“Healthy environment : indoor air quality of Brazilian elementary schools nearby petrochemical industry”. Godoi RHM, Godoi AFL, Gonçalves jr SJ, Paralovo SL, Borillo GC, Gregório Barbosa CG, Arantes MG, Rosário Filho NA, Grassi MT, Yamamoto CI, Potgieter-Vermaak S, Rotondo GG, De Wael K, Van Grieken R, The science of the total environment 463, 639 (2013). http://doi.org/10.1016/J.SCITOTENV.2013.06.043
Abstract: The mitigation of pollution released to the environment originating fromthe industrial sector has been the aimof all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 20092011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO2; SO2; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GCMS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of particles at extrathoracic, tracheobronchial and pulmonary levels.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.9
Times cited: 22
DOI: 10.1016/J.SCITOTENV.2013.06.043
|
“Urban air pollutants and their micro effects on medieval stained glass windows”. Kontozova-Deutsch V, Deutsch F, Godoi RHM, Van Grieken R, De Wael K, Microchemical journal 99, 508 (2011). http://doi.org/10.1016/J.MICROC.2011.07.003
Abstract: Levels of urban gaseous and particulate pollutants were investigated in the Cathedral of Cologne, Germany in the framework of the EU-project VIDRIO. The purpose of this study was to evaluate the influence of a protective double glazing system on the preservation of ancient stained glass windows by sampling at protected and unprotected windows (indoors, in the interspace and outdoor of the Cathedral). The interspace between the ancient stained glass window and the protective glazing is flushed in the Cathedral by indoor air, hence isolating the historic glass from the outdoor air and exposing it to indoor air on both sides of the glass panels. Concentrations of aggressive gaseous pollutants such as NO2, SO2, O3 and CO2 as well as elemental concentrations of bulk particles and relative abundances of single particles were surveyed at all sampling locations. Elemental concentrations in bulk particulate matter were found to be significantly lower inside the Cathedral in comparison to the outdoor air. This result is advantageous for the stained glass windows. Single particle analysis of the samples from Cologne showed also soil dust and organic particles as well as sulphates and nitrates, from which the latter two compounds are dangerous for the stained glass windows. On the base of the obtained results, it can be concluded that the protective glazing system in the Cathedral of Cologne can be considered as predominantly advantageous from both the gases' point of view (except for NO2-candles burning) and from the particles' point of view.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.034
Times cited: 6
DOI: 10.1016/J.MICROC.2011.07.003
|
“Cultural heritage research in “The Micro and Trace Analysis Center&rdquo, of the University of Antwerp”. Godoi RHM, Kontozova V, Godoi AFL, Bencs L, Spolnik Z, Janssens K, Van Grieken R, Coalition 7, 11 (2004)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Application of EPMA and XRF for the investigation of particulate pollutants in the field of cultural heritage”. Kontozova-Deutsch V, Deutsch F, Godoi RHM, Spolnik Z, Wei W, Van Grieken R, Microchimica acta 161, 465 (2008). http://doi.org/10.1007/S00604-007-0917-6
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-007-0917-6
|
“Application of low-pressure gas chromatography-io-trap mass spectrometry to the analysis of the eseential oil of Turnera diffusa (Ward.) Urb”. Godoi AFL, Vilegas W, Godoi RHM, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 127 (2004). http://doi.org/10.1016/J.CHROMA.2003.08.079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.08.079
|
“Assessment of aerosol particles within the Rubens' House Museum in Antwerp, Belgium”. Godoi RHM, Potgieter-Vermaak S, Godoi AFL, Stranger M, Van Grieken R, X-ray spectrometry 37, 298 (2008). http://doi.org/10.1002/XRS.1049
