“In-gap band in the one-dimensional two-orbital Kanamori-Hubbard model with interorbital Coulomb interaction”. Aucar Boidi N, Fernández García H, Nunez-Fernandez Y, Hallberg K, Physical review research 3, 043213 (2021). http://doi.org/10.1103/PHYSREVRESEARCH.3.043213
Abstract: We study the electronic spectral properties at zero temperature of the one-dimensional (1D) version of the degenerate two-orbital Kanamori-Hubbard model, one of the well-established frameworks to study transition metal compounds, using state-of-the-art numerical techniques based on the density matrix renormalization group. While the system is Mott insulating for the half-filled case, as expected for an interacting 1D system, we find interesting and rich structures in the single-particle density of states (DOS) for the hole-doped system. In particular, we find the existence of in-gap states which are pulled down to lower energies from the upper Hubbard band with increasing the interorbital Coulomb interaction V. We analyze the composition of the DOS by projecting it onto different local excitations, and we observe that for large dopings these in-gap excitations are formed mainly by interorbital holon-doublon (HD) states and their energies follow approximately the HD states in the atomic limit. We observe that the Hund interaction J increases the width of the in-gap band, as expected from the two-particle fluctuations in the Hamiltonian. The observation of a finite density of states within the gap between the Hubbard bands for this extended 1D model indicates that these systems present a rich excitation spectra which could help us understand the microscopic physics behind multiorbital compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS)
DOI: 10.1103/PHYSREVRESEARCH.3.043213
|
“Individual particle analysis by automated EPMA for the improvement of source apportionment for remote aerosols”. Storms H, Artaxo P, Bruynseels F, Van Grieken R page 343 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Individual particle analysis of sediments from the Gulf of Lions, suspensions from the Rhône river and dust of Saharan origin: preliminary results”. Wegrzynek D, Eisma D, Van Grieken R, (1992)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK”. Brimblecombe P, Blades N, Camuffo D, Sturaro G, Valentino A, Gysels K, Van Grieken R, Busse H-J, Kim O, Ulrych U, Wieser M, Indoor air 9, 146 (1999). http://doi.org/10.1111/J.1600-0668.1999.T01-1-00002.X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0668.1999.T01-1-00002.X
|
“Influence of gaseous and particulate air pollutants on stained glass windows: case study in the Basilica Saint Urbain in Troyes, France”. Kontozova V, Godoi RHM, Spolnik Z, Worobiec A, Deutsch F, Van Grieken R, (2005)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
Anaf W (2014) The influence of particulate matter on cultural heritage : chemical characterisation of the interaction between the atmospheric environment and pigments. 319 p
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Inorganic compounds of atmospheric aerosols”. Claes M, Gysels K, Van Grieken R, Harrison RM page 95 (1998).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Integrated analytical techniques for analysing individual environmental particles”. Potgieter-Vermaak S, Van Grieken R, Potgieter JH page 123 (2012).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Integration of analysis techniques of different scales using X ray induced and electron induced X ray spectrometry for applications in preventive conservation and environmental monitoring”. Van Grieken R, Darchuk L, Kontozova V, Potgieter-Vermaak S, van Meel K, Stefaniak E, Worobiec A page 53 (2011).
Abstract: In the past years, and also within the framework of this CRP, we have used a combination of several nuclear and non-nuclear techniques in fundamental research and especially in various applications. Most work has been done with energy-dispersive X ray fluorescence in combination with electron probe X ray microanalysis, but several other more common analysis techniques have been used as well. The applications have included mostly preventive conservation (e.g. characterisation of damaging atmospheric particles in many museums) and environmental monitoring (e.g. for atmospheric particles in relation to their health effects in outdoor and especially indoor environments). Fundamental aspects have been in the optimising of interfaced electron microprobe and Raman microprobe analysis and the evaluation of the potential of such an instrument for atmospheric aerosols; quite a few unexpected and unpredicted problems have appeared in the latter study.
