“Diffusion- and velocity-driven spatial separation of analytes from single droplets entering an ICP off-axis”. Borovinskaya O, Aghaei M, Flamigni L, Hattendorf B, Tanner M, Bogaerts A, Günther D, Journal of analytical atomic spectrometry 29, 262 (2014). http://doi.org/10.1039/c3ja50307k
Abstract: The reproducible temporal separation of ion signals generated from a single multi-element droplet, observed in previous studies, was investigated in detail in this work using an ICPTOFMS with high temporal resolution. It was shown that the signal peak intensities of individual elements temporally shift relative to each other only for droplets moving through the plasma off-axis. The magnitude of these shifts correlated with the vaporization temperatures of the analytes and depended on the radial position of the droplets as well as on the thermal properties and velocity profiles of the carrier gases of the ICP. The occurrence of the signal shifting was explained by a spatial separation of analytes already present in the vapor phase in the ICP from a yet unvaporized residue of the droplet. This separation is most likely driven by anisotropic diffusion of vaporized analytes towards the plasma axis and a radial velocity gradient. The proposed explanation is supported by modeling of the gas velocities inside the ICP and imaging of the atomic and ionic emissions produced from single droplets, whose patterns were sloping towards the center of the torch. The effects observed in these studies are important not only for the fundamental understanding of analyteplasma interactions but have also a direct impact on the signal intensities and stability.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 18
DOI: 10.1039/c3ja50307k
|
“Effect of a mass spectrometer interface on inductively coupled plasma characteristics : a computational study”. Aghaei M, Lindner H, Bogaerts A, Journal of analytical atomic spectrometry 27, 604 (2012). http://doi.org/10.1039/c2ja10341a
Abstract: An inductively coupled plasma connected to a mass spectrometer interface (sampling cone) is computationally investigated. Typical plasma characteristics, such as gas flow velocity, plasma temperature and electron density, are calculated in two dimensions (cylindrical symmetry) and compared with and without a mass spectrometer sampling interface. The results obtained from our model compare favorably with experimental data reported in the literature. A dramatic increase in the plasma velocity is reported in the region close to the interface. Furthermore, a cooled metal interface lowers the plasma temperature and electron density on the axial channel very close to the sampling cone but the corresponding values in the off axial regions are increased. Therefore, the effect of the interface strongly depends on the measurement position. It is shown that even a small shift from the actual position of the sampler leads to a considerable change of the results.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 18
DOI: 10.1039/c2ja10341a
|
“The effect of the sampling cone position and diameter on the gas flow dynamics in an ICP”. Aghaei M, Lindner H, Bogaerts A, Journal of analytical atomic spectrometry 28, 1485 (2013). http://doi.org/10.1039/c3ja50107h
Abstract: An inductively coupled plasma, connected to a sampling cone of a mass spectrometer, is computationally investigated. The effects of the sampler orifice diameter (ranging from 1 to 2 mm) and distance of the sampler cone from the load coil (ranging from 7 to 17 mm) are studied. An increase in sampler orifice diameter leads to a higher central plasma temperature at the place of the sampler, as well as more efficient gas transfer through the sampler, by reducing the interaction of the plasma gas with the sampling cone. However, the flow velocity at the sampler position is found to be independent of the sampler orifice diameter. Moreover, by changing the sampler orifice diameter, we can control whether only the central gas or also the auxiliary gas can exit through the sampler. Finally, with the increasing distance of the sampler from the load coil, the plasma temperature at the place of the sampler decreases slightly, which might also have consequences for the ion generation and transport through the sampling cone.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 14
DOI: 10.1039/c3ja50107h
|
“Effects of adding hydrogen to an argon glow discharge: overview of relevant processes and some qualitative explanations”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 441 (2000). http://doi.org/10.1039/a909779a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 58