Abstract: The majority of researchers, conservators and curators recognise that atmospheric pollution is one of the major threats to works of art. In principle, all atmospheric particles, when deposited onto art objects can be considered harmful because of their potential in causing deterioration. Moreover, under certain conditions, particulate matter can induce and intensify surface damage, particularly because of its potential to serve as centre for moisture condensation and adsorbent of gaseous pollutants. To investigate the potential harm that these particles can cause, comprehensive characterisation of the particulate matter is necessary. Particulate matter was collected at the Rubens' House Museum in Antwerp, Belgium, where a unique exhibit of the paintings and living quarters of Peter Paul Rubens (1577-1640) are seen. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental and molecular compositions. They were analysed by electron probe micro-analysis, utilising facilities for low-Z element determination, and by energy-dispersive x-ray fluorescence, to investigate the elemental composition of individual particles and bulk samples, and by micro Raman spectrometry, to elucidate the molecular composition. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could contribute to the chemical reactions taking place on the surfaces of artefacts and which could potentially cause degradation of the objects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1049
|
“Assessment of atmospheric particles emitted from sugar cane burning in Southeast Brazil”. Godoi RHM, Godoi AFL, Andrade SJ, Santiago-Silva M, de Hoog J, Worobiec A, Van Grieken R, Journal od aerosol science , S749 (2003)
Keywords: A3 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Atmospheric nitrogen fluxes at the Belgian coast: 2004-2006”. Bencs L, Krata A, Horemans B, Buczyńska AJ, Dirtu AC, Godoi AFL, Godoi RHM, Potgieter-Vermaak S, Van Grieken R, Atmospheric environment : an international journal 43, 3786 (2009). http://doi.org/10.1016/J.ATMOSENV.2009.04.002
Abstract: Daily and seasonal variations in dry and wet atmospheric nitrogen fluxes have been studied during four campaigns between 2004 and 2006 at a coastal site of the Southern North Sea at De Haan (Belgium) located at coordinates of 51.1723° N and 3.0369° E. Concentrations of inorganic N-compounds were determined in the gaseous phase, size-segregated aerosol (coarse, medium, and fine), and rainwater samples. Dissolved organic nitrogen (DON) was quantified in rainwater. The daily variations in N-fluxes of compounds were evaluated with air-mass backward trajectories, classified into the main air-masses arriving at the sampling site (i.e., continental, North Sea, and Atlantic/UK/Channel). The three, non-episodic campaigns showed broadly consistent fluxes, but during the late summer campaign exceptionally high episodic N-deposition was observed. The average dry and wet fluxes for non-episodic campaigns amounted to 2.6 and 4.0 mg N m−2 d−1, respectively, whereas during the episodic late summer period these fluxes were as high as 5.2 and 6.2 mg N m−2 d−1, respectively. Non-episodic seasons/campaigns experienced average aerosol fluxes of 0.91.4 mg N m−2 d−1. Generally, the contribution of aerosol NH4+ was more significant in the medium and fine particulate fractions than that of aerosol NO3−, whereas the latter contributed more in the coarse fraction, especially in continental air-masses. During the dry mid-summer campaign, the DON contributed considerably (15%) to the total N-budget. Exceptionally high episodic aerosol-N inputs have been observed for the late summer campaign, with especially high deposition rates of 3.6 and 2.9 mg N m−2 d−1 for Atlantic/UK/Channel and North Sea-continental (mixed) air-masses, respectively. During this pollution episode, the flux of NH4+ was dominating in each aerosol fraction/air-mass, except for coarse continental aerosols. High deposition of gaseous-N was also observed in this campaign with an average total N-flux of 22.5-times higher than in other campaigns.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2009.04.002
|
“Biogeochemical study of a coccolithophore bloom in the northern Bay of Biscay (NE Atlantic Ocean) in June 2004”. Harlay J, Borges AV, van der Zee C, Delille B, Godoi RHM, Schiettecatte L-S, Roevros N, Aerts K, Lapernat P-E, Rebreanu L, Groom S, Daro M-H, Van Grieken R, Chou L, Progress in oceanography 86, 317 (2010). http://doi.org/10.1016/J.POCEAN.2010.04.029
