“Multiscale modeling of radiation damage and annealing in Si samples implanted with 57-Mn radioactive ions”. Abreu Y, Cruz CM, van Espen P, Piñera I, Leyva A, Cabal AE, IEEE conference record
T2 –, IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th, International Workshop on Room-Temperature Semiconductor X-Ray and, Gamma-Ray Detectors, OCT 23-29, 2011, Valencia, SPAIN , 1754 (2011)
Abstract: The radiation damage created in silicon materials by Mn-57 -> Fe-57 ion implantation has been studied and characterized by Mossbauer spectroscopy showing four main lines, assigned to: substitutional, interstitial and damaged configuration sites of the implanted ions. Nevertheless, the Mossbauer spectrum of Fe-57 in this materials remains with some ambiguous identification regarding the implantation configurations before and after annealing, specially the damaged configurations and its evolution. In the present work some possible implantation configurations are suggested and evaluated using a multiscale approach by Monte Carlo ion transport and electronic structure calculations within DFT. The proposed implantation environments were evaluated in terms of stability and the Fe-57 hyperfine parameters were calculated to establish the connections with the experimental observations. Good agreement was found between the experimental and the calculated hyperfine parameters for some configurations; suggesting which ones could be the implantation environments before and after sample annealing.
Keywords: P1 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Radiation damage evaluation on LYSO and LuYAP materials through Dpa calculation assisted by Monte Carlo method”. Piñera I, Abreu Y, van Espen P, Diaz A, Leyva A, Cruz CM, IEEE conference record
T2 –, IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th, International Workshop on Room-Temperature Semiconductor X-Ray and, Gamma-Ray Detectors, OCT 23-29, 2011, Valencia, SPAIN , 1609 (2011)
Abstract: The aim of the present work is to study the radiation damage induced in LYSO and LuYAP crystals by the gamma radiation and the secondary electrons/positrons generated. The displacements per atom (dpa) distributions inside each material were calculated following the Monte Carlo assisted Classical Method (MCCM) introduced by the authors. As gamma sources were used Sc-44, Na-22 and V-48. Also the energy of gammas from the annihilation processes (511 keV) was included in the study. This procedure allowed studying the in-depth dpa distributions inside each crystal for all four sources. It was also possible to obtain the separate contribution from each atom to the total dpa. The LYSO crystals were found to receive more damage, mainly provoked by the displacements of silicon and oxygen atoms.
Keywords: P1 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
“Euroanalysis 14: the European Conference on Analytical Chemistry”. Janssens K, van Espen P, Van 't dack L, Analytical and bioanalytical chemistry 391, 1107 (2008). http://doi.org/10.1007/S00216-008-2114-9
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 3.431
DOI: 10.1007/S00216-008-2114-9
|
“Large-area elemental imaging reveals Van Eyck's original paint layers on the Ghent altarpiece (1432), rescoping its conservation treatment”. van der Snickt G, Dubois H, Sanyova J, Legrand S, Coudray A, Glaude C, Postec M, van Espen P, Janssens K, Angewandte Chemie: international edition in English 56, 4797 (2017). http://doi.org/10.1002/ANIE.201700707
Abstract: A combination of large-scale and micro-scale elemental imaging, yielding elemental distribution maps obtained by, respectively non-invasive macroscopic X-ray fluorescence (MA-XRF) and by secondary electron microscopy/energy dispersive X-ray analysis (SEM-EDX) and synchrotron radiation-based micro-XRF (SR m-XRF) imaging was employed to reorient and optimize the conservation strategy of van Eyck's renowned Ghent Altarpiece. By exploiting the penetrative properties of X-rays together with the elemental specificity offered by XRF, it was possible to visualize the original paint layers by van Eyck hidden below the overpainted surface and to simultaneously assess their condition. The distribution of the high-energy Pb-L and Hg-L emission lines revealed the exact location of hidden paint losses, while Fe-K maps demonstrated how and where these lacunae were filled-up using an iron-containing material. The chemical maps nourished the scholarly debate on the overpaint removal with objective, chemical arguments, leading to the decision to remove all skillfully applied overpaints, hitherto interpreted as work by van Eyck. MA-XRF was also employed for monitoring the removal of the overpaint during the treatment phase. To gather complementary information on the in-depth layer build-up, SEM-EDX and SR mu-XRF imaging was used on paint cross sections to record microscale elemental maps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 11.994
