“Modeling study on the influence of the pressure on a dielectric barrier discharge microplasma”. Martens T, Bogaerts A, Brok WJM, van der Mullen JJAM, Journal of analytical atomic spectrometry 22, 1003 (2007). http://doi.org/10.1039/b704903j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b704903j
|
“Nanosecond laser ablation of Cu: modeling of the expansion in He background gas, and comparison with expansion in vacuum”. Bogaerts A, Chen Z, Journal of analytical atomic spectrometry 19, 1169 (2004). http://doi.org/10.1039/b402946a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 39
DOI: 10.1039/b402946a
|
“Numerical simulation analysis of flow patterns and particle transport in the HEAD laser ablation cell with respect to inductively coupled plasma spectrometry”. Lindner H, Autrique D, Pisonero J, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 25, 295 (2010). http://doi.org/10.1039/b920905k
Abstract: The present study analyses a specific laser ablation cell, the High Efficiency Aerosol Dispersion (HEAD) cell (see J. Pisonero et al., J. Anal. At. Spectrom., 2006, 21, 922931), by means of computational fluid dynamics (CFD) simulations. However, this cell consists of different modular parts, therefore, the results are probably of interest for the further development of other ablation cells. In the HEAD cell, the ablation spot is positioned below an orifice in the ceiling of the sample chamber. The particle transport through this orifice has been analysed for a ceiling height of 0.8 mm. The critical velocity for the onset of particle losses was found to be independent on the ejection angle at the crater spot. The deceleration of the particles can be described as the stopping in an effectively steady gas. Particle losses were negligible in this modular part of the cell at the evaluated laser ablation conditions. The transport efficiency through the Venturi chamber was investigated for different sample gas flow rates. In this case, it was found that small particles were predominantly lost at low flow rates, the large particles at higher flow rates. Making use of the simulation results, it was possible to design a modification of the HEAD cell that results in extremely short calculated washout times. The simulations yielded a signal of less than 10 ms, which was produced by more than 99% of the introduced mass.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 16
DOI: 10.1039/b920905k
|
“Occurrence of gas flow rotational motion inside the ICP torch : a computational and experimental study”. Aghaei M, Flamigni L, Lindner H, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 29, 249 (2014). http://doi.org/10.1039/c3ja50302j
Abstract: An inductively coupled plasma, connected to the sampling cone of a mass spectrometer, is computationally investigated. The occurrence of rotational motion of the auxiliary and carrier gas flows is studied. The effects of operating parameters, i.e., applied power and gas flow rates, as well as geometrical parameters, i.e., sampler orifice diameter and injector inlet diameter, are investigated. Our calculations predict that at higher applied power the auxiliary and carrier gas flows inside the torch move more forward to the sampling cone, which is validated experimentally for the auxiliary gas flow, by means of an Elan 6000 ICP-MS. Furthermore, an increase of the gas flow rates can also modify the occurrence of rotational motion. This is especially true for the carrier gas flow rate, which has a more pronounced effect to reduce the backward motion than the flow rates of the auxiliary and cooling gas. Moreover, a larger sampler orifice (e.g., 2 mm instead of 1 mm) reduces the backward flow of the auxiliary gas path lines. Finally, according to our model, an injector inlet of 2 mm diameter causes more rotations in the carrier gas flow than an injector inlet diameter of 1.5 mm, which can be avoided again by changing the operating parameters.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/c3ja50302j
|
“Plasma diagnostics and numerical simulations: insight into the heart of analytical glow discharges”. Bogaerts A, Journal of analytical atomic spectrometry 22, 13 (2007). http://doi.org/10.1039/b611436a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b611436a
|
“Relative sensitivity factors in glow discharge mass spectrometry: the role of charge transfer ionization”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 11, 841 (1996). http://doi.org/10.1039/ja9961100841
