |
2003-06-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
50 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.298; 2003 IF: 1.227 |
|
|
Call Number |
UA @ admin @ c:irua:41804 |
Serial |
5502 |
|
Permanent link to this record |
|
|
|
|
Author |
Rindby, A.; Janssens, K.; Osán, J. |
|
|
Title |
Reconstruction of the three-dimensional distribution of elements in fly-ash particles by micro-XRF spectroscopy |
Type |
A1 Journal article |
|
Year |
2003 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
32 |
Issue |
3 |
Pages |
248-257 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000183630400011 |
Publication Date |
2003-06-12 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
8 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 1.298; 2003 IF: 1.227 |
|
|
Call Number |
UA @ admin @ c:irua:41805 |
Serial |
5807 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Dyck, P.; Van Grieken, R. |
|
|
Title |
Automated matrix-correction of line ratios in energy-dispersive x-ray fluorescence spectrum deconvolution |
Type |
A1 Journal article |
|
Year |
1983 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
12 |
Issue |
3 |
Pages |
111-114 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Most computer XRF-spectrum deconvolution routines make use of fixed intensity ratios for the lines from one element. The magnitude of the error that fixed ratios imply has been quantitatively evaluated for samples with a varible thickness or matrix. A procedure for routinely adapting the line ratios according to the matrix effect in every sample (by making use of the matrix information present in the scatter peaks) enhances the accuracy of the spectrum evaluation. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1983RA69700004 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116484 |
Serial |
7539 |
|
Permanent link to this record |
|
|
|
|
Author |
Cabal, A.; Schalm, O.; Eyskens, P.; Willems, P.; Harth, A.; van Espen, P. |
|
|
Title |
Comparison of x-ray absorption and emission techniques for the investigation of paintings |
Type |
A1 Journal article |
|
Year |
2015 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
44 |
Issue |
3 |
Pages |
141-148 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES) |
|
|
Abstract |
Four x-ray techniques: computed radiography, emission radiography, energy-resolved radiography and imaging x-ray fluorescence were compared using four mock-up panel paintings. The paintings have different stratigraphy and pigments and are representative for different historical periods. One of the paintings has a hidden underlying painting. The type of pigments used mainly influences the information obtained by both the emission and absorption measurements; high-Z white pigment and high-Z color pigments giving the best contrast. Each of the techniques revealed interesting aspects of the paintings, but none of them could reveal the hidden painting to a satisfactory level. Due to the statistical quality of the spectral data, x-ray fluorescence gives elemental images with high contrast. The radiographic images are better to reveal the internal structure. Imaging x-ray fluorescence and energy-resolved radiography measurements can be done simultaneously, and the combination has the highest potential for the study of complex multilayer paintings. Copyright (c) 2015 John Wiley & Sons, Ltd. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000353644500010 |
Publication Date |
2015-02-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:126016 |
Serial |
7698 |
|
Permanent link to this record |
|
|
|
|
Author |
Čevik, U.; Koz, B.; Makarovska, Y. |
|
|
Title |
Heavy metal analysis around Iskenderun Bay in Turkey |
Type |
A1 Journal article |
|
Year |
2010 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
39 |
Issue |
3 |
Pages |
202-207 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The heavy metal analysis around Iskenderun Bay in Turkey was carried out using mosses, soils, mussels, and sediments. This region is one of the most industrial areas of Turkey, including iron-steel plants, beverage, liquefied petroleum gas (LPG) plants, and oil transfer docks. Energy dispersive X-ray fluorescence spectrometry (Epsilon 5, PANalytical, Almelo, The Netherlands) was used to analyze all samples. V, Cr, Mn, Fe, Ni, Cu, Zn, As, and Pb elements were observed in all samples studied. Although Ce was detected in some mosses and soils, Sn was detected only in some moss samples. Pb concentrations in the moss samples are higher than the soil, the mussel, and the sediment samples. This can be attributed to the mosses that absorb heavy metals such as Pb easily from the air. As the aim of this study was to analyze heavy metals, the evaluation of these elements with their potential hazards for ecology and humans is briefly discussed |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000277637400006 |
