Home | << 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 >> |
Records | |||||
---|---|---|---|---|---|
Author | Croitoru, M.D.; van Dyck, D.; Van Aert, S.; Bals, S.; Verbeeck, J. | ||||
Title | An efficient way of including thermal diffuse scattering in simulation of scanning transmission electron microscopic images | Type | A1 Journal article | ||
Year | 2006 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 106 | Issue | 10 | Pages | 933-940 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Condensed Matter Theory (CMT); Vision lab | ||||
Abstract | We propose an improved image simulation procedure for atomic-resolution annular dark-field scanning transmission electron microscopy (STEM) based on the multislice formulation, which takes thermal diffuse scattering fully into account. The improvement with regard to the classical frozen phonon approach is realized by separating the lattice configuration statistics from the dynamical scattering so as to avoid repetitive calculations. As an example, the influence of phonon scattering on the image contrast is calculated and investigated. STEM image simulation of crystals can be applied with reasonable computing times to problems involving a large number of atoms and thick or large supercells. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000240397200006 | Publication Date | 2006-05-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 18 | Open Access | |
Notes | Fwo; Fwo-V | Approved | Most recent IF: 2.843; 2006 IF: 1.706 | ||
Call Number | UA @ lucian @ c:irua:87604UA @ admin @ c:irua:87604 | Serial | 876 | ||
Permanent link to this record | |||||
Author | Goris, B.; van den Broek, W.; Batenburg, K.J.; Heidari Mezerji, H.; Bals, S. | ||||
Title | Electron tomography based on a total variation minimization reconstruction technique | Type | A1 Journal article | ||
Year | 2012 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 113 | Issue | Pages | 120-130 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | The 3D reconstruction of a tilt series for electron tomography is mostly carried out using the weighted backprojection (WBP) algorithm or using one of the iterative algorithms such as the simultaneous iterative reconstruction technique (SIRT). However, it is known that these reconstruction algorithms cannot compensate for the missing wedge. Here, we apply a new reconstruction algorithm for electron tomography, which is based on compressive sensing. This is a field in image processing specialized in finding a sparse solution or a solution with a sparse gradient to a set of ill-posed linear equations. Therefore, it can be applied to electron tomography where the reconstructed objects often have a sparse gradient at the nanoscale. Using a combination of different simulated and experimental datasets, it is shown that missing wedge artefacts are reduced in the final reconstruction. Moreover, it seems that the reconstructed datasets have a higher fidelity and are easier to segment in comparison to reconstructions obtained by more conventional iterative algorithms. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300554400006 | Publication Date | 2011-11-14 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 171 | Open Access | |
Notes | Fwo | Approved | Most recent IF: 2.843; 2012 IF: 2.470 | ||
Call Number | UA @ lucian @ c:irua:93637 | Serial | 987 | ||
Permanent link to this record | |||||
Author | Bladt, E.; Pelt, D.M.; Bals, S.; Batenburg, K.J. | ||||
Title | Electron tomography based on highly limited data using a neural network reconstruction technique | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 158 | Issue | 158 | Pages | 81-88 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Gold nanoparticles are studied extensively due to their unique optical and catalytical properties. Their exact shape determines the properties and thereby the possible applications. Electron tomography is therefore often used to examine the three-dimensional (3D) shape of nanoparticles. However, since the acquisition of the experimental tilt series and the 3D reconstructions are very time consuming, it is difficult to obtain statistical results concerning the 3D shape of nanoparticles. Here, we propose a new approach for electron tomography that is based on artificial neural networks. The use of a new reconstruction approach enables us to reduce the number of projection images with a factor of 5 or more. The decrease in acquisition time of the tilt series and use of an efficient reconstruction algorithm allows us to examine a large amount of nanoparticles in order to retrieve statistical results concerning the 3D shape. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000361574800011 | Publication Date | 2015-07-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 25 | Open Access | OpenAccess |
Notes | 335078 COLOURATOM; FWO; COST Action MP1207; 312483 ESTEEM2; esteem2jra4; ECASSara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:126675 c:irua:126675 | Serial | 988 | ||
Permanent link to this record | |||||
Author | Goris, B.; Bals, S.; van den Broek, W.; Verbeeck, J.; Van Tendeloo, G. | ||||
Title | Exploring different inelastic projection mechanisms for electron tomography | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 8 | Pages | 1262-1267 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Several different projection mechanisms that all make use of inelastically scattered electrons are used for electron tomography. The advantages and the disadvantages of these methods are compared to HAADFSTEM tomography, which is considered as the standard electron tomography technique in materials science. The different inelastic setups used are energy filtered transmission electron microscopy (EFTEM), thickness mapping based on the log-ratio method and bulk plasmon mapping. We present a comparison that can be used to select the best inelastic signal for tomography, depending on different parameters such as the beam stability and nature of the sample. The appropriate signal will obviously also depend on the exact information which is requested. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000300461100039 | Publication Date | 2011-03-07 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 21 | Open Access | |
Notes | Fwo; Iap; Esteem 026019 | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:91260UA @ admin @ c:irua:91260 | Serial | 1151 | ||
Permanent link to this record | |||||
Author | Bals, S.; Kilaas, R.; Kisielowski, C. | ||||
Title | Nonlinear imaging using annular dark field TEM | Type | A1 Journal article | ||
Year | 2005 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 104 | Issue | 3/4 | Pages | 281-289 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Annular dark field TEM images exhibit a dominant mass-thickness contrast that can be quantified to extract single atom scattering cross sections. On top of this incoherent background, additional lattice fringes appear with a nonlinear information limit of 1.2 angstrom at 150 kV. The formation of these fringes is described by coherent nonlinear imaging theory and good agreement is found between experimental and simulated images. Calculations furthermore predict that the use of aberration corrected microscopes will improve the image quality dramatically. (c) 2005 Elsevier B.V. All rights reserved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000231297100012 | Publication Date | 2005-06-16 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | |
Notes | Approved | Most recent IF: 2.843; 2005 IF: 2.490 | |||
Call Number | UA @ lucian @ c:irua:64685 | Serial | 2352 | ||
Permanent link to this record | |||||
Author | Van Eyndhoven, G.; Kurttepeli, M.; van Oers, C.J.; Cool, P.; Bals, S.; Batenburg, K.J.; Sijbers, J. | ||||
Title | Pore REconstruction and Segmentation (PORES) method for improved porosity quantification of nanoporous materials | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 148 | Issue | 148 | Pages | 10-19 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab; Laboratory of adsorption and catalysis (LADCA) | ||||
