“Quenching of the Hall effect in localised high magnetic field regions”. Novoselov KS, Geim AK, Dubonos SV, Cornelissens YG, Peeters FM, Maan JC, Physica. E: Low-dimensional systems and nanostructures 12, 244 (2002). http://doi.org/10.1016/S1386-9477(01)00364-2
Abstract: We report the suppression of the Hall effect in a mesoscopic Hall cross with a strong magnetic field only in the centre and vanishingly small outside, The local magnetic field is produced by placing Dy pillar on top of a structure with a high-mobility two-dimensional electron gas. The effect is found to be due to a sharp increase of the number of back-scattered and quasi-localised electron orbits. The possibility of localising electrons inside the magnetic inhomogeneity region is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 3
DOI: 10.1016/S1386-9477(01)00364-2
|
|
“Resonant magnetopolaron effect in GaAs/AlGaAs multiple quantum well structures”. Wang YJ, Nichel HA, McCombe BD, Peeters FM, Shi JM, Hai GQ, Wu XG, Eustis TJ, Schaff W, Physica. E: Low-dimensional systems and nanostructures 2, 161 (1998). http://doi.org/10.1016/S1386-9477(98)00035-6
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
DOI: 10.1016/S1386-9477(98)00035-6
|
|
“Spatial interference induced spin polarization in a three-terminal quantum ring”. Kálmán O, Földi P, Benedict MG, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 40, 567 (2008). http://doi.org/10.1016/j.physe.2007.08.014
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 27
DOI: 10.1016/j.physe.2007.08.014
|
|
“Spin-engineered quantum dots”. Fleurov V, Ivanov VA, Peeters FM, Vagner ID, Physica. E: Low-dimensional systems and nanostructures 14, 361 (2002). http://doi.org/10.1016/S1386-9477(01)00487-8
Abstract: Spatially nonhomogeneously spin polarized nuclei are proposed as a new mechanism to monitor electron states in a nanostructure, or as a means to create and, if necessary, reshape such nanostructures in the course of the experiment. We found that a polarization of nuclear spins may lift the spin polarization of the electron states in a nanostructure and, if sufficiently strong, leads to a polarization of the electron spins. Polarized nuclear spins may form an energy landscape capable of binding electrons with energy up to several meV and the localization radius > 100 Angstrom. (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 12
DOI: 10.1016/S1386-9477(01)00487-8
|
|
“The spin structure of two vertically coupled quantum dots”. Partoens B, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 6, 577 (2000). http://doi.org/10.1016/S1386-9477(99)00114-9
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 2
DOI: 10.1016/S1386-9477(99)00114-9
|
|
“Strong resonant intersubband magnetopolaron effect in heavily modulation-doped GaAs/AlGaAs single quantum wells at high magnetic fields”. Wang YJ, Leem YA, McCombe BD, Wu XG, Peeters FM, Jones E, Reno J, Lee XY, Jiang HW, Physica. E: Low-dimensional systems and nanostructures 6, 195 (2000). http://doi.org/10.1016/S1386-9477(99)00086-7
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 2
DOI: 10.1016/S1386-9477(99)00086-7
|
|
“Theory of the band mixing induced negative magnetoresistance in broken gap superlattices”. Symons DM, Peeters FM, Lakrimi M, Khym S, Portal JC, Mason NJ, Nicholas RJ, Walker PJ, Physica. E: Low-dimensional systems and nanostructures 2, 353 (1998). http://doi.org/10.1016/S1386-9477(98)00074-5
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 4
DOI: 10.1016/S1386-9477(98)00074-5
|
|
“Theory of trions in quantum wells”. Riva C, Peeters FM, Varga K, Physica. E: Low-dimensional systems and nanostructures
T2 –, 14th International Conference on the Electronic Properties of, Two-Dimensional Systems, JUL 30-AUG 03, 2001, PRAGUE, CZECH REPUBLIC 12, 543 (2002). http://doi.org/10.1016/S1386-9477(01)00484-2
Abstract: We investigate the energy levels of the negatively and positively charged excitons (also called trions) in a 200 Angstrom wide GaAs quantum well in the presence of a perpendicular magnetic field. A comparison is made with the experimental results of Glasberg et al. (Phys. Rev. B. 59 (1999) R10 425) and of Yusa et al. (cond-mat/0103505). (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 2
DOI: 10.1016/S1386-9477(01)00484-2
|
|
“Transition from two-dimensional to three-dimensional classical artificial atoms”. Cornelissens YG, Partoens B, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 8, 314 (2000). http://doi.org/10.1016/S1386-9477(00)00163-6
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 16
DOI: 10.1016/S1386-9477(00)00163-6
|
|
“Two-level anti-crossings high up in the single-particle energy spectrum of a quantum dot”. Payette C, Austing DG, Yu G, Gupta JA, Nair SV, Partoens B, Amaha S, Tarucha S, Physica. E: Low-dimensional systems and nanostructures 40, 1807 (2008). http://doi.org/10.1016/j.physe.2007.09.060
