“Fluorescent tomography of metals in fly-ash particles at beamline L”. Vincze L, Vekemans B, Janssens K, Adams F, Haller M, HASYLAB Jahresbericht 1997 1, 959 (1998)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Fluorescent tomography of phantom samples at the beamline L”. Vekemans B, Vincze L, Vittiglio G, Janssens K, Adams F, HASYLAB Jahresbericht (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Future of m-XRF”. Adams F, Janssens K page 370 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Bruijnen Y, Caen JMA, Cagno S, Janssens K, et al. (2012) Getekend Jan R. : Jan Rombouts, een renaissancemeester herontdekt. 207 p
Keywords: ME2 Book as editor or co-editor; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Glass trade in Antwerp during the 15th through 17th century”. de Raedt I, Janssens K, Veeckman J, Adriaens A, Adams F page 38 (2000).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“High-E scanning m-XRF experiment on test paintings”. Dik J, Janssens K, van der Snickt G, Wallert A, Rickers K, Falkenberg G page 1589 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“High-resolution desktop microcomputed tomography for the evaluation of reducing treatments on historical glass suffering from manganese browning”. Nuyts G, Cagno S, Jaroszewicz J, Wouters H, De Vis K, Caen J, Janssens K page 201 (2013).
Abstract: Historical glass, especially non-durable mediaeval glass, can undergo corrosion. This sometimes results in the formation of dark-coloured manganese-rich inclusions or stains that reduce the transparency of the glass. A conservation treatment with reducing or chelating agents may be considered with the aim of improving the transparency. In this paper, high-resolution desktop microcomputed tomography (µCT) is used in combination with element-specific twodimensional imaging methods for in situ monitoring of manganese removal by hydroxylamine hydrochloride from an archaeological stained-glass sample suffering from manganese browning and from artificially corroded model glass samples. µCT also proved itself useful for the study of the (re-)penetration of manganese into the gel layer during artificial corrosion of a model glass.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
“High-resolution X-ray fluorescence micro-tomography on single sediment particles”. Vincze L, Vekemans B, Szalóki I, Janssens K, Van Grieken R, Feng H, Jones KW, Adams F page 240 (2002).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 11
DOI: 10.1117/12.452865
|
“ID18F: a new X-ray microprobe end station”. Somogyi A, Drakopoulos M, Vincze L, Vekemans B, Camerani C, Janssens K, Snigirev A, Adams F, ESRF highlights 2001 , 96 (2002)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Identification of artificial orpiment in the interior decorations of the Japanese tower in Laeken, Brussels, Belgium”. Vermeulen M, Sanyova J, Janssens K, Heritage science 3, Unsp 9 (2015). http://doi.org/10.1186/S40494-015-0040-7
Abstract: In this paper, we used a multi-technique approach in order to identify the arsenic sulfide pigment used in the decorative panels of the Japanese tower in Laeken, Belgium. Our attention was drawn to this particular pigment because of its relatively good conservation state, despite its known tendency to fade over time when exposed to light. The pigment was used with different painting techniques, bound with oil and urushi in the lacquers and with an aqueous binder in the mat relief panels. In the latter case it is always applied as an underlayer mixed with ultramarine blue. This quite unusual pigment mixture also shows a good state of preservation. In this study, the orpiment used for the Japanese tower has been identified as an amorphous arsenic sulfide glass (AsxSx) with the aid of light microscopy, PLM, SEM-EDX and Raman microscopy. The pigment features different degrees of As4S4 monomer units in its structure, also known as realgar-like nano-phases. This most likely indicates different synthesis processes as the formation of these As4S4 monomers is dependent of the quenching temperature (Tq) to which the artificial pigment is exposed during the preparation phase.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 17
DOI: 10.1186/S40494-015-0040-7
|
“The identification of chromophores in ancient glass by the use of UV-VIS-NIR spectroscopy”. Meulebroeck W, Baert K, Wouters H, Cosyns P, Ceglia A, Cagno S, Janssens K, Nys K, Terryn H, Thienpont H, Proceedings of the Society of Photo-optical Instrumentation Engineers 7726, 77260d (2010). http://doi.org/10.1117/12.853666