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.466
Times cited: 38
DOI: 10.1039/ja9961100841
|
“Role of laser-induced melting and vaporization of metals during ICP-MS and LIBS analysis, investigated with computer simulations and experiments”. Bleiner D, Chen Z, Autrique D, Bogaerts A, Journal of analytical atomic spectrometry 21, 910 (2006). http://doi.org/10.1039/b602800d
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b602800d
|
“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
“Surface analysis of halide distributions in complex AgX microcrystals by imaging time-of-flight SIMS (TOF-SIMS)”. Verlinden G, Gijbels R, Geuens I, de Keyzer R, Journal of analytical atomic spectrometry 14, 429 (1999). http://doi.org/10.1039/a807276k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 10
DOI: 10.1039/a807276k
|
“Temporal and spatially resolved laser-scattering plasma diagnostics for the characterization of a ms-pulsed glow discharge”. Gamez G, Bogaerts A, Hieftje GM, Journal of analytical atomic spectrometry 21, 350 (2006). http://doi.org/10.1039/b511764j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b511764j
|
“Vibrational level population of nitrogen impurities in low-pressure argon glow discharges”. Simon P, Bogaerts A, Journal of analytical atomic spectrometry 26, 804 (2011). http://doi.org/10.1039/c0ja00179a
Abstract: The vibrational level populations of the electronic ground state of the nitrogen molecule have been calculated for typical glow discharge conditions in argonnitrogen mixtures with nitrogen concentrations between 0.1 and 1%. Stationary solutions of the master equations of the vibrational levels have been obtained using numerical methods. The main mechanisms responsible for the population and depopulation of the vibrational levels, and for the overall shape of the vibrational distribution function are pointed out. It has been found that vibrationvibration collisions play only a minor role and therefore the population of the vibrational levels is basically determined by the electron temperature.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 6
DOI: 10.1039/c0ja00179a
|
“Computer simulation of an analytical direct current glow discharge in argon: influence of the cell dimensions on the plasma quantities”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 12, 751 (1997)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
|
“Particle transport through an inductively coupled plasma torch: elemental droplet evaporation”. Aghaei M, Bogaerts A, Journal of analytical atomic spectrometry 31, 631 (2016). http://doi.org/10.1039/C5JA00162E
Abstract: We studied the transport of copper droplets through an inductively coupled plasma, connected to the sampling cone of a mass spectrometer, by means of a computational model. The sample droplets are followed until they become evaporated. They are inserted as liquid particles from the central inlet and the effects of injection position (i.e. “on” and “off” axis), droplet diameter, as well as mass loading flow rate are investigated. It is shown that more “on-axis” injection of the droplets leads to a more straight path line, so that the droplets move less in the radial direction and are evaporated more on the central axis, enabling a better sample transfer efficiency to the sampler cone. Furthermore, there are optimum ranges of diameters and flow rates, which guarantee the proper position of evaporation along the torch, i.e. not too early, so that the sample can get lost in the torch, and not too late, which reduces the chance of becoming ionized before reaching the sampler.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/C5JA00162E
|
“Inductively coupled plasma-mass spectrometry: insights through computer modeling”. Bogaerts A, Aghaei M, Journal of analytical atomic spectrometry 32, 233 (2017). http://doi.org/10.1039/C6JA00408C
