“Tailoring the Ti-C nanoprecipitate population and microstructure of titanium stabilized austenitic steels”. Cautaerts N, Delville R, Stergar E, Schryvers D, Verwerft M, Journal of nuclear materials 507, 177 (2018). http://doi.org/10.1016/J.JNUCMAT.2018.04.041
Abstract: The present work reports on the microstructural evolution of a new heat of 24% cold worked austenitic DIN 1.4970 (15-15Ti) nuclear cladding steel subjected to ageing heat treatments of varying duration between 500 and 800 degrees C (by steps of 100 degrees C). The primary aim was studying the finely dispersed Ti-C nanoprecipitate population, which are thought to be beneficial for creep and swelling resistance during service. Their size distribution and number density were estimated through dark field imaging and bright field Moire imaging techniques in the transmission electron microscope. Nanoprecipitates formed at and above 600 degrees C, which is a lower temperature than previously reported. The observed nucleation, growth and coarsening behavior of the nanoprecipitates were consistent with simple diffusion arguments. The formation of nanoprecipitates coincided with significant dissociation of dislocations as evidenced by weak beam dark field imaging. Possible mechanisms, including Silcock's stacking fault growth model and Suzuki segregation, are discussed. Recrystallization observed after extended ageing at 800 degrees C caused the redissolution of nanoprecipitates. Large primary Ti(C,N) and (Ti,Mo)C precipitates that occur in the as-received material, and M23C6 precipitates that nucleate on grain boundaries at low temperatures were also characterized by a selective dissolution procedure involving filtration, X-ray diffraction and quantitative Rietveld refinement. The partitioning of key elements between the different phases was derived by combining these findings and was consistent with thermodynamic considerations and the processing history of the steel. (C) 2018 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.048
Times cited: 1
DOI: 10.1016/J.JNUCMAT.2018.04.041
|
“Applications of synchrotron X-ray nano-probes in the field of cultural heritage”. Cotte M, Genty-Vincent A, Janssens K, Susini J, Comptes rendus : physique 19, 575 (2018). http://doi.org/10.1016/J.CRHY.2018.07.002
Abstract: Synchrotron-based techniques are increasingly used in the field of cultural heritage, and this review focuses notably on the application of nano-beams to access high-spatial-resolution information on fragments sampled in historical or model artworks. Depending on the targeted information, various nano-analytical techniques can be applied, providing both identification and localization of the various components. More precisely, nano-X-ray fluorescence probes elements, nano-X-ray diffraction identify crystalline phases, and nano X-ray absorption spectroscopy is sensitive to speciation. Furthermore, computed tomography-based techniques can provide useful information about the morphology and in particular the porosity of materials. (C) 2018 Academie des sciences. Published by Elsevier Masson SAS.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.048
Times cited: 3
DOI: 10.1016/J.CRHY.2018.07.002
|
“Synergy between transmission electron microscopy and powder diffraction : application to modulated structures”. Batuk D, Batuk M, Abakumov AM, Hadermann J, Acta crystallographica: section B: structural science 71, 127 (2015). http://doi.org/10.1107/S2052520615005466
Abstract: The crystal structure solution of modulated compounds is often very challenging, even using the well established methodology of single-crystal X-ray crystallography. This task becomes even more difficult for materials that cannot be prepared in a single-crystal form, so that only polycrystalline powders are available. This paper illustrates that the combined application of transmission electron microscopy (TEM) and powder diffraction is a possible solution to the problem. Using examples of anion-deficient perovskites modulated by periodic crystallographic shear planes, it is demonstrated what kind of local structural information can be obtained using various TEM techniques and how this information can be implemented in the crystal structure refinement against the powder diffraction data. The following TEM methods are discussed: electron diffraction (selected area electron diffraction, precession electron diffraction), imaging (conventional high-resolution TEM imaging, high-angle annular dark-field and annular bright-field scanning transmission electron microscopy) and state-of-the-art spectroscopic techniques (atomic resolution mapping using energy-dispersive X-ray analysis and electron energy loss spectroscopy).
