“Laser ionization mass-spectrometry for the characterization of solid materials”. van Vaeck L, Vanroy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 20, S29 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Chemical analysis in metal processing: overview and future needs in refined and ultrapure metals”. Gijbels R, Acta technica Belgica: metallurgie 30, 91 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Comportement hydrogéochimique des éléments traces au cours de l'interaction eau –, roche en milieu alcalin”. Pentcheva EN, Petrov PS, Veldeman E, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 43, 51 (1990)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Études génétiques du système “eau thermale –, gaz –, roche&rdquo, sous l'influence de phénomènes volcaniques récents”. Pentcheva EN, Petrov PS, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 48, 99 (1995)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Recherches microchimiques comparatives (SME et AAN) d'hydrothermes des granites de la Bulgarie du Sud”. Pentcheva EN, Swenters K, Van 't dack L, Verlinden J, Gijbels R, Doklady Bolgarskoi Akademii Nauk 37, 509 (1984)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Sur l'équilibre hydrogéochimique “solution –, suspension&rdquo, dans les systèmes hydrothermaux du socle cristallin”. Pentcheva EN, Veldeman E, Van 't dack L, Gijbels R, Doklady Bolgarskoi Akademii Nauk 49, 65 (1996)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Sample erosion studies in a glow discharge ionization cell”. van Straaten M, Vertes A, Gijbels R, Spectrochimica acta 46b, 283 (1991)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Trace-elemental anomalies in surface water near a small lead-zinc mineralization at Menez-Albot (Brittany, France)”. Vandelannoote R, Blommaert W, Sadurski A, Van 'T Dack L, Gijbels R, Van Grieken R, Bosch B, Leleu M, Rochon J, Sarcia C, Sureau JF;, Journal of geochemical exploration 20, 33 (1984). http://doi.org/10.1016/0375-6742(84)90088-8
Abstract: Sensitive multi-element analysis techniques were applied to water samples collected in the vicinity of a small Zn-Pb-Cu sulfide mineralization in the region of Menez-Albot (Finistère, France). The variation of the trace-element content along a local stream shows the presence of the mineralization, mainly through a simultaneous positive anomaly in solution for a group of about 10 elements (e.g. Ni, Cu, Zn, As, Sb) which are connected with this type of mineralization. The anomaly decreases steeply due to the influx of swamp water rich in Fe, Mn and organic matter. The precipitation barrier is reflected in the stream sediment composition. Contamination from fertilizers was observed in some samples.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.747
Times cited: 4
DOI: 10.1016/0375-6742(84)90088-8
|
“Trace-element geochemistry of thermal water percolating through a karstic environment in the region of Saint Ghislain (Belgium)”. Blommaert W, Vandelannoote R, Sadurski A, Van 't dack L, Gijbels R, Journal of volcanology and geothermal research 19, 331 (1983). http://doi.org/10.1016/0377-0273(83)90117-8
Abstract: Five geothermal waters from the Mons area (southern Belgium) have been studied: one natural hot spring at Stambruges, one stagnant warm water from the inclined tunnels at Baudour, and three thermal waters from the drillholes at St. Ghislain, Ghlin and Douvrain, originating from the carbonate/anhydrite-bearing Visean strata, at depths of ca. 2600, 1550 and 1300 m, respectively. Multielement chemical analysis of the filtered water and its suspended matter > 0.4 μm) was carried out by instrumental neutron activation. Temperature in depth, calculated using the silica (chalcedony) chemical geothermometer, ranged from 75 to 88°C, in good agreement with experimentally determined values. Na/K and Na/K/Ca geothermometers yieilded erratic results, as expected from the geological environment in the aquifer. From the analytical data it can be calculated that the thermal waters of St. Ghislain, Ghlin and Douvrain are not only saturated with respect to chalcedony, but also to anhydrite, calcite, fluorite, barite, strontianite, and possibly zinc silicate, iron (III) hydroxide or siderite, albite, microcline, gibbsite and kaolinite. They are oversaturated with