|
“High-resolution mass spectrometry and nontraditional mass defect analysis of brominated historical pigments”. Alvarez-Martin A, Newsome GA, Janssens K, Analytical Chemistry 93, 14851 (2021). http://doi.org/10.1021/ACS.ANALCHEM.1C03815
Abstract: The implementation of high-resolution mass spectrometry systems offers new possibilities for the analysis of complex art samples such as historical oil paintings. However, these multicomponent systems generate large and complex data sets that require advanced visualization tools to aid interpretation, especially when no chromatographic separation is performed. In the context of this research, it was crucial to propose a data analysis tool to identify the products generated during the synthesis, drying, and aging of historical pigments. This study reports for the first time a nontraditional mass defect analysis of oil paint samples containing a fugitive brominated-organic pigment, eosin or geranium lake, by using direct infusion electrospray ionization in combination with a high-resolution Orbitrap mass spectrometer. The use of nontraditional Kendrick mass defect plots is presented in this study as a processing and visualization tool to recognize brominated species based on their specific mass defect and isotope pattern. The results demonstrate that this approach could provide valuable molecular compositional information on the degradation pathways of this pigment. We anticipate that mass defect analysis will become highly relevant in future degradation studies of many more historical organic pigments.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp X-ray Imaging and Spectroscopy (AXIS)
Impact Factor: 6.32
DOI: 10.1021/ACS.ANALCHEM.1C03815
|
|
|
“Interface for reproducible, multishot direct analysis of solid-phase microextraction samples”. Newsome GA, Kavich G, Alvarez-Martin A, Analytical Chemistry 92, 4182 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05691
Abstract: An enclosed interface that joins a direct analysis in real time (DART) probe, solid-phase microextraction (SPME) fiber, and the inlet of a high-resolution mass spectrometer is described. Unlike other systems to couple SPME sampling to ambient mass spectrometry, the interface is able to perform discrete analyses on different areas of a single SPME fiber device for up to three technical replicate measurements of one sampling event. Inlet flow speed and desorption temperature are optimized, and reproducibility is demonstrated between replicate analyses on the same derivatized SPME fiber and with sequential fiber sampling events, yielding analyte measurement center of variance (CV) from 3 to 6%. Conditioning is also performed with the enclosed DART. The interface is a straightforward addition to commercially available technologies, and machine diagrams for custom components operated with SPME/DART/MS equipment are included.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05691
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
|
|
“A Monte Carlo program for quantitative electron-induced x-ray analysis of individual particles”. Ro C-U, Osán J, Szalóki I, de Hoog J, Worobiec A, Van Grieken R, Analytical chemistry 75, 851 (2003). http://doi.org/10.1021/AC025973R
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC025973R
|
|
|
“Nanobody-based immunosensor detection enhanced by photocatalytic-electrochemical redox cycling”. Trashin S, Morales-Yánez F, Thiruvottriyur Shanmugam S, Paredis L, Carrión EN, Sariego I, Muyldermans S, Polman K, Gorun SM, De Wael K, Analytical Chemistry 93, 13606 (2021). http://doi.org/10.1021/ACS.ANALCHEM.1C02876
Abstract: Detection of antigenic biomarkers present in trace amounts is of crucial importance for medical diagnosis. A parasitic disease, human toxocariasis, lacks an adequate diagnostic method despite its worldwide occurrence. The currently used serology tests may stay positive even years after a possibly unnoticed infection, whereas the direct detection of a re-infection or a still active infection remains a diagnostic challenge due to the low concentration of circulating parasitic antigens. We report a time-efficient sandwich immunosensor using small recombinant single-domain antibodies (nanobodies) derived from camelid heavy-chain antibodies specific to Toxocara canis antigens. An enhanced sensitivity to pg/mL levels is achieved by using a redox cycle consisting of a photocatalytic oxidation and electrochemical reduction steps. The photocatalytic oxidation is achieved by a photosensitizer generating singlet oxygen (1O2) that, in turn, readily reacts with p-nitrophenol enzymatically produced under alkaline conditions. The photooxidation produces benzoquinone that is electrochemically reduced to hydroquinone, generating an amperometric response. The light-driven process could be easily separated from the background, thus making amperometric detection more reliable. The proposed method for detection of the toxocariasis antigen marker shows superior performances compared to other detection schemes with the same nanobodies and outperforms by at least two orders of magnitude the assays based on regular antibodies, thus suggesting new opportunities for electrochemical immunoassays of challenging low levels of antigens.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 6.32
