“Jackson Pollock's Number 1A, 1948 : a non-invasive study using macro-x-ray fluorescence mapping (MA-XRF) and multivariate curve resolution-alternating least squares (MCR-ALS) analysis”. Martins A, Coddington J, van der Snickt G, van Driel B, McGlinchey C, Dahlberg D, Janssens K, Dik J, Heritage science 4, 33 (2016). http://doi.org/10.1186/S40494-016-0105-2
Abstract: Jackson Pollock's Number 1A, 1948 painting was investigated using in situ scanning macro-x-ray fluorescence mapping (MA-XRF) to help characterize the artist's materials and his creative process. A multivariate curve resolution-alternating least squares (MCR-ALS) approach was used to examine the hyperspectral data and obtain distribution maps and signature spectra for the paints he used. The composition of the paints was elucidated based on the chemical elements identified in the signature spectra and a tentative list of pigments, fillers and other additives is proposed for eleven different paints and for the canvas. The paint distribution maps were used to virtually reconstruct the artist process and document the sequence and manner in which Pollock applied the different paints, using deliberate and specific gestures.
Keywords: A1 Journal article; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1186/S40494-016-0105-2
|
|
|
van der Snickt G (2012) James Ensor's pigments studied by means of portable and synchrotron radiation-based X-ray techniques : evolution, context and degradation. 501 p
Keywords: Doctoral thesis; Art; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH”. Roekens EJ, Van Grieken RE, Marine chemistry 13, 195 (1983). http://doi.org/10.1016/0304-4203(83)90014-2
Abstract: The rate of iron(II) oxidation in North Sea water of pH 5.510 in the range 1025°C has been studied. The oxygenation rate depends linearly on the iron(II) and dissolved oxygen concentrations. The second-order dependence on [OH−], found by several investigators for synthetic solutions, was confirmed in seawater, but only for pOH > 6.9. For pOH < 5.9 the rate appeared to be independent of the pOH. In the intermediate range, pOH 5.96.9, corresponding to the natural pH of seawater, a first-order dependence on the pOH is obeyed. The important discrepancy in the literature between the second-order rate constant for NaCHO3 solutions and for seawater can be attributed predominantly to the incorrect assumption of a second-order pOH dependence in natural seawater. The results can be useful, for example, in predicting the effect of dumping acidic iron waste from the titanium-dioxide industry into the ocean.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(83)90014-2
|
|
|
“Kinetics of iron(II) oxidation in seawater of various pH : reply”. Roekens EJ, Van Grieken RE, Marine chemistry 15, 281 (1984). http://doi.org/10.1016/0304-4203(84)90025-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0304-4203(84)90025-2
|
|
|
“Kultuurpatrimonium, zure regen en energie”. Van Grieken R, Fobe B, Energie en milieu: tijdschrift over energie en leefmilieu , 10 (1990)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laminated altered layers in historical glass : density variations of silica nanoparticle random packings as explanation for the observed lamellae”. Schalm O, Anaf W, Journal of non-crystalline solids 442, 1 (2016). http://doi.org/10.1016/J.JNONCRYSOL.2016.03.019
Abstract: One of the most striking but unexplained phenomena in the natural degradation of glass is the transformation of an almost colorless, transparent and homogeneous glass into a colored, opaque and heterogeneous degradation layer. In many cases, the degradation layer consists of numerous lamellae with a thickness between 0.1 and 10 pm. However, both internal structure and formation proess of laminated degradation layers remain unclear. In this paper, a model is proposed where we assume that transformed (degraded) glass consists of a random packing of nano-sized silica particles while the lamellae are the result of different packing densities. The model is able to connect the texture of numerous lamellae observed by several types of microscopic techniques with the structure at molecular level determined by means of chemical analysis. In addition, the model is able to explain numerous properties such as the parameters responsible for the contrast between lamellae. This contrast can be caused by differences in color, density, elemental composition, or surface roughness. (C) 2016 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1016/J.JNONCRYSOL.2016.03.019
|
|
|
“LAMMA analysis of inorganic ammonium compounds in individual marine aerosol particles”. Otten P, Bruynseels, Van Grieken R, (1986)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“LAMMA and electron-microprobe analysis of atmospheric aerosols”. Bruynseels F, Storms H, Van Grieken R, Journal de physique 45, 785 (1984). http://doi.org/10.1051/JPHYSCOL:19842180