Abstract | Electron tomography is currently a versatile tool to investigate the connection between the structure and properties of nanomaterials. However, a quantitative interpretation of electron tomography results is still far from straightforward. Especially accurate quantification of pore-space is hampered by artifacts introduced in all steps of the processing chain, i.e., acquisition, reconstruction, segmentation and quantification. Furthermore, most common approaches require subjective manual user input. In this paper, the PORES algorithm POre REconstruction and Segmentation is introduced; it is a tailor-made, integral approach, for the reconstruction, segmentation, and quantification of porous nanomaterials. The PORES processing chain starts by calculating a reconstruction with a nanoporous-specific reconstruction algorithm: the Simultaneous Update of Pore Pixels by iterative REconstruction and Simple Segmentation algorithm (SUPPRESS). It classifies the interior region to the pores during reconstruction, while reconstructing the remaining region by reducing the error with respect to the acquired electron microscopy data. The SUPPRESS reconstruction can be directly plugged into the remaining processing chain of the PORES algorithm, resulting in accurate individual pore quantification and full sample pore statistics. The proposed approach was extensively validated on both simulated and experimental data, indicating its ability to generate accurate statistics of nanoporous materials. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000345973000002 | Publication Date | 2014-08-23 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 7 | Open Access | OpenAccess |
Notes | Colouratom; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:119083 | Serial | 2672 | ||
Permanent link to this record | |||||
Author | Heidari Mezerji, H.; van den Broek, W.; Bals, S. | ||||
Title | A practical method to determine the effective resolution in incoherent experimental electron tomography | Type | A1 Journal article | ||
Year | 2011 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 111 | Issue | 5 | Pages | 330-336 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | It is not straightforward to determine resolution for a 3D reconstruction when performing an electron tomography experiment. Different contributions such as missing wedge and misalignment add up and often influence the final resolution in an anisotropic manner. The conventional resolution measures can not be used for all of the reconstruction techniques, especially for iterative techniques which are more commonly used for electron tomography in materials science. Here we define a quantitative resolution measure that determines the resolution in three orthogonal directions of the reconstruction. As an application we use this measure to determine the optimum number of simultaneous iterative reconstruction technique (SIRT) iterations to reconstruct the gold nanoparticles, based on a high angle annular dark field STEM (HAADF-STEM) tilt series. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000289396900005 | Publication Date | 2011-01-24 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 26 | Open Access | |
Notes | Esteem 026019; Fwo | Approved | Most recent IF: 2.843; 2011 IF: 2.471 | ||
Call Number | UA @ lucian @ c:irua:87606 | Serial | 2688 | ||
Permanent link to this record | |||||
Author | Chen, D.; Goris, B.; Bleichrodt, F.; Heidari Mezerji, H.; Bals, S.; Batenburg, K.J.; de With, G.; Friedrich, H. | ||||
Title | The properties of SIRT, TVM, and DART for 3D imaging of tubular domains in nanocomposite thin-films and sections | Type | A1 Journal article | ||
Year | 2014 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 147 | Issue | Pages | 137-148 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | In electron tomography, the fidelity of the 3D reconstruction strongly depends on the employed reconstruction algorithm. In this paper, the properties of SIRT, TVM and DART reconstructions are studied with respect to having only a limited number of electrons available for imaging and applying different angular sampling schemes. A well-defined realistic model is generated, which consists of tubular domains within a matrix having slab-geometry. Subsequently, the electron tomography workflow is simulated from calculated tilt-series over experimental effects to reconstruction. In comparison with the model, the fidelity of each reconstruction method is evaluated qualitatively and quantitatively based on global and local edge profiles and resolvable distance between particles. Results show that the performance of all reconstruction methods declines with the total electron dose. Overall, SIRT algorithm is the most stable method and insensitive to changes in angular sampling. TVM algorithm yields significantly sharper edges in the reconstruction, but the edge positions are strongly influenced by the tilt scheme and the tubular objects become thinned. The DART algorithm markedly suppresses the elongation artifacts along the beam direction and moreover segments the reconstruction which can be considered a significant advantage for quantification. Finally, no advantage of TVM and DART to deal better with fewer projections was observed. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000343157400015 | Publication Date | 2014-08-19 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 42 | Open Access | OpenAccess |
Notes | Fwo | Approved | Most recent IF: 2.843; 2014 IF: 2.436 | ||
Call Number | UA @ lucian @ c:irua:119073 | Serial | 2729 | ||
Permanent link to this record | |||||
Author | Van Aert, S.; Verbeeck, J.; Erni, R.; Bals, S.; Luysberg, M.; van Dyck, D.; Van Tendeloo, G. | ||||
Title | Quantitative atomic resolution mapping using high-angle annular dark field scanning transmission electron microscopy | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 10 | Pages | 1236-1244 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | A model-based method is proposed to relatively quantify the chemical composition of atomic columns using high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) images. The method is based on a quantification of the total intensity of the scattered electrons for the individual atomic columns using statistical parameter estimation theory. In order to apply this theory, a model is required describing the image contrast of the HAADF STEM images. Therefore, a simple, effective incoherent model has been assumed which takes the probe intensity profile into account. The scattered intensities can then be estimated by fitting this model to an experimental HAADF STEM image. These estimates are used as a performance measure to distinguish between different atomic column types and to identify the nature of unknown columns with good accuracy and precision using statistical hypothesis testing. The reliability of the method is supported by means of simulated HAADF STEM images as well as a combination of experimental images and electron energy-loss spectra. It is experimentally shown that statistically meaningful information on the composition of individual columns can be obtained even if the difference in averaged atomic number Z is only 3. Using this method, quantitative mapping at atomic resolution using HAADF STEM images only has become possible without the need of simultaneously recorded electron energy loss spectra. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000270015200004 | Publication Date | 2009-05-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 166 | Open Access | |
Notes | Fwo; Esteem 026019 | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | ||
Call Number | UA @ lucian @ c:irua:78585UA @ admin @ c:irua:78585 | Serial | 2748 | ||
Permanent link to this record | |||||