Times cited: 11
DOI: 10.1002/ANIE.201700707
|
“Seasonal trends of atmospheric nitrogen dioxide and sulfur dioxide over North Santa Clara, Cuba”. Alejo D, Morales MC, de la Torre JB, Grau R, Bencs L, Van Grieken R, van Espen P, Sosa D, Nuñez V, Environmental monitoring and assessment 185, 6023 (2013). http://doi.org/10.1007/S10661-012-3003-4
Abstract: Atmospheric nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels were monitored simultaneously by means of Radiello passive samplers at six sites of Santa Clara city, Cuba, in the cold and the warm seasons in 2010. The dissolved ionic forms of NO2 and SO2 as nitrate and sulfite plus sulfate, respectively, were determined by means of ion chromatography. Analysis of NO2 as nitrite was also performed by UVVis spectrophotometry. For NO2, significant t tests show good agreement between the results of IC and UVVis methods. The NO2 and SO2 concentrations peaked in the cold season, while their minimum levels were experienced in the warm season. The pollutant levels do not exceed the maximum allowable limit of the Cuban Standard 39:1999, i.e., 40 μg/m3 and 50 μg/m3 for NO2 and SO2, respectively. The lowest pollutant concentrations obtained in the warm season can be attributed to an increase in their removal via precipitation (scavenging) while to the decreased traffic density and industrial emission during the summer holidays (e.g., July and August).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-012-3003-4
|
“A new electrostatic transfer line for improved transmission in Fourier transform laser microprobe mass spectrometry with external ion source”. van Vaeck L, van Espen P, Gijbels R, Baykut G, Laukien FH, European mass spectrometry 6, 277 (2000). http://doi.org/10.1255/ejms.342
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 10
DOI: 10.1255/ejms.342
|
“Modeling the charge deposition in quartz grains during natural irradiation and its influence on the optically stimulated luminescence signal”. Baly L, Quesada I, Murray AS, Martin G, van Espen P, Arteche R, Jain M, Radiation Measurements 142, 106564 (2021). http://doi.org/10.1016/J.RADMEAS.2021.106564
Abstract: The rate of charge deposition in quartz grains irradiated in natural conditions is computed by radiation transport modeling. Quartz luminescence models are modified with the addition of the resulting charge deposition term, and the influence of this process on the optically stimulated luminescence (OSL) signal is analyzed. The results indicate that the charge deposition occurring in the quartz grain during the time of residence within rock could lead to the depletion of trapped holes in the recombination centres. For the two different quartz models investigated here, complete depletion is expected to occur for rock ages between 500 Ma and 1100 Ma. It is predicted that for sedimentary quartz derived from such rocks, the OSL signal is dominated by the slow component. It was also found that the shape and saturation level of the natural sensitivity-corrected dose response curve (DRC) of quartz is affected by the charge deposition; specifically, a linear reduction of the saturation level with the age of the rock is observed.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.442
DOI: 10.1016/J.RADMEAS.2021.106564
|
“Classification of coal mine dust particles through fuzzy clustering of their energy-dispersive electron microprobe X-ray spectra”. Bondarenko I, van Espen P, Treiger B, Van Grieken R, Adams F, Microbeam analysis 3, 33 (1994)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Background aerosol composition at Gobabeb, South West Africa”. Annegarn H, Van Grieken R, van Espen P, von Blottnitz F, Sellschop J, Winchester J, Maenhaut W, Madoqua , 107 (1976)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Hyperfine electric parameters calculation in Si samples implanted with 57Mn\rightarrow57Fe”. Abreu Y, Cruz CM, Pinera I, Leyva A, Cabal AE, van Espen P, Van Remortel N, Physica: B : condensed matter 445, 1 (2014). http://doi.org/10.1016/J.PHYSB.2014.03.028
