“New Chinese members of the Advisory Board of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 35, 205 (2006)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Heavy metal analysis around Iskenderun Bay in Turkey”. Čevik U, Koz B, Makarovska Y, X-ray spectrometry 39, 202 (2010). http://doi.org/10.1002/XRS.1250
Abstract: The heavy metal analysis around Iskenderun Bay in Turkey was carried out using mosses, soils, mussels, and sediments. This region is one of the most industrial areas of Turkey, including iron-steel plants, beverage, liquefied petroleum gas (LPG) plants, and oil transfer docks. Energy dispersive X-ray fluorescence spectrometry (Epsilon 5, PANalytical, Almelo, The Netherlands) was used to analyze all samples. V, Cr, Mn, Fe, Ni, Cu, Zn, As, and Pb elements were observed in all samples studied. Although Ce was detected in some mosses and soils, Sn was detected only in some moss samples. Pb concentrations in the moss samples are higher than the soil, the mussel, and the sediment samples. This can be attributed to the mosses that absorb heavy metals such as Pb easily from the air. As the aim of this study was to analyze heavy metals, the evaluation of these elements with their potential hazards for ecology and humans is briefly discussed
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1250
|
|
|
“Influence of sample thickness, excitation energy and geometry on particle size effects in XRF”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 14, 183 (1985). http://doi.org/10.1002/XRS.1300140409
Abstract: Expressions are presented for calculating the matrix effect and the pure particle size effect in the XRF analysis of particulate samples with a discrete particle size. The equations are based on the absorption-weighted radiometric diameter concept. Two excitationdetection geometries are considered, with the angles between the sample plane and both the incident and emerging radiation being either 90° (π geometry) or 45° (π/2 geometry). Calculations were made for different sample loadings and exciting radiation energies. The influence of these parameters on the matrix and pure particle size effects is shown. From the results, it is possible to predict the performances of alternative experimental correction procedures for the particle size effect, involving dual measurements at different excitation energies or in different excitationdetection geometries.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300140409
|
|
|
“Energy-dispersive X-ray fluorescence analysis of geological materials in borax beads using Tertian's binary coefficient approach combined with internal standard addition”. Muia LM, Van Grieken R, X-ray spectrometry 20, 179 (1991)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Editorial : introducing Dr Markowicz as X-Ray Spectrometry's new associate editor for Europe”. Van Grieken R, X-ray spectrometry 42, 175 (2013). http://doi.org/10.1002/XRS.2447
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2447
|
|
|
“High-energy polarized-beam EDXRF for trace metal analysis of vegetation samples in environmental studies”. Marguí, E, Padilla R, Hidalgo M, Queralt I, Van Grieken R, X-ray spectrometry 35, 169 (2006). http://doi.org/10.1002/XRS.890
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.890
|
|
|
“Trace analysis of estuarine brown algae by energy-dispersive X-ray fluorescence”. Sauter L, Van der Ben D, Van Grieken R, X-ray spectrometry 8, 159 (1979). http://doi.org/10.1002/XRS.1300080405
Abstract: Brown algae, which are good indicators for estuarine metal pollution, can advantageously be analysed by energy-dispersive X-ray fluorescence. The use of thin film samples and samples of intermediate thickness has several advantages over the conventional thick pellet procedure. A quite homogeneous thin target is prepared by suspending 15 mg of dried and ground seaweed powder in bi-distilled water and evaporating the slurry on a 10 cm2 Mylar foil held in a Teflon ring. The effective sample weight in the beam is calculated by a procedure based on the scatter peaks in the spectrum. Sensitivities are typically in the 215 ppm range. The coefficient of variation per analysis averaged over ten elements amounts to 10%. The natural concentration variation in seaweed specimens at one location is 13%. Samples from locations in the more polluted western Scheldt estuary yield significantly higher values for several elements, relative to the eastern Scheldt sites. Possible trace element variations between the top and base of plants, and between different seaweed specimens and sampling seasons, are discussed.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300080405
|
|
|
“Energy-dispersive X-ray fluorescence in geochemical mapping”. Civici N, Van Grieken R, X-ray spectrometry 26, 147 (1997). http://doi.org/10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/(SICI)1097-4539(199707)26:4<147::AID-XRS193>3.0.CO;2-X
|
|
|
“Optimization of experimental conditions of thin-window EPMA for ligh-element analysis of individual environmental particles”. Szalóki I, Osán J, Worobiec A, de Hoog J, Van Grieken R, X-ray spectrometry 30, 143 (2001). http://doi.org/10.1002/XRS.473.ABS
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.473.ABS
|
|
|
“Comparison of x-ray absorption and emission techniques for the investigation of paintings”. Cabal A, Schalm O, Eyskens P, Willems P, Harth A, van Espen P, X-ray spectrometry 44, 141 (2015). http://doi.org/10.1002/XRS.2591
