Records |
Links |
|
Author |
Autrique, D.; Bogaerts, A.; Lindner, H.; Garcia, C.C.; Niemax, K. |
|
|
Title |
Design analysis of a laser ablation cell for inductively coupled plasma mass spectrometry by numerical simulation |
Type |
A1 Journal article |
|
Year |
2008 |
Publication |
Spectrochimica acta: part B : atomic spectroscopy |
Abbreviated Journal |
Spectrochim Acta B |
|
|
Volume |
63 |
Issue |
2 |
Pages |
257-270 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Oxford |
Editor |
|
|
|
Language |
|
Wos |
000254038900016 |
Publication Date |
2007-12-05 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0584-8547; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
3.241 |
Times cited |
26 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 3.241; 2008 IF: 2.853 |
|
|
Call Number |
UA @ lucian @ c:irua:67086 |
Serial |
656 |
|
Permanent link to this record |
|
|
|
|
Author |
Lindner, H.; Autrique, D.; Garcia, C.C.; Niemax, K.; Bogaerts, A. |
|
|
Title |
Optimized transport setup for high repetition rate pulse-separated analysis in laser ablation-inductively coupled plasma mass spectrometry |
Type |
A1 Journal article |
|
Year |
2009 |
Publication |
Analytical chemistry |
Abbreviated Journal |
Anal Chem |
|
|
Volume |
81 |
Issue |
11 |
Pages |
4241-4248 |
|
|
Keywords |
A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT) |
|
|
Abstract |
An optimized laser ablation setup, proposed for high repetition rate inductively coupled plasma mass spectrometry (ICPMS) analyses such as 2D imaging or depth profiling, is presented. For such applications, the particle washout time needs to be as short as possible to allow high laser pulse frequencies for reduced analysis time. Therefore, it is desirable to have an ablation setup that operates as a laminar flow reactor (LFR). A top-down strategy was applied that resulted in the present design. In the first step, a previously applied ablation setup was analyzed on the basis of computational fluid dynamics (CFD) results presented by D. Autrique et al. (Spectrochim. Acta, B 2008, 63, 257−270). By means of CFD simulations, the design was modified in such a way that it operated in the LFR regime. Experimental results demonstrate that the current design can indeed be regarded as an LFR. Furthermore, the operation under LFR conditions allowed some insight into the initial radial concentration distribution if the experimental ICPMS signal and analytical expressions are taken into account. Recommendations for a modified setup for more resilient spatial distributions are given. With the present setup, a washout time of 140 ms has been achieved for a 3% signal area criterion. Therefore, 7 Hz repetition rates can be applied with the present setup. Using elementary formulas of the analytical model, an upper bound for the washout times for similar setups can be predicted. The authors believe that the presented setup geometry comes close to the achievable limit for reliable short washout times. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
Washington, D.C. |
Editor |
|
|
|
Language |
|
Wos |
000266601800014 |
Publication Date |
2009-04-29 |
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0003-2700;1520-6882; |
ISBN |
|
Additional Links |
UA library record; WoS full record; WoS citing articles |
|
|
Impact Factor |
6.32 |
Times cited |
18 |
Open Access |
|
|
|
Notes |
|
Approved |
Most recent IF: 6.32; 2009 IF: 5.214 |
|
|
Call Number |
UA @ lucian @ c:irua:76935 |
Serial |
2492 |
|
Permanent link to this record |