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 8
DOI: 10.1016/j.physe.2007.09.060
|
|
“Type of phase transitions in a mesoscopic superconducting disc”. Deo PS, Schweigert VA, Peeters FM, Geim AK, Physica: E 1, 297 (1997). http://doi.org/10.1016/S1386-9477(97)00063-5
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
DOI: 10.1016/S1386-9477(97)00063-5
|
|
“Vortex states in mescopic superconductors”. Peeters FM, Baelus BJ, Milošević, MV, Physica. E: Low-dimensional systems and nanostructures 18, 312 (2003). http://doi.org/10.1016/S1386-9477(02)01058-5
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 1
DOI: 10.1016/S1386-9477(02)01058-5
|
|
“Vortex structure of few-electron quantum dots”. Anisimovas E, Tavernier MB, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 40, 1621 (2008). http://doi.org/10.1016/j.physe.2007.10.031
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 1
DOI: 10.1016/j.physe.2007.10.031
|
|
“Effect of substitutional impurities on the electronic transport properties of graphene”. Berdiyorov GR, Bahlouli H, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 84, 22 (2016). http://doi.org/10.1016/j.physe.2016.05.024
Abstract: Density-functional theory in combination with the nonequilibrium Green's function formalism is used to study the effect of substitutional doping on the electronic transport properties of hydrogen passivated zig-zag graphene nanoribbon devices. B, N and Si atoms are used to substitute carbon atoms located at the center or at the edge of the sample. We found that Si -doping results in better electronic transport as compared to the other substitutions. The transmission spectrum also depends on the location of the substitutional dopants: for single atom doping the largest transmission is obtained for edge substitutions, whereas substitutions in the middle of the sample give larger transmission for double carbon substitutions. The obtained results are explained in terms of electron localization in the system due to the presence of impurities. (C) 2016 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 2.221
Times cited: 17
DOI: 10.1016/j.physe.2016.05.024
|
|
“Wave packet propagation through branched quantum rings under applied magnetic fields”. de Sousa AA, Chaves A, Pereira TAS, de Farias GA, Peeters FM, Physica. E: Low-dimensional systems and nanostructures 114, 113598 (2019). http://doi.org/10.1016/J.PHYSE.2019.113598
Abstract: We investigate the effect of opening and closing pathways on the dynamics of electron wave packets in semiconductor quantum rings with different geometries. Our analysis is based on the time evolution of an electron wave packet, within the effective-mass approximation. We demonstrate that opening an extra channel in the quantum ring does not necessarily improve the electron transmission and, depending on the extra channel width, may even reduce it, either due to enhancement of quantum scattering or due to interference. In the latter case, transmission reduction can be controlled through the Aharonov-Bohm phase of the wave function, via an applied magnetic field. It is also shown that, closing one of the channels of the quantum ring, system improves the transmission probability under specific conditions, an effect which is a quantum analog of the Braess paradox.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 2.221
DOI: 10.1016/J.PHYSE.2019.113598
|
|
“Theoretical prediction of the PtOX (X = S and Se) monolayers as promising optoelectronic and thermoelectric 2D materials”. Nguyen DK, Hoat DM, Bafekry A, Van On V, Rivas-Silva JF, Naseri M, Cocoletzi GH, Physica E-Low-Dimensional Systems &, Nanostructures 131, 114732 (2021). http://doi.org/10.1016/J.PHYSE.2021.114732
Abstract: In this paper, two new monolayers, namely PtOS and PtOSe, are theoretically predicted using first-principles calculations. Structural, electronic, optical and thermoelectric properties are explored using full-potential linearized augmented plane-wave (FP-LAPW) method and the semiclassical Boltzmann transport theory. Predicted two-dimensional (2D) materials show good dynamical, thermodynamic and structural stability. Calculated electronic structures indicate the indirect gap semiconductor nature of the PtOS and PtOSe single layers with energy gap of 1.346(2.436) and 0.978(1.978) eV as calculated with the WC(HSE06) functional, respectively. Density of states spectra and valence charge distribution maps suggest a mix of covalent and ionic characters of the chemical bonds. 2D materials at hand exhibit good absorption property in the visible regime with coefficient value reaching the order of 105/cm, even much larger in the ultraviolet, suggesting the promising optoelectronic applicability. Finally, the thermoelectric parameters including electrical conductivity, thermal conductivity, Seebeck coefficient, power factor and figure of merit are determined and analyzed. Results indicate prospective thermoelectric performance of both considered single layers as demonstrated by large figure of merit close to unity. Our work introduces two new 2D multifunctional materials that may possess potential applications in the optoelectronic and thermoelectric nano-devices.
