|
“A flexible and accurate quantification algorithm for EPXMA based on thin-film element yields”. Schalm O, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 58, 669 (2003). http://doi.org/10.1016/S0584-8547(02)00290-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(02)00290-2
|
|
|
“A general Monte-Carlo simulation of energy-dispersive X-ray fluorescence spectrometers : 1 : unpolarized radiation, homogenious samples”. Vincze L, Janssens K, Adams F, Spectrochimica acta: part B : atomic spectroscopy 48, 553 (1993). http://doi.org/10.1016/0584-8547(93)80060-8
Abstract: A general Monte Carlo program for the simulation of X-ray fluorescence (XRF) spectrometers is presented. The global layout of the program is discussed and the way in which variance reduction techniques have been employed to improve the efficiency of the code is described. For the case of polychromatic excitation in a direct excitation energy-dispersive (ED) XRF instrument, experimentally collected ED-XRF spectra are compared with simulated spectral distributions. Applications of the software in the field of quantitative analysis and thickness estimation of samples of intermediate thickness illustrate the potential of the method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(93)80060-8
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 1: theory”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 75 (2000). http://doi.org/10.1016/S0584-8547(99)00172-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00172-X
|
|
|
“Interpretation and use of inter-element correlation graphs obtained by scanning X-ray fluorescence micro-beam spectrometry from individual particles: part 2: application”. Somogyi A, Janssens K, Vincze L, Vekemans B, Rindby A, Adams F, Spectrochimica acta: part B : atomic spectroscopy 55, 1039 (2000). http://doi.org/10.1016/S0584-8547(00)00220-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00220-2
|
|
|
“Localised and non-destructive analysis of metallic artefacts from ancient Egypt by means of a compact μ-XRF instrument”. Vittiglio G, Janssens K, Adams F, Oost A, Spectrochimica acta: part B : atomic spectroscopy 54, 1697 (1999). http://doi.org/10.1016/S0584-8547(99)00100-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00100-7
|
|
|
“A micro XRF spectrometer based on rotating anode generator and capillary optics”. Janssens K, Vekemans B, Vincze L, Adams F, Rindby A, Spectrochimica acta: part B : atomic spectroscopy 51, 1661 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Monte Carlo simulation of X-ray fluorescence spectra: part 4: photon scattering at high X-ray energies”. Vincze L, Janssens K, Vekemans B, Adams F, Spectrochimica acta: part B : atomic spectroscopy , 1711 (1999). http://doi.org/10.1016/S0584-8547(99)00094-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(99)00094-4
|
|
|
“mu-X-ray fluorescence and mu-X-ray diffraction investigations of sediment from the Ruprechtov nuclear waste disposal natural analog site”. Denecke MA, de Nolf W, Janssens K, Brendebach B, Falkenberg G, Noseck U, Rothkirch A, Spectrochimica acta: part B : atomic spectroscopy 63, 484 (2008). http://doi.org/10.1016/J.SAB.2008.01.001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2008.01.001
|
|
|
“Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies”. de Nolf W, Jaroszewicz J, Terzano R, Lind OC, Salbu B, Vekemans B, Janssens K, Falkenberg G, Spectrochimica acta: part B : atomic spectroscopy 64, 775 (2009). http://doi.org/10.1016/J.SAB.2009.06.003
Abstract: The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.30.5° are obtained at the bending magnet source when a pink beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.10.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 7
DOI: 10.1016/J.SAB.2009.06.003
|
|
|
“Spatially resolved micro-X-ray fluorescence and micro-X-ray absorption fine structure study of a fractured granite bore core following a radiotracer experiment”. Denecke MA, Brendebach B, de Nolf W, Falkenberg G, Janssens K, Simon R, Spectrochimica acta: part B : atomic spectroscopy 64, 791 (2009). http://doi.org/10.1016/J.SAB.2009.05.025