Publication Date |
2010-03-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:82678 |
Serial |
8020 |
|
Permanent link to this record |
|
|
|
|
Author |
Marguí, E.; Padilla, R.; Hidalgo, M.; Queralt, I.; Van Grieken, R. |
|
|
Title |
High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
35 |
Issue |
3 |
Pages |
169-177 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000237818300005 |
Publication Date |
2006-03-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:57751 |
Serial |
8031 |
|
Permanent link to this record |
|
|
|
|
Author |
Ozen, S.A.; Ozkalayci, F.; Cevik, U.; Van Grieken, R. |
|
|
Title |
Investigation of heavy metal distributions along 15m soil profiles using EDXRF, XRD, SEM-EDX, and ICP-MS techniques |
Type |
A1 Journal article |
|
Year |
2018 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
47 |
Issue |
3 |
Pages |
231-241 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The research of soil contamination by heavy metal is an important field due to its environmental and health implications. The goal was to study the elemental mobility as a function of depth. For this reason, the distribution of heavy metals (V, Cr, Co, Ni, Cu, Zn, As, Sn, and Pb) was investigated along soil profiles up to a depth of 15m at 9 sampling sites in the Nilufer industrial district (Bursa, Turkey). Elemental analyses were done with the Epsilon 5 energy dispersive X-ray fluorescence and inductively coupled plasma mass spectrometry equipment. Particle analysis was performed with a JEOL scanning electron microscope equipped with a Si(Li) X-ray detector. The crystallographic compositions of oxide compounds in soil samples were identified by a Rigaku X-ray diffraction instrument. Different parameters such as the soil's chemical (mineralogical structure, pH, and electrical conductivity) and physical properties (the number of blows, the stiffness index, the liquidity index, the plasticity index, and the water content) were analyzed. To assess the mobility of the heavy metals, diffusion (D) and convection coefficients (?) were calculated with the finite difference method. Convection was determined to dominate the studied region. In addition, the mobility coefficient was determined for each metal. High mobilities were determined for Zn and V, moderate mobilities for Cr, Ni, Cu, and As, and low mobilities were determined for Co and Pb. The results revealed that elements had reached depths of up to 15m, causing irreversible soil contamination that may lead to environmental health issues. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000430188700005 |
Publication Date |
2018-03-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:150722 |
Serial |
8123 |
|
Permanent link to this record |
|
|
|
|
Author |
Worobiec, A.; Kaplinski, A.; Van Grieken, R. |
|
|
Title |
Ruthenium staining as an alternative preparation method for automated EPMA of individual biogenic and organic particles |
Type |
A1 Journal article |
|
Year |
2005 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
34 |
Issue |
3 |
Pages |
245-252 |
|
|
Keywords |
A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000229093000014 |
Publication Date |
2005-01-31 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:52229 |
Serial |
8488 |
|
Permanent link to this record |
|
|
|
|
Author |
Muia, L.M.; Van Grieken, R. |
|
|
Title |
Use of theoretical accurate binary influence coefficients with Tertian's equation in X-ray fluorescence analysis of silicate rocks in borax glass beads |
Type |
A1 Journal article |
|
Year |
1990 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
19 |
Issue |
3 |
Pages |
141-144 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A study of the suitability of the Tertian algorithm using new accurate binary influence coefficients and a comparison standard for x-ray fluorescence analysis of geological materials prepared as borax glass beads was performed. The algorithm was found to give satisfactory results for the analysis of four major components in geological materials. Even in the worst case, when there is a factor of 20 difference in the concentration in the specimen and a comparison standard, the algorithm gives results which differ from the true results by a factor of about 2. This makes the algorithm attractive as a diagnostic tool in analyses of unknown specimens and in the identification of appropriate standards. The binary coefficients are easily calculated so that the algorithm can be implemented on a minicomputer. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1990DJ47800009 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116492 |