Keywords: A1 Journal article; Engineering sciences. Technology; Condensed Matter Theory (CMT)
Impact Factor: 2.221
DOI: 10.1016/J.PHYSE.2021.114732
|
|
“Evaluation of different rectangular scan strategies for STEM imaging”. Velazco A, Nord M, Béché, A, Verbeeck J, Ultramicroscopy , 113021 (2020). http://doi.org/10.1016/j.ultramic.2020.113021
Abstract: STEM imaging is typically performed by raster scanning a focused electron probe over a sample. Here we investigate and compare three different scan patterns, making use of a programmable scan engine that allows to arbitrarily set the sequence of probe positions that are consecutively visited on the sample. We compare the typical raster scan with a so-called ‘snake’ pattern where the scan direction is reversed after each row and a novel Hilbert scan pattern that changes scan direction rapidly and provides an homogeneous treatment of both scan directions. We experimentally evaluate the imaging performance on a single crystal test sample by varying dwell time and evaluating behaviour with respect to sample drift. We demonstrate the ability of the Hilbert scan pattern to more faithfully represent the high frequency content of the image in the presence of sample drift. It is also shown that Hilbert scanning provides reduced bias when measuring lattice parameters from the obtained scanned images while maintaining similar precision in both scan directions which is especially important when e.g. performing strain analysis. Compared to raster scanning with flyback correction, both snake and Hilbert scanning benefit from dose reduction as only small probe movement steps occur.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 13
DOI: 10.1016/j.ultramic.2020.113021
|
|
“Atom column detection from simultaneously acquired ABF and ADF STEM images”. Fatermans J, den Dekker Aj, Müller-Caspary K, Gauquelin N, Verbeeck J, Van Aert S, Ultramicroscopy 219, 113046 (2020). http://doi.org/10.1016/j.ultramic.2020.113046
Abstract: In electron microscopy, the maximum a posteriori (MAP) probability rule has been introduced as a tool to determine the most probable atomic structure from high-resolution annular dark-field (ADF) scanning transmission electron microscopy (STEM) images exhibiting low contrast-to-noise ratio (CNR). Besides ADF imaging, STEM can also be applied in the annular bright-field (ABF) regime. The ABF STEM mode allows to directly visualize light-element atomic columns in the presence of heavy columns. Typically, light-element nanomaterials are sensitive to the electron beam, limiting the incoming electron dose in order to avoid beam damage and leading to images exhibiting low CNR. Therefore, it is of interest to apply the MAP probability rule not only to ADF STEM images, but to ABF STEM images as well. In this work, the methodology of the MAP rule, which combines statistical parameter estimation theory and model-order selection, is extended to be applied to simultaneously acquired ABF and ADF STEM images. For this, an extension of the commonly used parametric models in STEM is proposed. Hereby, the effect of specimen tilt has been taken into account, since small tilts from the crystal zone axis affect, especially, ABF STEM intensities. Using simulations as well as experimental data, it is shown that the proposed methodology can be successfully used to detect light elements in the presence of heavy elements.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.2
Times cited: 9
DOI: 10.1016/j.ultramic.2020.113046
|
|
“HAADF-STEM block-scanning strategy for local measurement of strain at the nanoscale”. Prabhakara V, Jannis D, Guzzinati G, Béché, A, Bender H, Verbeeck J, Ultramicroscopy 219, 113099 (2020). http://doi.org/10.1016/j.ultramic.2020.113099
