|
“Investigation of heavy metal distributions along 15m soil profiles using EDXRF, XRD, SEM-EDX, and ICP-MS techniques”. Ozen SA, Ozkalayci F, Cevik U, Van Grieken R, X-ray spectrometry 47, 231 (2018). http://doi.org/10.1002/XRS.2832
Abstract: The research of soil contamination by heavy metal is an important field due to its environmental and health implications. The goal was to study the elemental mobility as a function of depth. For this reason, the distribution of heavy metals (V, Cr, Co, Ni, Cu, Zn, As, Sn, and Pb) was investigated along soil profiles up to a depth of 15m at 9 sampling sites in the Nilufer industrial district (Bursa, Turkey). Elemental analyses were done with the Epsilon 5 energy dispersive X-ray fluorescence and inductively coupled plasma mass spectrometry equipment. Particle analysis was performed with a JEOL scanning electron microscope equipped with a Si(Li) X-ray detector. The crystallographic compositions of oxide compounds in soil samples were identified by a Rigaku X-ray diffraction instrument. Different parameters such as the soil's chemical (mineralogical structure, pH, and electrical conductivity) and physical properties (the number of blows, the stiffness index, the liquidity index, the plasticity index, and the water content) were analyzed. To assess the mobility of the heavy metals, diffusion (D) and convection coefficients (?) were calculated with the finite difference method. Convection was determined to dominate the studied region. In addition, the mobility coefficient was determined for each metal. High mobilities were determined for Zn and V, moderate mobilities for Cr, Ni, Cu, and As, and low mobilities were determined for Co and Pb. The results revealed that elements had reached depths of up to 15m, causing irreversible soil contamination that may lead to environmental health issues.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2832
|
|
|
“Investigation of heterogeneous reactions of PAH's on particle surfaces using laser microprobe mass analysis”. Niessner R, Klockow D, Bruynseels F, Van Grieken R, International journal of environmental analytical chemistry 22, 281 (1985). http://doi.org/10.1080/03067318508076427
Abstract: Artificially generated NaCl particles were coated with PAH's by using a condensation technique. These particles were exposed to reactive gases like ozone, bromine and nitrogen dioxide. The original as well as the exposed particles were investigated by fluorimetric analysis and by LAMMA (Laser Microprobe Mass Analysis) in the desorption mode, which allows the evaporation and characterization of surfaces of single particles. The results are interpreted in terms of possible heterogeneous atmospheric reactions. The reactivity of the considered PAH's towards nitrogen dioxide was found to be negligible. The structure of the reaction products formed with ozone was partially elucidated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318508076427
|
|
|
“Investigation of inclusions trapped inside Libyan desert glass by Raman microscopy”. Swaenen M, Stefaniak EA, Frost R, Worobiec A, Van Grieken R, Analytical and bioanalytical chemistry 397, 2659 (2010). http://doi.org/10.1007/S00216-009-3351-2
Abstract: Several specimens of Libyan desert glass (LDG), an enigmatic natural glass from Egypt, were subjected to investigation by micro-Raman spectroscopy. The spectra of inclusions inside the LDG samples were successfully measured through the layers of glass and the mineral species were identified on this basis. The presence of cristobalite as typical for high-temperature melt products was confirmed, together with co-existing quartz. TiO2 was determined in two polymorphic species rutile and anatase. Micro-Raman spectroscopy proved also the presence of minerals unusual for high-temperature glasses such as anhydrite and aragonite.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S00216-009-3351-2
|
|
|
“Investigation of individual particles and gaseous air pollutants in showcases”. Godoi RHM, Kontozova V, Godoi AFL, Van Grieken R page 147 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Investigation of the chemical composition of (Na1-xBix)(MnyNb1-y)O3 ceramics by single particle electron probe X-ray microanalysis with an application of Monte Carlo simulations”. Spolnik Z, Osán J, Klepka M, Lawniczak-Jablonska K, Van Grieken R, Molak A, Potgieter JH, Spectrochimica acta: part B : atomic spectroscopy 60, 525 (2005). http://doi.org/10.1016/J.SAB.2005.03.013
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2005.03.013
|
|
|
“Iron, copper, zinc and lead in hair from Sudanese populations of different age groups”. Eltayeb MAH, Van Grieken RE, The science of the total environment 95, 157 (1990). http://doi.org/10.1016/0048-9697(90)90061-X
Abstract: Energy-dispersive X-ray fluorescence was used for the analysis of hair samples from three different age groups of the Sudanese population. Hair samples were digested in a mixture of nitric and perchloric acids and the metals were then precipitated with ammonium pyrrolidine dithiocarbamate. The variations of the Fe, Cu, Zn and Pb content of hair with age were investigated. The averages of the elemental concentrations in each age group were compared with the other age groups and with literature values. The correlation of each pair of elements in the hair samples was also investigated.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90061-X
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
|
|
“Kultuurpatrimonium, zure regen en energie”. Van Grieken R, Fobe B, Energie en milieu: tijdschrift over energie en leefmilieu , 10 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“LAMMA analysis of inorganic ammonium compounds in individual marine aerosol particles”. Otten P, Bruynseels, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“LAMMA and electron-microprobe analysis of atmospheric aerosols”. Bruynseels F, Storms H, Van Grieken R, Journal de physique 45, 785 (1984). http://doi.org/10.1051/JPHYSCOL:19842180
Abstract: A laser microprobe mass analyser and a highly automated electron probe X-ray microanalysis unit have been used to study the elemental composition, inorganic speciation and morphology of atmospheric aerosols collected at various remote to polluted and marine to continental locations.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1051/JPHYSCOL:19842180