Abstract: Nowadays the electronic structure calculations allow the study of complex systems determining the hyperfine parameters measured at a probe atom, including the presence of crystalline defects. The hyperfine electric parameters have been measured by Mossbauer spectroscopy in silicon materials implanted with Mn-57 ->,Fe-57 ions, observing four main contributions to the spectra. Nevertheless, some ambiguities still remain in the Fe-57 Mossbauer spectra interpretation in this case, regarding the damage configurations and its evolution with annealing. In the present work several implantation environments are evaluated and the Fe-57 hyperfine parameters are calculated. The observed correlation among the studied local environments and the experimental observations is presented, and a tentative microscopic description of the behavior and thermal evolution of the characteristic defects local environments of the probe atoms concerning the location of vacancies and interstitial Si in the neighborhood of Fe-57 ions in substitutional and interstitial sites is proposed. (C) 2014 Elsevier B.V. All rights reserved
Keywords: A1 Journal article; Particle Physics Group; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.PHYSB.2014.03.028
|
“The primary energy dependence of backscattered electron images up to 100 keV”. Geuens I, Nys B, Naudts J, Gijbels R, Jacob W, van Espen P, Scanning microscopy 5, 339 (1991)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 3
|
“Quantitative analysis of 16-17th century archaeological glass vessels using PLS regression of EPXMA and μ-XRF data”. Lemberge P, Deraedt I, Janssens K, van Espen P, Journal of chemometrics 14, 751 (2000). http://doi.org/10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 1.884
DOI: 10.1002/1099-128X(200009/12)14:5/6<751::AID-CEM622>3.0.CO;2-D
|
“Determination of fluorine in uranium oxyfluoride particles as an indicator of particle age”. Kips R, Pidduck AJ, Houlton MR, Leenaers A, Mace JD, Marie O, Pointurier F, Stefaniak EA, Taylor PDP, van den Berghe S, van Espen P, Van Grieken R, Wellum R, Spectrochimica acta: part B : atomic spectroscopy 64, 199 (2009). http://doi.org/10.1016/J.SAB.2008.12.001
Abstract: As swipe samples from enrichment activities typically contain uranium particles with a detectable amount of fluorine, the question was raised whether the analysis of fluorine in particles could complement the information on the uranium isotope ratios. For this, uranium oxyfluoride particles were prepared from the controlled hydrolysis of uranium hexafluoride (UF6). The relative amount of fluorine was characterized by scanning electron microscopy combined with energy-dispersive X-ray spectrometry (SEM-EDX), as well as ion-microprobe secondary ion mass spectrometry (IM-SIMS). Of particular interest was the assessment of the reduction of the amount of fluorine over time, and after exposure to UV-light and high temperatures. Micro-Raman spectrometry (MRS) was applied to look for differences in molecular structure between these various sample types. Both SEM-EDX and IM-SIMS showed a general reduction of the fluorine-to-uranium ratio after 12 years of storage. The exposure to UV-light and high temperatures was found to have accelerated the loss of fluorine. A distinct peak at 865 cm− 1 Raman shift was detected for the majority of particles analyzed by MRS. For the particles that were heat-treated, the Raman spectra were similar to the spectrum of U3O8. Although often large variations were observed between particles from the same sample, the three particle measurement techniques (IM-SIMS, SEM-EDX and MRS) showed some consistent trends. They therefore appear promising in terms of the ability to place bounds on particle age, as well as shedding light on the complex processes involved in UO2F2 particle ageing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/J.SAB.2008.12.001
|
“IDAS: a Windows based software package for cluster analysis”. Bondarenko I, Treiger B, Van Grieken R, van Espen P, Spectrochimica acta: part B : atomic spectroscopy 51, 441 (1996)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Non-linear mapping of microbeam proton-induced X-ray emission data for source identification of North Sea aerosols”. Treiger B, Injuk J, Bondarenko I, van Espen P, Van Grieken R, Breitenbach L, Wätjen U, Spectrochimica acta: part B : atomic spectroscopy 49, 345 (1994). http://doi.org/10.1016/0584-8547(94)80029-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0584-8547(94)80029-4