Abstract: Four x-ray techniques: computed radiography, emission radiography, energy-resolved radiography and imaging x-ray fluorescence were compared using four mock-up panel paintings. The paintings have different stratigraphy and pigments and are representative for different historical periods. One of the paintings has a hidden underlying painting. The type of pigments used mainly influences the information obtained by both the emission and absorption measurements; high-Z white pigment and high-Z color pigments giving the best contrast. Each of the techniques revealed interesting aspects of the paintings, but none of them could reveal the hidden painting to a satisfactory level. Due to the statistical quality of the spectral data, x-ray fluorescence gives elemental images with high contrast. The radiographic images are better to reveal the internal structure. Imaging x-ray fluorescence and energy-resolved radiography measurements can be done simultaneously, and the combination has the highest potential for the study of complex multilayer paintings. Copyright (c) 2015 John Wiley & Sons, Ltd.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)
DOI: 10.1002/XRS.2591
|
|
|
“Use of theoretical accurate binary influence coefficients with Tertian's equation in X-ray fluorescence analysis of silicate rocks in borax glass beads”. Muia LM, Van Grieken R, X-ray spectrometry 19, 141 (1990). http://doi.org/10.1002/XRS.1300190311
Abstract: A study of the suitability of the Tertian algorithm using new accurate binary influence coefficients and a comparison standard for x-ray fluorescence analysis of geological materials prepared as borax glass beads was performed. The algorithm was found to give satisfactory results for the analysis of four major components in geological materials. Even in the worst case, when there is a factor of 20 difference in the concentration in the specimen and a comparison standard, the algorithm gives results which differ from the true results by a factor of about 2. This makes the algorithm attractive as a diagnostic tool in analyses of unknown specimens and in the identification of appropriate standards. The binary coefficients are easily calculated so that the algorithm can be implemented on a minicomputer.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300190311
|
|
|
“Evaluation of an equation for bremsstrahlung background in electron-probe X-ray microanalysis of composite samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 131 (1986). http://doi.org/10.1002/XRS.1300150211
Abstract: A new equation for predicting the generated bremsstrahlung background intensity in electron-probe x-ray microanalysis has been verified experimentally. This equation is applicable to all bulk composite specimens and reduces to Kramers' equation for pure elements only. The experimental verification has been carried out for Al2O3, Fe2O3 and ZrO2 with radiation energies from 4.2 to 14.8 keV. The predicted bremsstrahlung intensities are in good agreement with the experimental data.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150211
|
|
|
“A simple absorption correction for electron probe X-ray microanalysis of bulk samples”. Markowicz A, Storms H, Van Grieken R, X-ray spectrometry 15, 115 (1986). http://doi.org/10.1002/XRS.1300150209
Abstract: A simple procedure is proposed for the calculation of the absorption correction factor in electron-probe x-ray microanalysis. It is based on the concept of an effective depth of x-ray production, assuming a rectangular depth distribution function for x-ray generation. This effective x-ray production depth is expressed as a fraction of the x-ray excitation depth given by Whelan's expression. Adequate values for this fraction are presented. Two versions are considered. In the first the effective x-ray production is a function of both the characteristic x-ray energy and the atomic numbers of the matrix elements, whereas in the second one, which is indicated for routine use, the energy dependence is neglected. Calculations pointed to satisfactory results, even for low x-ray energies and high overvoltages.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300150209
|
|
|
“Chemical analysis of 16th to 19th century Limoges School painted enamel objects in three museums of the Low Countries”. van der Linden V, Schalm O, Houbraken J, Thomas M, Meesdom E, Devos A, van Dooren R, Nieuwdorp H, Janssen E, Janssens K, X-ray spectrometry 39, 112 (2010). http://doi.org/10.1002/XRS.1207
Abstract: In this study, the results of analysing of a series of 16th-19th century painted enamel objects of the Limoges School currently in collections in three Dutch and Flemish museums by means of portable and micro x-ray fluorescence analysis (PXRF and µ-XRF) and electron probe micro analysis (EPMA) are presented. The aim of the investigation was the authentication of specific pieces. Therefore, the glass compositions as well as the (glass) colouring agents used by the Limoges' artists were studied as a function of the age of the objects. Due to the evolution of these properties, it is possible to approximately date these objects based on their chemical composition. The complete émail peint collection of the Museum Boijmans-Van Beuningen (Rotterdam, The Netherlands), consisting of 20 émail peint plaques, was analysed with µ-XRF. Quantitative information was obtained by EPMA analysis of 15 enamel fragments of objects from museum and private collections in the Low Countries. PXRF analyses were performed on the painted enamel collection of the Antwerp Vleeshuis Museum (13 objects) and the Mayer van den Bergh Museum (4 objects) and on a set of 18 plaques that were donated to the Boijmans-Van Beuningen Museum by a private collector. The results obtained by means of EPMA, µ-XRF and PXRF proved to be useful in the discrimination of 16th century painted enamel objects from those of the19th century. From a total of 70 objects examined, 2 objects (OM964A and OM993) featured a chemical signature that deviated from the published literature composition and pigment use consistent with its presumed period of manufacture.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 8