Abstract: In this publication optical spectroscopy is considered to be a supplementary technique to study ancient colored glass. It results from a systematic study of the UV-VIS-NIR transmission spectra of intentionally colored glass fragments from various archaeological and historical sites and dated from the Roman period to the 21th century AD. The main goal consists of defining optical sensing parameters for this type of material. The considered colorants are iron, cobalt, manganese, copper and chromium. It is proved that many cases exist where optical spectroscopy can be seen as a straightforward, non-destructive, low-cost and in-situ applicable technique in identifying authentic material or to obtain information about the origin of the material. Possible sensing parameters are defined as the absence/presence of absorption bands characteristic for a specific coloring metal oxide and the spectral position of these bands. These parameters could reveal information about the applied furnace conditions and/or to the composition of the glass matrix. It is shown that the cobalt absorption band situated around 535 nm for soda rich glasses (Roman and industrial times) is shifted towards 526 nm for potash rich glasses (medieval and post-medieval times).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 10
DOI: 10.1117/12.853666
|
“Identification of the geochemical forms of CR, Zn, Ni, Pb, V, and Cu in an industrial polluted soil by combined μ-XRF/μ-XRD and μ-XANES”. Terzano R, Spagnuolo M, Ruggiero P, Vekemans B, de Nolf W, Janssens K, Fiore S, Falkenberg G (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
“In-vivo 3D mapping and local speciation of Se compounds in roots and leaves of Allium Cepa”. Janssens K, Proost K, Wysocka A, Bulska E, Wierzbicka M (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Introduction and overview”. Janssens K, Van Grieken R page 1 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Investigation of the chemical state and 3D distribution of Mn in corroded glass fragments”. Proost K, Schalm O, Janssens K, Van Dyck D (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
“Jan Davidsz. de Heem (1606-1684): a technical examination of fruit and flower still lifes combining MA-XRF scanning, cross-section analysis and technical historical sources”. De Keyser N, van der Snickt G, Van Loon A, Legrand S, Wallert A, Janssens K, Heritage science 5, 38 (2017). http://doi.org/10.1186/S40494-017-0151-4
Abstract: This article discusses the technical examination of five flower and fruit still life paintings by the seventeenth century artist Jan Davidsz. de Heem (1606-1684). The painter is known for his meticulously composed and finely detailed still life paintings and is a master in imitating the surface textures of various fruits, flowers, and objects. Macro X-ray fluorescence (MA-XRF) scanning experiments were supplemented with a study of paint cross-sections and contemporary art technical sources with the aim of reconstructing the complex build-up of the overall lay-in of the composition and individual subjects. MA-XRF provided information on the distribution of key chemical elements present in painting materials and made it possible to recapture evidence of the different phases in the artist's working methods: from the application of the ground layers, to De Heem's characteristic oval-shaped underpaintings, and finally, the superposition of multiple paint layers in the working up of the paintings. SEM-EDX analysis of a limited number of paint cross-sections complemented the chemical images with local and layer-specific information on the microscale, providing more accuracy on the layer sequence and enabling the study of elements with a low atomic number for which the non-invasive technique is less sensitive. The results from this technical examination were in addition compared with recipes and paint instructions, to obtain a better understanding of the relation between the general practice and actual painting technique of Jan Davidsz. de Heem. Ultimately, this combined approach uncovered new information on De Heem's artistic practice and demonstrated the complementarity of the methods.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 5
DOI: 10.1186/S40494-017-0151-4
|
