“Single particle characterisation of inorganic suspension in Lake Baikal”. Jambers W, Van Grieken R, Environmental science and technology 31, 1525 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace elements in the atmospheric aerosols and soils in and around Recife, N.E. Brasil”. Costa Dantas C, Moura de Amorim W, Van 't dack L, Van Grieken R, Ciencia e cultura 32, 1525 (1980)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Determination of low-Z elements in individual environmental particles using windowless EPMA”. Ro C-U, Osán J, Van Grieken R, Analytical chemistry 71, 1521 (1999). http://doi.org/10.1021/AC981070F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC981070F
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
“Gypsum and other calcium-rich particles above the North Sea”. Hoornaert S, van Malderen H, Van Grieken R, Environmental science and technology 30, 1515 (1996). http://doi.org/10.1021/ES9504350
Abstract: Ca-containing particles, especially CaSO4 particles, have been encountered in several atmospheric aerosol studies. An overview is given of the different sources of airborne Ca-containing particles, The North Sea atmosphere is studied to identify the different Ca-containing particle types and to find the correlation between their occurrence and the source regions of the corresponding air masses. About 50000 individual aerosol samples were collected above the Southern Eight of the North Sea for several wind directions and analyzed for their composition using electron probe X-ray microanalysis. Nonhierarchical cluster analysis is performed on the data to reveal the different particle types, their relative abundances and their sources. CaSO4 in most cases constitutes the largest fraction of the Ca-containing particles. Extremely high numbers of CaSO4 particles are found for northeastern winds, coming from the central part of Germany, suggesting that a great fraction is derived from anthropogenic sources located in this region. Among the other Ca-containing particle types are the aluminosilicates, CaCO3, Fe-Ca-rich particles, and CaSO4 or CaCO3 in combination with NaCl.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES9504350
|
“Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments”. Horemans B, Van Grieken R, Atmospheric environment : an international journal 44, 1497 (2010). http://doi.org/10.1016/J.ATMOSENV.2010.01.010
Abstract: Thoracic (PM10), fine thoracic (PM2.5) and sub-micrometer (PM1) airborne particulate matter was sampled during day and night. In total, about 100 indoor and outdoor samples were collected for each fraction at ten different office environments. Energy-dispersive X-ray fluorescence spectrometry and ion chromatography were applied for the quantification of some major and minor elements and ions in the collected aerosols. During daytime, mass concentrations were in the ranges: 1129, 8.124, and 6.618 μg m−3, with averages of 20 ± 1, 15.0 ± 0.9, and 11.0 ± 0.8 μg m−3, respectively. At night, mass concentrations were found to be significantly lower for all fractions. Indoor PM1 concentrations exceeded the corresponding outdoor levels during office hours and were thought to be elevated by office printers. Particles with diameters between 1 and 2.5 μm and 2.5 and 10 μm were mainly associated with soil dust elements and were clearly subjected to distinct periods of settling/resuspension. Indoor NO3 − levels were found to follow specific microclimatic conditions at the office environments, while daytime levels of sub-micrometer Cl− were possibly elevated by the use of Cl-containing cleaning products. Indoor carbon black concentrations were sometimes as high as 22 μg m−3 and were strongly correlated with outdoor traffic conditions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2010.01.010
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
“Optimization of measurement conditions of an energy dispersive X-ray fluorescence spectrometer with high-energy polarized beam excitation for analysis of aerosol filters”. Spolnik Z, Belikov K, van Meel K, Adriaenssens E, de Roeck F, Van Grieken R, Applied spectroscopy 59, 1465 (2005). http://doi.org/10.1366/000370205775142647
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370205775142647
|
“Particulate matter analysis at elementary schools in Curitiba, Brazil”. Avigo D, Godoi AFL, Janissek PR, Makarovska Y, Krata A, Potgieter-Vermaak S, Alfoldy B, Van Grieken R, Godoi RHM, Analytical and bioanalytical chemistry 391, 1459 (2008). http://doi.org/10.1007/S00216-008-2031-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-008-2031-Y
|
“Composition of individual aerosol particles above Lake Baikal, Siberia”. van Malderen H, Van Grieken R, Khodzher T, Obolkin V, Potemkin V, Atmospheric environment : an international journal 30, 1453 (1996). http://doi.org/10.1016/1352-2310(95)00430-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/1352-2310(95)00430-0
|
“Characterization of indoor and outdoor atmospheric pollutants impacting architectural monuments : the case of San Jerónimo Monastery (Granada, Spain)”. Kontozova-Deutsch V, Cardell carolina, Urosevic M, Ruiz-Agudo E, Deutsch F, Van Grieken R, Environmental earth sciences 63, 1433 (2011). http://doi.org/10.1007/S12665-010-0657-5