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.032
Times cited: 11
DOI: 10.1107/S2052520615005466
|
“Interstitial defects in the van der Waals gap of Bi2Se3”. Callaert C, Bercx M, Lamoen D, Hadermann J, Acta Crystallographica. Section B: Structural Science, Crystal Engineering and Materials (Online) 75, 717 (2019). http://doi.org/10.1107/S2052520619008357
Abstract: Bi<sub>2</sub>Se<sub>3</sub>is a thermoelectric material and a topological insulator. It is slightly conducting in its bulk due to the presence of defects and by controlling the defects different physical properties can be fine tuned. However, studies of the defects in this material are often contradicting or inconclusive. Here, the defect structure of Bi<sub>2</sub>Se<sub>3</sub>is studied with a combination of techniques: high-resolution scanning transmission electron microscopy (HR-STEM), high-resolution energy-dispersive X-ray (HR-EDX) spectroscopy, precession electron diffraction tomography (PEDT), X-ray diffraction (XRD) and first-principles calculations using density functional theory (DFT). Based on these results, not only the observed defects are discussed, but also the discrepancies in results or possibilities across the techniques. STEM and EDX revealed interstitial defects with mainly Bi character in an octahedral coordination in the van der Waals gap, independent of the applied sample preparation method (focused ion beam milling or cryo-crushing). The inherent character of these defects is supported by their observation in the structure refinement of the EDT data. Moreover, the occupancy probability of the defects determined by EDT is inversely proportional to their corresponding DFT calculated formation energies. STEM also showed the migration of some atoms across and along the van der Waals gap. The kinetic barriers calculated using DFT suggest that some paths are possible at room temperature, while others are most probably beam induced.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.032
DOI: 10.1107/S2052520619008357
|
“Needle twins and right-angled twins in minerals: comparison between experiment and theory”. Salje EKH, Buckley A, Van Tendeloo G, Ishibashi Y, Nord GL, The American mineralogist 83, 811 (1998)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.021
Times cited: 43
|
“Two generations of exsolution lamellae in pyroxene from Asuka 09545 : Clues to the thermal evolution of silicates in mesosiderite”. Pittarello L, Mckibbin S, Yamaguchi A, Ji G, Schryvers D, Debaille V, Claeys P, The American mineralogist 104, 1663 (2019). http://doi.org/10.2138/AM-2019-7001
Abstract: Mesosiderite meteorites consist of a mixture of crustal basaltic or gabbroic material and metal. Their formation process is still debated due to their unexpected combination of crust and core materials, possibly derived from the same planetesimal parent body, and lacking an intervening mantle component. Mesosiderites have experienced an extremely slow cooling rate from ca. 550 degrees C, as recorded in the metal (0.25-0.5 degrees C/Ma). Here we present a detailed investigation of exsolution features in pyroxene from the Antarctic mesosiderite Asuka (A) 09545. Geothermobarometry calculations, lattice parameters, lamellae orientation, and the presence of clinoenstatite as the host were used in an attempt to constrain the evolution of pyroxene from 1150 to 570 degrees C and the formation of two generations of exsolution lamellae. After pigeonite crystallization at ca. 1150 degrees C, the first exsolution process generated the thick augite lamellae along (100) in the temperature interval 1000-900 degrees C. By further cooling, a second order of exsolution lamellae formed within augite along (001), consisting of monoclinic low-Ca pyroxene, equilibrated in the temperature range 900-800 degrees C. The last process, occurring in the 600-500 degrees C temperature range, was likely the inversion of high to low pigeonite in the host crystal, lacking evidence for nucleation of orthopyroxene. The formation of two generations of exsolution lamellae, as well as of likely metastable pigeonite, suggest non-equilibrium conditions. Cooling was sufficiently slow to allow the formation of the lamellae, their preservation, and the transition from high to low pigeonite. In addition, the preservation of such fine-grained lamellae limits long-lasting, impact reheating to a peak temperature lower than 570 degrees C. These features, including the presence of monoclinic low-Ca pyroxene as the host, are reported in only a few mesosiderites. This suggests a possibly different origin and thermal history from most mesosiderites and that the crystallography (i.e., space group) of low-Ca pyroxene could be used as parameter to distinguish mesosiderite populations based on their cooling history.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.021