Abstract: Lattice strain measurement of nanoscale semiconductor devices is crucial for the semiconductor industry as strain substantially improves the electrical performance of transistors. High resolution scanning transmission electron microscopy (HR-STEM) imaging is an excellent tool that provides spatial resolution at the atomic scale and strain information by applying Geometric Phase Analysis or image fitting procedures. However, HR-STEM images regularly suffer from scanning distortions and sample drift during image acquisition. In this paper, we propose a new scanning strategy that drastically reduces artefacts due to drift and scanning distortion, along with extending the field of view. It consists of the acquisition of a series of independent small subimages containing an atomic resolution image of the local lattice. All subimages are then analysed individually for strain by fitting a nonlinear model to the lattice images. The method allows flexible tuning of spatial resolution and the field of view within the limits of the dynamic range of the scan engine while maintaining atomic resolution sampling within the subimages. The obtained experimental strain maps are quantitatively benchmarked against the Bessel diffraction technique. We demonstrate that the proposed scanning strategy approaches the performance of the diffraction technique while having the advantage that it does not require specialized diffraction cameras.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 4
DOI: 10.1016/j.ultramic.2020.113099
|
|
“Hidden Markov model for atom-counting from sequential ADF STEM images: Methodology, possibilities and limitations”. De wael A, De Backer A, Van Aert S, Ultramicroscopy 219, 113131 (2020). http://doi.org/10.1016/j.ultramic.2020.113131
Abstract: We present a quantitative method which allows us to reliably measure dynamic changes in the atomic structure of monatomic crystalline nanomaterials from a time series of atomic resolution annular dark field scanning transmission electron microscopy images. The approach is based on the so-called hidden Markov model and estimates the number of atoms in each atomic column of the nanomaterial in each frame of the time series. We discuss the origin of the improved performance for time series atom-counting as compared to the current state-of-the-art atom-counting procedures, and show that the so-called transition probabilities that describe the probability for an atomic column to lose or gain one or more atoms from frame to frame are particularly important. Using these transition probabilities, we show that the method can also be used to estimate the probability and cross section related to structural changes. Furthermore, we explore the possibilities for applying the method to time series recorded under variable environmental conditions. The method is shown to be promising for a reliable quantitative analysis of dynamic processes such as surface diffusion, adatom dynamics, beam effects, or in situ experiments.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2020.113131
|
|
“Source/drain materials for Ge nMOS devices: phosphorus activation in epitaxial Si, Ge, Ge1-xSnx and SiyGe1-x-ySnx”. Vohra A, Makkonen I, Pourtois G, Slotte J, Porret C, Rosseel E, Khanam A, Tirrito M, Douhard B, Loo R, Vandervorst W, Ecs Journal Of Solid State Science And Technology 9, 044010 (2020). http://doi.org/10.1149/2162-8777/AB8D91
Abstract: This paper benchmarks various epitaxial growth schemes based on n-type group-IV materials as viable source/drain candidates for Ge nMOS devices. Si:P grown at low temperature on Ge, gives an active carrier concentration as high as 3.5 x 10(20) cm(-3) and a contact resistivity down to 7.5 x 10(-9) Omega.cm(2). However, Si:P growth is highly defective due to large lattice mismatch between Si and Ge. Within the material stacks assessed, one option for Ge nMOS source/drain stressors would be to stack Si:P, deposited at contact level, on top of a selectively grown n-SiyGe1-x-ySnx at source/drain level, in line with the concept of Si passivation of n-Ge surfaces to achieve low contact resistivities as reported in literature (Martens et al. 2011 Appl. Phys. Lett., 98, 013 504). The saturation in active carrier concentration with increasing P (or As)-doping is the major bottleneck in achieving low contact resistivities for as-grown Ge or SiyGe1-x-ySnx. We focus on understanding various dopant deactivation mechanisms in P-doped Ge and Ge1-xSnx alloys. First principles simulation results suggest that P deactivation in Ge and Ge1-xSnx can be explained both by P-clustering and donor-vacancy complexes. Positron annihilation spectroscopy analysis, suggests that dopant deactivation in P-doped Ge and Ge1-xSnx is primarily due to the formation of P-n-V and SnmPn-V clusters. (C) 2020 The Author(s). Published on behalf of The Electrochemical Society by IOP Publishing Limited.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.2
DOI: 10.1149/2162-8777/AB8D91
|
|
“Reducing electron beam damage through alternative STEM scanning strategies, Part I: Experimental findings”. Velazco A, Béché, A, Jannis D, Verbeeck J, Ultramicroscopy 232, 113398 (2022). http://doi.org/10.1016/j.ultramic.2021.113398