DOI: 10.1039/a909779a
|
“The glow discharge: an exciting plasma”. Bogaerts A, Journal of analytical atomic spectrometry 14, 1375 (1999). http://doi.org/10.1039/a900772e
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 29
DOI: 10.1039/a900772e
|
“Glow discharge optical emission spectrometry: moving towards reliable thin film analysis: a short review”. Angeli J, Bengtson A, Bogaerts A, Hoffmann V, Hodoroaba V-D, Steers E, Journal of analytical atomic spectrometry 18, 670 (2003). http://doi.org/10.1039/b301293j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 75
DOI: 10.1039/b301293j
|
“Hybrid Monte Carlo-fluid model for a microsecond pulsed glow discharge”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 895 (2000). http://doi.org/10.1039/b003398g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b003398g
|
“Hydrogen addition to an argon glow discharge: a numerical simulation”. Bogaerts A, Journal of analytical atomic spectrometry 17, 768 (2002). http://doi.org/10.1039/b200025c
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 48
DOI: 10.1039/b200025c
|
“Improved hybrid Monte Carlo-fluid model for the electrical characteristics in an analytical radiofrequency glow discharge in argon”. Bogaerts A, Gijbels R, Goedheer W, Journal of analytical atomic spectrometry 16, 750 (2001). http://doi.org/10.1039/b103768b
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 11
DOI: 10.1039/b103768b
|
“Laser ablation of copper in different background gases: comparative study by numerical modeling and experiments”. Bogaerts A, Chen Z, Bleiner D, Journal of analytical atomic spectrometry 21, 384 (2006). http://doi.org/10.1039/b514313f
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 67
DOI: 10.1039/b514313f
|
“Modeling of a microsecond pulsed glow discharge: behavior of the argon excited levels and of the sputtered copper atoms and ions”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 16, 239 (2001). http://doi.org/10.1039/b009289o
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 36
DOI: 10.1039/b009289o
|
“Modeling of a millisecond pulsed glow discharge: investigation of the afterpeak”. Bogaerts A, Gijbels R, Jackson GP, Journal of analytical atomic spectrometry 18, 533 (2003). http://doi.org/10.1039/b212606k
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b212606k
|
“Modeling of argon direct current glow discharges and comparison with experiment: how good is the agreement?”.Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 13, 945 (1998). http://doi.org/10.1039/a800329g
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 24
DOI: 10.1039/a800329g
|
“Modeling study on the influence of the pressure on a dielectric barrier discharge microplasma”. Martens T, Bogaerts A, Brok WJM, van der Mullen JJAM, Journal of analytical atomic spectrometry 22, 1003 (2007). http://doi.org/10.1039/b704903j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b704903j
|
“Nanosecond laser ablation of Cu: modeling of the expansion in He background gas, and comparison with expansion in vacuum”. Bogaerts A, Chen Z, Journal of analytical atomic spectrometry 19, 1169 (2004). http://doi.org/10.1039/b402946a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 39
DOI: 10.1039/b402946a
|
“Numerical simulation analysis of flow patterns and particle transport in the HEAD laser ablation cell with respect to inductively coupled plasma spectrometry”. Lindner H, Autrique D, Pisonero J, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 25, 295 (2010). http://doi.org/10.1039/b920905k
Abstract: The present study analyses a specific laser ablation cell, the High Efficiency Aerosol Dispersion (HEAD) cell (see J. Pisonero et al., J. Anal. At. Spectrom., 2006, 21, 922931), by means of computational fluid dynamics (CFD) simulations. However, this cell consists of different modular parts, therefore, the results are probably of interest for the further development of other ablation cells. In the HEAD cell, the ablation spot is positioned below an orifice in the ceiling of the sample chamber. The particle transport through this orifice has been analysed for a ceiling height of 0.8 mm. The critical velocity for the onset of particle losses was found to be independent on the ejection angle at the crater spot. The deceleration of the particles can be described as the stopping in an effectively steady gas. Particle losses were negligible in this modular part of the cell at the evaluated laser ablation conditions. The transport efficiency through the Venturi chamber was investigated for different sample gas flow rates. In this case, it was found that small particles were predominantly lost at low flow rates, the large particles at higher flow rates. Making use of the simulation results, it was possible to design a modification of the HEAD cell that results in extremely short calculated washout times. The simulations yielded a signal of less than 10 ms, which was produced by more than 99% of the introduced mass.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 16