Abstract: Indoor and outdoor concentrations of atmospheric gaseous pollutants as well as composition, size, and morphology of particulate matter have been investigated at the monastery of San Jerónimo in Granada (Southern Spain). Complementary micro- and nano-analytical techniques were applied; elemental and mineralogical composition and morphological characteristics of particulate matter were investigated combining electron probe microanalysis at the single particle level, and bulk aerosol samples were analyzed using energy-dispersive X-ray fluorescence, X-ray diffraction, scanning electron microscopy with energy-dispersive X-ray analyzer and transmission electron microscopy (TEM). Microclimatic conditions at the monastery were monitored, and gas concentrations were assessed by means of diffusion tubes subsequently analyzed with ion chromatography. Results revealed high abundances of soil dust particles (aluminosilicates, calcite, dolomite, quartz), salt aerosols (chlorides, sulfates and ammonium-rich salts), and NO2 and SO2 both outdoors and indoors. Amorphous black carbon particles had surprisingly high abundances for Granada, a non-industrialized city. The composition of indoor particles corresponds to severe weathering affecting the construction materials and artworks inside the church; moreover their composition promotes a feedback process that intensifies the deterioration. Chemical reactions between chloride-rich salts and pigments from paintings were confirmed by TEM analyses. Indoors, blackening of surface decorative materials is fostered by particle re-suspension due to cleaning habits in the monastery (i.e. dusting). This is the first air quality study performed in a monument in the city of Granada with the aim of developing a strategy for preventive conservation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S12665-010-0657-5
|
“Single-particle characterization of four “Asian Dust&rdquo, samples collected in Korea, using low-Z particle electron probe X-ray microanalysis”. Ro C-U, Hwang H, Kim HK, Chun Y, Van Grieken R, Environmental science and technology 39, 1409 (2005). http://doi.org/10.1021/ES049772B
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES049772B
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
“Argentinean prehistoric pigments' study by combined SEM/EDX and molecular spectroscopy”. Darchuk L, Tsybrii Z, Worobiec A, Vázquez C, Palacios OM, Stefaniak EA, Gatto Rotondo G, Sizov F, Van Grieken R, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 75, 1398 (2010). http://doi.org/10.1016/J.SAA.2010.01.006
Abstract: Composition of the prehistoric pigments (from Carriqueo rock shelter, Rio Negro province, Argentina) has been analysed by means of molecular spectroscopy (Fourier transform infrared (FTIR) and micro-Raman) and scanning electron microscopy (SEM) coupled to an energy-dispersive X-ray spectrometer (EDS). Red and yellow pigments were recognized as red and yellow ochre. The matrix of the pigments is composed of one or more substances. According to the matrix composition yellow and red pigments were also divided into two groupsi.e. those containing kaolinite or sulphates. Green pigment was detected as green earth, made up of celadonite as a chromophore.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.SAA.2010.01.006
|
“Effects of titanium dioxide industry waste dumping on sea water chemistry”. Roekens EJ, Van Grieken RE, Water research 17, 1385 (1983). http://doi.org/10.1016/0043-1354(83)90268-3
Abstract: An investigation was made to determine the influence of the dumping of a 1000 ton day−1, on the average, of acid-iron waste from the titanium dioxide industry into the shallow but turbulent Southern Bight of the North Sea. This waste contains some 20% sulfuric acid and 2% iron. After the passage of the barge that discharges 10 ton of waste min−1 into its wake, the vertical and horizontal distributions of the pH, iron-concentration and turbidity were measured as a function of time. It appeared that a few seconds after the discharge and for a very brief period, the pH was down to approx. 4 and the Fe-concentration was 13 mg l−1. More than 1 min after the discharge a pH below 6 and an iron-level above 3 mg l−1 could not be detected anywhere. The measured factor for waste dilution by sea water, based on the observed acid and iron concentration in the waste and in the discharge track, were around 5000 after 5 min, 9000 after 10 min and 80,000 after 20 min. Before and long after the dumping, the total iron-concentration in this Southern Bight area was around 100 μg l−1, but this high level might be due to natural causes.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0043-1354(83)90268-3
|
“Embedded ion exchange beads as standards for laser microprobe mass analysis of biological specimens”. Verbueken AH, Van Grieken RE, Paulus GJ, De Bruijn WC, Analytical chemistry 56, 1362 (1984). http://doi.org/10.1021/AC00272A036
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00272A036
|