DOI: 10.2138/AM-2019-7001
|
“Aerosol synthesis of fullerene nanocrystals in controlled flow reactor conditions”. Joutsensaari J, Ahonen PP, Kauppinen EI, Brown DP, Lehtinen KEJ, Jokiniemi JK, Pauwels B, Van Tendeloo G, Journal of nanoparticle research 2, 53 (2000)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.02
Times cited: 5
|
“Assisted spray pyrolysis production and characterisation of ZnO nanoparticles with narrow size distribution”. Turner S, Tavernier SMF, Huyberechts G, Bals S, Batenburg KJ, Van Tendeloo G, Journal of nanoparticle research 12, 615 (2010). http://doi.org/10.1007/s11051-009-9630-1
Abstract: Nano-sized ZnO particles with a narrow size distribution and high crystallinity were prepared from aqueous solutions with high concentrations of Zn2+ containing salts and citric acid in a conventional spray pyrolysis setup. Structure, morphology and size of the produced material were compared to ZnO material produced by simple spray pyrolysis of zinc nitrates in the same experimental setup. Using transmission electron microscopy and electron tomography it has been shown that citric acid-assisted spray pyrolysed material is made up of micron sized secondary particles comprising a shell of lightly agglomerated, monocrystalline primary ZnO nanoparticles with sizes in the 2030 nm range, separable by a simple ultrasonic treatment step.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.02
Times cited: 27
DOI: 10.1007/s11051-009-9630-1
|
“The extracellular matrix protein 1: its molecular interaction and implication in tumor progression”. Sercu S, Zhang L, Merregaert J, Cancer investigation 26, 375 (2008). http://doi.org/10.1080/07357900701788148
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.007
Times cited: 41
DOI: 10.1080/07357900701788148
|
“The Split-operator technique for the study of spinorial wavepacket dynamics”. Chaves A, Farias GA, Peeters FM, Ferreira R, Communications in computational physics 17, 850 (2015). http://doi.org/10.4208/cicp.110914.281014a
Abstract: The split-operator technique for wave packet propagation in quantum systems is expanded here to the case of propagatingwave functions describing Schrodinger particles, namely, charge carriers in semiconductor nanostructures within the effective mass approximation, in the presence of Zeeman effect, as well as of Rashba and Dresselhaus spin-orbit interactions. We also demonstrate that simple modifications to the expanded technique allow us to calculate the time evolution of wave packets describing Dirac particles, which are relevant for the study of transport properties in graphene.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.004
Times cited: 24
DOI: 10.4208/cicp.110914.281014a
|
“Analysis of 3D elemental distribution in nanomaterials : towards higher throughput and dose efficiency”. Skorikov A, Batenburg KJ, Bals S, Journal of microscopy 289, 157 (2023). http://doi.org/10.1111/JMI.13167
Abstract: Many advanced nanomaterials rely on carefully designed morphology and elemental distribution to achieve their functionalities. Among the few experimental techniques that can directly visualise the 3D elemental distribution on the nanoscale are approaches based on electron tomography in combination with energy-dispersive X-ray spectroscopy (EDXS) and electron energy loss spectroscopy (EELS). Unfortunately, these highly informative methods are severely limited by the fundamentally low signal-to-noise ratio, which makes long experimental times and high electron irradiation doses necessary to obtain reliable 3D reconstructions. Addressing these limitations has been the major research question for the development of these techniques in recent years. This short review outlines the latest progress on the methods to reduce experimental time and electron irradiation dose requirements for 3D elemental distribution analysis and gives an outlook on the development of this field in the near future.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2
Times cited: 2
DOI: 10.1111/JMI.13167
|
“Comparison of mono- and polyatomic primary ions for the characterization of organic dye overlayers with static secondary ion mass spectrometry”. Lenaerts J, van Vaeck L, Gijbels R, Van Luppen J, Rapid communications in mass spectrometry 18, 257 (2004). http://doi.org/10.1002/rcm.1320