DOI: 10.1021/ACS.ANALCHEM.1C02876
|
|
|
“Parameter evaluation for the analysis of oxide-based samples with radio ferquency glow discharge mass spectrometry”. de Gendt S, Van Grieken RE, Ohorodnik SK, Harrison WW, Analytical chemistry 67, 1026 (1995). http://doi.org/10.1021/AC00102A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00102A002
|
|
|
“Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy: energy-dispersive X-ray spectrometry”. Choël M, Deboudt K, Osán J, Flament P, Van Grieken R, Analytical chemistry 77, 5686 (2005). http://doi.org/10.1021/AC050739X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC050739X
|
|
|
“Sub-part-per-billion determination of total dissolved selenium and selenite in environmental waters by X-ray fluorescence spectrometry”. Robberecht HJ, Van Grieken RE, Analytical chemistry 52, 449 (1980). http://doi.org/10.1021/AC50053A017
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50053A017
|
|
|
“Thin-layer potentiometry for creatinine detection in undiluted human urine using ion-exchange membranes as barriers for charged interferences”. Liu Y, Cánovas R, Crespo GA, Cuartero M, Analytical Chemistry 92, 3315 (2020). http://doi.org/10.1021/ACS.ANALCHEM.9B05231
Abstract: Herein, thin-layer potentiometry combined with ion-exchange membranes as barriers for charged interferences is demonstrated for the analytical detection of creatinine (CRE) in undiluted human urine. Briefly, CRE diffuses through an anion-exchange membrane (AEM) from a sample contained in one fluidic compartment to a second reservoir, containing the enzyme CRE deiminase. There, CRE reacts with the enzyme, and the formation of ammonium is dynamically monitored by potentiometric ammonium-selective electrodes. This analytical concept is integrated into a lab-on-a-chip microfluidic cell that allows for a high sample throughput and the operation under stop-flow mode, which allows CRE to passively diffuse across the AEM. Conveniently, positively charged species (i.e., potassium, sodium, and ammonium, among others) are repelled by the AEM and never reach the ammonium-selective electrodes; thus, possible interference in the response can be avoided. As a result, the dynamic potential response of the electrodes is entirely ascribed to the stoichiometric formation of ammonium. The new CRE biosensor exhibits a Nernstian slope, within a linear range of response from 1 to 50 mM CRE concentration. As expected, the response time (15–60 min) primarily depends on the CRE diffusion across the AEM. CRE analysis in urine samples displayed excellent results, without requiring sample pretreatment (before the introduction of the sample in the microfluidic chip) and with high compatibility with development into a potential point-of-care clinical tool. In an attempt to decrease the analysis time, the presented analytical methodology for CRE detection is translated into an all-solid-state platform, in which the enzyme is immobilized on the surface of the ammonium-selective electrode and with the AEM on top. While more work is necessary in this direction, the CRE sensor appears to be promising for CRE analysis in both urine and blood.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.9B05231
|
|
|
“Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging”. Vincze L, Vekemans B, Brenker FE, Falkenberg G, Rickers K, Somogyi A, Kersten M, Adams F, Analytical chemistry 76, 6786 (2004). http://doi.org/10.1021/AC049274L
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC049274L
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 78, 4069 (2006). http://doi.org/10.1021/AC060688J
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC060688J
|
|
|
“X-ray spectrometry”. Szalóki I, Osán J, Van Grieken RE, Analytical chemistry 76, 3445 (2004). http://doi.org/10.1021/AC0400820
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC0400820
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Injuk J, Van Grieken RE, Analytical chemistry 74, 2895 (2002). http://doi.org/10.1021/AC020241K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC020241K
|
|
|
“X-ray spectrometry”. Szalóki I, Török SB, Ro C-U, Injuk J, Van Grieken RE, Analytical chemistry 72, 211 (2000). http://doi.org/10.1021/A1000018H
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/A1000018H
|
|
|