|
“Study of a unique 16th century Antwerp majolica floor in the Rameyenhof castle's chapel by means of X-ray fluorescence and portable Raman analytical instrumentation”. Van de Voorde L, Vandevijvere M, Vekemans B, Van Pevenage J, Caen J, Vandenabeele P, van Espen P, Vincze L, Spectrochimica acta: part B : atomic spectroscopy 102, 28 (2014). http://doi.org/10.1016/J.SAB.2014.10.007
Abstract: The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles – an element that was not used for making 16th century majolica – valuable information about the originality of the chapel floor and the two central medallions is acquired. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.SAB.2014.10.007
|
“Concentration profiles of metal contaminants in fluvial sediments of a rural-urban drainage basin in Tanzania”. Hellar-Kihampa H, Potgieter-Vermaak S, De Wael K, Lugwisha E, van Espen P, Van Grieken R, International journal of environmental analytical chemistry 94, 77 (2014). http://doi.org/10.1080/03067319.2013.791976
Abstract: This study investigated concentration profiles of trace, rare earth and platinum group metals in fluvial sediments from the Pangani river basin (43,650 km2), one of the largest river basins in Tanzania, to assess its environmental quality. Sediment samples were collected in two distinct seasons from 12 representative sites of diverse land-use practices and characterised by ICP-MS after optimised microwave digestion. Ecological risks were assessed by evaluation of pollution index and comparison with legislated sediment quality guidelines (SQG). The results revealed contamination by some trace metals (e.g. Pb, V, Cu, Cr, Ni, Cd, As, Co, Mn and Zn) in concentrations ranging from 0.7 to 2940 mg kg−1, and four rare earth elements (Y, Ce, Nd, Yb) in concentrations ranging from 0.9 (Yb) to 500 mg kg−1 dry weight (Ce), which significantly exceeded the estimated background values at some stations. Palladium was the only platinum group element that was detected in quantifiable concentrations (0.33.5 mg kg−1). Concentrations of some trace metals exceeded the SQGs at some localised areas. Principal component analysis and multivariate correlations indicated geochemical characteristics of the area as the major control of metal concentrations and spatial variability. Organic matter and clay contents also played a significant role in metal distributions. Assessment of land-use practices upstream of the sampling locations was used to trace potential anthropogenic sources of metal enrichments, where highest levels were found in areas close to urban centres and agricultural activities. The study provides baseline data for future monitoring programs, and highlights the need for more comprehensive analysis involving a wider spatio-temporal scale and ecotoxicological risk assessment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.208
Times cited: 5
DOI: 10.1080/03067319.2013.791976
|
“Improved radiographic methods for the investigation of paintings using laboratory and synchrotron X-ray sources”. Schalm O, Cabal A, van Espen P, Laquière N, Storme P, Journal of analytical atomic spectrometry 26, 1068 (2011). http://doi.org/10.1039/C0JA00242A
Abstract: It is generally known that radiographic inspection of 1517th century paintings can easily be done with a polychromatic X-ray source using a voltage between 20 kV and 40 kV in combination with classic X-ray films. Unfortunately, the spatial structure of numerous 19th and early 20th century paintings cannot be visualized with conventional radiography due to several reasons such as the use of lead white grounds or low absorbing pigments. Radiographic images are blurred or worse, they do not contain the picture of the painting. During the last decades, many technological innovations have been introduced in the field of radiography but their possibilities in cultural heritage have not been explored in full detail. In our investigation we used phosphor imaging plates, energy dispersive detectors and CCD-cameras in combination with synchrotron radiation and conventional X-ray tubes in order to improve the quality of radiographic images. Several promising techniques that could improve the quality of radiographs of paintings were identified.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/C0JA00242A