Abstract: Organic carbocyanine dye coatings have been analyzed by time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) using three types of primary ions: Ga+ operating at 25 keV, and Xe+ and SF5+ both operating at 9 keV. Secondary ion yields obtained with these three primary ions have been compared for coatings with different layer thickness, varying from (sub)-monolayer to multilayers, on different substrates (Si, Ag and AgBr cubic microcrystals). For (sub)-monolayers deposited on Ag, Xe+ and SF5+ primary ions generate similar precursor ion intensities, but with Ga+ slightly lower precursor ion intensities were obtained. Thick coatings on Ag as well as mono- and multilayers on Si produce the highest precursor and fragment ion intensities with the polyatomic primary ion. The yield difference between SF5+ and Xe+ can reach a factor of 6. In comparison with Ga+, yield enhancements by up to a factor of 180 are observed with SF5+. For the mass spectrometric analysis of dye layers on AgBr microcrystals, SF5+ again proves to be the primary ion of choice. Copyright (C) 2004 John Wiley Sons, Ltd.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 5
DOI: 10.1002/rcm.1320
|
“Matrix-enhanced secondary ion mass spectrometry: the influence of MALDI matrices on molecular ion yields of thin organic films”. Adriaensen L, Vangaever F, Lenaerts J, Gijbels R, Rapid communications in mass spectrometry 19, 1017 (2005). http://doi.org/10.1002/rcm.1881
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 24
DOI: 10.1002/rcm.1881
|
“Secondary ion formation of low molecular weight organic dyes in time-of-flight static secondary ion mass spectrometry”. Lenaerts J, van Vaeck L, Gijbels R, Rapid communications in mass spectrometry 17, 2115 (2003). http://doi.org/10.1002/rcm.1160
Abstract: Time-of-flight static secondary ion mass spectrometry (TOF-S-SIMS) was used to characterize thin layers of oxy- and thiocarbocyanine dyes on Ag and Si. Apart from adduct ions a variety of structural fragment ions were detected for which a fragmentation pattern is proposed. Peak assignments were confirmed by comparing spectra of dyes with very similar structures. All secondary ions were assigned with a mass accuracy better than 50 ppm. The intensity of molecular ions as well as fragment ions has been studied as a function of the type of organic dye, the substrate, the layer thickness and the type of primary ion. A large yield difference of two orders of magnitude was observed between the precursor ions of cationic carbocyanine dyes and the protonated molecules of the anionic dyes. Fragment ions, on the other hand, yielded similar intensities for both types of dye. As the dye layers deposited on an Ag substrate yielded higher secondary ion intensities than those deposited on a Si substrate, the Ag metal clearly acts as a promoting agent for secondary ion formation. The effect was more pronounced for precursor signals than for fragment ions. The promoting effect decreased as the deposited layer thickness of the organic dye layer was increased. Copyright (C) 2003 John Wiley Sons, Ltd.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.998
Times cited: 10
DOI: 10.1002/rcm.1160
|
“Large-volume injection combined with gas chromatography/isotope ratio mass spectrometry for the analysis of polycyclic aromatic hydrocarbons”. Buczyńska AJ, Geypens B, Van Grieken R, De Wael K, Rapid communications in mass spectrometry 28, 1 (2014). http://doi.org/10.1002/RCM.6769
Abstract: RATIONALE: Compound-specific stable isotope analyses of carbon require relatively large amounts of sample for reliable analyses. Commonly applied injections of 1 μL may thus be inefficient for samples with low concentrations of pollutants (e.g. air particulate matter) or when the amount of a sample is limited. METHODS: A Large-Volume Injection (LVI) method for carbon stable isotope ratio analysis of Polycyclic Aromatic Hydrocarbons (PAHs) was optimized in this study. Gas chromatography/combustion/isotope ratio mass spectrometry (GCCIRMS) and ion trap mass spectrometry (ITMS) were used for the determination of stable carbon isotope ratios and quantification of compounds, respectively. RESULTS: The optimized method resulted in very good reproducibility, even for the most volatile PAH, naphthalene, when a small amount of higher boiling co-solvent was used. No significant fractionation of isotope ratios could be seen and the recoveries of analytes were similar to or better than that of a splitless cold injection. CONCLUSIONS: Injection of 100 μL, instead of the commonly used 1 μL, increases the detection limit for PAHs significantly and/or simplifies the sample preparation step. Using our optimized method, stable carbon isotope ratios can be reliably measured in samples with concentrations of PAHs down to 0.050.1 ng μL1.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.998
Times cited: 5
DOI: 10.1002/RCM.6769
|
