“Trace metal fractionation effects between sea water and aerosols from bubble bursting”. Van Grieken RE, Johansson TB, Winchester JW, Journal de recherches atmosphériques 8, 611 (1974)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Comparison of 3 dry deposition models applied to field-measurements in the Southern Bight of the North-Sea”. Rojas CM, Van Grieken RE, Laane RW, Atmospheric environment 27, 363 (1993). http://doi.org/10.1016/0960-1686(93)90110-K
Abstract: Dry deposition velocities have been calculated using three different approaches. Turbulent wind profile theory has been used to predict the drag coefficient, wind speed and friction velocity at 10 m height when the wind speed is measured at a higher altitude. The resulting parameters were introduced in a two-layer deposition model. The second approach was the well-known model of Slinn and Slinn (1980, Atmospheric Environment 14, 1013-1016), whereas the third corresponded to the model published by Williams (1982, Atmospheric Environment 16, 1933 1938). Results point to clear differences. However, in a field experiment carried out at the Southern Bight of the North Sea, all three approaches show relatively comparable results. The role played by the size distribution of atmospheric particulate matter is essential. In our case any of the three models could have given satisfactory outcomes taking into account the wide spread of the experimental results cited in the literature for the same airshed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(93)90110-K
|
“Influence of fixation procedures on the microanalysis of lead-induced intranuclear inclusions in rat kidney”. Vandeputte DF, Jacob WA, Van Grieken RE, The journal of histochemistry and cytochemistry 38, 331 (1990). http://doi.org/10.1177/38.3.2154517
Abstract: Using Laser Microprobe Mass Analysis (LAMMA), we studied the chemical composition of lead-induced intranuclear inclusions in rat kidney tissue prepared by three different wet chemical fixation procedures for transmission electron microscopy. Fixation with glutaraldehyde-Na2S gave the same results as fixation with glutaraldehyde only: a high lead concentration could be detected. Therefore, for lead strongly bound to proteins, precipitation procedures are not essential. Post-fixation with osmium tetroxide drastically changed the composition of the inclusions: the lead concentration decreased substantially, while sodium, calcium, and barium were introduced. The osmium tetroxide fixative was found to be the source of the contamination. It also contained aluminum, and we suggest that other proteins (e.g., in neurofibrillary tangles) might be able to take up Al out of solution and that care must be exercised in interpreting the microanalytical results of osmium-fixed material. For the microanalysis of the lead inclusions, fixation with glutaraldehyde only provides a good compromise between preservation of the ultrastructure and maintenance of the element distribution.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1177/38.3.2154517
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
“Trace metal analysis of water containing humic substances by X-ray fluorescence”. Vanderborght BM, Van Grieken RE, International journal of environmental analytical chemistry 5, 221 (1978). http://doi.org/10.1080/03067317808071147
Abstract: Chelation by oxine followed by adsorption on activated carbon results in the efficient collection of many trace metal ions, independent of the trace metal concentration and of high alkali and alkaline earth ion abundances. Preconcentration factors around 10000 are often achieved. When this preconcentration procedure is combined with energy-dispersive X-ray fluorescence, accurate and precise analysis can be carried out, as was proven in several experiments. The technique can also be applied for the determination of divalent ions in natural waters containing up to 10 ppm of humic substances. Trivalent ions can quantitatively be collected from natural water provided suKicient activated carbon is added. Omitting the oxine chelation prior to the activated carbon adsorption step still results in collection of a sometimes important fraction of the trace metal ions from natural waters. This is related to organically bound or colloidal forms of the trace metals.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067317808071147
|
“Grazing-exit particle-induced X-ray emission analysis with extremely low background”. Tsuji K, Spolnik Z, Wagatsuma K, Van Grieken RE, Vis RD, Analytical chemistry 71, 5033 (1999). http://doi.org/10.1021/AC990568U
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990568U
|
“Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysis”. Wouters LC, Van Grieken RE, Linton RW, Bauer CF, Analytical chemistry 60, 2218 (1988). http://doi.org/10.1021/AC00171A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00171A011
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
“Analysis of lateritic material from Cerro impacto by instrumental neutron activation employing a low-energy photon semiconductor and a high-energy Ge(Li) detector”. LaBrecque JJ, Beusen JM, Van Grieken RE, Applied spectroscopy 40, 140 (1986). http://doi.org/10.1366/0003702864509600
Abstract: Nineteen elements were determined in four different grain size fractions of a bulk geological material from Cerro Impacto for a study of the physical (mechanical) concentration process of different elements based upon the hardness of the different minerals. The analysis was performed by excitation of the sample with a high, slow neutron flux followed by gamma-ray spectroscopy with both a conventional Ge(Li) high-energy detector and a low-energy photon detector (LEPD). The accuracy of this method was studied with the use of two standard reference materials, SY-2 and SY-3, which are similar to the real samples. The values determined were also compared with a secondary target x-ray fluorescence method for all the elements that were suitable to both methods. Actually, the x-ray fluorescence method was found to be more complementary than competitive.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/0003702864509600
|
“Composition and size of individual particles from a gold mine atmosphere”. Annegarn HJ, Storms H, Van Grieken RE, Booth-Jones PA, Mining science &, technology 5, 111 (1987). http://doi.org/10.1016/S0167-9031(87)90345-8