Serial |
8725 |
|
Permanent link to this record |
|
|
|
|
Author |
Amato, S.R.; Burnstock, A.; Cross, M.; Janssens, K.; Rosi, F.; Cartechini, L.; Fontana, R.; Dal Fovo, A.; Paolantoni, M.; Grazia, C.; Romani, A.; Michelin, A.; Andraud, C.; Tournie, A.; Dik, J. |
|
|
Title |
Interpreting technical evidence from spectral imaging of paintings by Edouard Manet in the Courtauld Gallery |
Type |
A1 Journal article |
|
Year |
2019 |
Publication |
X-ray spectrometry
T2 – MA-XRF Workshop on Developments and Applications of Macro-XRF in, Conservation, Art, and Archeology, SEP 24-25, 2017, Trieste, ITALY |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
48 |
Issue |
4 |
Pages |
282-292 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The paintings by edouard Manet in The Courtauld Gallery Dejeuner sur l'herbe (1863-68), Marguerite de Conflans en Toilette de Bal (1870-1880), Banks of the Seine at Argenteuil (1874), and A Bar at the Folies-Bergere (1882) were investigated for the first time using a range of non-invasive in situ analyses. The aims of the study were to investigate the painting techniques and materials used for this group of works and to critically evaluate the technical evidence derived from the integrated use of imaging techniques and portable spectroscopic methods in this context. The paintings were investigated by means of macro X-ray fluorescence (MA-XRF), reflection spectral imaging, portable UV-Vis-NIR spectroscopy, portable Raman spectroscopy, and reflection FTIR. MA-XRF and reflection spectral imaging allowed visualising elements in the compositions that were not visible using traditional methods of technical study. For example, MA-XRF analysis of Dejeuner sur l'herbe revealed elements of the development of the composition that provided new evidence to consider its relationship to other versions of the composition. The study also highlighted questions about the interpretation of elemental distribution maps and spectral images that did not correspond to the reworking visible in X-radiographs. For example, in A Bar at the Folies-Bergere Manet made numerous changes during painting, which were not clearly visualised with any of the techniques used. The research has wider implications for the study of Impressionist paintings, as the results will support technical studies of works by other artists of the period who used similar materials and painting methods. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000472210700005 |
Publication Date |
2018-01-23 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
|
Open Access |
|
|
|
Notes |
; Financial support by the Access to Research Infrastructures activity in the Horizon 2020 Programme of the EU (IPERION CH Grant agreement 654028) is gratefully acknowledged. ; |
Approved |
Most recent IF: 1.298 |
|
|
Call Number |
UA @ admin @ c:irua:161296 |
Serial |
5670 |
|
Permanent link to this record |
|
|
|
|
Author |
Romano, F.P.; Janssens, K. |
|
|
Title |
Preface to the special issue on: MA-XRF “developments and applications of macro-XRF in conservation, art, and archeology” (Trieste, Italy, 24 and 25 September 2017) |
Type |
Editorial |
|
Year |
2019 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
48 |
Issue |
4 |
Pages |
249-250 |
|
|
Keywords |
Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000472210700001 |
Publication Date |
2019-05-10 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
|
Open Access |
|
|
|
Notes |
; ; |
Approved |
Most recent IF: 1.298 |
|
|
Call Number |
UA @ admin @ c:irua:161295 |
Serial |
5786 |
|
Permanent link to this record |
|
|
|
|
Author |
Vanmeert, F.; Mudronja, D.; Fazinic, S.; Janssens, K.; Tibljas, D. |
|
|
Title |
Semi-quantitative analysis of the formation of a calcium oxalate protective layer for monumental limestone using combined micro-XRF and micro-XRPD |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
X-Ray Spectrom |
|
|
Volume |
42 |
Issue |
4 |
Pages |