Abstract: In this tutorial review paper, we illustrate how computer modeling can contribute to a better insight in inductively coupled plasma-mass spectrometry (ICP-MS). We start with a brief overview on previous efforts, studying the fundamentals of the ICP and ICP-MS, with main focus on previous modeling activities. Subsequently, we explain in detail the model that we developed in previous years, and we show typical calculation results, illustrating the plasma characteristics, gas flow patterns and the sample transport, evaporation and ionization. We also present the effect of various experimental parameters, such as operating conditions, geometrical aspects and sample characteristics, to illustrate how modeling can help to elucidate the optimal conditions for improved analytical performance.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 14
DOI: 10.1039/C6JA00408C
|
“A novel gas inlet system for improved aerosol entrainment in laser ablation inductively coupled plasma mass spectrometry”. Bleiner D, Altorfer H, Journal of analytical atomic spectrometry (2005). http://doi.org/10.1039/B505248C
Abstract: In order to minimize the dead volume in large cells for laser ablation inductively coupled plasma mass spectrometry, and improve the aerosol entrainment characteristics, the gas inlet nozzle has been set in rotation. This allowed a wider volume to be swept than with the traditional static inlet nozzle approach. Therefore, sensitivity combined with site-to-site repeatability was improved by a factor of two, together with minimization of aerosol loss within the cell and signal dispersion.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/B505248C
|
“Overcoming pulse mixing and signal tailing in laser ablation inductively coupled plasma mass spectrometry depth profiling”. Bleiner D, Belloni F, Doria D, Lorusso A, Nassisi V, Journal of analytical atomic spectrometry (2005). http://doi.org/10.1039/B509379C
Abstract: The laser ablation-induced plasma was used as a composition-con trolled source for ion implantation in Si crystals. Then, laser ablation in combination with inductively coupled plasma mass spectrometry was used for the elemental depth profiling of the implanted samples. Monte Carlo simulations permitted us to conclude that a depth resolution of tens of nm would be necessary to define the shape of the implantation profiles, as is obtained using XPS and RBS, whereas a hundred nm depth resolution is sufficient to determine the total implanted dose. The detection power of LA-ICP-MS would routinely allow rapid analytical control on the trace level implanted dose. Nevertheless, this technique is limited in terms of depth profiling resolution due to pulse mixing and signal tailing induced during the aerosol transport. Raw signal processing procedures were developed for the minimization of shapeline dispersion, deconvolution of pulse mixing and more appropriate assessment of the implanted profiles. Shapeline dispersion could be corrected for by determining the signal waning constant and implementing this information for a non-affine alibi transformation of the LA-ICP-MS signal traces. Pulse mixing deconvolution was attained with an algorithm that considered accumulated signal intensity due to pulse-on-pulse stacking, i.e., the latest pulse on top of all antecedent individual pulses' exponential tails proportionally.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 26
DOI: 10.1039/B509379C
|
“Macroscale computer simulations to investigate the chemical vapor deposition of thin metal-oxide films”. Neyts E, Bogaerts A, de Meyer M, van Gils S, Surface and coatings technology 201, 8838 (2007). http://doi.org/10.1016/j.surfcoat.2007.04.102
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.589
Times cited: 5
DOI: 10.1016/j.surfcoat.2007.04.102
|
“Modeling of gas discharge plasmas: What can we learn from it?”.Bogaerts A, de Bleecker K, Kolev I, Madani M, Surface and coatings technology 200, 62 (2005). http://doi.org/10.1016/j.surfcoat.2005.02.057
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.589
Times cited: 11
DOI: 10.1016/j.surfcoat.2005.02.057
|
“Detection of CO2 using CNT-based sensors: Role of Fe catalyst on sensitivity and selectivity”. Tit N, Al Ezzi MM, Abdullah HM, Yusupov M, Kouser S, Bahlouli H, Yamani ZH, Materials chemistry and physics 186, 353 (2017). http://doi.org/10.1016/J.MATCHEMPHYS.2016.11.006