Abstract: Airborne dust particles were collected in a return airway of a South African gold mine using a 7-stage, single-orifice cascade impactor. Between 70 and 130 individual particles were analysed on each stage using automated electron-probe x-ray microanalysis (EPXMA). Particle size and shape parameters are given for different classes of particles sorted by elemental composition. Silicon-rich particles are the most abundant overall, while chlorine-rich particles dominate (up to 80%) in the range 0.21.0 μm. It is shown that EPXMA characterisation of particles can be used to infer relative contributions of various particle sources and dust generating processes to the total dust concentrations in mine atmospheres. An understanding of the nature and source of particles is essential for any source control strategy. We conclude that the EPXMA technique merits inclusion in the repertoire of techniques used for characterising underground dust.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0167-9031(87)90345-8
|
“Determination of methanesulfonic acid and non-sea-salt sulfate in single marine aerosol particles”. Kolaitis LN, Bruynseels FJ, Van Grieken RE, Andreae MO, Environmental science and technology 23, 236 (1989). http://doi.org/10.1021/ES00179A018
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00179A018
|
“Enrichment of trace metals in water by adsorption on activated carbon”. Vanderborght BM, Van Grieken RE, Analytical chemistry 49, 311 (1977)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
“Geochemistry of suspended matter from the baltic sea : 1 : results of individual particle characterization by automated electron microprobe”. Bernard PC, Van Grieken RE, Brügmann L, Marine chemistry 26, 155 (1989). http://doi.org/10.1016/0304-4203(89)90058-3
Abstract: Automated electron probe X-ray microanalysis was used to characterize some 15 000 individual suspension particles from 50 samples of suspended matter collected from different depths at 18 stations throughout the Baltic Sea and the transient area to the North Sea. For each particle, 14 minor and major elements were determined and size information data were obtained. To process this huge amount of results, multivariate analysis techniques were invoked: the particles were classified into specific types and the abundance variations of these groups were studied. It appeared that 80% of all investigated particles contained mostly silicon, and seemed to consist of quartz, and K-rich and Fe-rich aluminosilicates. The abundance of BaSO4 particles averaged 5% throughout the Baltic Sea, but amounted to up to 44% at some stations. The abundance of the Fe-rich particles varied significantly with location and depth, and averaged ∼ 4%. They were often found to be associated with significant amounts of P. Both of these particle types and the Mn-rich particles are thought to be mainly authigenic. Calcium carbonate particles are more abundant towards the North Sea (which seems to act as a source). Principal component analysis of the data revealed that most of the compositional variability can be explained by differences between deep and surface waters and by the influences of inflowing North Sea waters. Additional information about the types and sources of the suspended matter in the Baltic Sea was gained from the comparison and correlation of the single particle results with different fractions of the bulk concentrations of elements such as Al, Ca, Mn, Fe, Zn and Ba.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(89)90058-3
|
“Heavy metal contamination in sediments from the Belgian coast and Scheldt estuary”. Araújo MFD, Bernard PC, Van Grieken RE, Marine pollution bulletin 19, 269 (1988). http://doi.org/10.1016/0025-326X(88)90597-8
Abstract: Sixty-two samples of total sediments and the separated clay/silt size fractions were analysed by energy-dispersive X-ray fluorescence spectrometry to evaluate the pollution level and the trends in samples collected along the Belgian coast over a period of 6 yr and at four stations located in the Scheldt estuary where two of these were sampled periodically for 4 yr. Three correction methods for grain size effects were applied, either to the bulk sediment samples or to the clay/silt size fractions, and the results were compared. Local variations on the concentrations in some of the elements determined were used to establish whether they result from an anthropogenic or natural origin. The level of pollution was assessed as a function of the location, sampling date, and depth.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0025-326X(88)90597-8
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Preconcentration and XRF-determination of heavy metals in hair from Sudanese populations”. Eltayeb MAH, Van Grieken RE, Journal of radioanalytical and nuclear chemistry 131, 331 (1989). http://doi.org/10.1007/BF02060598
Abstract: Energy-dispersive X-ray fluorescence analysis was applied for the analysis of hair. The hair samples were digested in a mixture of nitric and perchloric acid and the heavy metals were precipitated with ammonium pyrrolidine dithiocarbamate. The accuracy, precision and recovery of the method for the elements Fe, Ni, Cu, Zn and Pb were evaluated through the analysis of a standard hair sample. The procedure was applied to the analysis of hair from an occupationally exposed group of Sudanese workers and a control group. The hair of the exposed group showed a range of 80550 ppm Fe, 612 ppm Cu, 57190 ppm Zn and 703700 ppm Pb, while that of the control group had a range of 60310 ppm Fe, 722 ppm Cu, 89170 ppm Zn and 317 ppm Pb.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02060598
|
“Atomic number correction in electron probe X-ray microanalysis of curved samples and particles”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2798 (1984). http://doi.org/10.1021/AC00278A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00278A036
|
“Bremsstrahlung background in electron-probe X-ray-microanalysis of thin films”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 57, 2885 (1985). http://doi.org/10.1021/AC00291A032
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00291A032
|
“Grazing exit electron probe microanalysis for surface and particle analysis”. Tsuji K, Wagatsuma K, Nullens R, Van Grieken RE, Analytical chemistry 71, 2497 (1999). http://doi.org/10.1021/AC990075P
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC990075P
|
“Absorption correction via scattered radiation in energy-dispersive X-ray fluorescence analysis for samples of variable composition and thickness”. Van Dyck PM, Van Grieken RE, Analytical chemistry 52, 1859 (1980). http://doi.org/10.1021/AC50062A020
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50062A020
|
“Composition dependence of Bremsstrahlung background in electron-probe x-ray microanalysis”. Markowicz AA, Van Grieken RE, Analytical chemistry 56, 2049 (1984). http://doi.org/10.1021/AC00276A016
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00276A016
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
“X-ray spectrometry”. Szalóki I, Török SB, Ro C-U, Injuk J, Van Grieken RE, Analytical chemistry 72, 211 (2000). http://doi.org/10.1021/A1000018H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/A1000018H
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|