Author | Heidari, H.; van den Broek, W.; Bals, S. | ||||
Title | Quantitative electron tomography : the effect of the three-dimensional point spread function | Type | A1 Journal article | ||
Year | 2013 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 135 | Issue | Pages | 1-5 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | The intensity levels in a three-dimensional (3D) reconstruction, obtained by electron tomography, can be influenced by several experimental imperfections. Such artifacts will hamper a quantitative interpretation of the results. In this paper, we will correct for artificial intensity variations by determining the 3D point spread function (PSF) of a tomographic reconstruction based on high angle annular dark field scanning transmission electron microscopy. The large tails of the PSF cause an underestimation of the intensity of smaller particles, which in turn hampers an accurate radius estimate. Here, the error introduced by the PSF is quantified and corrected a posteriori. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000326941500001 | Publication Date | 2013-06-21 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 6 | Open Access | |
Notes | Esteem2; Sunflower; esteem2_jra4 | Approved | Most recent IF: 2.843; 2013 IF: 2.745 | ||
Call Number | UA @ lucian @ c:irua:111397 | Serial | 2756 | ||
Permanent link to this record | |||||
Author | Ke, X.; Bals, S.; Romo Negreira, A.; Hantschel, T.; Bender, H.; Van Tendeloo, G. | ||||
Title | TEM sample preparation by FIB for carbon nanotube interconnects | Type | A1 Journal article | ||
Year | 2009 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 109 | Issue | 11 | Pages | 1353-1359 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000270765800006 | Publication Date | 2009-07-11 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 21 | Open Access | |
Notes | Esteem 026019; Iap | Approved | Most recent IF: 2.843; 2009 IF: 2.067 | ||
Call Number | UA @ lucian @ c:irua:79074 | Serial | 3485 | ||
Permanent link to this record | |||||
Author | van Aarle, W.; Palenstijn, W.J.; De Beenhouwer, J.; Altantzis, T.; Bals, S.; Batenburg, K.J.; Sijbers, J. | ||||
Title | The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography | Type | A1 Journal article | ||
Year | 2015 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 157 | Issue | 157 | Pages | 35-47 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | We present the ASTRA Toolbox as an open platform for 3D image reconstruction in tomography. Most of the software tools that are currently used in electron tomography offer limited flexibility with respect to the geometrical parameters of the acquisition model and the algorithms used for reconstruction. The ASTRA Toolbox provides an extensive set of fast and flexible building blocks that can be used to develop advanced reconstruction algorithms, effectively removing these limitations. We demonstrate this flexibility, the resulting reconstruction quality, and the computational efficiency of this toolbox by a series of experiments, based on experimental dual-axis tilt series. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | English | Wos | 000361002400005 | Publication Date | 2015-05-06 |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 562 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from the iMinds ICONMetroCT project,the IWT SBO Tom Food project and from the Netherlands Organisation for Scientific Research (NWO),Project no. 639.072.005. Networking support was provided by the EXTREMA COST Action MP 1207. Sara Bals acknowledges financial support from the European Research Council (ERC Starting Grant #335078 COLOURATOMS).; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843; 2015 IF: 2.436 | ||
Call Number | c:irua:127834 | Serial | 3974 | ||
Permanent link to this record | |||||
Author | Zanaga, D.; Altantzis, T.; Sanctorum, J.; Freitag, B.; Bals, S. | ||||
Title | An alternative approach for ζ-factor measurement using pure element nanoparticles | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 164 | Issue | 164 | Pages | 11-16 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | It is very challenging to measure the chemical composition of hetero nanostructures in a reliable and quantitative manner. Here, we propose a novel and straightforward approach that can be used to quantify energy dispersive X-ray spectra acquired in a transmission electron microscope. Our method is based on a combination of electron tomography and the so-called ζ-factor technique. We will demonstrate the reliability of our approach as well as its applicability by investigating Au-Ag and Au-Pt hetero nanostructures. Given its simplicity, we expect that the method could become a new standard in the field of chemical characterization using electron microscopy. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000373526200002 | Publication Date | 2016-03-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 19 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from the European Research Council (ERC Starting Grant # 335078-COLOURATOMS) and the European Union under the FP7 (Integrated Infrastructure Initiative N. 312483 – ESTEEM2). The authors would also like to thank Luis M. Liz-Marzán, Ana Sánchez-Iglesias, Stefanos Mourdikoudis and Cristina Fernández-López for sample provision and useful discussions.; esteem2jra4; ECASSara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ | Serial | 4019 | ||
Permanent link to this record | |||||
Author | Goris, B.; Meledina, M.; Turner, S.; Zhong, Z.; Batenburg, K.J.; Bals, S. | ||||
Title | Three dimensional mapping of Fe dopants in ceria nanocrystals using direct spectroscopic electron tomography | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 171 | Issue | 171 | Pages | 55-62 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Electron tomography is a powerful technique for the 3D characterization of the morphology of nanostructures. Nevertheless, resolving the chemical composition of complex nanostructures in 3D remains challenging and the number of studies in which electron energy loss spectroscopy (EELS) is combined with tomography is limited. During the last decade, dedicated reconstruction algorithms have been developed for HAADF-STEM tomography using prior knowledge about the investigated sample. Here, we will use the prior knowledge that the experimental spectrum of each reconstructed voxel is a linear combination of a well-known set of references spectra in a so-called direct spectroscopic tomography technique. Based on a simulation experiment, it is shown that this technique provides superior results in comparison to conventional reconstruction methods for spectroscopic data, especially for spectrum images containing a relatively low signal to noise ratio. Next, this technique is used to investigate the spatial distribution of Fe dopants in Fe:Ceria nanoparticles in 3D. It is shown that the presence of the Fe2+ dopants is correlated with a reduction of the Ce atoms from Ce4+ towards Ce3+. In addition, it is demonstrated that most of the Fe dopants are located near the voids inside the nanoparticle. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000389106200007 | Publication Date | 2016-09-06 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 13 | Open Access | OpenAccess |
Notes | The work was supported by the Research Foundation Flanders (FWO Vlaanderen) by project funding (G038116N, 3G004613) and by a post-doctoral research grants to B.G. S.B. acknowledges funding from the European Research Council (Starting Grant no. COLOURATOMS 335078). K.J.B. acknowledges funding from The Netherlands Organization for Scientific Research (NWO) (program 639.072.005.). We would like to thank Dr. Hilde Poelman, Dr. Vladimir Galvita and Prof. Dr. Guy B. Marin for the synthesis of the investigated sample.; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843 | ||
Call Number | c:irua:135185 c:irua:135185 | Serial | 4123 | ||