|
“Case specific prediction intervals for tri-PLS1 : the full local linearisation”. Serneels S, Faber K, Verdonck T, van Espen PJ, Chemometrics and intelligent laboratory systems 108, 93 (2011). http://doi.org/10.1016/J.CHEMOLAB.2011.05.002
Abstract: A new method to estimate case specific prediction uncertainty for univariate trilinear partial least squares (tri-PLS1) regression is introduced. This method is, from a theoretical point of view, the most exact finite sample approximation to true prediction uncertainty that has been reported up till now. Using the new method, different error sources can be propagated, which is an advantage that cannot be offered by data driven approaches such as the bootstrap. In a concise example, it is illustrated how the method can be applied. In the Appendix, efficient algorithms are presented to compute the estimates required.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHEMOLAB.2011.05.002
|
“AXIL-PC, software for the analysis of complex-x-ray spectra”. van Espen P, Janssens K, Nobels J, Chemometrics and intelligent laboratory systems 1, 109 (1986). http://doi.org/10.1016/0169-7439(86)80031-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(86)80031-4
|
“PC-MCA : a software package for the acquisition and processing of spectral data”. Janssens K, Nobels J, van Espen P, Chemometrics and intelligent laboratory systems 3, 335 (1988). http://doi.org/10.1016/0169-7439(88)80033-9
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80033-9
|
“The development process of an expert system for the automated interpretation of large epma data sets”. Janssens K, Dorrine W, van Espen P, Chemometrics and intelligent laboratory systems 4, 147 (1988). http://doi.org/10.1016/0169-7439(88)80086-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0169-7439(88)80086-8
|
“Accurate evaluation of \mu-PIXE and \mu-XRF spectral data through iterative least squares fitting”. Janssens K, Vekemans B, Adams F, van Espen P, Mutsaers P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms
T2 –, 7th International Conference on Particle Induced X-ray Emission and Its Analytical Applications, MAY 26-30, 1995, Abano Terme, Italy 109, 179 (1996). http://doi.org/10.1016/0168-583X(95)01211-7
Abstract: The integration of the nonlinear least squares X-ray spectrum evaluation progam AXIL. into a mu-PIXE and a mu-XRF setup is discussed. The use of the software when procesing data sets derived from biological and geological samples is described.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0168-583X(95)01211-7
|
“Gamma induced atom displacements in LYSO and LuYAP crystals as used in medical imaging applications”. Pinera I, Cruz CM, Abreu Y, Leyva A, van Espen P, Diaz A, Cabal AE, Van Remortel N, Interactions With Materials And Atoms 356, 46 (2015). http://doi.org/10.1016/J.NIMB.2015.04.063
Abstract: The radiation damage, in terms of atom displacements, induced by gamma irradiation in LYSO and LuYAP crystals is presented. Sc-44, Na-22 and V-48 are used as gamma sources for this study. The energy of gammas from the electron positron annihilation processes (511 keV) is also included in the study. The atom displacements distributions inside each material are calculated following the Monte Carlo assisted Classical Method introduced by the authors. This procedure also allows to study the atom displacements in-depth distributions inside each crystal. The atom displacements damage in LYSO crystals is found to be higher than in LuYAP crystals, mainly provoked by the displacements of silicon and oxygen atoms. But the difference between atom displacements produced in LYSO and LuYAP decreases when more energetic sources are used. On the other hand, the correlation between the atom displacements and energy deposition in-depth distributions is excellent. The atom displacements to energy deposition ratio is found to increases with more energetic photon sources. LYSO crystals are then more liable to the atom displacements damage than LuYAP crystals. (C) 2015 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Particle Physics Group; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2015.04.063
|
“Improved calculation of displacements per atom cross section in solids by gamma and electron irradiation”. Pinera I, Cruz CM, Leyva A, Abreu Y, Cabal AE, van Espen P, Van Remortel N, Interactions With Materials And Atoms 339, 1 (2014). http://doi.org/10.1016/J.NIMB.2014.08.020