“Assessing the sustainability of community forest management : a case study from Iran”. Jafari A, Kaji HS, Azadi H, Gebrehiwot K, Aghamir F, Van Passel S, Forest Policy And Economics 96, 1 (2018). http://doi.org/10.1016/J.FORPOL.2018.08.001
Abstract: The development of sustainability criteria and indicators is necessary to assess the current management and to recognize appropriate management approaches towards sustainable forest management (SFM). The aim of this study is to assess the sustainability of current management in the Dopolan community forest and assess alternative management scenarios towards SFM. To this end, we applied multi criteria analysis which consists of three steps: a) developing a primary set of criteria and indicators (C&Is) on focus groups discussions, b) finalizing and weighing the set of C&Is, applying a pair wise comparison as well as ranking method, and c) assessing the current forest management regimes and alternative scenarios against a set of C&Is. As a result, 8 criteria and 40 indicators were selected. Our results indicated that to achieve SFM, the criteria including forest protection against natural and human factors, the establishment of appropriate legal and institutional requirements and socioeconomic functions of forests, are the most important criteria (weighted 14.60%, 14.28% and 13.96%, respectively). Assessing the current management regimes revealed that the criteria consisting of biodiversity conservation and local communities' awareness have the maximum distance to SFM (weighted 7.75% and 9.18%, respectively). Among the alternative forest management scenarios, the sixth scenario namely conservation and rehabilitation, local investment attraction in forest conservation and rehabilitation, enabling and capacity building of forest inhabitants were realized as the best scenarios (weighted 26.20%) to achieve SFM. A joint effort of the concerned government forestry officials and local people is needed to enhance the sustainability of all community based forestry models.
Keywords: A1 Journal article; Economics; Engineering Management (ENM)
Impact Factor: 1.982
Times cited: 4
DOI: 10.1016/J.FORPOL.2018.08.001
|
“Analytical electron microscopy of silver halide photographic systems”. Oleshko VP, Gijbels RH, Jacob WA, Micron 31, 55 (2000). http://doi.org/10.1016/S0968-4328(99)00055-4
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.98
Times cited: 8
DOI: 10.1016/S0968-4328(99)00055-4
|
“Do you believe that atoms stay in place when you observe them in HREM?”.van Dyck D, Lobato I, Chen F-R, Kisielowski C, Micron 68, 158 (2015). http://doi.org/10.1016/j.micron.2014.09.003
Abstract: Recent advancements in aberration-corrected electron microscopy allow for an evaluation of unexpectedly large atom displacements beyond a resolution limit of similar to 0.5 angstrom, which are found to be dose-rate dependent in high resolution images. In this paper we outline a consistent description of the electron scattering process, which explains these unexpected phenomena. Our approach links thermal diffuse scattering to electron beam-induced object excitation and relaxation processes, which strongly contribute to the image formation process. The effect can provide an explanation for the well-known contrast mismatch (“Stobbs factor”) between image calculations and experiments. (C) 2014 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 11
DOI: 10.1016/j.micron.2014.09.003
|
“The effect of probe inaccuracies on the quantitative model-based analysis of high angle annular dark field scanning transmission electron microscopy images”. Martinez GT, de Backer A, Rosenauer A, Verbeeck J, Van Aert S, Micron 63, 57 (2014). http://doi.org/10.1016/j.micron.2013.12.009
Abstract: Quantitative structural and chemical information can be obtained from high angle annular dark field scanning transmission electron microscopy (HAADF STEM) images when using statistical parameter estimation theory. In this approach, we assume an empirical parameterized imaging model for which the total scattered intensities of the atomic columns are estimated. These intensities can be related to the material structure or composition. Since the experimental probe profile is assumed to be known in the description of the imaging model, we will explore how the uncertainties in the probe profile affect the estimation of the total scattered intensities. Using multislice image simulations, we analyze this effect for Cs corrected and non-Cs corrected microscopes as a function of inaccuracies in cylindrically symmetric aberrations, such as defocus and spherical aberration of third and fifth order, and non-cylindrically symmetric aberrations, such as 2-fold and 3-fold astigmatism and coma.