Permanent link to this record | |||||
Author | Alania, M.; Altantzis, T.; De Backer, A.; Lobato, I.; Bals, S.; Van Aert, S. | ||||
Title | Depth sectioning combined with atom-counting in HAADF STEM to retrieve the 3D atomic structure | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 177 | Issue | 177 | Pages | 36-42 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | Aberration correction in scanning transmission electron microscopy (STEM) has greatly improved the lateral and depth resolution. When using depth sectioning, a technique during which a series of images is recorded at different defocus values, single impurity atoms can be visualised in three dimensions. In this paper, we investigate new possibilities emerging when combining depth sectioning and precise atom-counting in order to reconstruct nanosized particles in three dimensions. Although the depth resolution does not allow one to precisely locate each atom within an atomic column, it will be shown that the depth location of an atomic column as a whole can be measured precisely. In this manner, the morphology of a nanoparticle can be reconstructed in three dimensions. This will be demonstrated using simulations and experimental data of a gold nanorod. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000401219800006 | Publication Date | 2016-11-09 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 13 | Open Access | OpenAccess |
Notes | The authors acknowledge financial support from the European Union under the Seventh Framework Program under a contract for an Integrated Infrastructure Initiative. Reference No. 312483-ESTEEM2. S. Bals acknowledges funding from the European Research Council (Starting Grant No. COLOURATOMS 335078). The authors acknowledge financial support from the Research Foundation Flanders (FWO, Belgium) through project fundings (G.0374.13N, G.0369.15N and G.0368.15N) and a post-doctoral grant to A. De Backer and T. Altantzis. The authors are grateful to Professor Luis M. Liz-Marzán for providing the sample.; ECAS_Sara; (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:138015UA @ admin @ c:irua:138015 | Serial | 4316 | ||
Permanent link to this record | |||||
Author | Zanaga, D.; Altantzis, T.; Sanctorum, J.; Freitag, B.; Bals, S. | ||||
Title | An alternative approach for \zeta-factor measurement using pure element nanoparticles | Type | A1 Journal article | ||
Year | 2016 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 164 | Issue | Pages | 11-16 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | It is very challenging to measure the chemical composition of hetero nanostructures in a reliable and quantitative manner. Here, we propose a novel and straightforward approach that can be used to quantify energy dispersive X-ray spectra acquired in a transmission electron microscope. Our method is based on a combination of electron tomography and the so-called zeta-factor technique. We will demonstrate the reliability of our approach as well as its applicability by investigating Au-Ag and Au-Pt hetero nanostructures. Given its simplicity, we expect that the method could become a new standard in the field of chemical characterization using electron microscopy. (C) 2016 Elsevier B.V. All rights reserved. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000373526200002 | Publication Date | 2016-03-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 19 | Open Access | OpenAccess |
Notes | ; The authors acknowledge financial support from the European Research Council (ERC Starting Grant # 335078-COLOURATOMS) and the European Union under the FP7 (Integrated Infrastructure Initiative N. 312483 – ESTEEM2). ; ecas_Sara | Approved | Most recent IF: 2.843 | ||
Call Number | UA @ lucian @ c:irua:133259 | Serial | 4439 | ||
Permanent link to this record | |||||
Author | Zhong, Z.; Goris, B.; Schoenmakers, R.; Bals, S.; Batenburg, K.J. | ||||
Title | A bimodal tomographic reconstruction technique combining EDS-STEM and HAADF-STEM | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 174 | Issue | 174 | Pages | 35-45 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | A three-dimensional (3D) chemical characterization of nanomaterials can be obtained using tomography based on high angle annular dark field (HAADF) scanning transmission electron microscopy (STEM) or energy dispersive X-ray spectroscopy (EDS) STEM. These two complementary techniques have both advantages and disadvantages. The Z-contrast images have good image quality but lack robustness in the compositional analysis, while the elemental maps give more element-specific information, but at a low signal-to-noise ratio and a longer exposure time. Our aim is to combine these two types of complementary information in one single tomographic reconstruction process. Therefore, an imaging model is proposed combining both HAADF-STEM and EDS-STEM. Based on this model, the elemental distributions can be reconstructed using both types of information simultaneously during the reconstruction process. The performance of the new technique is evaluated using simulated data and real experimental data. The results demonstrate that combining two imaging modalities leads to tomographic reconstructions with suppressed noise and enhanced contrast. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000403342200005 | Publication Date | 2016-12-11 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 26 | Open Access | OpenAccess |
Notes | This research is supported by the Dutch Technology Foundation STW (http://www.stw.nl/), which is part of the Netherlands Organization for Scientific Research (NWO), and which is partly funded by the Ministry of Economic Affairs, Agriculture and Innovation under project number 13314. It is also supported by the Flemish research foundation (FWO Vlaanderen) by project funding (G038116N) and a postdoctoral research grant to B.G. Funding from the European Research Council (Starting Grant No. COLOURATOMS 335078) is acknowledged by S.B. The authors would like to thank Dr. Bernd Rieger and Dr. Richard Aveyard for useful discussions, and Prof. Dr. Luis M. Liz-Marzan for providing the investigated samples. We also acknowledge COST Action MP1207 for networking support. (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); saraecas; ECAS_Sara; | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:141719UA @ admin @ c:irua:141719 | Serial | 4484 | ||
Permanent link to this record | |||||
Author | Zhuge, X.; Jinnai, H.; Dunin-Borkowski, R.E.; Migunov, V.; Bals, S.; Cool, P.; Bons, A.-J.; Batenburg, K.J. | ||||
Title | Automated discrete electron tomography – Towards routine high-fidelity reconstruction of nanomaterials | Type | A1 Journal article | ||
Year | 2017 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 175 | Issue | 175 | Pages | 87-96 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA) | ||||
Abstract | Electron tomography is an essential imaging technique for the investigation of morphology and 3D structure of nanomaterials. This method, however, suffers from well-known missing wedge artifacts due to a restricted tilt range, which limits the objectiveness, repeatability and efficiency of quantitative structural analysis. Discrete tomography represents one of the promising reconstruction techniques for materials science, potentially capable of delivering higher fidelity reconstructions by exploiting the prior knowledge of the limited number of material compositions in a specimen. However, the application of discrete tomography to practical datasets remains a difficult task due to the underlying challenging mathematical problem. In practice, it is often hard to obtain consistent reconstructions from experimental datasets. In addition, numerous parameters need to be tuned manually, which can lead to bias and non-repeatability. In this paper, we present the application of a new iterative reconstruction technique, named TVR-DART, for discrete electron tomography. The technique is capable of consistently delivering reconstructions with significantly reduced missing wedge artifacts for a variety of challenging data and imaging conditions, and can automatically estimate its key parameters. We describe the principles of the technique and apply it to datasets from three different types of samples acquired under diverse imaging modes. By further reducing the available tilt range and number of projections, we show that the proposed technique can still produce consistent reconstructions with minimized missing wedge artifacts. This new development promises to provide the electron microscopy community with an easy-to-use and robust tool for high-fidelity 3D characterization of nanomaterials. |