“X-ray spectrometry”. Török S, Labar J, Schmeling M, Van Grieken R, Analytical chemistry 70, 495r (1998)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Török SB, Labar J, Injuk J, Van Grieken RE, Analytical chemistry R68, 467 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Török SB, Van Grieken RE, Analytical chemistry 64r, 180 (1992)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 62, 101r (1990). http://doi.org/10.1021/AC00211A001
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00211A001
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 60, 28r (1988). http://doi.org/10.1021/AC00163A002
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00163A002
|
|
|
“X-ray spectrometry”. Markowicz AA, Van Grieken RE, Analytical chemistry 58, 279r (1986). http://doi.org/10.1021/AC00296A019
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00296A019
|
|
|
“Micro to nano : multiscale IR analyses reveal zinc soap heterogeneity in a 19th-century painting by Corot”. Ma X, Pavlidis G, Dillon E, Beltran V, Schwartz JJ, Thoury M, Borondics F, Sandt C, Kjoller K, Berrie BH, Centrone A, Analytical chemistry 94, 3103 (2022). http://doi.org/10.1021/ACS.ANALCHEM.1C04182
Abstract: Formation and aggregation of metal carboxylates (metal soaps) can degrade the appearance and integrity of oil paints, challenging efforts to conserve painted works of art. Endeavors to understand the root cause of metal soap formation have been hampered by the limited spatial resolution of Fourier transform infrared microscopy (mu-FTIR). We overcome this limitation using optical photothermal infrared spectroscopy (O-PTIR) and photothermal-induced resonance (PTIR), two novel methods that provide IR spectra with approximate to 500 and approximate to 10 nm spatial resolutions, respectively. The distribution of chemical phases in thin sections from the top layer of a 19th-century painting is investigated at multiple scales (mu-FTIR approximate to 10(2) mu m(3), O-PTIR approximate to 10(-1) mu m(3), PTIR approximate to 10(-5) mu m(3)). The paint samples analyzed here are found to be mixtures of pigments (cobalt green, lead white), cured oil, and a rich array of intermixed, small (often << 0.1 mu m(3)) zinc soap domains. We identify Zn stearate and Zn oleate crystalline soaps with characteristic narrow IR peaks (approximate to 1530-1558 cm(-1)) and a heterogeneous, disordered, water-permeable, tetrahedral zinc soap phase, with a characteristic broad peak centered at approximate to 1596 cm(-1). We show that the high signal-to-noise ratio and spatial resolution afforded by O-PTIR are ideal for identifying phase-separated (or locally concentrated) species with low average concentration, while PTIR provides an unprecedented nanoscale view of distributions and associations of species in paint. This newly accessible nanocompositional information will advance our knowledge of chemical processes in oil paint and will stimulate new art conservation practices.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1021/ACS.ANALCHEM.1C04182
|
|
|
“Chemical mapping of the degradation of geranium lake in paint cross sections by MALDI-MSI”. Alvarez-Martin A, Quanico J, Scovacricchi T, Avranovich Clerici E, Baggerman G, Janssens K, Analytical chemistry 95, 18215 (2023). http://doi.org/10.1021/ACS.ANALCHEM.3C03992
Abstract: Matrix assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) has become a powerful method to extract spatially resolved chemical information in complex materials. This study provides the first use of MALDI-MSI to define spatial–temporal changes in oil paints. Due to the highly heterogeneous nature of oil paints, the sample preparation had to be optimized to prevent molecules from delocalizing. Here, we present a new protocol for the layer-specific analysis of oil paint cross sections achieving a lateral resolution of 10 μm and without losing ionization efficiency due to topographic effects. The efficacy of this method was investigated in oil paint samples containing a mixture of two historic organic pigments, geranium lake and lead white, a mixture often employed in the work of painter Vincent Van Gogh. This methodology not only allows for spatial visualization of the molecules responsible for the pink hue of the paint but also helps to elucidate the chemical changes behind the discoloration of paintings with this composition. The results demonstrate that this approach provides valuable molecular compositional information about the degradation pathways of pigments in specific paint layers and their interaction with the binding medium and other paint components and with light over time. Since a spatial correlation between molecular species and the visual pattern of the discoloration pattern can be made, we expect that mass spectrometry imaging will become highly relevant in future degradation studies of many more historical pigments and paints.