Abstract: The present paper synthesizes data obtained during a multidisciplinary cruise carried out in June 2004 at the continental margin of the northern Bay of Biscay. The data-set allows to describe the different stages of a coccolithophore bloom dominated by Emiliania huxleyi. The cruise was carried out after the main spring phytoplankton bloom that started in mid-April and peaked in mid-May. Consequently, low phosphate (PO4 < 0.2 μM) and silicate (DSi < 2.0 μM) concentrations, low partial pressure of carbon dioxide (pCO2) and high calcite saturation degree in surface waters combined with thermal stratification, probably favoured the blooming of coccolithophores. During the period of the year our cruise was carried out, internal tides induce enhanced vertical mixing at the continental shelf break leading to the injection of inorganic nutrients to surface waters that probably trigger the bloom. The bloom developed as the water-column stratified and as the water mass was advected over the continental shelf, following the general residual circulation in the area. The most developed phase of the bloom was sampled in a remote sensed high reflectance (HR) patch over the continental shelf that was characterized by low chlorophyll-a (Chl-a) concentration in surface waters (<1.0 μg L−1), high particulate inorganic carbon (PIC) concentration (not, vert, similar8 μmol L−1) and coccolithophore abundance up to 57 × 106 cells L−1. Transparent exopolymer particles (TEP) concentrations ranged between 15 and 75 μg C L−1 and carbon content of TEP represented up to 26% of the particulate organic carbon (POC; maximum concentration of 15.5 μmol L−1 in the upper 40 m). Integrated primary production (PP) ranged between 210 and 680 mg C m−2 d−1 and integrated calcification (CAL) ranged between 14 and 140 mg C m−2 d−1, within the range of PP and CAL values previously reported during coccolithophore blooms in open and shelf waters of the North Atlantic Ocean. Bacterial protein production (BPP) measurements in surface waters (0.30.7 μg C L−1 h−1) were much higher than those reported during early phases of coccolithophore blooms in natural conditions, but similar to those during peak and declining coocolithophorid blooms reported in mesocosms. Total alkalinity anomalies with respect to conservative mixing (ΔTA) down to −49 μmol kg−1 are consistent with the occurrence of biogenic precipitation of calcite, while pCO2 remained 15107 μatm lower than atmospheric equilibrium (372 μatm). The correlation between ΔTA and pCO2 suggested that pCO2 increased in part due to calcification, but this increase was insufficient to overcome the background under-saturation of CO2. This is related to the biogeochemical history of the water masses due to net carbon fixation by the successive phytoplankton blooms in the area prior to the cruise, hence, the investigated area remained a sink for atmospheric CO2 despite calcification.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.POCEAN.2010.04.029
|
“Caracterização dos sistemas iônicos e particulado no reservatório”. Godoi RHM, Bittencourt AVL, Hirata PY, Jafelicci Junior M, dos Reis Neto JM, de Souza Sarkis JE, Zara LF, Van Grieken R page 170 (2011).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“A case study of high-temperature corrosion in rotary cement kilns”. Potgieter JH, Godoi RHM, Van Grieken R, Journal of the South African Institute of Mining and Metallurgy 104, 603 (2004)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Characterisation of soot emitted by domestic heating, aircraft and cars using diesel or biodiesel”. Smekens A, Godoi RHM, Berghmans P, Van Grieken R, Journal of atmospheric chemistry 52, 45 (2005). http://doi.org/10.1007/S10874-005-6903-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10874-005-6903-7
|
“Characterisation of sugar cane combustion particles in the Araraquara region, Southeast Brazil”. Godoi RHM, Godoi AFL, Worobiec A, Andrade SJ, de Hoog J, Santiago-Silva MR, Van Grieken R, Microchimica acta 145, 53 (2004). http://doi.org/10.1007/S00604-003-0126-X
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00604-003-0126-X
|
“Characterization of air pollutants observed in three European cathedrals: is the protective glazing really effective?”.Kontozova V, Godoi RHM, Spolnik Z, Worobiec A, Deutsch F, Van Grieken R, Rivista della Stazione sperimentale del vetro 3, 13 (2005)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Characterization of individual soot aggregates from different sources using image analysis”. Smekens A, Godoi RHM, Vervoort M, van Espen P, Potgieter-Vermaak SS, Van Grieken R, Journal of atmospheric chemistry 56, 211 (2007). http://doi.org/10.1007/S10874-006-9050-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1007/S10874-006-9050-X
|