||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000403342500008 | Publication Date | 2017-01-24 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 22 | Open Access | OpenAccess |
Notes | This work has been supported in part by the Stichting voor de Technische Wetenschappen (STW) through a personal grant (Veni,13610), and was in part by ExxonMobil Chemical Europe Inc. The authors further acknowledge financial support from the University of Antwerp through BOF GOA funding. S.B. acknowledges financial support from the European Research Council (ERC Starting Grant #335078-COLOURATOMS). R.D.B. is grateful for funding from the European Research Council under the European Union's Seventh Framework Programme (FP7/2007–2013)/ ERC grant agreement number 320832. Thomas Altantzis is gratefully acknowledged for acquiring the Anatase nanosheets dataset. (ROMEO:green; preprint:; postprint:can ; pdfversion:cannot); saraecas; ECAS_Sara; | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @ c:irua:141218UA @ admin @ c:irua:141218 | Serial | 4485 | ||
Permanent link to this record | |||||
Author | Zhong, Z.; Aveyard, R.; Rieger, B.; Bals, S.; Palenstijn, W.J.; Batenburg, K.J. | ||||
Title | Automatic correction of nonlinear damping effects in HAADF-STEM tomography for nanomaterials of discrete compositions | Type | A1 Journal article | ||
Year | 2018 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 184 | Issue | 184 | Pages | 57-65 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | <script type='text/javascript'>document.write(unpmarked('HAADF-STEM tomography is a common technique for characterizing the three-dimensional morphology of nanomaterials. In conventional tomographic reconstruction algorithms, the image intensity is assumed to be a linear projection of a physical property of the specimen. However, this assumption of linearity is not completely valid due to the nonlinear damping of signal intensities. The nonlinear damping effects increase w.r.t the specimen thickness and lead to so-called \u0022cupping artifacts\u0022, due to a mismatch with the linear model used in the reconstruction algorithm. Moreover, nonlinear damping effects can strongly limit the applicability of advanced reconstruction approaches such as Total Variation Minimization and discrete tomography. In this paper, we propose an algorithm for automatically correcting the nonlinear effects and the subsequent cupping artifacts. It is applicable to samples in which chemical compositions can be segmented based on image gray levels. The correction is realized by iteratively estimating the nonlinear relationship between projection intensity and sample thickness, based on which the projections are linearized. The correction and reconstruction algorithms are tested on simulated and experimental data. (C) 2017 Elsevier B.V. All rights reserved.')); | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Amsterdam | Editor | ||
Language | Wos | 000417779800008 | Publication Date | 2017-10-31 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 8 | Open Access | OpenAccess |
Notes | ; This research is supported by the Dutch Technology Foundation STW (http:// www.stw.nl/), which is part of the Netherlands Organization for Scientific Research (NWO), and which is partly funded by the Ministry of Economic Affairs, Agriculture and Innovation under project number 13314. Funding from the European Research Council (Starting grant no. COLOURATOMS 335078) is acknowledged by S. Bals. The authors would like to thank Dr. Thomas Altantzis and Dr. Bart Goris for providing the experimental data, and Prof. Dr. Luis M. Liz-Marzan for providing the investigated samples. ; ecas_sara | Approved | Most recent IF: 2.843 | ||
Call Number | UA @ lucian @ c:irua:148501UA @ admin @ c:irua:148501 | Serial | 4867 | ||
Permanent link to this record | |||||
Author | Vanrompay, H.; Skorikov, A.; Bladt, E.; Béché, A.; Freitag, B.; Verbeeck, J.; Bals, S. | ||||
Title | Fast versus conventional HAADF-STEM tomography of nanoparticles: advantages and challenges | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113191 | |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | HAADF-STEM tomography is a widely used experimental technique for analyzing nanometer-scale crystalline structures of a large variety of materials in three dimensions. Unfortunately, the acquisition of conventional HAADF-STEM tilt series can easily take up one hour or more, depending on the complexity of the experiment. It is therefore far from straightforward to investigate samples that do not withstand long acquisition or to acquire large amounts of tilt series during a single TEM experiment. The latter would lead to the ability to obtain statistically meaningful 3D data, or to perform in situ 3D characterizations with a much shorter time resolution. Various HAADF-STEM acquisition strategies have been proposed to accelerate the tomographic acquisition and reduce the required electron dose. These methods include tilting the holder continuously while acquiring a projection “movie” and a hybrid, incremental, methodology which combines the benefits of the conventional and continuous technique. However, until now an experimental evaluation has been lacking. In this paper, the different acquisition strategies will be experimentally compared in terms of speed, resolution and electron dose. This evaluation will be performed based on experimental tilt series acquired for various metallic nanoparticles with different shapes and sizes. We discuss the data processing involved with the fast HAADF-STEM tilt series and provide a general guideline when which acquisition strategy should be preferentially used. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600003 | Publication Date | 2020-12-08 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 15 | Open Access | OpenAccess |
Notes | We acknowledge Prof. Luis M. Liz-Marzán and co-workers of the Bionanoplasmonics Laboratory, CIC biomaGUNE, Spain for providing the Au@Ag nanoparticles, Prof. Sara. E. Skrabalak and co-workers of Indiana University, United States for the provision of the Au octopods and Prof. Teri W. Odom of Northwestern University, United States for the provision of the Au nanostars. H.V. acknowledges financial support by the Research Foundation Flanders (FWO grant 1S32617N). S.B acknowledges financial support by the Research Foundation Flanders (FWO grant G.0381.16N). This project received funding as well from the European Union’s Horizon 2020 research and innovation program under grant agreement No 731019 (EUSMI) and No 815128 (REALNANO). The authors acknowledge the entire EMAT technical staff for their support.; sygma | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174551 | Serial | 6660 | ||
Permanent link to this record | |||||
Author | Li, C.; Tardajos, A.P.; Wang, D.; Choukroun, D.; Van Daele, K.; Breugelmans, T.; Bals, S. | ||||
Title | A simple method to clean ligand contamination on TEM grids | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 221 | Issue | Pages | 113195 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT) | ||||
