|
“TEM investigation of SCC crack tips in high Si stainless steel tapered specimens”. Penders A, Konstantinovic MJ, Van Renterghem W, Bosch RW, Schryvers D, Corrosion Engineering Science And Technology (2021). http://doi.org/10.1080/1478422X.2021.1961665
Abstract: The stress corrosion cracking (SCC) mechanism is investigated in high Si duplex stainless steel in a simulated PWR environment based on TEM analysis of FIB-extracted SCC crack tips. The microstructural investigation in the near vicinity of SCC crack tips illustrates a strain-rate dependence in SCC mechanisms. Detailed analysis of the crack tip morphology, that includes crack tip oxidation and surrounding deformation field, indicates the existence of an interplay between corrosion- and deformation-driven failure as a function of the strain rate. Slow strain-rate crack tips exhibit a narrow cleavage failure which can be linked to the film-induced failure mechanism, while rounded shaped crack tips for faster strain rates could be related to the strain-induced failure. As a result, two nominal strain-rate-dependent failure regimes dominated either by corrosion or deformation-driven cracking mechanisms can be distinguished.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 0.879
DOI: 10.1080/1478422X.2021.1961665
|
|
|
“Composition gradients surrounding Ni4Ti3 precipitates in a NiTi alloy studied by EELS, EFTEM and EDX”. Yang Z, Schryvers D, International journal of applied electromagnetics and mechanics 23, 17 (2006)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.769
|
|
|
“FCC surface precipitation in Cu-Zn-Al after low angle GA+ ion irradiation”. Zelaya E, Schryvers D, Materials transactions 51, 2177 (2010). http://doi.org/10.2320/matertrans.M2010171
Abstract: The precipitation of a disordered FCC surface structure after low angle Ga+ ion irradiation during focused ion beam thinning of a B2 Cu-Zn-Al alloy with e/a=1.48 is reported. Conventional as well as high-resolution transmission electron microscopy techniques reveal FCC layers on both sides of the thinned sample. The occurrence of this structure is attributed to disordering and dezincification of the alloy resulting from the sputtering process during the irradiation. Changes in crystallographic sample orientation with respect to the incoming ion beam do not have a significant effect on the appearance of the FCC surface structure.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.713
Times cited: 2
DOI: 10.2320/matertrans.M2010171
|
|
|
“Microstructure of a partially crystallised Ti50Ni25Cu25 melt-spun ribbon”. Santamarta R, Schryvers D, Materials transactions 44, 1760 (2003). http://doi.org/10.2320/matertrans.44.1760
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.713
Times cited: 23
DOI: 10.2320/matertrans.44.1760
|
|
|
“R-phase structure refinement using electron diffraction data”. Schryvers D, Potapov PL, Materials transactions 43, 774 (2002). http://doi.org/10.2320/matertrans.43.774
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.713
Times cited: 25
DOI: 10.2320/matertrans.43.774
|
|
|
“A comparative investigation of replication techniques used for the study of (S+Au) sensitized AgBr microcrystals”. Buschmann V, Schryvers D, van Landuyt J, van Roost C, de Keyzer R, The journal of imaging science and technology 40, 189 (1996)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.349
Times cited: 4
|
|
|
“The influence of crystal thickness on the image tone”. van Renterghem W, Schryvers D, van Landuyt J, van Roost C, de Keyzer R, Journal of imaging science 47, 133 (2003)
Abstract: It is known that the neutral image tone of a developed photographic film becomes brownish when the thickness of the original silver halide tabular crystals is reduced. We investigate by electron microscopy to what extent the silver filament structure has changed and how it induces the shift in image tone. Therefore, two samples of AgBr {111} tabular crystals with average thicknesses of 160 nm and 90 nm respectively, are compared. It is shown that the dimensions and defect structure of the filaments are comparable, but that the 90 nm crystals result in a more widely spaced structure, which explains the shift in image tone on a qualitative level. The influence of the addition of an image toner, i.e., phenylmercaptotetrazole, on the filament structure is also investigated. An even more open filament structure of longer, but smaller filaments was observed.
