“Multi-element analysis of urine by energy-dispersive x-ray fluorescence spectrometry”. Vos L, Robberecht H, Van Dyck P, Van Grieken R, Analytica chimica acta 130, 167 (1981). http://doi.org/10.1016/S0003-2670(01)84161-1
Abstract: For multi-element analysis of human urine, 25-ml samples doped with yttrium as internal standard are evaporated gently and then ashed up to 460°C overnight. The residue is pelletized and analysed by energy-dispersive x-ray fluorescence. Acid addition to facilitate the digestion is not mandatory. Recoveries are nearly quantitative for traces of Fe, Ni, Cu, Zn and Sr, to a lesser extent for lead, but not for arsenic or selenium. The standard deviation per measurement is typically around 6%. The detection limits are such that some 10 elements can be determined simultaneously in normal urine, and possibly more in cases of importance to toxicology or industrial hygiene.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84161-1
|
“On the precision of oxygen determinations in steel by 14-MeVv neutron activation”. Van Grieken R, Speecke A, Hoste J, Analytica chimica acta 52, 275 (1970). http://doi.org/10.1016/S0003-2670(01)80957-0
Abstract: The precision of the 14-MeV neutron activation determination of oxygen in steel has been examined as a function of the oxygen content for a large number of steel and cast iron samples. The experimental and the statistically expected standard deviations have been compared. In the conditions used, 2.5 counts from 16N were registered for each p.p.m. of oxygen in the samples. The neutron flux was monitored by a simultaneously irradiated oxygen standard.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)80957-0
|
“Optimization of a simple spotting procedure for x-ray fluorescence analysis of waters”. Smits J, Van Grieken R, Analytica chimica acta 88, 97 (1977). http://doi.org/10.1016/S0003-2670(01)96053-2
Abstract: Several sample preparation methods for waters for energy-dispersive x.r.f. were examined, as well as the influence of sample size on the analytical characteristics. The most satisfactory simple, rapid method proved to be spotting of 1.5 ml of water sample on a Whatman-41 cellulose filter paper provided with a wax ring of 29-mm diameter and evaporating the water with an unheated air stream from underneath. Sensitivities are below 100 p.p.b. for most elements and often below 50 p.p.b. when the optimal secondary fluorescer is used. Accuracy and precision are usually in the 1520 % range. The method is applicable to many dilute aqueous solutions as is illustrated by analysis of industrial water samples and ashed biological material.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)96053-2
|
“Preconcentration methods for the analysis of water by X-ray spectrometric techniques”. Van Grieken R, Analytica chimica acta 143, 3 (1982). http://doi.org/10.1016/S0003-2670(01)95486-8
Abstract: All published procedures for multi-element preconcentration of trace elements, prior to x-ray fluorescence analysis of water, are reviewed and critically evaluated. Most preconcentration methods applied to the determination of single elements in water are also listed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)95486-8
|
“Preparation of conducting electrodes from biological samples for multi-element trace analysis by spark-source mass spectrometry or emission spectrometry”. Vos L, Van Grieken R, Analytica chimica acta 164, 83 (1984). http://doi.org/10.1016/S0003-2670(00)85619-6
Abstract: Four decomposition procedures frequently used for biological material (dry ashing, open wet digestion, wet digestion in a teflon bomb and low-temperature ashing) are optimized for the conversion of biological samples to conducting electrodes suitable for multi-element trace determinations by spark-source mass spectrometry or emission spectrometry. The optimized procedures are evaluated with respect to contamination, retention and preconcentration of the trace elements, homogeneity of the electrodes and precision of the final results. Both dry-ashing methods are prone to losses by volatilization; simple dry ashing suffers from contamination problems during electrode preparation. Wet digestion gives better precision; digestion with nitric/sulfuric acids in an open flask is the method of choice for most elements being simpler and giving lower blanks than the bomb method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85619-6
|
“Radio-isotope neutron activation analysis for vanadium, manganese and tungsten in alloy steels”. Lins Galdino SM, Costa Dantas C, Van Grieken R, Analytica chimica acta 196, 337 (1987). http://doi.org/10.1016/S0003-2670(00)83107-4