Keywords: A1 Journal article; Antwerp X-ray Imaging and Spectroscopy (AXIS); Ecosphere
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C03992
|
|
|
“Dual microfluidic sensor system for enriched electrochemical profiling and identification of illicit drugs on-site”. Steijlen ASM, Parrilla M, Van Echelpoel R, De Wael K, Analytical chemistry 96, 590 (2024). http://doi.org/10.1021/ACS.ANALCHEM.3C05039
Abstract: Electrochemical sensors have emerged as a new analytical tool for illicit drug detection to facilitate ultrafast and accurate identification of suspicious compounds on-site. Drugs of abuse can be identified using their unique voltammetric fingerprint at a given pH. Today, the right buffer solution is manually selected based on drug appearance, and in some cases, a consecutive analysis in two different pH solutions is required. In this work, we present a disposable microfluidic multichannel sensor system that automatically records fingerprints in two pH solutions (e.g., pH 5 and pH 12). This system has two advantages. It will overcome the manual selection of a buffer solution at the right pH, decrease analysis time, and minimize the risk of human errors. Second, the combination of two fingerprints, the superfingerprint, contains more detailed information about the samples, which enhances the selectivity of the analytical technique. First, real-time pH measurements proved that the sample can be brought to the desired pH within a minute. Subsequently, an electrochemical study on the microfluidic platform with 1 mM illicit drug standards of MDMA, cocaine, heroin, and methamphetamine showed that the characteristic voltammetric fingerprints and peak potentials are reproducible, also in the presence of common cutting agents. Finally, the microfluidic concept was validated with real confiscated samples, showing promising results for the user-friendly identification of drugs of abuse. In short, this paper presents a successful proof-of-concept study of a multichannel microfluidic sensor system to enrich the fingerprints of illicit drugs at pH 5 and pH 12, thus providing a low-cost, portable, and rapid identification system of illicit drugs with minimal user intervention.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 7.4
DOI: 10.1021/ACS.ANALCHEM.3C05039
|
|
|
“Air particulate emissions in developing countries : a case study in South Africa”. Worobiec A, Potgieter-Vermaak SS, Berghmans P, Winkler H, Burger R, Van Grieken R, Analytical letters 44, 1907 (2011). http://doi.org/10.1080/00032719.2010.539734
Abstract: Atmospheric aerosols were collected during the winter in Bethlehem, South Africa. The particulate mass concentrations, ambient carbon mass concentrations, and chemical composition of various particulate fractions showed that the area is highly polluted. The fine particle mass concentrations peaked at 1000 µg/m3 for PM2.5. Ambient carbon mass concentrations ranged from 20 to 40 µg/m3. Single particle analysis confirmed that the fine particle fraction was dominated by organic particles. The topographical conditions, causing a low inversion, together with the high amounts of emissions from biomass burning, result in unacceptable levels of air pollution and pose a considerable health threat to the population.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1080/00032719.2010.539734
|
|
|
“Identifying alternative ferroelectric materials beyond Hf(Zr)O-₂”. Guo J, Clima S, Pourtois G, Van Houdt J, Applied Physics Letters 117, 262903 (2020). http://doi.org/10.1063/5.0028611
Abstract: A database-driven approach combined with ab initio density functional theory (DFT) simulations is used to identify and simulate alternative ferroelectric materials beyond Hf(Zr)O-2. The database-driven screening method identifies a class of wurtzite ferroelectric materials. DFT simulations of wurtzite magnesium chalcogenides, including MgS, MgSe, and MgTe, show their potential to achieve improved ferroelectric (FE) stability, simple atomistic unit cell structure, and large FE polarization. Strain engineering can effectively modulate the FE switching barrier height for facilitating FE switching. The effect of the piezoelectric property on the FE switching barrier heights is also examined.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4
DOI: 10.1063/5.0028611