“Chelex-100 ion-exchange filter membranes for preconcentration in x-ray-fluorescence analysis of water”. Van Grieken RE, Bresseleers CM, Vanderborght BM, Analytical chemistry 49, 1326 (1977). http://doi.org/10.1021/AC50017A011
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50017A011
|
“An expert system for chemical speciation of individual particles using low-Z particle electron probe X-ray microanalysis data”. Ro C-U, Kim HK, Van Grieken R, Analytical chemistry 76, 1322 (2004). http://doi.org/10.1021/AC035149I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC035149I
|
“Absorption correction in electron probe x-ray microanalysis of thin samples”. Markowicz AA, Storms HM, Van Grieken RE, Analytical chemistry 58, 1282 (1986). http://doi.org/10.1021/AC00298A003
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC00298A003
|
“Characterization of airborne particulate matter collected over the North Sea”. Rojas CM, Otten PM, Van Grieken RE, Journal of aerosol science 20, 1257 (1989). http://doi.org/10.1016/0021-8502(89)90811-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0021-8502(89)90811-2
|
“The shielding effect of the protective glazing of historical stained glass windows from an atmospheric chemistry perspective: case study Sainte Chapelle, Paris”. Godoi RHM, Kontozova V, Van Grieken R, Atmospheric environment : an international journal 40, 1255 (2006). http://doi.org/10.1016/J.ATMOSENV.2005.10.033
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2005.10.033
|
“Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent”. György K, Ajtony Z, van Meel K, Van Grieken R, Czitrovszky A, Bencs L, Talanta : the international journal of pure and applied analytical chemistry 85, 1253 (2011). http://doi.org/10.1016/J.TALANTA.2011.05.028
Abstract: A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO3) and bismuth tellurite (Bi2TeO5) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl4) was dispensed with a conventional autosampler into the graphite tube. The CCl4 was partially dried at 80 °C under the mini-flow (40 cm3 min−1) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 19002100 °C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100 °C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L−1 for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L−1 were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol−1 Er and 11 μmol mol−1 Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2011.05.028
|
“Characterization of black volcanites from the Limay river basin, Patagonia, Argentina, using energy dispersive X-ray fluorescence spectrometry : an aid to infer human group mobility”. Palacios OM, van Meel K, Van Grieken R, Marcó, P L-M, Vázquez C, Journal of radioanalytical and nuclear chemistry 298, 1245 (2013). http://doi.org/10.1007/S10967-013-2600-1
Abstract: The investigation of hunter-gatherers archaeological sites in the Limay river basin, Patagonia, Argentina, raised questions concerning the lithic technology. The chemical characterization of artifacts, rocks and possible sources of provenances could help to elucidate the hunter-gatherer mobility. In three archaeological sitesRincón Chico 2 (RCh2/87; 14C 710 ± 60 BP), Cueva Traful I (CTI; 14C 9430 ± 230 BP) and Casa de Piedra de Ortega (CPO; 14C 2840 ± 80 BP), tools and debitage or discarded flakes made in black volcanic rock have been found. Nearby an extensive rock outcrop of black volcanite, Paso Limay quarry (CPL), with similar characteristics was located. Samples coming from these four sites were analyzed by energy dispersive X-ray fluorescence spectrometry. This characterization allowed the geochemical classification of the lithic material and to correlate the samples with the suspected source after a previous statistical analysis. The majority of the samples were classified as dacites and rhyolites. Only samples coming from CPO site, the closest place to CPL were made exclusively with the quarry rocks. A set of five samples from RCh2/87 and two samples from CTI appear to have same chemical composition as CPL in spite of this site is placed in the opposite bank of the Limay river suggesting that hunter-gatherers could accede to the quarry, eventually. Finally, only a set of five samples coming from RCh2/87 and CTI do not group with the quarry. This fact evidences the existence of secondary sources of supply. The information of this research allowed inferring ancient human mobility patterns in the region.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10967-013-2600-1
|
“Enhancement of electron-induced X-ray intensity for single particles under grazing-exit conditions”. Tsuji K, Spolnik Z, Wagatsuma K, Zhang J, Van Grieken RE, Spectrochimica acta: part B : atomic spectroscopy 54, 1243 (1999). http://doi.org/10.1016/S0584-8547(99)00073-7
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00073-7
|
“Electron microprobe characterization of individual aerosol particles collected by aircraft above the Southern Bight of the North Sea”. Rojas CM, Van Grieken RE, Atmospheric environment : an international journal 26a, 1231 (1992). http://doi.org/10.1016/0960-1686(92)90384-W
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0960-1686(92)90384-W
|