Abstract: The highly energetic electrons in a transmission electron microscope (TEM) can alter or even completely destroy the structure of samples before sufficient information can be obtained. This is especially problematic in the case of zeolites, organic and biological materials. As this effect depends on both the electron beam and the sample and can involve multiple damage pathways, its study remained difficult and is plagued with irreproducibility issues, circumstantial evidence, rumors, and a general lack of solid data. Here we take on the experimental challenge to investigate the role of the STEM scan pattern on the damage behavior of a commercially available zeolite sample with the clear aim to make our observations as reproducible as possible. We make use of a freely programmable scan engine that gives full control over the tempospatial distribution of the electron probe on the sample and we use its flexibility to obtain multiple repeated experiments under identical conditions comparing the difference in beam damage between a conventional raster scan pattern and a newly proposed interleaved scan pattern that provides exactly the same dose and dose rate and visits exactly the same scan points. We observe a significant difference in beam damage for both patterns with up to 11 % reduction in damage (measured from mass loss). These observations demonstrate without doubt that electron dose, dose rate and acceleration voltage are not the only parameters affecting beam damage in (S)TEM experiments and invite the community to rethink beam damage as an unavoidable consequence of applied electron dose.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 18
DOI: 10.1016/j.ultramic.2021.113398
|
|
“Event driven 4D STEM acquisition with a Timepix3 detector: Microsecond dwell time and faster scans for high precision and low dose applications”. Jannis D, Hofer C, Gao C, Xie X, Béché, A, Pennycook Tj, Verbeeck J, Ultramicroscopy 233, 113423 (2022). http://doi.org/10.1016/j.ultramic.2021.113423
Abstract: Four dimensional scanning transmission electron microscopy (4D STEM) records the scattering of electrons in a material in great detail. The benefits offered by 4D STEM are substantial, with the wealth of data it provides facilitating for instance high precision, high electron dose efficiency phase imaging via centre of mass or ptychography based analysis. However the requirement for a 2D image of the scattering to be recorded at each probe position has long placed a severe bottleneck on the speed at which 4D STEM can be performed. Recent advances in camera technology have greatly reduced this bottleneck, with the detection efficiency of direct electron detectors being especially well suited to the technique. However even the fastest frame driven pixelated detectors still significantly limit the scan speed which can be used in 4D STEM, making the resulting data susceptible to drift and hampering its use for low dose beam sensitive applications. Here we report the development of the use of an event driven Timepix3 direct electron camera that allows us to overcome this bottleneck and achieve 4D STEM dwell times down to 100 ns; orders of magnitude faster than what has been possible with frame based readout. We characterize the detector for different acceleration voltages and show that the method is especially well suited for low dose imaging and promises rich datasets without compromising dwell time when compared to conventional STEM imaging.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 31
DOI: 10.1016/j.ultramic.2021.113423
|
|
“Reliable phase quantification in focused probe electron ptychography of thin materials”. Hofer C, Pennycook TJ, Ultramicroscopy 254, 113829 (2023). http://doi.org/10.1016/j.ultramic.2023.113829
Abstract: Electron ptychography provides highly sensitive, dose efficient phase images which can be corrected for aberrations after the data has been acquired. This is crucial when very precise quantification is required, such as with sensitivity to charge transfer due to bonding. Drift can now be essentially eliminated as a major impediment to focused probe ptychography, which benefits from the availability of easily interpretable simultaneous Z-contrast imaging. However challenges have remained when quantifying the ptychographic phases of atomic sites. The phase response of a single atom has a negative halo which can cause atoms to reduce in phase when brought closer together. When unaccounted for, as in integrating methods of quantification, this effect can completely obscure the effects of charge transfer. Here we provide a new method of quantification that overcomes this challenge, at least for 2D materials, and is robust to experimental parameters such as noise, sample tilt.