Abstract | Colloidal nanoparticles (NPs) including nanowires and nanosheets made by chemical methods involve many organic ligands. When the structure of NPs is investigated via transmission electron microscopy (TEM), the organic ligands act as a source for e-beam induced deposition and this causes substantial build-up of carbon layers in the investigated areas, which is typically referred to as “contamination” in the eld of electron mi- croscopy. This contamination is often more severe for scanning TEM, a technique that is based on a focused electron beam and hence higher electron dose rate. In this paper, we report a simple and effective method to clean drop-cast TEM grids that contain NPs with ligands. Using a combination of activated carbon and ethanol, this method effectively reduces the amount of ligands on TEM grids, and therefore greatly improves the quality of electron microscopy images and subsequent analytical measurements. This ef cient and facile method can be helpful during electron microscopy investigation of different kinds of nanomaterials that suffer from ligand- induced contamination. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000612539600002 | Publication Date | 0000-00-00 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 10 | Open Access | OpenAccess |
Notes | This research was funded by the University Antwerp GOA project (ID 33928). DW acknowledges an Individual Fellowship funded by the Marie Sklodowska-Curie Actions (MSCA) in Horizon 2020 program (grant 894254 SuprAtom). | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:174947 | Serial | 6666 | ||
Permanent link to this record | |||||
Author | Koo, J.; Dahl, A.B.; Bærentzen, J.A.; Chen, Q.; Bals, S.; Dahl, V.A. | ||||
Title | Shape from projections via differentiable forward projector for computed tomography | Type | A1 Journal article | ||
Year | 2021 | Publication | Ultramicroscopy | Abbreviated Journal | Ultramicroscopy |
Volume | 224 | Issue | Pages | 113239 | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | In computed tomography, the reconstruction is typically obtained on a voxel grid. In this work, however, we propose a mesh-based reconstruction method. For tomographic problems, 3D meshes have mostly been studied to simulate data acquisition, but not for reconstruction, for which a 3D mesh means the inverse process of estimating shapes from projections. In this paper, we propose a differentiable forward model for 3D meshes that bridge the gap between the forward model for 3D surfaces and optimization. We view the forward projection as a rendering process, and make it differentiable by extending recent work in differentiable rendering. We use the proposed forward model to reconstruct 3D shapes directly from projections. Experimental results for single-object problems show that the proposed method outperforms traditional voxel-based methods on noisy simulated data. We also apply the proposed method on electron tomography images of nanoparticles to demonstrate the applicability of the method on real data. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000744576800008 | Publication Date | 2021-03-11 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0304-3991 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.843 | Times cited | 3 | Open Access | OpenAccess |
Notes | EU Horizon 2020 MSCA Innovative Training Network MUMMERING Grant Number 765604. | Approved | Most recent IF: 2.843 | ||
Call Number | EMAT @ emat @c:irua:183267 | Serial | 6825 | ||
Permanent link to this record | |||||
Author | Garzia Trulli, M.; Claes, N.; Pype, J.; Bals, S.; Baert, K.; Terryn, H.; Sardella, E.; Favia, P.; Vanhulsel, A. | ||||
Title | Deposition of aminosilane coatings on porous Al2O3microspheres by means of dielectric barrier discharges | Type | A1 Journal article | ||
Year | 2017 | Publication | Plasma processes and polymers | Abbreviated Journal | Plasma Process Polym |
Volume | 14 | Issue | 14 | Pages | 1600211 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA) | ||||
Abstract | Advances in the synthesis of porous microspheres and in their functionalization are increasing the interest in applications of alumina. This paper deals with coatings plasma deposited from 3-aminopropyltriethoxysilane by means of dielectric barrier discharges on alumina porous microspheres, shaped by a vibrational droplet coagulation technique. Aims of the work are the functionalization of the particles with active amino groups, as well as the evaluation of their surface coverage and of the penetration of the coatings into their pores. A multi-diagnostic approach was used for the chemical/morphological characterization of the particles. It was found that 5 min exposure to plasma discharges promotes the deposition of homogeneous coatings onto the microspheres and within their pores, down to 1 μm. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000410773200003 | Publication Date | 2017-01-05 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1612-8850 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.846 | Times cited | 8 | Open Access | OpenAccess |
Notes | The technical assistance of the VITO staff (Materials Dpt.) is gratefully acknowledged, especially D. Havermans, E. Van Hoof, R. Kemps (SEM-EDX), and A. De Wilde (Hg Porosimetry). Drs. S. Mullens and G. Scheltjens are kindly acknowledged for constructive discussions. Strategic Initiative Materials in Flanders (SIM) is gratefully acknowledged for its financial support. This research was carried out in the framework of the SIM-TRAP program (Tools for rational processing of nano-particles: controlling and tailoring nanoparticle based or nanomodified particle based materials). N. Claes and S. Bals acknowledge financial support from European Research Council (ERC Starting Grant #335078-COLOURATOM). (ROMEO:white; preprint:; postprint:restricted ; pdfversion:cannot); saraecas; ECAS_Sara; | Approved | Most recent IF: 2.846 | ||
Call Number | EMAT @ emat @ c:irua:139511UA @ admin @ c:irua:139511 | Serial | 4342 | ||
Permanent link to this record | |||||
Author | Molina, L.; Tan, H.; Biermans, E.; Batenburg, K.J.; Verbeeck, J.; Bals, S.; Van Tendeloo, G. | ||||
Title | Barrier efficiency of sponge-like La2Zr2O7 buffer layers for YBCO-coated conductors | Type | A1 Journal article | ||
Year | 2011 | Publication | Superconductor science and technology | Abbreviated Journal | Supercond Sci Tech |
Volume | 24 | Issue | 6 | Pages | 065019-065019,8 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab | ||||
Abstract | Solution derived La2Zr2O7 films have drawn much attention for potential applications as thermal barriers or low-cost buffer layers for coated conductor technology. Annealing and coating parameters strongly affect the microstructure of La2Zr2O7, but different film processing methods can yield similar microstructural features such as nanovoids and nanometer-sized La2Zr2O7 grains. Nanoporosity is a typical feature found in such films and the implications for the functionality of the films are investigated by a combination of scanning transmission electron microscopy (STEM), electron energy-loss spectroscopy (EELS) and quantitative electron tomography. Chemical solution based La2Zr2O7 films deposited on flexible Ni5 at.%W substrates with a {100}lang001rang biaxial texture were prepared for an in-depth characterization. A sponge-like structure composed of nanometer-sized voids is revealed by high-angle annular dark-field scanning transmission electron microscopy in combination with electron tomography. A three-dimensional quantification of nanovoids in the La2Zr2O7 film is obtained on a local scale. Mostly non-interconnected highly faceted nanovoids compromise more than one-fifth of the investigated sample volume. The diffusion barrier efficiency of a 170 nm thick La2Zr2O7 film is investigated by STEM-EELS, yielding a 1.8 ± 0.2 nm oxide layer beyond which no significant nickel diffusion can be detected and intermixing is observed. This is of particular significance for the functionality of YBa2Cu3O7 − δ coated conductor architectures based on solution derived La2Zr2O7 films as diffusion barriers. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Bristol | Editor | ||