Keywords: A1 Journal article; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
Impact Factor: 0.348
|
|
|
“Influence of twinning on the morphology of AgBr and AgCl microcrystals”. van Renterghem W, Goessens C, Schryvers D, van Landuyt J, Bollen D, de Keyzer R, van Roost C, The journal of imaging science and technology 45, 349 (2001)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.348
|
|
|
“Microstructural mechanism of development in photothermographic materials”. Potapov PL, Schryvers D, Strijckers H, van Roost C, The journal of imaging science and technology 47, 115 (2003)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.348
|
|
|
“New method to determine the parity of the number of twin planes in tabular silver halide microcrystals from top views”. Goessens C, Schryvers D, van Landuyt J, de Keyzer R, The journal of imaging science and technology 41, 301 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.348
Times cited: 1
|
|
|
“A TEM study of non-parallel twins inducing thickness growth in silver chloride {111} tabular crystals”. van Renterghem W, Schryvers D, van Landuyt J, Bollen D, van Roost C, de Keyzer R, The journal of imaging science and technology 45, 83 (2001)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 0.348
|
|
|
“3D FIB/SEM study of Ni4Ti3 precipitates in Ni-Ti alloys with different thermal-mechanical histories”. Cao S, Nishida M, Somsen C, Eggeler G, Schryvers D, , 02004 (2009). http://doi.org/10.1051/esomat/200902004
Abstract: The three-dimensional size, morphology and distribution of Ni4Ti3 precipitates growing in binary Ni-rich Ni-Ti alloys have been investigated via a slice view procedure in a Dual-Beam FIB/SEM system, in order to better stress-free Ni50.8Ti49.2 alloy with all four variants of precipitates and a compressed Ni51Ti49 alloy with aligned precipitates in one family were studied. The Ni4Ti3 precipitates reach a volume fraction of 9.6% in the reconstructed region of the stress-free alloy and 4.3% in the compressed one. In both cases, the mean volume, specific surface area, sphericity and aspect ratio of the precipitates are calculated and the Pair Distribution Functions of the precipitates are obtained. It is shown that most precipitates in the stress-free sample grow larger and have a more lenticular shape, while those in the compressed sample are more cylindrical. Deviations from these ideal shapes reveal internal steps in the stress-free sample and lamellae formation in the compressed one.
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
Times cited: 1
DOI: 10.1051/esomat/200902004
|
|
|
“3D reconstruction of a Ni51Ti49 alloy with precipitates by FIB-SEM alice-and-view”. Cao S, Tirry W, Schryvers D, Materia Japan 46, 803 (2007)
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT)
|
|
|
“3D reconstruction of Ni4Ti3 precipitates in a Ni51Ti49 alloy in a FIB/SEM dual-beam system”. Cao S, Tirry W, van den Broek W, Schryvers D, Materials science forum 583, 277 (2008). http://doi.org/10.4028/www.scientific.net/MSF.583.277
Abstract: Ni4Ti3 precipitates play an important role in the shape memory and superelastic behaviour of thermo-mechanically treated Ni-Ti material. The 3D morphology and distribution of such precipitates with lenticular shape and rhombohedral atomic structure in the austenitic B2 matrix of a binary Ni-rich Ni-Ti alloy has been elucidated via a slice view procedure in a Dual-Beam FIB/SEM system. With the sequence of cross-section SE images obtained from the SEM, a 3D reconstruction has been achieved after proper alignment and image processing, from which both qualitative and quantitative analysis can be performed. Careful imaging is needed to ensure that all variants of the precipitates are observed with equal probability, regardless sample orientation. Moreover, due to the weak contrast of the precipitates, proper imaging conditions need to be selected to allow for semi-automated image treatment. Finally, a volume ratio of 10.2% for the Ni4Ti3 precipitates could be calculated, summed over all variants, which yields a net composition of Ni50.36Ti49.64 for the matrix, leading to an increase of 113 degrees for the martensitic start temperature Ms. Also, the expected relative orientation of the different variants of the precipitates could be confirmed. In the near future, other quantitative measures on the distribution of the precipitates can be expected.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
DOI: 10.4028/www.scientific.net/MSF.583.277
|
|
|