DOI: 10.1039/b920905k
|
“Occurrence of gas flow rotational motion inside the ICP torch : a computational and experimental study”. Aghaei M, Flamigni L, Lindner H, Günther D, Bogaerts A, Journal of analytical atomic spectrometry 29, 249 (2014). http://doi.org/10.1039/c3ja50302j
Abstract: An inductively coupled plasma, connected to the sampling cone of a mass spectrometer, is computationally investigated. The occurrence of rotational motion of the auxiliary and carrier gas flows is studied. The effects of operating parameters, i.e., applied power and gas flow rates, as well as geometrical parameters, i.e., sampler orifice diameter and injector inlet diameter, are investigated. Our calculations predict that at higher applied power the auxiliary and carrier gas flows inside the torch move more forward to the sampling cone, which is validated experimentally for the auxiliary gas flow, by means of an Elan 6000 ICP-MS. Furthermore, an increase of the gas flow rates can also modify the occurrence of rotational motion. This is especially true for the carrier gas flow rate, which has a more pronounced effect to reduce the backward motion than the flow rates of the auxiliary and cooling gas. Moreover, a larger sampler orifice (e.g., 2 mm instead of 1 mm) reduces the backward flow of the auxiliary gas path lines. Finally, according to our model, an injector inlet of 2 mm diameter causes more rotations in the carrier gas flow than an injector inlet diameter of 1.5 mm, which can be avoided again by changing the operating parameters.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/c3ja50302j
|
“Plasma diagnostics and numerical simulations: insight into the heart of analytical glow discharges”. Bogaerts A, Journal of analytical atomic spectrometry 22, 13 (2007). http://doi.org/10.1039/b611436a
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 23
DOI: 10.1039/b611436a
|
“Role of laser-induced melting and vaporization of metals during ICP-MS and LIBS analysis, investigated with computer simulations and experiments”. Bleiner D, Chen Z, Autrique D, Bogaerts A, Journal of analytical atomic spectrometry 21, 910 (2006). http://doi.org/10.1039/b602800d
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 42
DOI: 10.1039/b602800d
|
“Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation”. Bogaerts A, Gijbels R, Journal of analytical atomic spectrometry 15, 1191 (2000). http://doi.org/10.1039/b000519n
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 25
DOI: 10.1039/b000519n
|
“Temporal and spatially resolved laser-scattering plasma diagnostics for the characterization of a ms-pulsed glow discharge”. Gamez G, Bogaerts A, Hieftje GM, Journal of analytical atomic spectrometry 21, 350 (2006). http://doi.org/10.1039/b511764j
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/b511764j
|
“Vibrational level population of nitrogen impurities in low-pressure argon glow discharges”. Simon P, Bogaerts A, Journal of analytical atomic spectrometry 26, 804 (2011). http://doi.org/10.1039/c0ja00179a
Abstract: The vibrational level populations of the electronic ground state of the nitrogen molecule have been calculated for typical glow discharge conditions in argonnitrogen mixtures with nitrogen concentrations between 0.1 and 1%. Stationary solutions of the master equations of the vibrational levels have been obtained using numerical methods. The main mechanisms responsible for the population and depopulation of the vibrational levels, and for the overall shape of the vibrational distribution function are pointed out. It has been found that vibrationvibration collisions play only a minor role and therefore the population of the vibrational levels is basically determined by the electron temperature.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 6
DOI: 10.1039/c0ja00179a
|
“Particle transport through an inductively coupled plasma torch: elemental droplet evaporation”. Aghaei M, Bogaerts A, Journal of analytical atomic spectrometry 31, 631 (2016). http://doi.org/10.1039/C5JA00162E