256-261 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A current method for the protection of cretaceous limestone present in various monuments consists of performing a passivating treatment with ammonium oxalate (AmOx). A calcium oxalate protective layer is formed on the surface and enhances the acid resistance of the stone. The in-depth formation of the calcium oxalate layer was investigated on cross sections by using combined micro X-ray fluorescence and micro X-ray powder diffraction (mu XRF/mu XRPD). XRPD showed the presence of both whewellite and weddellite in the calcite stone matrix. A correction was made for sample misalignment, which was visible in both the fluorescence and the diffraction line measurements. A semi-quantitative analysis was performed on the basis of Klug's equation for a two-phase mixture (the presence of weddellite was neglected) without the need for a known reference sample. By assuming two extreme compositions for a reference weight fraction (1 and 99wt%), it was possible to obtain whewellite concentration profiles, which can be used for comparing the effectiveness of different methods for the application of AmOx to the stone surface and the effect of treatment time and AmOx concentration used. It is shown that for the relative amounts of whewellite formed, the differences due to the assumed weight fractions are smaller than the errors due to sample heterogeneity and preferred orientation. Copyright (c) 2013 John Wiley & Sons, Ltd. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000320727900015 |
Publication Date |
2013-05-14 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
1.298 |
Times cited |
5 |
Open Access |
|
|
|
Notes |
; The authors would like to thank De Nolf W. for his valuable feedback on the analysis of the X-ray diffraction data. We acknowledge SOLEIL for provision of SR facilities (proposal ID 20100979), and we would like to thank Dr. C. Mocuta for his assistance at the DIFFABS beamline. This research was supported by the Interuniversity Attraction Poles Program – Belgian Science Policy (IUAP VI/16). The text also presents results of GOA 'XANES meets ELNES' (Research Fund University of Antwerp, Belgium) and from FWO (Brussels, Belgium) projects no. G.0704.08 and G.01769.09. The EU Community's FP7 Research Infrastructures program for the CHARISMA Project (grant agreement 228330) and, within framework in particular, the access possibilities to the SOLEIL and IPANEMA facilities are also acknowledged. ; |
Approved |
Most recent IF: 1.298; 2013 IF: 1.187 |
|
|
Call Number |
UA @ admin @ c:irua:109579 |
Serial |
5827 |
|
Permanent link to this record |
|
|
|
|
Author |
Godoi, R.H.M.; Potgieter-Vermaak, S.; Godoi, A.F.L.; Stranger, M.; Van Grieken, R. |
|
|
Title |
Assessment of aerosol particles within the Rubens' House Museum in Antwerp, Belgium |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
37 |
Issue |
4 |
Pages |
298-303 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
The majority of researchers, conservators and curators recognise that atmospheric pollution is one of the major threats to works of art. In principle, all atmospheric particles, when deposited onto art objects can be considered harmful because of their potential in causing deterioration. Moreover, under certain conditions, particulate matter can induce and intensify surface damage, particularly because of its potential to serve as centre for moisture condensation and adsorbent of gaseous pollutants. To investigate the potential harm that these particles can cause, comprehensive characterisation of the particulate matter is necessary. Particulate matter was collected at the Rubens' House Museum in Antwerp, Belgium, where a unique exhibit of the paintings and living quarters of Peter Paul Rubens (1577-1640) are seen. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental and molecular compositions. They were analysed by electron probe micro-analysis, utilising facilities for low-Z element determination, and by energy-dispersive x-ray fluorescence, to investigate the elemental composition of individual particles and bulk samples, and by micro Raman spectrometry, to elucidate the molecular composition. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could contribute to the chemical reactions taking place on the surfaces of artefacts and which could potentially cause degradation of the objects. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000258670600004 |
Publication Date |
2008-03-10 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:69494 |
Serial |
7499 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R. |
|
|
Title |
Editorial : introducing Dr Markowicz as X-Ray Spectrometry's new associate editor for Europe |
Type |
A1 Journal article |
|
Year |
2013 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
42 |
Issue |
4 |
Pages |
175 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000320727900001 |
Publication Date |
2013-06-20 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:108738 |
Serial |
7832 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Dyck, P.; Markowicz, A.; Van Grieken, R. |
|
|
Title |
Influence of sample thickness, excitation energy and geometry on particle size effects in XRF |