Abstract: Several authors had estimated the displacements per atom cross sections under different approximations and models, including most of the main gamma- and electron-material interaction processes. These previous works used numerical approximation formulas which are applicable for limited energy ranges. We proposed the Monte Carlo assisted Classical Method (MCCM), which relates the established theories about atom displacements to the electron and positron secondary fluence distributions calculated from the Monte Carlo simulation. In this study the MCCM procedure is adapted in order to estimate the displacements per atom cross sections for gamma and electron irradiation. The results obtained through this procedure are compared with previous theoretical calculations. An improvement in about 10-90% for the gamma irradiation induced dpa cross section is observed in our results on regard to the previous evaluations for the studied incident energies. On the other hand, the dpa cross section values produced by irradiation with electrons are improved by our calculations in about 5-50% when compared with the theoretical approximations. When thin samples are irradiated with electrons, more precise results are obtained through the MCCM (in about 20-70%) with respect to the previous studies. (C) 2014 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Particle Physics Group; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2014.08.020
|
“Monte Carlo simulation of X-ray spectra from low energy electrons using optical data”. Roet D, van Espen P, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 268, 2794 (2010). http://doi.org/10.1016/J.NIMB.2010.07.004
Abstract: An approach using optical data to simulate both the bremsstrahlung continuum and characteristic K and L X-ray lines generated by low energy electrons (cfr. electron microscopy) in solids is discussed in this paper. The necessary analytical expressions together with the data to calculate the relevant cross sections for elastic and inelastic interactions at these energies along with variance reduction techniques are given. The results of the Monte Carlo simulation are compared to experimental data measured with a JEOL 6300 electron microscope.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2010.07.004
|
“Study of dpa distributions in electron irradiated YBCO slabs through MCCM algorithm”. Piñera I, Cruz CM, van Espen P, Abreu Y, Leyva A, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 274, 191 (2012). http://doi.org/10.1016/J.NIMB.2011.11.021
Abstract: The Monte Carlo assisted Classical Method (MCCM) consists on a calculation procedure for determining the displacements per atom (dpa) distribution in solid materials. This algorithm allows studying the gamma and electron irradiation damage in different materials. It is based on the electrons elastic scattering classic theories and the use of Monte Carlo simulation for the physical processes involved. The present study deals with the Monte Carlo simulation of electron irradiation effects on YBa2Cu3O7-x (YBCO) slabs using the MCNPX code system. Displacements per atom distributions are obtained through the MCCM for electron irradiation up to 10 MeV. In-depth dpa profiles for electrons and positrons are obtained and analysed. Also, dpa contributions from each atomic specie in the material are calculated. It was found that the dpa distribution is more homogeneous in the material volume when increasing energy of incident electrons. Also, the dpa produced by positrons has no relevance when irradiating with electrons, in contrast with previous similar gamma irradiation studies. All the results are presented and discussed in this contribution. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.NIMB.2011.11.021
|
“Characterization of individual soot aggregates from different sources using image analysis”. Smekens A, Godoi RHM, Vervoort M, van Espen P, Potgieter-Vermaak SS, Van Grieken R, Journal of atmospheric chemistry 56, 211 (2007). http://doi.org/10.1007/S10874-006-9050-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1007/S10874-006-9050-X
|
“A general-purpose interface between fortran and the low-level functions of the ibm-pc”. Janssens K, van Espen P, Trends in analytical chemistry 7, 128 (1988). http://doi.org/10.1016/0165-9936(88)87009-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0165-9936(88)87009-2
|