“Characterization of the ionic and particulate systems in the reservoir”. Godoi RHM, Lima Bittencourt AV, Hirata PY, Jafelicci Junior M, dos Reis Neto JM, Van Grieken R page 143 (2014).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Composition and diurnal variability of the natural Amazonian aerosol”. Graham B, Guyon P, Maenhaut W, Taylor PE, Ebert M, Matthias-Maser S, Mayol-Bracero OL, Godoi RHM, Artaxo P, Meixner FX, Lima Moura MA, d'Almeida Rocha CHE, Van Grieken R, Glovsky MM, Flagan RC, Andreae MO, Journal of geophysical research 24, 5 (2003). http://doi.org/10.1029/2003JD004049
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/2003JD004049
|
“Conservation of stained glass windows with protective glazing : main results from the European VIDRIO research programme”. Bernardi A, Becherini F, Verità, M, Godoi RHM, Kontozova-Deutsch V, Van Grieken R, et al, Journal of cultural heritage 14, 527 (2013). http://doi.org/10.1016/J.CULHER.2012.11.009
Abstract: The methodology of protecting the European stained glass windows against environmental risk (e.g. meteorological factors, air pollution, microorganisms) by means of an external glazing is not new. In spite of many scientific studies carried out in the last 20 years, some questions were still up for discussion. The European VIDRIO (20022005) project gave an answer to these questions. The research carried out by the different project partners established a new multidisciplinary approach aimed at evaluating the efficiency of the protective glazing systems and their effects on stained glass windows conservation, and finally at assessing the most appropriate strategy to preserve stained glass windows. Scientific results showed that the so-called isothermal glazing (i.e. ventilation by the air coming from the inside of the building) protected efficiently the ancient stained glass window from environmental attack (i.e. rain, pollutants, condensation, thermal shocks) with very limited secondary effects. The scientific research highlighted that its efficiency was strongly related to the technical design of the protective system. In particular, the ventilation and the size of the interspace had to be carefully considered. The research developed within the VIDRIO project was turned into general recommendations to the owners and practitioners on the best practice for the stained glass windows future conservation.
Keywords: A1 Journal article; Art; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CULHER.2012.11.009
|
“Determination of BTEX by GCMS in air of offset printing plants: comparison between conventional and ecological inks”. Godoi AFL, Sawada EY, de Marchi MRR, Van Grieken R, Godoi RHM, Water, air, and soil pollution : focus 9, 163 (2009). http://doi.org/10.1007/S11267-009-9219-9
Abstract: The use of inks containing organic solvents by the offset printing process implies in the release of volatile organic compounds to the work environment. Many of these compounds such as benzene, toluene, ethylbenzene, and the xylene isomers (well known by the acronym BTEX) are extremely toxic. In this study, the BTEX concentrations were determined in two different printing plants that use distinct types of inks: the conventional and the so-called ecological, which is manufactured based on vegetal oil. Concentration ranges were 4384, 153,480, 2133, 5459, and 2236 μg m−3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively, for the conventional printing plant. At the ecological printing plant, concentration ranges were below limit of detection (<LD)-31, <LD-618, <LD-1,690, <LD-10,500, <LD-3,360 μg m−3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively. BTEX concentrations are lower at the ecological printing environment than in the conventional, where mineral oil-based inks are used. However, the worker who cleans the printing matrices is exposed to high concentrations of ethylbenzene and xylenes, due probably to the cleaning products composition (containing high amounts of BTEX). Although the BTEX concentrations found in both printing work environments were below the limits considered by the Brazilian Law for Activities and Unhealthy Operations (NR-15), the exposure to such vapors characterizes risk to the workers health for some of the evaluated samples, mainly the personal ones.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11267-009-9219-9
|
“Effects of air pollution and microclimate on stained glass windows: prliminary results in the Sainte Chapelle (Paris)”. Bernardi A, Becherini F, Kontozova V, Godoi RHM, Van Grieken R, Deutsch F page 133 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Elemental and single particle aerosol characterisation at a background station in Kazakhstan”. Hoornaert S, Godoi RHM, Van Grieken R, Journal of atmospheric chemistry 48, 301 (2004). http://doi.org/10.1023/B:JOCH.0000044432.74476.B0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/B:JOCH.0000044432.74476.B0