Abstract: A laser microprobe mass analyser and a highly automated electron probe X-ray microanalysis unit have been used to study the elemental composition, inorganic speciation and morphology of atmospheric aerosols collected at various remote to polluted and marine to continental locations.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1051/JPHYSCOL:19842180
|
|
|
“LAMMA : calibration and application to nephrotoxicology studies”. Verbueken A, Paulus G, Van de Vyver F, Verpooten G, de Broe M, Van Grieken R, (1983)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA in nephrotoxicity studies”. Verbueken AH, Paulus GJ, Van de Vyver FL, Verpooten GA, Visser WJ, de Broe ME, Van Grieken RE, (1984)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“LAMMA-study of aerosol samples collected in the Amazon basin”. Bruynseels F, Artaxo P, Storms H, Van Grieken R page 355 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Hellemans K (2019) Laser ablation ICP-MS as a tool for surface analysis in comparison to other elemental analysis methods. 229 p
Abstract: Dit onderzoek presenteert een overzicht van de mogelijkheden van LA-ICP-MS als een techniek voor kwantitatieve analyse, bepalen van isotoopverhoudingen en elementaire beeldvorming. Hiervoor wordt de techniek zelf voorgesteld en worden de belangrijkste parameters die een invloed hebben op de kwaliteit van een LA-ICP-MS meting beschreven. Voor kwantitieve analyse worden de huidige calibratiestrategieën voor LA-ICP-MS toegelicht, zowel op het vlak van selectie en bereiding van standaarden als op het vlak van dataverwerking. Daarnaast werd een nieuwe calibratiestrategie voorgesteld, gebaseerd op een lineaire combinatie van standaarden. Een case study met de traditionele calibratiestrategie uit de literatuur werd uitgevoerd en vergeleken met data van SEM-EDX om een referentiekader te schetsen voor de performantie van de techniek. In een tweede case study werd onze nieuwe calibratiestrategie toegepast en werd er uitsluitend gebruik gemaakt van LA-ICP-MS, wat uitstekende resultaten opleverde. Met het oog op het bepalen van isotoopverhoudingen, werd er onderzocht wat de limieten zijn van het gebruik van een lage resolutie quadrupool massaspectrometer voor deze bepaling. Dit stelde ons in staat om de te verwachten accuraatheid en precisie in te schatten. De performantie bleek goed genoeg te zijn om weapon-grade plutonium te onderscheiden van global fall-out, zoals het werd aangetoond in de case study omtrent dit onderwerp. Uiteindelijk hebben we ook LA-ICP-MS geëvalueerd als een techniek voor elementaire beeldvorming, waarbij we tevens de meest courante multivariate data analyse hebben beschreven. Om de techniek te plaatsen tegenover andere elementaire technieken, werd een historisch verffragment geanalyseerd dat in het verleden reeds geanalyseerd was met SEM-EDX and μ-XRD. Op die manier konden we de resultaten accuraat vergelijken met de andere technieken.
Keywords: Doctoral thesis; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis : a review of applications in the life sciences”. Verbueken AH, Bruynseels FJ, Van Grieken RE, Biomedical mass spectrometry 12, 438 (1985). http://doi.org/10.1002/BMS.1200120903
Abstract: The characteristics and analytical utility of laser microprobe mass analysis (LAMMA) are described and evaluated, and a short history of this recent microanalytical technique is presented. A review of the areas of application of LAMMA and related laser microprobes is presented with special emphasis on applications in the life sciences.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/BMS.1200120903
|
|
|
van de Vijver FL, Verbueken AH, Van Grieken RE, de Broe ME, Visser WJ (1985) Laser microprobe mass analysis : a tool for evaluating histochemical staining of trace elements. 351–352
Keywords: L1 Letter to the editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis : characteristics and applications”. Van Grieken R, Verbueken A, Bruynseels F, Vandeputte D, Goossenaerts C, Leysen L, Otten P, Wouters L, (1987)
Keywords: P3 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser microprobe mass analysis (LAMMA) in nephrological investigations”. Verbueken AH, Van de Vyver FL, Paulus GJ, Visser WJ, Verpooten GA, de Broe ME, Van Grieken RE page 375 (1984).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) of parathyroid glands from dialysis patients”. Verbueken AH, Van de Vyver FL, Nouwen EJ, Roels F, de Broe ME, Van Grieken RE page 443 (1987).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
|
|
“Laser microprobe mass analysis (LAMMA) to study lead intoxication at the subcellular level”. Vandeputte DF, Verbueken AH, Jacob WA, Van Grieken RE, Acta pharmacologica et toxicologica 59, 617 (1986). http://doi.org/10.1111/J.1600-0773.1986.TB02840.X