respect to muscovite. Data are also presented for the other thermal waters, and a cold spring water (Claire Fontaine, Stambruges). The similar trace-element composition of the thermal waters can be explained by percolation of the water in the same distant recharge zone, from where it descends, becomes heated at depth and rises along collapse breccia, and locally (Baudour, Stambruges) along fissures. The uptake of higher amounts of Ca, Mg, Sr and sulfate in St. Ghislain and Ghlin, as compared to Douvrain and Baudour is correlated with the boundary between the non-dissolved and dissolved evaporitic zones. This boundary is situated between St. Ghislain and Douvrain, and is roughly parallel with the direction of the groundwater flow (WNW).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.543
Times cited: 2
DOI: 10.1016/0377-0273(83)90117-8
|
“Trace element and micro-mineral composition of some selected anhydrite samples from the Saint Ghislain drill hole (Hainaut, Belgium)”. Vandelannoote R, Van 't dack L, Gijbels R, Bulletin van de Belgische Vereniging voor Geologie 95, 101 (1986)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Conductivity and electron density of undoped model compounds of poly(phenylene vinylene)”. Yang Z, Geise HJ, Mehbod M, Debrue G, Visser JW, Sonneveld EJ, Van 't dack L, Gijbels R, Synthetic metals 39, 137 (1990). http://doi.org/10.1016/0379-6779(90)90179-O
Abstract: Fourteen derivatives of trans,trans-1,4-bis[2-phenylethenyl]benzene were synthesized by Wittig reactions as model compounds of poly(paraphenylene vinylene). Structure, configurational homogeneity and absence of ionic impurities were controlled by mass spectrometry, infrared and neutron activation analysis, respectively. Crystallographic unit cell parameters were obtained from X-ray powder patterns and measurements of electrical conductivities were performed on undoped samples. The data of four more compounds containing one or more thiophene rings instead of phenyl rings were added from the 3iterature. If NO2 and Cl groups are excluded from the electron count a good linear correlation is found between the logarithm of the conductivity and the non-σ electron density (View the MathML source). The position of the substituents, on the central or on the terminal ring, also plays a role in as much as it affects the molecular volume of the compound but not the non-σ electron density. The correlation between the logarithm of the conductivity and the absorption coefficient of the longest wavelength of UV absorption identifies the π electrons in the chromophore as the principal charge carriers.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.252
Times cited: 25
DOI: 10.1016/0379-6779(90)90179-O
|
“Modelleren van plasmas gebruikt voor de afzetting van dunne lagen”. Herrebout D, Bogaerts A, Gijbels R, Chemie magazine , 34 (2004)
Keywords: A2 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Organische TOF-S-SIMS: gebruik van opgedampt Ag en Au voor de verhoging van secundaire ionenintensiteiten”. Adriaensen L, Vangaever F, Gijbels R, Chemie magazine , 10 (2004)
Keywords: A2 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“L'analyse des eaux géothermales par spectrométrie de masse à, étincelles”. Vandelannoote R, Blommaert W, van Grieken R, Gijbels R, Spectra 2000: la revue de l'instrumentation 53, 66 (1979)
Keywords: A3 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Mass spectrometric analysis of inorganic solids: GDMS and other methods”. Gijbels R, van Straaten M, Bogaerts A, Advances in mass spectrometry 13, 241 (1995)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 12
|
“Behavior of the sputtered copper atoms, ions and excited species in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 279 (2000). http://doi.org/10.1016/S0584-8547(00)00142-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 17
DOI: 10.1016/S0584-8547(00)00142-7
|
“Calculation of rate constants for asymmetric charge transfer, and their effect on relative sensitivity factors in glow discharge mass spectrometry”. Bogaerts A, Temelkov KA, Vuchkov NK, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 62, 325 (2007). http://doi.org/10.1016/j.sab.2007.03.010
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 28
DOI: 10.1016/j.sab.2007.03.010
|