Type |
A1 Journal article |
|
Year |
1985 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
14 |
Issue |
4 |
Pages |
183-187 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1985ATB6100007 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:116486 |
Serial |
8097 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Dyck, P.; Török, S.; Van Grieken, R. |
|
|
Title |
Monte Carlo simulation of backscattered peaks in secondary target energy-dispersive X-ray spectra |
Type |
A1 Journal article |
|
Year |
1986 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
15 |
Issue |
4 |
Pages |
231-238 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
A Monte Carlo simulation has been developed to describe the incoherent and coherent scatter processes for the complex geometry of a secondary target energy-dispersive x-ray fluorescence system. Photons are followed from the x-ray tube anode until the detection of scattered secondary target photons in the active Si layer of the detector. The program quantitatively shows the broadening of the incoherent scatter peak with increasing atomic number, and it models the incoherent peak shape adequately. The incoherent-to-coherent scatter intensity ratios obtained differ by 1030% from the theoretical values, while their dependence on the sample atomic number corresponds to that expected from theory. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
A1986E535600001 |
Publication Date |
2005-05-28 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:113612 |
Serial |
8280 |
|
Permanent link to this record |
|
|
|
|
Author |
Van Grieken, R. |
|
|
Title |
New Chinese members of the Advisory Board of X-Ray Spectrometry |
Type |
A1 Journal article |
|
Year |
2006 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
35 |
Issue |
4 |
Pages |
205-206 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
|
Publication Date |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:58861 |
Serial |
8297 |
|
Permanent link to this record |
|
|
|
|
Author |
Arana, A.; Loureiro, A.L.; Barbosa, H.M.J.; Van Grieken, R.; Artaxo, P. |
|
|
Title |
Optimized energy dispersive X-ray fluorescence analysis of atmospheric aerosols collected at pristine and perturbed Amazon Basin sites |
Type |
A1 Journal article |
|
Year |
2014 |
Publication |
X-ray spectrometry |
Abbreviated Journal |
|
|
|
Volume |
43 |
Issue |
4 |
Pages |
228-237 |
|
|
Keywords |
A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation) |
|
|
Abstract |
Elemental composition of aerosols is important to source apportionment studies and to understand atmospheric processes that influence aerosol composition. Energy dispersive X-ray fluorescence spectroscopy was applied for measuring the elemental composition of Amazonian atmospheric aerosols. The instrument used was a spectrometer Epsilon 5, PANalytical B. V., with tridimensional geometry that reduces the background signal with a polarized X-ray detection. The measurement conditions were optimized for low-Z elements, e. g. Mg, Al, Si, that are present at very low concentrations in the Amazon. From Na to K, our detection limits are about 50% to 75% lower than previously published results for similar instrument. Calibration was performed using Micromatter standards, except for P whose standard was produced by nebulization of an aqueous solution of KH2PO4 at our laboratory. The multi-element reference material National Institute of Standards and Technology-2783 (air particulate filter) was used for evaluating the accuracy of the calibration procedure of the 22 elements in our standard analysis routine, and the uncertainty associated with calibration procedures was evaluated. The overall performance of the instrument and validation of our measurements were assessed by comparison with results obtained from parallel analysis using particle-induced X-ray emission and another Epsilon 5 spectrometer. The elemental composition in 660 samples collected at a pristine site in the Amazon Basin and of 1416 samples collected at a site perturbed by land use change was determined. Our measurements show trace elements associated with biogenic aerosols, soil dust, biomass burning, and sea-salt, even for the very low concentrations as observed in Amazonia. Copyright (C) 2014 John Wiley & Sons, Ltd. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Wos |
000337724600006 |
Publication Date |
2014-06-09 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0049-8246 |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
|
Times cited |
|
Open Access |
|
|
|
Notes |
|
Approved |
no |
|
|
Call Number |
UA @ admin @ c:irua:118419 |
Serial |
8342 |
|
Permanent link to this record |