Abstract: We studied the transport of copper droplets through an inductively coupled plasma, connected to the sampling cone of a mass spectrometer, by means of a computational model. The sample droplets are followed until they become evaporated. They are inserted as liquid particles from the central inlet and the effects of injection position (i.e. “on” and “off” axis), droplet diameter, as well as mass loading flow rate are investigated. It is shown that more “on-axis” injection of the droplets leads to a more straight path line, so that the droplets move less in the radial direction and are evaporated more on the central axis, enabling a better sample transfer efficiency to the sampler cone. Furthermore, there are optimum ranges of diameters and flow rates, which guarantee the proper position of evaporation along the torch, i.e. not too early, so that the sample can get lost in the torch, and not too late, which reduces the chance of becoming ionized before reaching the sampler.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 21
DOI: 10.1039/C5JA00162E
|
“Inductively coupled plasma-mass spectrometry: insights through computer modeling”. Bogaerts A, Aghaei M, Journal of analytical atomic spectrometry 32, 233 (2017). http://doi.org/10.1039/C6JA00408C
Abstract: In this tutorial review paper, we illustrate how computer modeling can contribute to a better insight in inductively coupled plasma-mass spectrometry (ICP-MS). We start with a brief overview on previous efforts, studying the fundamentals of the ICP and ICP-MS, with main focus on previous modeling activities. Subsequently, we explain in detail the model that we developed in previous years, and we show typical calculation results, illustrating the plasma characteristics, gas flow patterns and the sample transport, evaporation and ionization. We also present the effect of various experimental parameters, such as operating conditions, geometrical aspects and sample characteristics, to illustrate how modeling can help to elucidate the optimal conditions for improved analytical performance.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.379
Times cited: 14
DOI: 10.1039/C6JA00408C
|
“A 2D model for a gliding arc discharge”. Kolev S, Bogaerts A, Plasma sources science and technology 24, 015025 (2015). http://doi.org/10.1088/0963-0252/24/1/015025
Abstract: In this study we report on a 2D fluid model of a gliding arc discharge in argon. Despite the 3D nature of the discharge, 2D models are found to be capable of providing very useful information about the operation of the discharge. We employ two modelsan axisymmetric and a Cartesian one. We show that for the considered experiment and the conditions of a low current arc (around 30 mA) in argon, there is no significant heating of the cathode surface and the discharge is sustained by field electron emission from the cathode accompanied by the formation of a cathode spot. The obtained discharge power and voltage are relatively sensitive to the surface properties and particularly to the surface roughness, causing effectively an amplification of the normal electric field. The arc body and anode region are not influenced by this and depend mainly on the current value. The gliding of the arc is modelled by means of a 2D Cartesian model. The arcelectrode contact points are analysed and the gliding mechanism along the electrode surface is discussed. Following experimental observations, the cathode spot is simulated as jumping from one point to another. A complete arc cycle is modelled from initial ignition to arc decay. The results show that there is no interaction between the successive gliding arcs.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 34
DOI: 10.1088/0963-0252/24/1/015025
|
“Characterization of an Ar/O2 magnetron plasma by a multi-species Monte Carlo model”. Bultinck E, Bogaerts A, Plasma sources science and technology 20, 045013 (2011). http://doi.org/10.1088/0963-0252/20/4/045013
Abstract: A combined Monte Carlo (MC)/analytical surface model is developed to study the plasma processes occurring during the reactive sputter deposition of TiOx thin films. This model describes the important plasma species with a MC approach (i.e. electrons, Ar+ ions, {\rm O}_2
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 7
DOI: 10.1088/0963-0252/20/4/045013
|
“Comprehensive modelling network for dc glow discharges in argon”. Bogaerts A, Plasma sources science and technology 8, 210 (1999). http://doi.org/10.1088/0963-0252/8/2/003
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 27
DOI: 10.1088/0963-0252/8/2/003
|
“Computer simulations of an oxygen inductively coupled plasma used for plasma-assisted atomic layer deposition”. Tinck S, Bogaerts A, Plasma sources science and technology 20, 015008 (2011). http://doi.org/10.1088/0963-0252/20/1/015008