|
“Elemental composition of PM2.5 in Araraquara City (Southeast Brazil) during seasons with and without sugar cane burning”. Silva FS, Godoi RHM, Tauler R, de André, PA, Saldiva PHN, Van Grieken R, de Marchi MRR, Journal of environmental protection 6, 426 (2015). http://doi.org/10.4236/JEP.2015.65041
Abstract: Particulate matter with an aerodynamic diameter below 2.5 μm (PM2.5), present in polluted air, has been associated with a large spectrum of health impairments, mainly because of its deep deposition into the lungs. Araraquara City (Southeast Brazil) is surrounded by sugar-cane plantations, which are burned to facilitate the harvesting; this process causes environmental pollution due to the large amounts of soot that are released into the atmosphere. In this work, the elemental composition of PM2.5 was studied in two scenarios, namely in sugar-cane harvesting (HV) and in non-harvesting (NHV) seasons. The sampling strategy included one campaign in each season. PM2.5 was collected using a dichotomous sampler (10 L·min-1, 24 h) with PTFE filters. Information concerning the bulk elemental concentration was provided by energy-dispersive X-ray fluorescence. Enrichment factor analysis indicated that S, Cl, K, Cr, Ni, Cu, Zn, As, Cd and Pb were highly enriched relative to their crustal ratios (to Al). Principal component analysis was used to get some insight about the sources of the elements. Principal component 1 (PC1) explained 30.5% of data variance. The elements that had high loading (>0.7) were: S, Cr, As, and Pb; these are associated with combustion of fossil fuels. In principal component 2 (PC2), Cl, Cu, Zn, and Cd showed high loadings; these elements are associated with biomass burning. The Ni concentration found is three times larger than the threshold of risk for lung cancer, as recommended by the World Health Organization.
Keywords: A2 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.4236/JEP.2015.65041
|
“Fast chromatographic determination of polycyclic aromatic hydrocarbons in aerosol samples from sugar cane burning”. Godoi AFL, Ravindra K, Godoi RHM, Andrade SJ, Santiago-Silva M, Van Vaeck L, Van Grieken R, Journal of chromatography: A: bibliography section 1027, 49 (2004). http://doi.org/10.1016/J.CHROMA.2003.10.048
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CHROMA.2003.10.048
|
“Geochemical assessment of a subtropical reservoir : a case study in Curitiba, Southern Brazil”. Godoi RHM, Hirata PY, Bitterncourt AVL, Godoi AFL, Potgieter-Vermaak S, Gatto Rotondo G, Van Grieken R, et al, Clean : soil, air, water 40, 364 (2012). http://doi.org/10.1002/CLEN.201000610
Abstract: Suspended particles and dissolved substances in water provide reactive surfaces, influence metabolic activity and contribute to the net sediment deposition. It therefore plays an important part in the ecology and quality of the water mass. The water quality in reservoirs is crucial and it is naturally maintained by flushing and sedimentation, which continuously remove phosphorus from the water. In some reservoirs, however, these removal processes are countered by recycling of ions which could play a key role to start and/or maintain the eutrophic state. The combination of macro-, trace- and microanalysis techniques can be useful to trace pollution sources through a chemical fingerprint, whether be during an acute environmental disaster or a long-term release of pollutants. The water quality and total metal content of reservoir sediments were assessed in a reservoir, situated in the capital of the Paraná State, in the South-Eastern part of Brazil. The goal of this paper was to determine the metal presence in the sediment and metal and ionic speciation in the Green River reservoir water. Water and bed sediment samples, collected from various sites during 2008 and 2009, were investigated using XRF, ICP-OES, ICP-MS, XRD and zeta potential measurements. Based on the results, the heavy metal concentration and chemical composition of the suspended matter in the water samples, as well as the sediment's chemical composition will be discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/CLEN.201000610
|
“Health implications of atmospheric aerosols from asbestos-bearing road pavements traditionally used in Southern Brazil”. Godoi RHM, Goncalves SJ Jr, Sayama C, Polezer G, Reis Neto JM, Alfoldy B, Van Grieken R, Riedi CA, Yamamoto CI, Godoi AFL, Bencs L, Environmental Science and Pollution Research