“Particulate matter and gaseous pollutants in residences in Antwerp, Belgium”. Stranger M, Potgieter-Vermaak SS, Van Grieken R, The science of the total environment 407, 1182 (2009). http://doi.org/10.1016/J.SCITOTENV.2008.10.019
Abstract: This comprehensive study, a first in Flanders, Belgium, aimed at characterizing the residential indoor air quality of subgroups that took part in the European Community Respiratory Health Survey (ECRHS I1991 and ECHRS II1996) questionnaire-based asthma and related illnesses studies. This pilot study aimed at the evaluation of particulate matter and various inorganic gaseous compounds in residences in Antwerp. In addition personal exposure to the gaseous compounds of one individual per residence was assessed. The main objective was to obtain some base-line pollutant levels and compare these with studies performed in other cities, to estimate the indoor air quality in residences in Antwerp. Correlations between the various pollutant levels, indoor:outdoor ratios and the micro-environments of each residence were investigated. This paper presents results on indoor and ambient PM1, PM2.5 and PM10 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S and Cl and the water-soluble ionic concentrations in terms of SO42−, NO32−, Cl−, NH4+ K+, Ca2+. In addition, indoor, ambient and personal exposure levels of the gases NO2, SO2, and O3 were determined. Elevated indoor:outdoor ratios were found for NO2 in residences containing gas stoves. In smoker's houses increased PM concentrations of 58 and 43% were found for the fine and coarse fractions respectively. Contrary to the fact that all I/O ratios of the registered elements in each individual house were significantly correlated to each other, no correlation could be established between the I/O ratios of the different houses, thus indicating a unique micro-environment for each residence. Linear relationships between the particulate matter elemental composition, SO2 and O3 levels indoors and outdoors could be established. No linear relationships between indoor and outdoor NO2 and particulate mass concentrations were found.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SCITOTENV.2008.10.019
|
“Mass and ionic composition of atmospheric fine particles over Belgium and their relation with gaseous air pollutants”. Bencs L, Ravindra K, de Hoog J, Rasoazanany EO, Deutsch F, Bleux N, Berghmans P, Roekens E, Krata A, Van Grieken R, Journal of environmental monitoring 10, 1148 (2008). http://doi.org/10.1039/B805157G
Abstract: Mass, major ionic components (MICs) of PM2.5, and related gaseous pollutants (SO2, NOx, NH3, HNO2, and HNO3) were monitored over six locations of different anthropogenic influence (industrial, urban, suburban, and rural) in Belgium. SO42-, NO3-, NH4+, and Na+ were the primary ions of PM2.5 with averages diurnal concentrations ranging from 0.44.5, 0.37.6, 0.94.9, and 0.41.2 µg m-3, respectively. MICs formed 39% of PM2.5 on an average, but it could reach up to 8098%. The SO2, NO, NO2, HNO2, and HNO3 levels showed high seasonal and site-specific fluctuations. The NH3 levels were similar over all the sites (26 µg m-3), indicating its relation to the evenly distributed animal husbandry activities. The sulfur and nitrogen oxidation ratios for PM2.5 point towards a low-to-moderate formation of secondary sulfate and nitrate aerosols over five cities/towns, but their fairly intensive formation over the rural Wingene. Cluster analysis revealed the association of three groups of compounds in PM2.5: (i) NH4NO3, KNO3; (ii) Na2SO4; and (iii) MgCl2, CaCl2, MgF2, CaF2, corresponding to anthropogenic, sea-salt, and mixed (sea-salt + anthropogenic) aerosols, respectively. The neutralization and cation-to-anion ratios indicate that MICs of PM2.5 appeared mostly as (NH4)2SO4 and NH4NO3 salts. Sea-salt input was maximal during winter reaching up to 12% of PM2.5. The overall average Cl-loss for sea-salt particles of PM2.5 at the six sites varied between 69 and 96% with an average of 87%. Principal component analysis revealed vehicular emission, coal/wood burning and animal farming as the dominating sources for the ionic components of PM2.5.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/B805157G
|
“Minimum requirements for reporting analytical data for environmental samples”. Egli H, Dassenakis M, Garelick H, Van Grieken R, Peijnenburg WJGM, Klasinc L, Kördel W, Priest N, Tavares T, Pure and applied chemistry 75, 1097 (2003). http://doi.org/10.1351/PAC200375081097
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1351/PAC200375081097
|
“Editorial”. van Grieken R, Bogaerts A, Janssens K, Spectrochimica acta: part A: molecular spectroscopy 64, 1089 (2006). http://doi.org/10.1016/j.saa.2006.05.011
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.536
DOI: 10.1016/j.saa.2006.05.011
|
“Optimization of sample preparation for grazing emission X-ray fluorescence in micro- and trace analysis applications”. Claes M, de Bokx P, Willard N, Veny P, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 52, 1063 (1997). http://doi.org/10.1016/S0584-8547(96)01654-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(96)01654-0
|