Language | Wos | 000290472900021 | Publication Date | 2011-04-20 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0953-2048;1361-6668; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.878 | Times cited | 31 | Open Access | |
Notes | Esteem 026019; Fwo | Approved | Most recent IF: 2.878; 2011 IF: 2.662 | ||
Call Number | UA @ lucian @ c:irua:88639UA @ admin @ c:irua:88639 | Serial | 221 | ||
Permanent link to this record | |||||
Author | Wang, H.; Picot, T.; Houben, K.; Moorkens, T.; Grigg, J.; Van Haesendonck, C.; Biermans, E.; Bals, S.; Brown, S.A.; Vantomme, A.; Temst, K.; Van Bael, M.J.; | ||||
Title | The superconducting proximity effect in epitaxial Al/Pb nanocomposites | Type | A1 Journal article | ||
Year | 2014 | Publication | Superconductor science and technology | Abbreviated Journal | Supercond Sci Tech |
Volume | 27 | Issue | 1 | Pages | 015008-8 |
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT) | ||||
Abstract | We have investigated the superconducting properties of Pb nanoparticles with a diameter ranging from 8 to 20 nm, synthesized by Pb+ ion implantation in a crystalline Al matrix. A detailed structural characterization of the nanocomposites reveals the highly epitaxial relation between the Al crystalline matrix and the Pb nanoparticles. The Al/Pb nanocomposites display a single superconducting transition, with the critical temperature T-c increasing with the Pb content. The dependence of T-c on the Pb/Al volume ratio was compared with theoretical models of the superconducting proximity effect based on the bulk properties of Al and Pb. A very good correspondence with the strong-coupling proximity effect model was found, with an electron-phonon coupling constant in the Pb nanoparticles slightly reduced compared to bulk Pb. Our result differs from other studies on Pb nanoparticle based proximity systems where weak-coupling models were found to better describe the T-c dependence. We infer that the high interface quality resulting from the ion implantation synthesis method is a determining factor for the superconducting properties. Critical field and critical current measurements support the high quality of the nanocomposite superconducting films. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Bristol | Editor | ||
Language | Wos | 000328275000010 | Publication Date | 2013-11-28 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0953-2048;1361-6668; | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.878 | Times cited | 2 | Open Access | Not_Open_Access |
Notes | ; This work was supported by the Research Foundation-Flanders (FWO), the KU Leuven BOF Concerted Research Action programs (GOA/09/006, the KU Leuven BOF CREA/12/015 project, and GOA/14/007) and the EU FP7 program SPIRIT (227012). TP and KH are postdoctoral research fellow and doctoral fellow of the FWO. ; | Approved | Most recent IF: 2.878; 2014 IF: 2.325 | ||
Call Number | UA @ lucian @ c:irua:112833 | Serial | 3599 | ||
Permanent link to this record | |||||
Author | Pacquets, L.; Irtem, E.; Neukermans, S.; Daems, N.; Bals, S.; Breugelmans, T. | ||||
Title | Size-controlled electrodeposition of Cu nanoparticles on gas diffusion electrodes in methanesulfonic acid solution | Type | A1 Journal article | ||
Year | 2020 | Publication | Journal Of Applied Electrochemistry | Abbreviated Journal | J Appl Electrochem |
Volume | 51 | Issue | 2 | Pages | |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Applied Electrochemistry & Catalysis (ELCAT) | ||||
Abstract | In this paper electrodeposition is used to obtain Cu nanoparticles, as it allows good control over particle size and distribution. These Cu particles were deposited onto a gas diffusion electrode which increased the resulting surface area. Prior to deposition, the surface was pre-treated with NaOH, HNO3, MQ and TX100 to investigate the influence on the electrodeposition of Cu on the gas diffusion electrode (GDE). When using HNO3, the smallest particles with the most homogeneous distribution and high particle roughness were obtained. Once the optimal substrate was determined, we further demonstrated that by altering the electrodeposition parameters, the particle size and density could be tuned. On the one hand, increasing the nucleation potential led to a higher particle density resulting in smaller particles because of an increased competition between particles. Finally, the Cu particle size increased when applying a greater growth charge and growth potential. This fundamental study thus opens up a path towards the synthesis of supported Cu materials with increased surface areas, which is interesting from a catalytic point of view. Larger surface areas are generally correlated with a better catalyst performance and thus higher product yields. This research can contributed in obtaining new insides into the deposition of metallic nanoparticles on rough surfaces. [GRAPHICS] . | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000568651000001 | Publication Date | 2020-09-12 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 0021-891x | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.9 | Times cited | 3 | Open Access | OpenAccess |
Notes | ; L. Pacquets was supported through a PhD fellowship strategic basic research (1S56918N) of the Research Foundation-Flanders (FWO). N. Daems was supported through a postdoctoral fellowship (12Y3919N-ND) of the Research Foundation-Flanders (FWO). S. Neukermans was supported through an FWO project grant (G093317N). This research was financed by the research counsel of the university of Antwerp (BOF-GOA 33928). The authors recognize the contribution of Thomas Kenis for analytical validation and methodology. ; | Approved | Most recent IF: 2.9; 2020 IF: 2.235 | ||
Call Number | UA @ admin @ c:irua:171588 | Serial | 6603 | ||
Permanent link to this record | |||||
Author | Ramesha, B.M.; Pawlak, B.; Arenas Esteban, D.; Reekmans, G.; Bals, S.; Marchal, W.; Carleer, R.; Adriaensens, P.; Meynen, V. | ||||
Title | Partial hydrolysis of diphosphonate ester during the formation of hybrid Tio₂ nanoparticles : role of acid concentration | Type | A1 Journal article | ||
Year | 2023 | Publication | ChemPhysChem : a European journal of chemical physics and physical chemistry | Abbreviated Journal | |
Volume | Issue | Pages | e202300437-13 | ||
Keywords | A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA) | ||||
Abstract | In the present work, a method was utilized to control the in‐situ partial hydrolysis of a diphosphonate ester in presence of a titania precursor and in function of acid content and its impact on the hybrid nanoparticles was assessed. The hydrolysis degree of organodiphosphonate ester linkers during the formation of hybrid organic‐inorganic metal oxide nanoparticles, are relatively underexplored . Quantitative solution NMR spectroscopy revealed that during the synthesis of TiO2 nanoparticles, an increase in acid concentration introduces a higher degree of partial hydrolysis of the TEPD linker into diverse acid/ester derivatives of TEPD. Increasing the HCl/Ti ratio from 1 to 3, resulted in an increase in degree of partial hydrolysis of the TEPD linker in solution from 4% to 18.8% under the here applied conditions. As a result of the difference in partial hydrolysis, the linker‐TiO2 bonding was altered. Upon subsequent drying of the colloidal TiO2 solution, different textures, at nanoscale and macroscopic scale, were obtained dependent on the HCl/Ti ratio and thus the degree of hydrolysis of TEPD. Understanding such linker‐TiO2 nanoparticle surface dynamics is crucial for making hybrid organic‐inorganic materials (i.e. (porous) metal phosphonates) employed in applications such as electronic/photonic devices, separation technology and heterogeneous catalysts. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 001071673900001 | Publication Date | 2023-09-05 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 1439-4235; 1439-7641 | ISBN | Additional Links | UA library record; WoS full record | |