Abstract: The adsorption of CO2 on surfaces of graphene and carbon nanotubes (CNTs), decorated with Fe atoms, are investigated using the self-consistent-charge density-functional tight-binding (SCC-DFTB) method, neglecting the heat effects. Fe ad-atoms are more stable when they are dispersed on hollow sites. They introduce a large density of states at the Fermi level (N-F); where keeping such density low would help in gas sensing. Furthermore, the Fe ad-atom can weaken the C=O double bonds of the chemisorbed CO2 molecule, paving the way for oxygen atoms to drain more charges from Fe. Consequently, chemisorption of CO2 molecules reduces both N-F and the conductance while it enhances the sensitivity with the increasing gas dose. Conducting armchair CNTs (ac-CNTs) have higher sensitivity than graphene and semiconducting zigzag CNTs (zz-CNT5). Comparative study of sensitivity of ac-CNT-Fe composite towards various gases (e.g., O-2, N-2, H-2, H2O, CO and CO2) has shown high sensitivity and selectivity towards CO, CO2 and H2O gases. (C) 2016 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.084
Times cited: 17
DOI: 10.1016/J.MATCHEMPHYS.2016.11.006
|
“Trial solution and critical frequency to the singly quantized vortex in big Bose-Einstein condensates”. Xu Y, Jia DJ, Chen ZY, Modern physics letters B 20, 995 (2006). http://doi.org/10.1142/S0217984906011104
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.617
DOI: 10.1142/S0217984906011104
|
“The mode-deviation effect of trapped spinor bose gas beyond mean field theory”. Xu Y, Jia D-J, Chen Z, Gao Y, Li F-S, International journal of modern physics: B: condensed matter physics, statistical physics, applied physics 18, 1339 (2004). http://doi.org/10.1142/S0217979204024719
Abstract: The deviation effect of spinor mode from the single-mode for a spin-1 Bose gas of trapped atoms is studied beyond the mean field theory. Based on the effective Hamiltonian with nondegenerated level of the collective spin states, the splitting level of the system energy due to the deviation effect has been calculated. For the large condensates of (87)Rb and (23)Na with atom number N > 10(5), the splitting fraction of the energy, arising from the magnetization exhibited by the trapped Bose gas, is found to have a typical order of (10(-4) similar to 10(-8)), decreasing as N(-2) for (87)Rb and increasing as -N(-2) for 23 Na, respectively.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 0.736
Times cited: 1
DOI: 10.1142/S0217979204024719
|
“Sustainability analysis of methane-to-hydrogen-to-ammonia conversion by integration of high-temperature plasma and non-thermal plasma processes”. Osorio-Tejada J, van't Veer K, Long NVD, Tran NN, Fulcheri L, Patil BS, Bogaerts A, Hessel V, Energy Conversion And Management 269, 116095 (2022). http://doi.org/10.1016/j.enconman.2022.116095
Abstract: The Covid era has made us aware of the need for resilient, self-sufficient, and local production. We are likely willing to pay an extra price for that quality. Ammonia (NH3) synthesis accounts for 2 % of global energy production and is an important point of attention for the development of green energy technologies. Therefore, we propose a thermally integrated process for H2 production and NH3 synthesis using plasma technology, and we evaluate its techno-economic performance and CO2 footprint by life cycle assessment (LCA). The key is to integrate energy-wise a high-temperature plasma (HTP) process, with a (low-temperature) non-thermal plasma (NTP) process and to envision their joint economic potential. This particularly means raising the temperature of the NTP process, which is typically below 100 ◦ C, taking advantage of the heat released from the HTP process. For that purpose, we proposed the integrated process and conducted chemical kinetics simulations in the NTP section to determine the thermodynamically feasible operating window of this novel combined plasma process. The results suggest that an NH3 yield of 2.2 mol% can be attained at 302 ◦ C at an energy yield of 1.1 g NH3/kWh. Cost calculations show that the economic performance is far from commercial, mainly because of the too low energy yield of the NTP process. However, when we base our costs on the best literature value and plausible future scenarios for the NTP energy yield, we reach a cost prediction below 452 $/tonne NH3, which is competitive with conventional small-scale Haber-Bosch NH3 synthesis for distributed production. In addition, we demonstrate that biogas can be used as feed, thus allowing the proposed integrated reactor concept to be part of a biogas-to-ammonia circular concept. Moreover, by LCA we demonstrate the environmental benefits of the proposed plant, which could cut by half the carbon emissions when supplied by photovoltaic electricity, and even invert the carbon balance when supplied by wind power due to the avoided emissions of the carbon black credits.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 10.4