|
|
|
“LAMMA : calibration and application to nephrotoxicology studies”. Verbueken A, Paulus G, Van de Vyver F, Verpooten G, de Broe M, Van Grieken R, (1983)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA in nephrotoxicity studies”. Verbueken AH, Paulus GJ, Van de Vyver FL, Verpooten GA, Visser WJ, de Broe ME, Van Grieken RE, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA-study of aerosol samples collected in the Amazon basin”. Bruynseels F, Artaxo P, Storms H, Van Grieken R page 355 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
|
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis : characteristics and applications”. Van Grieken R, Verbueken A, Bruynseels F, Vandeputte D, Goossenaerts C, Leysen L, Otten P, Wouters L, (1987)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis (LAMMA) in nephrological investigations”. Verbueken AH, Van de Vyver FL, Paulus GJ, Visser WJ, Verpooten GA, de Broe ME, Van Grieken RE page 375 (1984).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) of parathyroid glands from dialysis patients”. Verbueken AH, Van de Vyver FL, Nouwen EJ, Roels F, de Broe ME, Van Grieken RE page 443 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
|
|
“Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone”. Verbueken AH, van de Vijver FL, Visser WJ, Van Grieken RE, de Broe ME, Stain technology 61, 287 (1986). http://doi.org/10.3109/10520298609109955
Abstract: Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.3109/10520298609109955
|
|
|
“Laser microprobe mass analysis of individual Antarctic aerosol particles”. Wouters L, Artaxo P, Van Grieken R, International journal of environmental analytical chemistry 38, 427 (1990). http://doi.org/10.1080/03067319008026946
Abstract: Individual Antarctic aerosol particles in the 0.54 μm aerodynamic diameter range were analyzed using laser microprobe mass analysis (LAMMA). As they were sampled near the ocean, the great majority consists of seasalt, transformed to various degrees in the atmosphere. Major alterations include the association of an excess sulfate and methane sulfonate with these particles. Sulfate-rich particles containing little or no chloride were found mostly in the smallest size fraction (0.51 μm), where they account for some 5% of all particles: they are most likely highly transformed seasalt. Aluminosilicates, on the other hand, only appear among the coarser particles: they represent 2% of the particulates in the 24 μm range. The remainder of the aerosol consists of organic, Fe-rich, K-rich and Zn-rich particles. The latter groups have very low abundances: always less than 1% of the population of the impactor stage(s) onto which they were collected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319008026946
|
|
|
“Laser microprobe mass analysis of individual North Sea aerosol particles”. Dierck I, Michaud D, Wouters L, Van Grieken R, Environmental science and technology 26, 802 (1992). http://doi.org/10.1021/ES00028A021
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00028A021
|
|
|
“Laser microprobe mass spectrometric identification of cyclosporine-induced intrarenal microliths in rat”. Verbueken AH, Van Grieken RE, Verpooten GA, de Broe ME, Wedeen RP, Biological mass spectrometry 21, 590 (1992). http://doi.org/10.1002/BMS.1200211111
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200211111
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Laser microprobe mass spectrometry of platinum in dog kidney after cisplatin adminstration”. Verbueken AH, Van Grieken RE, Paulus GJ, Verpooten GA, de Broe ME, Biomedical mass spectrometry 11, 159 (1984). http://doi.org/10.1002/BMS.1200110404
Abstract: By means of laser microprobe mass analysis (LAMMA) platinum was detected in the renal proximal tubular cells of a dog that had been intravenously adminstered the antitumor drug cisplatin (5 mg per kg body weight). No definite subcellular localization of the heavy metal was obtained. Sample prparation and analytical features are examined to increase spatial resolution of analysis while maintaining sufficient detection efficiency. The LAMMA method is destructive, but the amount and type of evaporated material can readily be determined when using LAMMA in combination with transmission electron microscopy. Instrumental optimization and standardization of mass signals is possible by using platinum-loaded, ion chelating resin beads embedded and sectioned with the tissue.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200110404
|
|
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
|
|
“Lead particles in an urban atmosphere : an individual particle approach”. Van Borman W, Wouters L, Van Grieken R, Adams F, The science of the total environment 90, 55 (1990). http://doi.org/10.1016/0048-9697(90)90185-W
Abstract: In air particulate matter, sampled at a suburban site near the city of Antwerp, Belgium, more than 1500 individual Pb-containing aerosol particles with projected diameters between 0.2 and 15 μm were analyzed by automated electron probe X-ray micro analysis (EPXMA) for 26 elements and morphological features. Laser microprobe mass analysis (LAMMA) was used to detect elements with Z < 11, particularly ammonium compounds. The Pb-containing particles were classified into five main classes: Pb-sulfates, Pb-halides, soil related Pb, Pb associated with medium atomic number elements and Pb associated with high atomic number elements. Each class was divided into several distinct particle types, of which the abundance (in number and mass %), the mean projected particle diameter, and the chemical composition were determined. Auto exhaust products are responsible for Pb-sulfates and Pb-halides, making up respectively 66.7 and 27.8% by mass of the Pb-containing particles. Ammonium sulfate coatings were found to be present on nearly all Pb particles. The observations were correlated with daily concentrations of Pb and Br, obtained by particle induced X-ray emission analysis (PIXE).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90185-W
|
|
|
“Light element analysis of individual microparticles using thin-window EPMA”. Osán J, Szalóki I, Ro C-U, Van Grieken R, Microchimica acta 132, 349 (2000). http://doi.org/10.1007/S006040050079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050079
|
|