Impact Factor | 2.9 | Times cited | Open Access | OpenAccess | |
Notes | This work was supported by the Research Foundation-Flanders (FWO Vlaanderen) Project G.0121.17 N. The work was further supported by Hasselt University and the Research Foundation – Flanders (FWO Vlaanderen) via the Hercules project AUHL/15/2 – GOH3816 N. V. M. acknowledges the Research Foundation Flanders (FWO) for project K801621 N. B. M. R. acknowledges, Prof. Dr. Christophe Detavernier and Dr. Davy Deduystche (COCOON, Ghent University) for PXRD and VT-XRD measurements, Prof. Dr. Christophe Van De Velde (iPRACS, University of Antwerp) and Dr. Radu Ciocarlan (LADCA, University of Antwerp) for helpful discussions on PXRD measurements and Dr. Nick Gys (University of Antwerp and VITO) for ICP-OES measurements. | Approved | Most recent IF: 2.9; 2023 IF: 3.075 | ||
Call Number | UA @ admin @ c:irua:198934 | Serial | 8911 | ||
Permanent link to this record | |||||
Author | Debroye, E.; Yuan, H.; Bladt, E.; Baekelant, W.; Van der Auweraer, M.; Hofkens, J.; Bals, S.; Roeffaers, M.B.J. | ||||
Title | Facile morphology-controlled synthesis of organolead iodide perovskite nanocrystals using binary capping agents | Type | A1 Journal article | ||
Year | 2017 | Publication | ChemNanoMat : chemistry of nanomaterials for energy, biology and more | Abbreviated Journal | Chemnanomat |
Volume | 3 | Issue | 3 | Pages | 223-227 |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Controlling the morphology of organolead halide perovskite crystals is crucial to a fundamental understanding of the materials and to tune their properties for device applications. Here, we report a facile solution-based method for morphology-controlled synthesis of rod-like and plate-like organolead halide perovskite nanocrystals using binary capping agents. The morphology control is likely due to an interplay between surface binding kinetics of the two capping agents at different crystal facets. By high-resolution scanning transmission electron microscopy, we show that the obtained nanocrystals are monocrystalline. Moreover, long photoluminescence decay times of the nanocrystals indicate long charge diffusion lengths and low trap/defect densities. Our results pave the way for large-scale solution synthesis of organolead halide perovskite nanocrystals with controlled morphology for future device applications. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000399604300003 | Publication Date | 2017-01-18 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2199-692x | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.937 | Times cited | 19 | Open Access | OpenAccess |
Notes | ; We acknowledge financial support from the Research Foundation-Flanders (FWO, grant G.0197.11, G.0962.13, G0B39.15, postdoctoral fellowship to E. D. and H. Y.), KU Leuven Research Fund (C14/15/053), the Flemish government through long term structural funding Methusalem (CASAS2, Meth/15/04), the Hercules foundation (HER/11/14), the Belgian Federal Science Policy Office (IAP-PH05), the EC through the Marie Curie ITN project iSwitch (GA-642196) and the ERC project LIGHT (GA307523). S. B. acknowledges financial support from European Research Council (ERC Starting Grant # 335078-COLOURATOMS). E. B. gratefully acknowledges financial support by the Flemish Fund for Scientific Research (FWO Vlaanderen). ; ecas_Sara | Approved | Most recent IF: 2.937 | ||
Call Number | UA @ lucian @ c:irua:143678UA @ admin @ c:irua:143678 | Serial | 4656 | ||
Permanent link to this record | |||||
Author | Berthold, T.; Castro, C.R.; Winter, M.; Hoerpel, G.; Kurttepeli, M.; Bals, S.; Antonietti, M.; Fechler, N. | ||||
Title | Tunable nitrogen-doped carbon nanoparticles from tannic acid and urea and their potential for sustainable soots | Type | A1 Journal article | ||
Year | 2017 | Publication | ChemNanoMat : chemistry of nanomaterials for energy, biology and more | Abbreviated Journal | Chemnanomat |
Volume | 3 | Issue | 3 | Pages | 311-318 |
Keywords | A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT) | ||||
Abstract | Nano-sized nitrogen-doped carbon spheres are synthesized from two cheap, readily available and sustainable precursors: tannic acid and urea. In combination with a polymer structuring agent, nitrogen content, sphere size and the surface (up to 400 m(2)g(-1)) can be conveniently tuned by the precursor ratio, temperature and structuring agent content. Because the chosen precursors allow simple oven synthesis and avoid harsh conditions, this carbon nanosphere platform offers a more sustainable alternative to classical soots, for example, as printing pigments or conduction soots. The carbon spheres are demonstrated to be a promising as conductive carbon additive in anode materials for lithium ion batteries. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000403299200006 | Publication Date | 2017-03-10 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2199-692x | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 2.937 | Times cited | 14 | Open Access | OpenAccess |
Notes | ; S.B. is grateful for funding by the European Research Council (ERC starting grant # 335078-COLOURATOMS). ; ecas_Sara | Approved | Most recent IF: 2.937 | ||
Call Number | UA @ lucian @ c:irua:144287UA @ admin @ c:irua:144287 | Serial | 4699 | ||
Permanent link to this record | |||||
Author | Gorbanev, Y.; Engelmann, Y.; van’t Veer, K.; Vlasov, E.; Ndayirinde, C.; Yi, Y.; Bals, S.; Bogaerts, A. | ||||
Title | Al2O3-Supported Transition Metals for Plasma-Catalytic NH3 Synthesis in a DBD Plasma: Metal Activity and Insights into Mechanisms | Type | A1 Journal article | ||
Year | 2021 | Publication | Catalysts | Abbreviated Journal | Catalysts |
Volume | 11 | Issue | 10 | Pages | 1230 |
Keywords | A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Movement Antwerp (MOVANT) | ||||
Abstract | N2 fixation into NH3 is one of the main processes in the chemical industry. Plasma catalysis is among the environmentally friendly alternatives to the industrial energy-intensive Haber-Bosch process. However, many questions remain open, such as the applicability of the conventional catalytic knowledge to plasma. In this work, we studied the performance of Al2O3-supported Fe, Ru, Co and Cu catalysts in plasma-catalytic NH3 synthesis in a DBD reactor. We investigated the effects of different active metals, and different ratios of the feed gas components, on the concentration and production rate of NH3, and the energy consumption of the plasma system. The results show that the trend of the metal activity (common for thermal catalysis) does not appear in the case of plasma catalysis: here, all metals exhibited similar performance. These findings are in good agreement with our recently published microkinetic model. This highlights the virtual independence of NH3 production on the metal catalyst material, thus validating the model and indicating the potential contribution of radical adsorption and Eley-Rideal reactions to the plasma-catalytic mechanism of NH3 synthesis. | ||||
Address | |||||
Corporate Author | Thesis | ||||
Publisher | Place of Publication | Editor | |||
Language | Wos | 000715656300001 | Publication Date | 2021-10-13 | |
Series Editor | Series Title | Abbreviated Series Title | |||
Series Volume | Series Issue | Edition | |||
ISSN | 2073-4344 | ISBN | Additional Links | UA library record; WoS full record; WoS citing articles | |
Impact Factor | 3.082 | Times cited | 19 | Open Access | OpenAccess |
Notes | Catalisti, Moonshot P2C ; Research Foundation – Flanders, GoF9618n ; European Research Council, 810182 SCOPE 815128 REALNANO ; sygmaSB | Approved | Most recent IF: 3.082 | ||
Call Number | EMAT @ emat @c:irua:183279 | Serial | 6815 | ||
Permanent link to this record |