T2 –, 1st International Caparica Conference on Pollutant Toxic Ions and, Molecules (PTIM), 2015, Caparica, PORTUGAL 23, 25180 (2016). http://doi.org/10.1007/S11356-016-7586-0
Abstract: Serpentine and amphibole asbestos occur naturally in certain geologic settings worldwide, most commonly in association with ultramafic rocks, along associated faults. Ultramafic rocks have been used in Pin County, Southern Brazil for decades for the purpose of road paving in rural and urban areas, but without the awareness of their adverse environmental and health impact. The aim of this study was the chemical characterization of aerosols re-suspended in two rural roads of Pin, paved with ultramafic rocks and to estimate the pulmonary deposition of asbestos aerosols. Bulk aerosol samples were analyzed by means of X-ray fluorescence spectrometry and X-ray diffraction analysis, in order to characterize elemental composition and crystallinity. Single-particle compositions of aerosols were analyzed by computer-controlled electron-probe microanalysis, indicating the presence of a few percentages of serpentine and amphibole. Given the chemical composition and size distribution of aerosol particles, the deposition efficiency of chrysotile, a sub-group of serpentine, in two principal segments of the human respiratory system was estimated using a lung deposition model. As an important finding, almost half of the inhaled particles were calculated to be deposited in the respiratory system. Asbestos depositions were significant (similar to 25 %) in the lower airways, even though the selected breathing conditions (rest situation, nose breathing) implied the lowest rate of respiratory deposition. Considering the fraction of inhalable suspended chrysotile near local roads, and the long-term exposure of humans to these aerosols, chrysotile may represent a hazard, regarding more frequent development of lung cancer in the population of the exposed region.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11356-016-7586-0
|
“Indoor air quality assessment of elementary schools in Curitiba, Brazil”. Godoi RHM, Avigo D, Campos VD, Tavares TM, de Marchi MRR, Van Grieken R, Godoi AFL, Water, air, and soil pollution : focus 9, 171 (2009). http://doi.org/10.1007/S11267-009-9220-3
Abstract: The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO2; SO2; O3; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatographyion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO2 varied between 9.5 and 23 µg m−3, whereas SO2 showed an interval from 0.1 to 4.8 µg m−3. Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 µg m−3 and 1.2 µg m−3, respectively.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S11267-009-9220-3
|
“Indoor air quality of a museum in a subtropical climate : the Oscar Niemeyer museum in Curitiba, Brazil”. Godoi RHM, Carneiro BHB, Paralovo SL, Campos VP, Tavares TM, Evangelista H, Van Grieken R, Godoi AFL, The science of the total environment 452, 314 (2013). http://doi.org/10.1016/J.SCITOTENV.2013.02.070
Abstract: The assessment of damage to indoor cultural heritage, in particular by pollutants, is nowadays a major and growing concern for curators and conservators. Nevertheless, although many museums have been widely investigated in Europe, the effects of particulate matter and gaseous pollutants in museums under tropical and subtropical climates and with different economic realities are still unclear. An important portion of the world's cultural heritage is currently in tropical countries where both human and financial resources for preserving museum collections are limited. Hence, our aim is to assess the damage that can be caused to the artwork by pollution in hot and humid environments, where air quality and microclimatic condition differences can cause deterioration. As a case study, particulate matter as well as gases were collected at the Oscar Niemeyer Museum (MON) in Curitiba, Brazil, where large modern and contemporary works of art are displayed. NO2, SO2, O3, Acetic Acid, Formic Acids and BTEX, in the ambient air, were sampled by means of passive diffusive sampling and their concentrations were determined by IC or GCMS. The particulate matter was collected in bulk form and analyzed with the use of energy dispersive X-ray fluorescence and aethalometer. The chemical compositions of individual particles were quantitatively elucidated, including low-Z components like C, N and O, as well as higher-Z elements, using automated electron probe microanalysis. The gaseous and particulate matter levels were then compared with the concentrations obtained for the same pollutants in other museums, located in places with different climates, and with some reference values provided by international cultural heritage conservation centers. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could contribute to the chemical reactions taking place on the surfaces of artifacts and which could potentially cause irreversible damage to the artworks.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SCITOTENV.2013.02.070