Abstract: An instrumental neutron activation method for V, Mn and W in alloy steels with a 241 Am/Be isotopic neutron source is described. The samples were irradiated to induce the nuclear reactions 51V(n, γ) 52V, 55Mn(n, γ)56Mn, and 186W(n, γ)187W. The activities were measured with a NaI(TI) detector. Interferences on the measured photopeaks were shown to be negligible by measuring the half-lives of 62V, 56Mn and 187W.These thre elementes were determined in the range 1.512.9% in special steels; manganese in the range 0.51.6% was measured in cast irons. Calibration was done by comparison with results from wet chemistry and x-ray fluorescence spectrometry. The processing times for the vanadium, manganese and tungsten determinations were 11 min, 3 h and 26.3 h, respectively, but these were reduced greatly by intoruding a scheme wherein six samples were simultaneously irradiated and the 56Mn and 187W nuclides were measured sequentially for a series of 66 samples. The average processing time was reduced to 45 min for tungsten with a precision of 4.0% and accuracy of 3.4% and 22.8 min for manganese with a precision of 3.8% and accuracy of 3.1%.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)83107-4
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
“Sample contamination from a commercial grinding unit”. Van Grieken R, Van de Velde R, Robberecht H, Analytica chimica acta 118, 137 (1980). http://doi.org/10.1016/S0003-2670(01)93724-9
Abstract: The contamination of ground samples by a commercially available Lovibond McCrone Micronizing Mill is discussed. Tracer and weighing experiments showed that abrasion of corundum grinding elements was important, introducing 620 mg of abrasion products per minute of wet grinding. Agate grinding elements were abraded at ⩽6 mg min-1. The abrasion products and grinding elements were analyzed by x-ray fluorescence, spark-source mass spectrometry and neutron activation analysis. Contamination in trace element analysis of geological materials is likely to be negligible for agate grinding elements and, except for a few transition metals, also for corundum grinding elements. Contamination of typical biological samples is significant for a few elements even when agate elements are used, and is absolutely prohibitive for trace analysis when corundum elements are used.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93724-9
|
“Simultaneous determination of chromium and silicon in steel by 14-mev neutron activation analysis”. Vandecasteele C, Van Grieken R, Hoste J, Analytica chimica acta 72, 31 (1974). http://doi.org/10.1016/S0003-2670(01)82945-7
Abstract: Chromium and silicon are determined simultaneously in steel by 14-MeV neutron activation analysis. The activities of 52V(Eγ=1.43 MeV,TView the MathML source=3.76 min) from 52Cr(n,p)52V and 28Al (Eγ=1.78 MeV; TView the MathML source=2.24 min) from 28Si(n,p)28Al are evaluated by mixed γ-ray spectrometry. The influence of manganese and phosphorus, the main interfering elements, is negligible for most stainless steels. The count rate should be limited, to avoid 52V pulse pile-up effects interfering in the 28Al energy region. Precisions in the 2-10% range are reached, depending on the concentrations, for a 10-min analysis time. Results for a series of steel samples are compared with industrial analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)82945-7
|
“Soil analysis by thin-film energy-dispersive X-ray fluorescence”. Van Grieken R, Van 't dack L, Costa Dantas C, Da Silveira Dantas H, Analytica chimica acta 108, 93 (1979). http://doi.org/10.1016/S0003-2670(01)93044-2
Abstract: Energy-dispersive x-ray fluorescence is advantageous for trace analysis of soils present as thin films. A target thickness of about 2 mg cm-2 provides a compromise between optimal sensitivity and minimal absorption effect or optimal accuracy. Sample preparation involves only suspending the finely ground soil in water and drying this suspension on a thin mylar foil glued on a ring that fits into the x.r.f. spectrometer. The effective sample weight present in the exciting beam area is computed from the scatter peaks, a method that cancels out target heterogeneity problems. High accuracy is demonstrated for many elements in reference soil and rock materials; a precision around 5% and a detection limit around 10 ppm can be achieved. As an illustration, results for 16 trace elements and preliminary interpretation are given for a series of pedologically important soil samples from Brasil.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)93044-2
|
“Study of inorganic ammonium compounds in individual marine aerosol particles by laser microprobe mass spectrometry”. Otten P, Bruynseels F, Van Grieken R, Analytica chimica acta 195, 117 (1987). http://doi.org/10.1016/S0003-2670(00)85654-8
Abstract: Ammonia is important in the atmosphere because it neutralizes acidic species. The relative importance of different inorganic ammonium compounds (chloride, nitrate and sulfate) in marine air chemistry was studied by single-particle characterization with the laser microprobe mass analyser. Standard aerosols were generated as a reference for compound identification, based on the fingerprint spectra obtained, and calculation of the relative sensitivity achieved for different ions in a marine aerosol matrix. The relative sensitivity for ammonium was low. Aerosol samples were collected in the Southern Bight of the North Sea under different meteorological conditions and examined for their ammonium compounds. Samples collected during an inversion period with continental influences showed a much higher content in all particles than samples collected under different meteorological conditions, where ammonium was mostly detected in the submicrometer particle-size range.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85654-8