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Interpretation of aerosol trace metal particle size distributions”. Johansson TB, Van Grieken RE, Winchester JW page 356 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Introduction: considering the role of X-ray spectrometry in chemical analysis and outlining the volume”. Van Grieken R page 1 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Investigation of individual particles and gaseous air pollutants in showcases”. Godoi RHM, Kontozova V, Godoi AFL, Van Grieken R page 147 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
van der Snickt G (2012) James Ensor's pigments studied by means of portable and synchrotron radiation-based X-ray techniques : evolution, context and degradation. 501 p
Keywords: Doctoral thesis; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“LAMMA analysis of inorganic ammonium compounds in individual marine aerosol particles”. Otten P, Bruynseels, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“LAMMA : calibration and application to nephrotoxicology studies”. Verbueken A, Paulus G, Van de Vyver F, Verpooten G, de Broe M, Van Grieken R, (1983)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“LAMMA in nephrotoxicity studies”. Verbueken AH, Paulus GJ, Van de Vyver FL, Verpooten GA, Visser WJ, de Broe ME, Van Grieken RE, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“LAMMA-study of aerosol samples collected in the Amazon basin”. Bruynseels F, Artaxo P, Storms H, Van Grieken R page 355 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Hellemans K (2019) Laser ablation ICP-MS as a tool for surface analysis in comparison to other elemental analysis methods. 229 p
Abstract: Dit onderzoek presenteert een overzicht van de mogelijkheden van LA-ICP-MS als een techniek voor kwantitatieve analyse, bepalen van isotoopverhoudingen en elementaire beeldvorming. Hiervoor wordt de techniek zelf voorgesteld en worden de belangrijkste parameters die een invloed hebben op de kwaliteit van een LA-ICP-MS meting beschreven. Voor kwantitieve analyse worden de huidige calibratiestrategieën voor LA-ICP-MS toegelicht, zowel op het vlak van selectie en bereiding van standaarden als op het vlak van dataverwerking. Daarnaast werd een nieuwe calibratiestrategie voorgesteld, gebaseerd op een lineaire combinatie van standaarden. Een case study met de traditionele calibratiestrategie uit de literatuur werd uitgevoerd en vergeleken met data van SEM-EDX om een referentiekader te schetsen voor de performantie van de techniek. In een tweede case study werd onze nieuwe calibratiestrategie toegepast en werd er uitsluitend gebruik gemaakt van LA-ICP-MS, wat uitstekende resultaten opleverde. Met het oog op het bepalen van isotoopverhoudingen, werd er onderzocht wat de limieten zijn van het gebruik van een lage resolutie quadrupool massaspectrometer voor deze bepaling. Dit stelde ons in staat om de te verwachten accuraatheid en precisie in te schatten. De performantie bleek goed genoeg te zijn om weapon-grade plutonium te onderscheiden van global fall-out, zoals het werd aangetoond in de case study omtrent dit onderwerp. Uiteindelijk hebben we ook LA-ICP-MS geëvalueerd als een techniek voor elementaire beeldvorming, waarbij we tevens de meest courante multivariate data analyse hebben beschreven. Om de techniek te plaatsen tegenover andere elementaire technieken, werd een historisch verffragment geanalyseerd dat in het verleden reeds geanalyseerd was met SEM-EDX and μ-XRD. Op die manier konden we de resultaten accuraat vergelijken met de andere technieken.
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass analysis : characteristics and applications”. Van Grieken R, Verbueken A, Bruynseels F, Vandeputte D, Goossenaerts C, Leysen L, Otten P, Wouters L, (1987)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Laser microprobe mass analysis (LAMMA) in nephrological investigations”. Verbueken AH, Van de Vyver FL, Paulus GJ, Visser WJ, Verpooten GA, de Broe ME, Van Grieken RE page 375 (1984).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Laser microprobe mass analysis (LAMMA) of parathyroid glands from dialysis patients”. Verbueken AH, Van de Vyver FL, Nouwen EJ, Roels F, de Broe ME, Van Grieken RE page 443 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Localisation of lead and fluoride in cultured tooth germs by laser microprobe mass analysis (LAMMA)”. Vandeputte D, Ameloot P, Van Grieken R page 90 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Localisation of lead in tissues of poisoned rats by laser microprobe mass analysis (LAMMA)”. Vandeputte D, Verbueken A, Jacob W, de Broe M, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples”. Ravindra K, Godoi AFL, Bencs L, Van Grieken R, Journal of chromatography: A: bibliography section 1114, 278 (2006). http://doi.org/10.1016/J.CHROMA.2006.03.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2006.03.025
|
“Luchtkwaliteit boven de Noordzeekust”. Eyckmans K, Van Grieken R page 9 (2001).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Manufacturing techniques and production defects of 16th-17th century majolica tiles from Antwerp (Belgium)”. Vandevijvere M, Van de Voorde L, Caen J, van Espen P, Vekemans B, Vincze L, Schalm O page 169 (2013).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
|
“Mapping of toxic vapours on board of tankers”. Jacobs W, Floren E, Luyckx D, Bueken P, van Beeck J, Van Grieken R, (2011)
Keywords: P3 Proceeding; Economics; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Martime influences on the atmospheric aerosol composition”. Van Grieken R page 139 (1977).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Material analysis methods applied to the study of ancient monuments, works of art and artefacts”. Delalieux F, Tsuji K, Wagatsuma K, Van Grieken R, Materials transactions 43, 2197 (2002). http://doi.org/10.2320/MATERTRANS.43.2197
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.2320/MATERTRANS.43.2197
|
Saison J-Y, Roekens E, Matheeussen C, Verlinden L, Desmedt M, Van Grieken R, Stranger M (2005) Measurement campaigns in the Euro-region
Keywords: Minutes and reports; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|