Keywords: A3 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1111/J.1600-0773.1986.TB02840.X
|
|
|
“Laser microprobe mass analysis (LAMMA) to verify the aluminon staining of bone”. Verbueken AH, van de Vijver FL, Visser WJ, Van Grieken RE, de Broe ME, Stain technology 61, 287 (1986). http://doi.org/10.3109/10520298609109955
Abstract: Triammonium aurin tricarboxylate (aluminon) has been used to localize aluminum in 2 μm sections of undecalcified, methyl methacrylate embedded bone obtained from patients with terminal chronic renal failure. Aluminum appeared in four cases as bright red lines at the mineralized-bone boundary. In two cases, however, purplish lines were found and one patient showed red as well as purplish lines. Laser microprobe mass analysis (LAMMA) identified aluminum at the location of the red lines and both aluminum and iron at the purplish lines. Furthermore, both iron and aluminum were found in histiocytic bone marrow cells, which showed brownish aluminon staining. It appears that when aluminum and iron occur together, aluminon staining may yield aberrant results. This study shows that LAMMA can be used for the identification of elements sought by histochemical methods and thus permits the evaluation of their staining effects.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.3109/10520298609109955
|
|
|
“Laser microprobe mass analysis of individual Antarctic aerosol particles”. Wouters L, Artaxo P, Van Grieken R, International journal of environmental analytical chemistry 38, 427 (1990). http://doi.org/10.1080/03067319008026946
Abstract: Individual Antarctic aerosol particles in the 0.54 μm aerodynamic diameter range were analyzed using laser microprobe mass analysis (LAMMA). As they were sampled near the ocean, the great majority consists of seasalt, transformed to various degrees in the atmosphere. Major alterations include the association of an excess sulfate and methane sulfonate with these particles. Sulfate-rich particles containing little or no chloride were found mostly in the smallest size fraction (0.51 μm), where they account for some 5% of all particles: they are most likely highly transformed seasalt. Aluminosilicates, on the other hand, only appear among the coarser particles: they represent 2% of the particulates in the 24 μm range. The remainder of the aerosol consists of organic, Fe-rich, K-rich and Zn-rich particles. The latter groups have very low abundances: always less than 1% of the population of the impactor stage(s) onto which they were collected.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067319008026946
|
|
|
“Laser microprobe mass analysis of individual North Sea aerosol particles”. Dierck I, Michaud D, Wouters L, Van Grieken R, Environmental science and technology 26, 802 (1992). http://doi.org/10.1021/ES00028A021
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES00028A021
|
|
|
“Laser microprobe mass spectrometric identification of cyclosporine-induced intrarenal microliths in rat”. Verbueken AH, Van Grieken RE, Verpooten GA, de Broe ME, Wedeen RP, Biological mass spectrometry 21, 590 (1992). http://doi.org/10.1002/BMS.1200211111
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200211111
|
|
|
“Laser microprobe mass spectrometric identification of sulfur species in single micrometer-size particles”. Bruynseels FJ, Van Grieken RE, Analytical chemistry 56, 871 (1984). http://doi.org/10.1021/AC00270A004
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00270A004
|
|
|
“Laser microprobe mass spectrometry : 1 : basic principles and performance characteristics”. Denoyer E, Van Grieken R, Adams F, Ntausch DFS, Analytical chemistry 54, 26a (1982). http://doi.org/10.1021/AC00238A722
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00238A722
|
|
|
“Laser microprobe mass spectrometry of platinum in dog kidney after cisplatin adminstration”. Verbueken AH, Van Grieken RE, Paulus GJ, Verpooten GA, de Broe ME, Biomedical mass spectrometry 11, 159 (1984). http://doi.org/10.1002/BMS.1200110404
Abstract: By means of laser microprobe mass analysis (LAMMA) platinum was detected in the renal proximal tubular cells of a dog that had been intravenously adminstered the antitumor drug cisplatin (5 mg per kg body weight). No definite subcellular localization of the heavy metal was obtained. Sample prparation and analytical features are examined to increase spatial resolution of analysis while maintaining sufficient detection efficiency. The LAMMA method is destructive, but the amount and type of evaporated material can readily be determined when using LAMMA in combination with transmission electron microscopy. Instrumental optimization and standardization of mass signals is possible by using platinum-loaded, ion chelating resin beads embedded and sectioned with the tissue.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1002/BMS.1200110404