Keywords: A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 25
DOI: 10.1016/j.micron.2013.12.009
|
“Electronic structure of Pd nanoparticles on carbon nanotubes”. Felten A, Ghijsen J, Pireaux J-J, Drube W, Johnson RL, Liang D, Hecq M, Van Tendeloo G, Bittencourt C, Micron 40, 74 (2009). http://doi.org/10.1016/j.micron.2008.01.013
Abstract: The effect of the oxygen plasma treatment on the electronic states of multi-wall carbon nanotubes (MWCNTs) is analyzed by X-ray photoemission measurements (XPS) and UPS, both using synchrotron radiation. It is found that the plasma treatment effectively grafts oxygen at the CNT-surface. Thereafter, the interaction between evaporated Pd and pristine or oxygen plasma-treated MWCNTs is investigated. Pd is found to nucleate at defective sites, whether initially present or introduced by oxygen plasma treatment. The plasma treatment induced a uniform dispersion of Pd clusters at the CNT-surface. The absence of additional features in the Pd 3d and C I s core levels spectra testifies that no Pd-C bond is formed. The shift of the Pd 3d core level towards high-binding energy for the smallest clusters is attributed to the Coulomb energy of the charged final state. (C) 2008 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 44
DOI: 10.1016/j.micron.2008.01.013
|
“Focused electron beam induced deposition as a tool to create electron vortices”. Béché, A, Winkler R, Plank H, Hofer F, Verbeeck J, Micron 80, 34 (2015). http://doi.org/10.1016/j.micron.2015.07.011
Abstract: Focused electron beam induced deposition (FEBID) is a microscopic technique that allows geometrically controlled material deposition with very high spatial resolution. This technique was used to create a spiral aperture capable of generating electron vortex beams in a transmission electron microscope (TEM). The vortex was then fully characterized using different TEM techniques, estimating the average orbital angular momentum to be approximately 0.8variant Planck's over 2pi per electron with almost 60% of the beam ending up in the l=1 state.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 21
DOI: 10.1016/j.micron.2015.07.011
|
“First-principles calculation of the electronic structure and energy loss near edge spectra of chiral carbon nanotubes”. Bertoni G, Calmels L, Micron 37, 486 (2006). http://doi.org/10.1016/j.micron.2005.10.011
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 12
DOI: 10.1016/j.micron.2005.10.011
|
“Functionalization of MWCNTs with atomic nitrogen”. Ruelle B, Felten A, Ghijsen J, Drube W, Johnson RL, Liang D, Erni R, Van Tendeloo G, Sophie P, Dubois P, Godfroid T, Hecq M, Bittencourt C;, Micron 40, 85 (2009). http://doi.org/10.1016/j.micron.2008.01.003
Abstract: In this study of the changes induced by exposing MWCNTs to a nitrogen plasma, it was found by HRTEM that the atomic nitrogen exposure does not significantly etch the surface of the carbon nanotube (CNT). Nevertheless, the atomic nitrogen generated by a microwave plasma effectively grafts amine, nitrile, amide, and oxime groups onto the CNT surface, as observed by XPS, altering the density of valence electronic states, as seen in UPS. (C) 2008 Elsevier Ltd. All fights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 24
DOI: 10.1016/j.micron.2008.01.003
|
“How to optimize the experimental design of quantitative atomic resolution TEM experiments?”.Van Aert S, den Dekker AJ, van Dyck D, Micron 35, 425 (2004). http://doi.org/10.1016/j.micron.2004.01.007
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 14
DOI: 10.1016/j.micron.2004.01.007
|
“Imaging from atomic structure to electronic structure”. Xu Q, Zandbergen HW, van Dyck D, Micron 43, 524 (2012). http://doi.org/10.1016/j.micron.2011.10.024
Abstract: This paper discusses the possibility of retrieving the electron distribution (with highlighted valence electron distribution information) of materials from recorded HREM images. This process can be achieved by solving two inverse problems: reconstruction of the exit wave and reconstruction of the electron distribution from exit waves. The first inverse problem can be solved using a focal series reconstruction method. We show that the second inverse problem can be solved by combining a series of exit waves recorded at different thickness conditions. This process is designed based on an improved understanding of the dynamical scattering process. It also explains the fundamental difficulty of obtaining the valence electron distribution information and the basis of our solution.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
DOI: 10.1016/j.micron.2011.10.024
|
“Model-based electron microscopy : from images toward precise numbers for unknown structure parameters”. Van Aert S, van den Broek W, Goos P, van Dyck D, Micron 43, 509 (2012). http://doi.org/10.1016/j.micron.2011.10.019
Abstract: Statistical parameter estimation theory is proposed as a method to quantify electron microscopy images. It aims at obtaining precise and accurate values for the unknown structure parameters including, for example, atomic column positions and types. In this theory, observations are purely considered as data planes, from which structure parameters have to be determined using a parametric model describing the images. The method enables us to measure positions of atomic columns with a precision of the order of a few picometers even though the resolution of the electron microscope is one or two orders of magnitude larger. Moreover, small differences in averaged atomic number, which cannot be distinguished visually, can be quantified using high-angle annular dark field scanning transmission electron microscopy images. Finally, it is shown how to optimize the experimental design so as to attain the highest precision. As an example, the optimization of the probe size for nanoparticle radius measurements is considered. It is also shown how to quantitatively balance signal-to-noise ratio and resolution by adjusting the probe size.