Keywords: A1 Journal Article; Electron Microscopy for Materials Science (EMAT) ;
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2023.113829
|
|
“Nanowire facilitated transfer of sensitive TEM samples in a FIB”. Gorji S, Kashiwar A, Mantha LS, Kruk R, Witte R, Marek P, Hahn H, Kübel C, Scherer T, Ultramicroscopy 219, 113075 (2020). http://doi.org/10.1016/J.ULTRAMIC.2020.113075
Abstract: We introduce a facile approach to transfer thin films and other mechanically sensitive TEM samples inside a FIB with minimal introduction of stress and bending. The method is making use of a pre-synthetized flexible freestanding Ag nanowire attached to the tip of a typical tungsten micromanipulator inside the FIB. The main advantages of this approach are the significantly reduced stress-induced bending during transfer and attachment of the TEM sample, the very short time required to attach and cut the nanowire, the operation at very low dose and ion current, and only using the e-beam for Pt deposition during the transfer of sensitive TEM samples. This results in a reduced sample preparation time and reduced exposure to the ion beam or e-beam for Pt deposition during the sample preparation and thus also reduced contamination and beam damage. The method was applied to a number of thin films and different TEM samples in order to illustrate the advantageous benefits of the concept. In particular, the technique has been successfully tested for the transfer of a thin film onto a MEMS heating chip for in situ TEM experiments.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/J.ULTRAMIC.2020.113075
|
|
“Dynamical diffraction of high-energy electrons investigated by focal series momentum-resolved scanning transmission electron microscopy at atomic resolution”. Robert Hl, Lobato I, Lyu Fj, Chen Q, Van Aert S, Van Dyck D, Müller-Caspary K, Ultramicroscopy 233, 113425 (2022). http://doi.org/10.1016/j.ultramic.2021.113425
Abstract: We report a study of scattering dynamics in crystals employing momentum-resolved scanning transmission
electron microscopy under varying illumination conditions. As we perform successive changes of the probe
focus, multiple real-space signals are obtained in dependence of the shape of the incident electron wave.
With support from extensive simulations, each signal is shown to be characterised by an optimum focus for
which the contrast is maximum and which differs among different signals. For instance, a systematic focus
mismatch is found between images formed by high-angle scattering, being sensitive to thickness and chemical
composition, and the first moment in diffraction space, being sensitive to electric fields. It follows that a single
recording at one specific probe focus is usually insufficient to characterise materials comprehensively. Most
importantly, we demonstrate in experiment and simulation that the second moment (
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2021.113425
|
|
“Farmers' preferences towards water hyacinth control : a contingent valuation study”. Van Oijstaeijen W, Van Passel S, Cools J, Janssens de Bisthoven L, Huge J, Berihun D, Ejigu N, Nyssen J, Journal Of Great Lakes Research 46, 1459 (2020). http://doi.org/10.1016/J.JGLR.2020.06.009
Abstract: Lake Tana is the most important freshwater lake in Ethiopia. Besides pressures on water quality resulting from urbanization and deforestation, the invasion of the exotic water hyacinth (Eichhornia crassipes) poses new threats to the ecosystem. Water hyacinth, endemic to South America, is widely considered as the world's worst aquatic invasive weed. In 2011, the weed appeared on the northern shores of Lake Tana, expanding in south-eastern direction. The lake area affected by water hyacinth was last estimated in 2015 at 34,500 ha, which equals 16% of the total lake surface. In this research, the benefits of water hyacinth control and eradication for the rural population inhabiting the northern and northeastern villages bordering Lake Tana, are investigated. In the area, the population largely depends on farming and fishing. An assessment of the total economic benefit of eradication was conducted. The stakeholder-centered approach led to measuring the willingness to contribute in labor and cash terms. Results showed smallholders in the study are willing to contribute over half-a-million euros annually. Costs of management actions can be weighed to the benefits, where further research is needed on the impact on other stakeholder groups. Moreover, wetland management should advance to explore multiple pathways in an integrated approach: water hyacinth control, water hyacinth utilization and sustainable waste water management. (C) 2020 International Association for Great Lakes Research. Published by Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; Engineering Management (ENM)