|
|
|
“A Dirac-semimetal two-dimensional BeN4 : thickness-dependent electronic and optical properties”. Bafekry A, Stampfl C, Faraji M, Yagmurcukardes M, Fadlallah MM, Jappor HR, Ghergherehchi M, Feghhi SAH, Applied Physics Letters 118, 203103 (2021). http://doi.org/10.1063/5.0051878
Abstract: Motivated by the recent experimental realization of a two-dimensional (2D) BeN4 monolayer, in this study we investigate the structural, dynamical, electronic, and optical properties of a monolayer and few-layer BeN4 using first-principles calculations. The calculated phonon band dispersion reveals the dynamical stability of a free-standing BeN4 layer, while the cohesive energy indicates the energetic feasibility of the material. Electronic band dispersions show that monolayer BeN4 is a semi-metal whose conduction and valence bands touch each other at the Sigma point. Our results reveal that increasing the layer number from single to six-layers tunes the electronic nature of BeN4. While monolayer and bilayer structures display a semi-metallic behavior, structures thicker than that of three-layers exhibit a metallic nature. Moreover, the optical parameters calculated for monolayer and bilayer structures reveal that the bilayer can absorb visible light in the ultraviolet and visible regions better than the monolayer structure. Our study investigates the electronic properties of Dirac-semimetal BeN4 that can be an important candidate for applications in nanoelectronic and optoelectronic. Published under an exclusive license by AIP Publishing.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.411
DOI: 10.1063/5.0051878
|
|
|
“Electronic and magnetic properties of two-dimensional of FeX (X = S, Se, Te) monolayers crystallize in the orthorhombic structures”. Bafekry A, Sarsari IA, Faraji M, Fadlallah MM, Jappor HR, Karbasizadeh S, Nguyen V, Ghergherehchi M, Applied Physics Letters 118, 143102 (2021). http://doi.org/10.1063/5.0046721
Abstract: In this Letter, we explore the lattice, dynamical stability, and electronic and magnetic properties of FeTe bulk and FeX (X=S, Se, Te) monolayers using the density functional calculations. The phonon dispersion relation, elastic stability criteria, and cohesive energy results show the stability of studied FeX monolayers. The mechanical properties reveal that all FeX monolayers have a brittle nature. Furthermore, these structures are stable as we move down the 6A group in the periodic table, i.e., from S, Se, and Te. The stability and work function decrease as the electronegativity decreases. The spin-polarized electronic structures demonstrate that the FeTe monolayer has a total magnetization of 3.8 mu (B), which is smaller than the magnetization of FeTe bulk (4.7 mu (B)). However, FeSe and FeS are nonmagnetic monolayers. The FeTe monolayer can be a good candidate material for spin filter applications due to its electronic and magnetic properties. This study highlights the bright prospect for the application of FeX monolayers in electronic structures.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 3.411
DOI: 10.1063/5.0046721
|
|
|
“Micromagnetic simulations of magnetoelastic spin wave excitation in scaled magnetic waveguides”. Duflou R, Ciubotaru F, Vaysset A, Heyns M, Sorée B, Radu IP, Adelmann C, Applied physics letters 111, 192411 (2017). http://doi.org/10.1063/1.5001077
Abstract: We study the excitation of spin waves in scaled magnetic waveguides using the magnetoelastic effect. In uniformly magnetized systems, normal strains parallel or perpendicular to the magnetization direction do not lead to spin wave excitation since the magnetoelastic torque is zero. Using micromagnetic simulations, we show that the nonuniformity of the magnetization in submicron waveguides due to the effect of the demagnetizing field leads to the excitation of spin waves for oscillating normal strains both parallel and perpendicular to the magnetization. The excitation by biaxial normal in-plane strain was found to be much more efficient than that by uniaxial normal out-of-plane strain. For narrow waveguides with a width of 200 nm, the excitation efficiency of biaxial normal in-plane strain was comparable to that of shear strain. Published by AIP Publishing.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
DOI: 10.1063/1.5001077
|
|