Keywords: A1 Journal article; Engineering Management (ENM); Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 1.98
Times cited: 7
DOI: 10.1016/j.micron.2011.10.019
|
“One-step synthesis of a suspended ultrathin graphene oxide film: Application in transmission electron microscopy”. Kirilenko DA, Dideykin AT, Aleksenskiy AE, Sitnikova AA, Konnikov SG, Vul' AY, Micron 68, 23 (2015). http://doi.org/10.1016/j.micron.2014.08.006
Abstract: Ultrathin graphene films find their use as advantageous support for nano- and biomaterials investigations. Thin film causes a very slight deterioration to measured signals, thus providing more details of the object's structure at nanoscale. The ultimate thinness of graphene works in the best way for this purpose. However, obtaining suspended thin film of a large-area, which is convenient for applications, is often a relatively complicated and time-consuming task. Here we present a one-step 1-min technique for synthesis of an extremely thin (about 1-2 nm) continuous film suspended over cells of a conventional copper grid (50-400 mu m mesh). This technique enables us to acquire a large-area film which is water-resistant, stable in organic solvents and can act as a support when studying nanoparticles or biomaterials. Moreover, the very mechanism of the film formation can be interesting from the point of view of other applications of ultrathin graphene oxide papers. (C) 2014 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 13
DOI: 10.1016/j.micron.2014.08.006
|
“Study of changes in composition and EELS ionization edges upon Ni4Ti3 precipitation in a NiTi alloy”. Yang Z, Schryvers D, Micron 37, 503 (2006). http://doi.org/10.1016/j.micron.2005.08.002
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 10
DOI: 10.1016/j.micron.2005.08.002
|
“Ultrastructure and composition of cell wall appositions in the roots of Asplenium (Polypodiales)”. Leroux O, Leroux F, Bagniewska-Zadworna, Knox JP, Claeys M, Bals S, Viane RLL, Micron 42, 863 (2011). http://doi.org/10.1016/j.micron.2011.06.002
Abstract: Cell wall appositions (CWAs), formed by the deposition of extra wall material at the contact site with microbial organisms, are an integral part of the response of plants to microbial challenge. Detailed histological studies of CWAs in fern roots do not exist. Using light and electron microscopy we examined the (ultra)structure of CWAs in the outer layers of roots of Asplenium species. All cell walls studded with CWAs were impregnated with yellow-brown pigments. CWAs had different shapes, ranging from warts to elongated branched structures, as observed with scanning and transmission electron microscopy. Ultrastructural study further showed that infecting fungi grow intramurally and that they are immobilized by CWAs when attempting to penetrate intracellularly. Immunolabelling experiments using monoclonal antibodies indicated pectic homogalacturonan, xyloglucan, mannan and cellulose in the CWAs, but tests for lignins and callose were negative. We conclude that these appositions are defense-related structures made of a non-lignified polysaccharide matrix on which phenolic compounds are deposited in order to create a barrier protecting the root against infections.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 20
DOI: 10.1016/j.micron.2011.06.002
|
“Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach”. Samaeeaghmiyoni V, Idrissi H, Groten J, Schwaiger R, Schryvers D, Micron 94, 66 (2017). http://doi.org/10.1016/j.micron.2016.12.005
Abstract: Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.98
Times cited: 11
DOI: 10.1016/j.micron.2016.12.005
|