“3D strain fields surrounding Ni4Ti3: direct measurement and correlation with the R-phase”. Tirry W, Schryvers D, , 02032 (2009). http://doi.org/10.1051/esomat/200902032
Abstract: Strain fields introduced by coherent Ni4Ti3 precipitates in austenitic Ni-Ti are believed to be a possible origin of why the R-phase transformation is introduced as an extra step before transforming to the B19'. The presence of this strain field was already confirmed in the past by conventional transmission electron microscopy (TEM) techniques and measured quantitatively by high resolution TEM (HRTEM). This time the geometrical phase method is applied on HRTEM micrographs to measure the full 3D strain tensor of the strain fields. Since each atomic resolution micrograph only results in a 2D measurement of the strain, observations in two different zone orientations are combined to retrieve the 3 x 3 strain tensor. In this work observations in a [1-1 1](B2) and [1 0-1](B2) zone orientation are used and this in case of precipitates with a diameter of around 50nm. In a next step the measured strain tensor is compared to the calculated eigenstrain of the R-phase in reference to the B2 matrix. This comparison shows that the introduced strain is very similar to the eigenstrain of one R-phase variant. Since for both structures, Ni4Ti3 and R-phase, four orientation variants are possible, each variant of the R-phase is thus able to accommodate the strain field of one of the Ni4Ti3 variants.
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
DOI: 10.1051/esomat/200902032
|
|
|
“Advanced electron microscopy characterisation of important precipitation and ordering phenomena in shape memory systems”. Schryvers D, Shape memory and superelasticity 1, 78 (2015). http://doi.org/10.1007/s40830-015-0006-3
Abstract: The present paper discusses some important aspects of precipitation and ordering in alloy systems that show a martensitic transformation and can or are used as shape memory or superelastic metallic systems. The precipitates are investigated by a variety of conventional and advanced electron microscopy techniques, including atomic resolution, 3D slice-and-view, energy loss spectroscopy etc. Depending on the system, such secondary phases can decrease the probability of a displacive transformation by changing the phase stability in the system, such as in the case of NiAl or NiTiPd, or can mechanically hinder the passage of the transformation interface, as in NiTiNb. On the other hand, properly controlling the nucleation and growth of some precipitates can strongly improve the properties of some types of materials, as is the case for the well-known Ni4Ti3 precipitates.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
DOI: 10.1007/s40830-015-0006-3
|
|
|
“Advanced TEM and SEM methods applied to 3D nano- and microstructural investigations of Ni4Ti3 precipitates in Ni-Ti (SMA)”. Schryvers D, Tirry W, Cao S, Diffusion and defect data : solid state data : part B : solid state phenomena 172/174, 229 (2011). http://doi.org/10.4028/www.scientific.net/SSP.172-174.229
Abstract: Two different kinds of experimental approaches yielding three-dimensional structural information on metastable semi-coherent precipitates are demonstrated. By combining high-resolution images from two independent viewing directions a full description of the strain field surrounding a nano-sized Ni4Ti3 precipitate in Ni-Ti can be obtained. The principal axes and strains correlate well with the transformation strain of the observed R-phase transformation close to the precipitate. Using a slice-and-view procedure in a FIB/SEM dual-beam instrument, a three-dimensional voxel dataset is produced from which morphological and distributional information on the same precipitates can be obtained yielding new insight into the particular transformation paths of these alloys, relevant for their functional behaviour.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
DOI: 10.4028/www.scientific.net/SSP.172-174.229
|
|
|
“Advanced TEM investigations on Ni-Ti shape memory material: strain and concentration gradients surrounding Ni4Ti3 precipitates”. Schryvers D, Tirry W, Yang Z, , 329 (2005)
Abstract: Lattice deformations and concentration gradients surrounding Ni4Ti3 precipitates grown by appropriate annealing in a Ni51Ti49 B2 austenite matrix are determined by a combination of TEM techniques. Quantitative Fourier analysis of HRTEM images reveals a deformed nanoscale region with lattice deformations up to 2% while EELS and EDX indicate a Ni depleted zone up to 150 nm away from the matrix-precipitate interface.