|
“A study of the weathering of an historic building”. Leysen L, Roekens E, Komy Z, Van Grieken R, Analytica chimica acta 195, 247 (1987). http://doi.org/10.1016/S0003-2670(00)85666-4
Abstract: Various bulk and surface analytical techniques were used to study the chemical deterioration of the 13th-to-15th century limestone cathedral in Mechelen, Belgium. The weathering crust on the walls was found to be rich in sulfate, regardless of the geographic orientation. Nitrate and chloride were only detected in minor amounts in the crust and run-off samples. Attack by gaseous sulfur compounds seems to play a dominant role in the stone deterioration mechanism. Electron microprobe analysis showed predominantly bar-shaped gypsum crystals in the crust, and laser microprobe mass spectrometry showed that carbon seems to be responsible for the blackness of most crust samples. Automated electron microprobe analysis also indicated significant differences in the analytical composition of suspensions in run-off water and in rain-water.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)85666-4
|
“Studying aerosol samples by non-linear mapping of electron probe microanalysis data”. Treiger B, van Malderen H, Bondarenko I, van Espen P, Van Grieken R, Analytica chimica acta 284, 119 (1993). http://doi.org/10.1016/0003-2670(93)80014-C
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0003-2670(93)80014-C
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
“Elemental analysis of aerosol-size fractions by proton-induced X-ray-emission”. Johansson TB, Nelson JW, Van Grieken RE, Winchester JW, Transactions of the American Nuclear Society 17, 103 (1973)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
“Composition of aerosols in the surface boundary layer of the atmosphere over the seas of the Western Russian Arctic”. Shevchenko VP, Lisitsin AP, Kuptsov VM, van Malderen H, Martin JM, Van Grieken R, Huang WW, Oceanology 39, 128 (1999)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Parnaiba Basin shales (Northeast Brazil)”. Mabesoone JM, Farias CC, Van Grieken R, Duarte PJ, Delgado A, Freira EMP, Anais da Academia Brasileira de Ciências 57, 481 (1985)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation”. Vincze L, Vekemans B, Szaloki I, Brenker FE, Falkenberg G, Rickers K, Aerts K, Van Grieken R, Adams F, , 220 (2004). http://doi.org/10.1117/12.560416
Abstract: Ibis work illustrates the development of X-ray fluorescence tomography and polycapillary based confocal imaging towards a three-dimensional (313), quantitative analytical method with lateral resolution levels down to the 2-20 mum scale. Detailed analytical characterization is given for polycapillary based confocal XRF imaging, which is a new variant of the 3D micro-XRF technique. Applications for 2D/3D micro-XR-F are illustrated for the analysis of biological (zooplankton) and geological samples (microscopic inclusions in natural diamonds and fluid inclusions in quartz). Based on confocal imaging, fully three-dimensional distributions of trace elements could be obtained, representing a significant generalization of the regular 2D scanning technique for micro-XRF spectroscopy. The experimental work described in this paper has been carried out at the ESRF ID18F microfluorescence end-station and at HASYLAB Beam Line L.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1117/12.560416
|
“Analysis of nonconducting materials by dc glow discharge spectrometry”. Bogaerts A, Schelles W, van Grieken R Wiley, Chichester, page 293 (2003).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Gijbels R, van Grieken R (1977) Application of analytical methods for trace elements in geothermal waters : part 1 : Amélie-les-Bains (Eastern Pyrenees). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Gijbels R, van Grieken R, Blommaert W, Van 't dack L, van Espen P, Nullens H, Saelens R (1983) Application of analytical methods for trace elements in geothermal waters : part 2 : Plombières, Bains-les-Bains, Bourbonne (Vosges). S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Application of trace element analysis to geothermal waters”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 429 (1977)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Colloquium Spectroscopicum Internationale 34: a collection of papers presented at the Colloquium Spectroscopicum Internationale, Antwerp, Belgium, 4-9 September 2005”. Janssens K, Bogaerts A, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Colloquium Spectroscopicum Internationale 34 (CSI 34), Antwerp, Belgium, 4-9 September 2005”. Bogaerts A, Janssens K, van Grieken R Elsevier, Amsterdam (2006).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
van Grieken R, Gijbels R, Speecke A, Hoste J (1971) Determination of oxygen, silicon, phosphorus and copper in iron and steel by 14 MeV neutron activation analysis. S.l
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|