Abstract: Spatially resolved X-ray absorption and fluorescence investigation with a micrometer-scale resolution on actinide-containing samples provide information necessary for safety assessment of nuclear waste disposal. In this paper one example of such an experiment is presented. This example entails neptunium speciation in a fractured granite bore core from the Swedish Äspö Hard Rock Laboratory following a radiotracer experiment using µ-XAFS and µ-XRF. In order to probe micro-volumes below the surface in the granite samples and thereby avoid potential changes in the Np speciation during cutting of the bore core, a confocal irradiationdetection geometry is employed. µ-XAFS results for a selected granite bore core cross section with ~ 3 nmol Np/g reveal that Np, originally introduced as Np(V) in the tracer cocktail, is present in the granite in its reduced Np(IV) form. The Np(IV) is often present as particles, tens of µm in size. Elemental distribution maps show the tracer Np to be located in fissures and permeable channels not larger than 100 µm. The Np distribution appears often correlated with Zn also present in some fissures. We observe small granite fissures containing Fe (presumably Fe(II)), where we do not detect any Np. It is feasible that inflowing Np(V) has a shorter residence time in large fractures, while in the smaller fissures migration is slower, leading to longer residence times, i.e., reaction times, where it is reduced to less soluble Np(IV) and becomes thereby immobilized.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
Times cited: 21
DOI: 10.1016/J.SAB.2009.05.025
|
|
|
“The use of synchrotron micro-XRF for characterisation of the micro-heterogeneity of low-Z reference materials”. Kempenaers L, Vincze L, Janssens K, Spectrochimica acta: part B : atomic spectroscopy 55, 651 (2000). http://doi.org/10.1016/S0584-8547(00)00207-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.241
DOI: 10.1016/S0584-8547(00)00207-X
|
|
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
|
|
“Application of combined micro-proton-induced X-ray emission and micro-synchrotron radiation X-ray fluorescence techniques for the characterization of impact materials around Barringer Meteor Crater”. Uzonyi I, Szöör G, Vekemans B, Vincze L, Rozsa P, Szabo G, Somogyi A, Adams F, Kiss ÁZ, Spectrochimica acta: part B : atomic spectroscopy 59, 1717 (2004). http://doi.org/10.1016/J.SAB.2004.05.030
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2004.05.030
|
|
|
“Application of energy dispersive X-ray spectrometry for quantitative evaluation of sorption phenomena at solid-liquid interfaces”. Szalóki I, Varga K, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 55, 1031 (2000). http://doi.org/10.1016/S0584-8547(00)00175-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00175-0
|
|
|
“Comparison of grazing-exit particle-induced X-ray emission with other related methods”. Tsuji K, Huisman M, Spolnik Z, Wagatsuma K, Mori Y, Van Grieken RE, Vis RD, Spectrochimica acta: part B : atomic spectroscopy 55, 1009 (2000). http://doi.org/10.1016/S0584-8547(00)00148-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(00)00148-8
|
|
|
“Comparison of sediment pollution in the rivers of the Hungarian Upper Tisza Region using non-destructive analytical techniques”. Osán J, Török S, Alföldy B, Alsecz A, Falkenberg G, Baik SY, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 62, 123 (2007). http://doi.org/10.1016/J.SAB.2007.02.005
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2007.02.005
|
|
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|
|
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
|
|
“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
|
|
“Enhancement of X-ray fluorescence intensity from an ultra-thin sandwiched layer at grazing-emission angles”. Tsuji K, Takenaka H, Wagatsuma K, de Bokx PK, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1881 (1999). http://doi.org/10.1016/S0584-8547(99)00143-3
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00143-3
|
|
|
“Grazing-emission electron probe microanalysis of particles near the substrate edge”. Bekshaev A, de Hoog J, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 56, 2385 (2001). http://doi.org/10.1016/S0584-8547(01)00300-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00300-7
|
|
|
“IDAS: a Windows based software package for cluster analysis”. Bondarenko I, Treiger B, Van Grieken R, van Espen P, Spectrochimica acta: part B : atomic spectroscopy 51, 441 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Interference technique in grazing-emission electron probe microanalysis of submicrometer particles”. Bekshaev A, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 56, 503 (2001). http://doi.org/10.1016/S0584-8547(01)00177-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00177-X
|
|
|