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Advanced TEM studies of martensite and related phase transformations”. Schryvers D s.l., page 947 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“The application of transmission electron microscopy (TEM) in the research of inorganic colorants in stained glass windows and parchment illustrations”. Fredrickx P, Wouters J, Schryvers D Archetype, London, page 137 (2003).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Atomic scale characterization of supported and assembled nanoparticles”. Pauwels B, Yandouzi M, Schryvers D, Van Tendeloo G, Verschoren G, Lievens P, Hou M, van Swygenhoven H, , B8.3 (2001)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Atomic scale modeling of supported and assembled nanoparticles”. Zhurkin E, Hou M, van Swygenhoven H, Pauwels B, Yandouzi M, Schryvers D, Van Tendeloo G, Lievens P, Verschoren G, Kuriplach J, van Peteghem S, Segers D, Dauwe C, , B8.2 (2001)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Atomic structure of alloys close to phase transitions”. Van Tendeloo G, Schryvers D, Nucleation and growth processes in materials 580, 283 (2000)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
|
|
|
“Conventional and HREM study of structural defects in nanostructured silver halides”. Schryvers D, Goessens C, van Renterghem W, van Landuyt J, de Keyzer R, , 1 (1998)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Decomposition of a metastable bcc phase in rapidly solidified Ni-9 at.% Zr and Ni-8 at.%X alloys”. Chandrasekaran M, Ghosh G, Schryvers D, de Graef M, Delaey L, Van Tendeloo G, Philosophical magazine: A: physics of condensed matter: defects and mechanical properties 75, 677 (1997)
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 5
|
|
|
“Decomposition phenomena in Ni-Mn-Ti austenite”. Schryvers D, Seo JW, Richard O, Vermeulen W, Potapov P s.l., page 887 (1999).
Keywords: H1 Book chapter; Electron microscopy for materials research (EMAT)
|
|
|
“Defect induced thickness growth in silver chloride (111) tabular crystals: a TEM study”. Van Renterghem W, Schryvers D, van Landuyt J, Bollen D, Van Roost C, De Keyzer RB, , 38 (2000)
Abstract: Defects in AgG tabular crystals with {111} surfaces are characterised by transmission electron microscopy (TEM) and their influence on the growth process is discussed. In the tabular crystals, twins parallel to the tabular face as well as dislocations along different directions are observed. The twins induce the tabular growth, while the dislocations do not influence the morphology. In 10 to 30% of the crystals that have been characterised, thickness growth is observed and it is shown that in all cases twins on other planes than the tabular ones are present. Two configurations occur more frequently and are analysed in detail. For the first group, twins parallel to the tabular face as well as a microtwin along a non-parallel {111} plane and ending inside the crystal are present. In the crystals of the second group only one extra non-parallel twin occurs giving rise to a bicrystal built up by a tetrahedral shaped part and a flat triangular or trapezoidal part. More complex twin configurations give rise to various, less characteristic morphologies.
Keywords: P1 Proceeding; Engineering sciences. Technology; Electron microscopy for materials research (EMAT)
|
|
|
“Defect related growth of tabular AgCl(100) crystals: a TEM study”. van Renterghem W, Schryvers D, van Landuyt J, van Roost C, , 389 (1998)
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
|
|
|
“Defect structures in CuZr martensite, studies by CTEM and HRTEM”. Seo JW, Schryvers D, Journal de physique: 4 C5, 149 (1997). http://doi.org/10.1051/jp4:1997523
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Times cited: 1
DOI: 10.1051/jp4:1997523
|
|
|
“Defects in AgCl and AgBr(100) tabular crystals studied by TEM”. van Renterghem W, Goessens C, Schryvers D, van Landuyt J, Verrept P, Bollen D, van Roost C, de Keyzer R, , 6 (1998)
Keywords: P3 Proceeding; Electron microscopy for materials research (EMAT)
|
|