|
“Inferring episodic atmospheric iron fluxes in the Western South Atlantic”. Evangelista H, Maldonado J, dos Santos EA, Godoi RHM, Garcia CAE, Garcia VMT, Johnson E, da Cunha KD, Leite CB, Van Grieken R, van Meel K, Makarovska Y, Gaiero DM, Atmospheric environment : an international journal 44, 703 (2010). http://doi.org/10.1016/J.ATMOSENV.2009.11.018
Abstract: Iron (Fe) and other trace elements such as Zn, Mn, Ni and Cu are known as key-factors in marine biogeochemical cycles. It is believed that ocean primary productivity blooms in iron deficient regions can be triggered by iron in aeolian dust. Up to now, scarce aerosol elemental composition, based on measurements over sea at the Western South Atlantic (WSA), exist. An association between the Patagonian semi-desert dust/Fe and chlorophyll-a variability at the Argentinean continental shelf is essentially inferred from models. We present here experimental data of Fe enriched aerosols over the WSA between latitudes 22°S62°S, during 4 oceanographic campaigns between 2002 and 2005. These data allowed inferring the atmospheric Fe flux onto different latitudinal bands which varied from 30.4 to 1688 nmolFe m−2 day−1 (October 29thNovember 15th, 2003); 5.831586 nmolFe m−2 day−1 (February 15thMarch 6th, 2004) and 4.73586 nmolFe m−2 day−1(October 21stNovember 5th, 2005).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2009.11.018
|
“Influence of gaseous and particulate air pollutants on stained glass windows: case study in the Basilica Saint Urbain in Troyes, France”. Kontozova V, Godoi RHM, Spolnik Z, Worobiec A, Deutsch F, Van Grieken R, (2005)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Inhable particulate matter from lime industries: chemical composition and deposition in human respiratory tract”. Godoi RHM, Braga DM, Makarovska Y, Alfoldy B, Carvalho Filho MAS, Van Grieken R, Godoi AFL, Atmospheric environment : an international journal 42, 7027 (2008). http://doi.org/10.1016/J.ATMOSENV.2008.07.002
Abstract: Air pollution caused by the lime production industry has become a serious problem with potential effects to human health, especially in developing countries. Colombo is a city included in the Metropolitan Region of Curitiba (capital of Parana State) in South Brazil. In Colombo city, a correlation has been shown between the lime production and the number of persons who need respiratory treatment in a local hospital, indicating that the lime industry can cause deleterious health effects in the exposed workers and population. This research was conducted to deal firstly with the characterization of the size distribution and chemical compositions of particles emitted from lime manufacturing and subsequently to assess the deposition rate of inhaled dolomitic lime aerosol particles in the human respiratory tract. The elemental chemical composition and particle size of individual atmospheric particles was quantitatively elucidated, including low-Z components like C, N and 0, as well as higher-Z elements, using automated electron probe microanalysis. Information concerning the bulk composition is provided by energy-dispersive X-ray detection. The majority of the respirable particulate matter identified was composed of aluminosilicates, Ca-Mg oxides, carbon-rich particles, mixtures of organic particles and Ca-Mg carbonates, soot and biogenic particles. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the human respiratory system were calculated, revealing the deposition of CaO center dot MgO at extrathoracic, tracheobronchial and pulmonary levels. The results of this study offer evidence to the threat of the fine and coarse particles emitted from dolomite lime manufacturing, allowing policy-makers to better focus their mitigation strategies in an effective way, as well as to the dolomite producers for the purpose of designing and/or implementing improved emission controls.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2008.07.002
|