“Investigation of the chemical composition of (Na1-xBix)(MnyNb1-y)O3 ceramics by single particle electron probe X-ray microanalysis with an application of Monte Carlo simulations”. Spolnik Z, Osán J, Klepka M, Lawniczak-Jablonska K, Van Grieken R, Molak A, Potgieter JH, Spectrochimica acta: part B : atomic spectroscopy 60, 525 (2005). http://doi.org/10.1016/J.SAB.2005.03.013
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2005.03.013
|
|
|
“Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters”. Bencs L, Ravindra K, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 58, 1723 (2003). http://doi.org/10.1016/S0584-8547(03)00162-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(03)00162-9
|
|
|
“Mobile depth profiling and sub-surface imaging techniques for historical paintings : a review”. Alfeld M, Broekaert JAC, Spectrochimica acta: part B : atomic spectroscopy 88, 211 (2013). http://doi.org/10.1016/J.SAB.2013.07.009
Abstract: Hidden, sub-surface paint layers and features contain valuable information for the art-historical investigation of a painting's past and for its conservation for coming generations. The number of techniques available for the study of these features has been considerably extended in the last decades and established techniques have been refined. This review focuses on mobile non-destructive subsurface imaging and depth profiling techniques, which allow for the in-situ investigation of easel paintings, i.e. paintings on a portable support. Among the techniques discussed are: X-ray radiography and infrared reflectography, which are long established methods and are in use for several decades. Their capabilities of element/species specific imaging have been extended by the introduction of energy/wavelength resolved measurements. Scanning macro-X-ray fluorescence analysis made it for the first time possible to acquire elemental distribution images in-situ and optical coherence tomography allows for the non-destructive study the surface paint layers in virtual cross-sections. These techniques and their variants are presented next to other techniques, such as Terahertz imaging, Nuclear Magnetic Resonance depth profiling and established techniques for non destructive testing (thermography, ultrasonic imaging and laser based interference methods) applied in the conservation of historical paintings. Next to selected case studies the capabilities and limitations of the techniques are discussed. (C) 2013 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2013.07.009
|
|
|
“Molecular and elemental characterisation of mineral particles by means of parallel micro-Raman spectrometry and Scanning Electron Microscopy/Energy Dispersive X-ray Analysis”. Stefaniak EA, Worobiec A, Potgieter-Vermaak S, Alsecz A, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 61, 824 (2006). http://doi.org/10.1016/J.SAB.2006.04.009
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2006.04.009
|
|
|
“Molecular ion distributions in laser microprobe mass-spectrometry of calcium-oxide and calcium salts”. Bruynseels FJ, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 38, 853 (1983). http://doi.org/10.1016/0584-8547(83)80184-0
Abstract: Laser Microprobe Mass Spectrometry (LAMMA) is used to examine micrometric particles of calcium oxyanion salts (CaCO3, CaSO4, CaSO4·2H2O) and calcium oxide, in both the positive and negative ion mode. The major molecular ions, appearing in the positive mass spectrum, can be divided into three series, namely CamOm-1+, (CaO)m+ and (CaO)mH+ (m = 1-4). In the case of the former two series the relative intensities of the mass peaks as a function of the fragment valence K = (1 + 2n)/m, for CamOn+, can be fitted to a Gaussian distribution curve, as was earlier demonstrated for secondary ion mass spectrometry. The high stability of the (CaO)mH+ series can be explained by the favourable fragment valence of +2 corresponding to the usual oxidation state of calcium.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0584-8547(83)80184-0
|
|
|
“Non-linear mapping of microbeam proton-induced X-ray emission data for source identification of North Sea aerosols”. Treiger B, Injuk J, Bondarenko I, van Espen P, Van Grieken R, Breitenbach L, Wätjen U, Spectrochimica acta: part B : atomic spectroscopy 49, 345 (1994). http://doi.org/10.1016/0584-8547(94)80029-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0584-8547(94)80029-4
|
|
|
“Optimization of sample preparation for grazing emission X-ray fluorescence in micro- and trace analysis applications”. Claes M, de Bokx P, Willard N, Veny P, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 52, 1063 (1997). http://doi.org/10.1016/S0584-8547(96)01654-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(96)01654-0
|
|