Abstract: In this paper, an O2 inductively coupled plasma used for plasma enhanced atomic layer deposition of Al2O3 thin films is investigated by means of modeling. This work intends to provide more information about basic plasma properties such as species densities and species fluxes to the substrate as a function of power and pressure, which might be hard to measure experimentally. For this purpose, a hybrid model developed by Kushner et al is applied to calculate the plasma characteristics in the reactor volume for different chamber pressures ranging from 1 to 10 mTorr and different coil powers ranging from 50 to 500 W. Density profiles of the various oxygen containing plasma species are reported as well as fluxes to the substrate under various operating conditions. Furthermore, different orientations of the substrate, which can be placed vertically or horizontally in the reactor, are taken into account. In addition, special attention is paid to the recombination process of atomic oxygen on the different reactor walls under the stated operating conditions. From this work it can be concluded that the plasma properties change significantly in different locations of the reactor. The plasma density near the cylindrical coil is high, while it is almost negligible in the neighborhood of the substrate. Ion and excited species fluxes to the substrate are found to be very low and negligible. Finally, the orientation of the substrate has a minor effect on the flux of O2, while it has a significant effect on the flux of O. In the horizontal configuration, the flux of atomic oxygen can be up to one order of magnitude lower than in the vertical configuration.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 11
DOI: 10.1088/0963-0252/20/1/015008
|
“Conversion of carbon dioxide to value-added chemicals in atmospheric pressure dielectric barrier discharges”. Paulussen S, Verheyde B, Tu X, De Bie C, Martens T, Petrovic D, Bogaerts A, Sels B, Plasma sources science and technology 19, 034015 (2010). http://doi.org/10.1088/0963-0252/19/3/034015
Abstract: The aim of this work consists of the evaluation of atmospheric pressure dielectric barrier discharges for the conversion of greenhouse gases into useful compounds. Therefore, pure CO2 feed flows are administered to the discharge zone at varying discharge frequency, power input, gas temperature and feed flow rates, aiming at the formation of CO and O2. The discharge obtained in CO2 is characterized as a filamentary mode with a microdischarge zone in each half cycle of the applied voltage. It is shown that the most important parameter affecting the CO2-conversion levels is the gas flow rate. At low flow rates, both the conversion and the CO-yield are significantly higher. In addition, also an increase in the gas temperature and the power input give rise to higher conversion levels, although the effect on the CO-yield is limited. The optimum discharge frequency depends on the power input level and it cannot be unambiguously stated that higher frequencies give rise to increased conversion levels. A maximum CO2 conversion of 30% is achieved at a flow rate of 0.05 L min−1, a power density of 14.75 W cm−3 and a frequency of 60 kHz. The most energy efficient conversions are achieved at a flow rate of 0.2 L min−1, a power density of 11 W cm−3 and a discharge frequency of 30 kHz.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 116
DOI: 10.1088/0963-0252/19/3/034015
|
“Dielectric barrier discharges used for the conversion of greenhouse gases: modeling the plasma chemistry by fluid simulations”. De Bie C, Martens T, van Dijk J, Paulussen S, Verheyde B, Corthals S, Bogaerts A, Plasma sources science and technology 20, 024008 (2011). http://doi.org/10.1088/0963-0252/20/2/024008
Abstract: The conversion of methane to value-added chemicals and fuels is considered to be one of the challenges of the 21st century. In this paper we study, by means of fluid modeling, the conversion of methane to higher hydrocarbons or oxygenates by partial oxidation with CO2 or O2 in a dielectric barrier discharge. Sixty-nine different plasma species (electrons, ions, molecules, radicals) are included in the model, as well as a comprehensive set of chemical reactions. The calculation results presented in this paper include the conversion of the reactants and the yields of the reaction products as a function of residence time in the reactor, for different gas mixing ratios. Syngas (i.e. H2 + CO) and higher hydrocarbons (C2Hx) are typically found to be important reaction products.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 3.302
Times cited: 38
DOI: 10.1088/0963-0252/20/2/024008
|