|
|
|
“Leaching of nutrients and trace metals from aerosol samples: a comparison between a re-circulation and an ultrasound system”. Eyckmans K, Zhang J, de Hoog J, Joos P, Van Grieken R, International journal of environmental analytical chemistry 80, 227 (2001). http://doi.org/10.1080/03067310108044372
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067310108044372
|
|
|
“Leaching of two fungicides in spent mushroom substrate amended soil : I influence of amendment rate, fungicide ageing and flow condition”. Álvarez-Martín A, Sanchez-Martin MJ, Ordax JM, Marin-Benito JM, Sonia Rodriguez-Cruz M, The science of the total environment 584, 828 (2017). http://doi.org/10.1016/J.SCITOTENV.2017.01.126
Abstract: A study has been conducted on the leaching of two fungicides, tebuconazole and cymoxanil, in a soil amended with spent mushroom substrate (SMS), with an evaluation of how different factors influence this process.The objective was based on the potential use of SMS as a biosorbent for immobilizing pesticides in vulnerable soils, and the need to know how it could affect the subsequent transport of these retained compounds. Breakthrough curves (BTCs) for C-14-fungicides, non-incubated and incubated over 30 days, were obtained in columns packed with an unamended soil (S), and this soil amended with SMS at rates of 5% (S + SMS5) and 50% (S + SMS50) under saturated and saturated-unsaturated flows. The highest leaching of tebuconazole (> 50% of the total C-14 added) was found in S when a saturated water flow was applied to the column, but the percentage of leached fungidde decreased when a saturated-unsaturated flow was applied in both SMS-amended soils. Also a significant decrease in teaching was observed for tebuconazole after incubation in the column, especially in S + SMS50 when both flows were applied. Furthermore, cymoxanil leaching was complete in S and S + SMS when a saturated flow was applied, and maximum peak concentrations were reached at 1 pore volume (PV), although BTCs showed peaks with lower concentrations in S + SMS. The amounts of cymoxanil retained only increased in S + SMS when a saturated-unsaturated flow was applied. A more relevant effect of SMS for reducing the leaching of fungidde was observed when cymoxanil was previously incubated in the column, although mineralization was enhanced in this case. These results are of interest for extending SMS application on the control of the leaching of fungicides with different physicochemical characteristics after different ageing times in the soil and water flow conditions applied. (C) 2017 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SCITOTENV.2017.01.126
|
|
|
“Lead particles in an urban atmosphere : an individual particle approach”. Van Borman W, Wouters L, Van Grieken R, Adams F, The science of the total environment 90, 55 (1990). http://doi.org/10.1016/0048-9697(90)90185-W
Abstract: In air particulate matter, sampled at a suburban site near the city of Antwerp, Belgium, more than 1500 individual Pb-containing aerosol particles with projected diameters between 0.2 and 15 μm were analyzed by automated electron probe X-ray micro analysis (EPXMA) for 26 elements and morphological features. Laser microprobe mass analysis (LAMMA) was used to detect elements with Z < 11, particularly ammonium compounds. The Pb-containing particles were classified into five main classes: Pb-sulfates, Pb-halides, soil related Pb, Pb associated with medium atomic number elements and Pb associated with high atomic number elements. Each class was divided into several distinct particle types, of which the abundance (in number and mass %), the mean projected particle diameter, and the chemical composition were determined. Auto exhaust products are responsible for Pb-sulfates and Pb-halides, making up respectively 66.7 and 27.8% by mass of the Pb-containing particles. Ammonium sulfate coatings were found to be present on nearly all Pb particles. The observations were correlated with daily concentrations of Pb and Br, obtained by particle induced X-ray emission analysis (PIXE).
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0048-9697(90)90185-W
|
|
|
“Light element analysis of individual microparticles using thin-window EPMA”. Osán J, Szalóki I, Ro C-U, Van Grieken R, Microchimica acta 132, 349 (2000). http://doi.org/10.1007/S006040050079
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S006040050079
|
|
|
“Literature trends in x-ray emission spectrometry in the period 1990-2000: a review”. Injuk J, Van Grieken R, X-ray spectrometry 32, 35 (2003). http://doi.org/10.1002/XRS.606
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.606
|
|