DOI: 10.1016/j.enconman.2022.116095
|
“Feasibility study of a small-scale fertilizer production facility based on plasma nitrogen fixation”. Manaigo F, Rouwenhorst K, Bogaerts A, Snyders R, Energy Conversion and Management 302, 118124 (2024). http://doi.org/10.1016/j.enconman.2024.118124
Keywords: A1 Journal Article; Plasma-based nitrogen fixation Haber-Bosch Feasibility study Fertilizer production; Plasma, laser ablation and surface modeling Antwerp (PLASMANT) ;
Impact Factor: 10.4
DOI: 10.1016/j.enconman.2024.118124
|
“A critical comparison of MINDO/3, MNDO, AM1 and PM3 for a model problem: carbon clusters C2-C10. An ad hoc reparametrization of MNDO well suited for the accurate prediction of their spectroscopic constants”. Martin JML, François JP, Gijbels R, Journal of computational chemistry 12, 52 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.589
Times cited: 76
|
Friedman PC, Miller V, Fridman G, Lin A, Fridman A (2017) Successful treatment of actinic keratoses using nonthermal atmospheric pressure plasma : a case series. 349–350
Keywords: L1 Letter to the editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1016/J.JAAD.2016.09.004
|
“High-resolution electron microscopy and electron energy-loss spectroscopy of giant palladium clusters”. Oleshko V, Volkov V, Gijbels R, Jacob W, Vargaftik M, Moiseev I, Van Tendeloo G, Zeitschrift für Physik : D : atoms, molecules and clusters 34, 283 (1995). http://doi.org/10.1007/BF01437574
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Electron microscopy for materials research (EMAT)
Times cited: 22
DOI: 10.1007/BF01437574
|
“Ab initio spectroscopy and thermochemistry of the BN molecule”. Martin JML, François JP, Gijbels R, Zeitschrift für Physik : D : atoms, molecules and clusters 21, 47 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 17
|
“A comparative study of carbocyanine dyes measured with TOF-SIMS and other mass spectrometric techniques”. Adriaensen L, Vangaever F, Gijbels R, Applied surface science 231/232, 348 (2004). http://doi.org/10.1016/j.apsusc.2004.03.091
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 7
DOI: 10.1016/j.apsusc.2004.03.091
|
“Depth profiling of ZrO2/SiO2/Si stacks : a TOF-SIMS and computer simulation study”. Ignatova VA, Conard T, Möller W, Vandervorst W, Gijbels R, Applied surface science 231/232, 603 (2004). http://doi.org/10.1016/j.apsusc.2004.03.121
Abstract: This study is dedicated to a better understanding of the processes occurring under ion bombardment of ultra-thin ZrO2/SiO2/Si gate dielectric stacks. Complex-shaped depth profiles were obtained by using TOF-SIMS with dual beam (500 eV for sputtering and 10 keV for analysis) Ar+ ions. The SIMS intensities of all the elements depend critically on the amount of oxygen at any moment of the sputtering process. Increased intensity is observed at the surface and at the ZrO2/SiO2 interface. A long tail of the Zr signal is present in the Si substrate, even after the second (SiO2/Si) interface, and a double bump structure in the Zr-90 and ZrO dimer is observed, which is more pronounced with increasing thickness of the interfacial SiO2 layer. Computer simulations using the dynamic Monte Carlo code (TRIDYN) are performed in order to distinguish the ion bombardment-induced effects from changes in the ionization degree. The original code is extended with simple models for the ionization mechanism and for the molecular yield during sputtering. Oxygen preferential sputtering at the surface and ballistic transport of Zr towards and through the interface are clearly demonstrated, but there is also evidence that due to recoil implantation oxygen gets piled-up near the ZrO2/SiO2 interface. (C) 2004 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 4
DOI: 10.1016/j.apsusc.2004.03.121
|
“Empirical evaluation of metal deposition for the analysis of organic compounds with static secondary ion mass spectrometry (S-SIMS)”. de Mondt R, Adriaensen L, Vangaever F, Lenaerts J, van Vaeck L, Gijbels R, Applied surface science 252, 6652 (2006). http://doi.org/10.1016/j.apsusc.2006.02.110
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.387
Times cited: 9
DOI: 10.1016/j.apsusc.2006.02.110
|