“Collisional-radiative model for the sputtered copper atoms and ions in a direct current argon glow discharge”. Bogaerts A, Gijbels R, Carman RJ, Spectrochimica acta: part B : atomic spectroscopy 53, 1679 (1998). http://doi.org/10.1016/S0584-8547(98)00201-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 71
DOI: 10.1016/S0584-8547(98)00201-8
|
“Comparison between a radio-frequency and direct current glow discharge in argon by a hybrid Monte Carlo-fluid model for electrons, argon ions and fast argon atoms”. Bogaerts A, Gijbels R, Goedheer W, Spectrochimica acta: part B : atomic spectroscopy 54, 1335 (1999). http://doi.org/10.1016/S0584-8547(99)00080-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 11
DOI: 10.1016/S0584-8547(99)00080-4
|
“Comparison of modeling calculations with experimental results for direct current glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 56, 551 (2001). http://doi.org/10.1016/S0584-8547(01)00220-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 16
DOI: 10.1016/S0584-8547(01)00220-8
|
“Comparison of modeling calculations with experimental results for rf glow discharge optical emission spectrometry”. Bogaerts A, Wilken L, Hoffmann V, Gijbels R, Wetzig K, Spectrochimica acta: part B : atomic spectroscopy 57, 109 (2002). http://doi.org/10.1016/S0584-8547(01)00357-3
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 14
DOI: 10.1016/S0584-8547(01)00357-3
|
“Comprehensive description of a Grimm-type glow discharge source used for optical emission spectrometry: a mathematical simulation”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 437 (1998). http://doi.org/10.1016/S0584-8547(97)00148-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 46
DOI: 10.1016/S0584-8547(97)00148-1
|
“Description of the argon-excited levels in a radio-frequency and direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 55, 263 (2000). http://doi.org/10.1016/S0584-8547(00)00143-9
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 24
DOI: 10.1016/S0584-8547(00)00143-9
|
“Experimental determination of the energy distribution of ions bombarding the cathode surface in a glow discharge”. van Straaten M, Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 50, 583 (1995). http://doi.org/10.1016/0584-8547(94)00158-R
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.176
Times cited: 22
DOI: 10.1016/0584-8547(94)00158-R
|
“Fundamental aspects and applications of glow discharge spectrometric techniques”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 53, 1 (1998). http://doi.org/10.1016/S0584-8547(97)00122-5
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 49
DOI: 10.1016/S0584-8547(97)00122-5
|
“Fundamental studies on a planar-cathode direct current glow discharge: part 2: numerical modeling and comparison with laser scattering experiments”. Bogaerts A, Gijbels R, Gamez G, Hieftje GM, Spectrochimica acta: part B : atomic spectroscopy 59, 449 (2004). http://doi.org/10.1016/j.sab.2003.12.001
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 26
DOI: 10.1016/j.sab.2003.12.001
|
“Gas discharge plasmas and their applications”. Bogaerts A, Neyts E, Gijbels R, van der Mullen J, Spectrochimica acta: part B : atomic spectroscopy 57, 609 (2002). http://doi.org/10.1016/S0584-8547(01)00406-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 462
DOI: 10.1016/S0584-8547(01)00406-2
|
“Hybrid model for a cylindrical hollow cathode glow discharge and comparison with experiments”. Baguer N, Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 57, 311 (2002). http://doi.org/10.1016/S0584-8547(01)00385-8
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 31
DOI: 10.1016/S0584-8547(01)00385-8
|
“Hybrid Monte-Carlo-fluid modeling network for an argon/hydrogen direct current glow discharge”. Bogaerts A, Gijbels R, Spectrochimica acta: part B : atomic spectroscopy 57, 1071 (2002). http://doi.org/10.1016/S0584-8547(02)00047-2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 68
DOI: 10.1016/S0584-8547(02)00047-2
|
“Laser ablation for analytical sampling: what can we learn from modeling?”.Bogaerts A, Chen Z, Gijbels R, Vertes A, Spectrochimica acta: part B : atomic spectroscopy 58, 1867 (2003). http://doi.org/10.1016/j.sab.2003.08.004
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.241
Times cited: 321
DOI: 10.1016/j.sab.2003.08.004
|