“A laboratory mu-XRF spectrometer employing capillary optics”. Janssens K, Vekemans B, Rindby A, Vincze L, Adams F, , 159 (1995)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“MA-XRF imaging on Rene Magritte's La condition humaine : insights into the artist's palette and technique and the discovery of a third quarter of La pose enchantee”. da Silva AT, Legrand S, van der Snickt G, Featherstone R, Janssens K, Bottinelli G, Heritage science 5, 37 (2017). http://doi.org/10.1186/S40494-017-0150-5
Abstract: Magritte's composition La condition humaine, 1935 was found to conceal under its paint layers an entire quarter of a lost composition by the artist, until recently only known from a small black/white catalogue illustration-La pose enchantee, 1927. This study is the latest contribution to the discovery of the artist's missing painting, now known to have been cut into four parts and re-used by Magritte as the support for new compositions. Non-destructive analytical and examination methods and specifically macroscopic X-ray fluorescence (MAXRF) scanning and conventional X-ray radiography (XRR) were the two non-destructive analytical and examination methods used to study both compositions and add to the existing knowledge on the artist's palette during both periods. The first method is capable of identifying the presence and the distribution of key chemical elements present in artists' materials. In some instances elemental mapping provided useful information on the hidden painting, but conventional X-ray radiography (XRR) enabled a better visualisation of the form and paint application of the underlying composition. Furthermore, the turnover edges of the canvas reveal after over 80 years the artist's palette directly to the viewer. Additional XRF scanning of this exposed paint has confirmed and added to the existing research published to date of this lost painting, including a proposed colour reconstruction, but at the same time highlighting the need for further analytical research involving both non-destructive point analysis and the use of paint samples.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 7
DOI: 10.1186/S40494-017-0150-5
|
“Macro X-ray fluorescence (MA-XRF) scanning : a new and efficient method for documenting stained-glass panels”. Caen J, Legrand S, van der Snickt G, Janssens K, (2015)
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
“Methods 4: elemental analysis (AAS/AES/X-ray fluorescence)”. Janssens K (2003).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Micro-analysis of artists' pigments by grazing-emission X-ray fluorescence spectrometry”. Claes M, van Ham R, Janssens K, Van Grieken R, Klockenkämper R, von Bohlen A, Advances in X-ray analysis 41, 262 (1999)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Micro-heterogeneity study of trace elements in BCR CRM 680 by means of synchrotron micro-XRF”. Kempenaers L, de Koster C, van Borm W, Janssens K, Fresenius' journal of analytical chemistry 369, 733 (2001). http://doi.org/10.1007/S002160000679
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 15
DOI: 10.1007/S002160000679
|
Kempenaers L, Vincze L, Vekemans B, Janssens K, Adams F, Somogyi A, Drakopoulos M, Simionovici AS (2004) Micro-heterogeneity study of trace elements in reference materials. 132 p
Keywords: MA3 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Micro-XANES determination of ferric iron and its application in thermobarometry”. Schmid R, Wilke M, Ober R, Dong S, Janssens K, Falkenberg G, Franz L, Gaab A, Lithos 70, 381 (2003). http://doi.org/10.1016/S0024-4937(03)00107-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0024-4937(03)00107-5
|
Janssens KHA, Adams FCV, Rindby A (2000) Microscopic X-ray fluorescence analysis. 419 p
Keywords: MA1 Book as author; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Microscopic X-ray fluorescence analysis”. Janssens K, Vincze L, Rubio J, Bernasconi G, Adams F, Journal of analytical atomic spectrometry 9, 151 (1994). http://doi.org/10.1039/JA9940900151
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/JA9940900151
|
“Monte Carlo simulation for X-ray fluorescence spectroscopy”. Vincze L, Janssens K, Vekemans B, Adams F page 435 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Monte Carlo simulation of conventional and synchrotron energy-dispersive X-ray spectrometers”. Janssens K, Vincze L, van Espen P, Adams F, X-ray spectrometry 22, 234 (1993). http://doi.org/10.1002/XRS.1300220412
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300220412
|
“Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments”. Vincze L, Janssens K, Vekemans B, Adams F page 328 (1999).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.363736
|