Impact Factor: 2.2
DOI: 10.1016/J.JGLR.2020.06.009
|
|
“Reducing electron beam damage through alternative STEM scanning strategies, Part II: Attempt towards an empirical model describing the damage process”. Jannis D, Velazco A, Béché, A, Verbeeck J, Ultramicroscopy , 113568 (2022). http://doi.org/10.1016/j.ultramic.2022.113568
Abstract: In this second part of a series we attempt to construct an empirical model that can mimick all experimental observations made regarding the role of an alternative interleaved scan pattern in STEM imaging on the beam damage in a specific zeolite sample. We make use of a 2D diffusion model that describes the dissipation of the deposited beam energy in the sequence of probe positions that are visited during the scan pattern. The diffusion process allows for the concept of trying to ‘outrun’ the beam damage by carefully tuning the dwell time and distance between consecutively visited probe positions. We add a non linear function to include a threshold effect and evaluate the accumulated damage in each part of the image as a function of scan pattern details. Together, these ingredients are able to describe qualitatively all aspects of the experimental data and provide us with a model that could guide a further optimisation towards even lower beam damage without lowering the applied electron dose. We deliberately remain vague on what is diffusing here which avoids introducing too many sample specific details. This provides hope that the model can be applied also in sample classes that were not yet studied in such great detail by adjusting higher level parameters: a sample dependent diffusion constant and damage threshold.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
Times cited: 4
DOI: 10.1016/j.ultramic.2022.113568
|
|
“Phase offset method of ptychographic contrast reversal correction”. Hofer C, Gao C, Chennit T, Yuan B, Pennycook TJ, Ultramicroscopy , 113922 (2024). http://doi.org/10.1016/j.ultramic.2024.113922
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2024.113922
|
|
“Optimal experiment design for element specific atom counting using multiple annular dark field scanning transmission electron microscopy detectors”. Sentürk DG, De Backer A, Friedrich T, Van Aert S, Ultramicroscopy 242, 113626 (2022). http://doi.org/10.1016/j.ultramic.2022.113626
Abstract: This paper investigates the possible benefits for counting atoms of different chemical nature when analysing multiple 2D scanning transmission electron microscopy (STEM) images resulting from independent annular dark field (ADF) detector regimes. To reach this goal, the principles of statistical detection theory are used to quantify the probability of error when determining the number of atoms in atomic columns consisting of multiple types of elements. In order to apply this theory, atom-counting is formulated as a statistical hypothesis test, where each hypothesis corresponds to a specific number of atoms of each atom type in an atomic column. The probability of error, which is limited by the unavoidable presence of electron counting noise, can then be computed from scattering-cross sections extracted from multiple ADF STEM images. Minimisation of the probability of error as a function of the inner and outer angles of a specified number of independent ADF collection regimes results in optimal experimental designs. Based on simulations of spherical Au@Ag and Au@Pt core–shell nanoparticles, we investigate how the combination of two non-overlapping detector regimes helps to improve the probability of error when unscrambling two types of atoms. In particular, the combination of a narrow low angle ADF detector with a detector formed by the remaining annular collection regime is found to be optimal. The benefit is more significant if the atomic number Z difference becomes larger. In
addition, we show the benefit of subdividing the detector regime into three collection areas for heterogeneous nanostructures based on a structure consisting of three types of elements, e.g., a mixture of Au, Ag and Al atoms. Finally, these results are compared with the probability of error resulting when one would ultimately use a pixelated 4D STEM detector and how this could help to further reduce the incident electron dose.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 2.2
DOI: 10.1016/j.ultramic.2022.113626
|