DOI: 10.1002/XRS.1207
|
|
|
“EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials”. Belikov KN, Mikhailova LI, Spolnik ZM, Van Grieken R, X-ray spectrometry 35, 112 (2006). http://doi.org/10.1002/XRS.874
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.874
|
|
|
“Automated matrix-correction of line ratios in energy-dispersive x-ray fluorescence spectrum deconvolution”. Van Dyck P, Van Grieken R, X-ray spectrometry 12, 111 (1983). http://doi.org/10.1002/XRS.1300120306
Abstract: Most computer XRF-spectrum deconvolution routines make use of fixed intensity ratios for the lines from one element. The magnitude of the error that fixed ratios imply has been quantitatively evaluated for samples with a varible thickness or matrix. A procedure for routinely adapting the line ratios according to the matrix effect in every sample (by making use of the matrix information present in the scatter peaks) enhances the accuracy of the spectrum evaluation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300120306
|
|
|
“James Ensor's pigment use: artistic and material evolution studied by means of portable X-ray fluorescence spectrometry”. van der Snickt G, Janssens K, Schalm O, Aibéo C, Kloust H, Alfeld M, X-ray spectrometry 39, 103 (2010). http://doi.org/10.1002/XRS.1235
Abstract: In this paper, portable X-ray fluorescence spectrometry (PXRF) was employed as a screening tool for determining and comparing the pigment use in a large series of paintings by the Belgian artist James Ensor (1860-1949). Benefits and drawbacks of PXRF as a method, and the instrument employed, are discussed from a practical, conservation and instrumental perspective. Regardless of several restrictions due to the set-up and/or the analytical method, it appeared feasible to document the evolution with time in Ensor's use of inorganic pigments and to correlate this technical evolution with stylistic developments, Nevertheless, it became clear that a full identification of all materials present can only be done by means of the analysis of (cross-sectioned) samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 25
DOI: 10.1002/XRS.1235
|
|
|
“Comparative material characterization of historical and industrial samples by using a compact micro-XRF spectrometer”. Bichlmeier S, Janssens K, Heckel J, Hoffmann P, Ortner HM, X-ray spectrometry 31, 87 (2002). http://doi.org/10.1002/XRS.563
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
Times cited: 12
DOI: 10.1002/XRS.563
|
|
|
“Performance of a new compact EDXRF spectrometer for aerosol analysis”. Samek L, Injuk J, van Espen P, Van Grieken R, X-ray spectrometry 31, 84 (2002). http://doi.org/10.1002/XRS.551
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.551
|
|
|
“Use of microscopic XRF for non-destructive analysis in art an archaeometry”. Janssens K, Vittiglio G, Deraedt I, Aerts A, Vekemans B, Vincze L, Wei F, de Ryck I, Schalm O, Adams F, Rindby A, Knöchel A, Simionovici AS, Snigirev A, X-ray spectrometry 29, 73 (2000). http://doi.org/10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.298
DOI: 10.1002/(SICI)1097-4539(200001/02)29:1<73::AID-XRS416>3.3.CO;2-D
|
|
|
“Automatic absorption correction in x-ray fluorescence analysis of intermediate thickness samples using a dual external reference signal”. Van Dyck P, Markowicz A, Van Grieken R, X-ray spectrometry 9, 70 (1980). http://doi.org/10.1002/XRS.1300090209
Abstract: A method has been investigated which allows calculations from the X-ray fluorescence spectra of the absorption coefficients at any energy for any sample, without any additional measurement. Use is made of the ratio of the characteristic X-ray signals from a Zr wire positioned in front of the sample and from a Pd foil placed behind the sample, both in a fixed geometry. From the experimentally measured absorption coefficient at the Pd L energy (2.9 keV), the coefficients for higher energies are calculated. By the use of an iterative computer routine in which corrections for the enhancement of the Pd foil by the sample are also included, an accuracy of 2% or better on the absorption coefficient determination can be reached for homogenous samples in one measurement. Grain-size and heterogeneity effects induce inaccuracies on the absorption coefficient determinations which might well reach 20% for particulate samples like intermediate thickness deposits of geological materials. This approach thus has the same limitations as the classical transmission method for such heterogeneous samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090209
|
|
|
“Awards for best referees of X-ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 68 (2014). http://doi.org/10.1002/XRS.2530
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2530
|
|
|
“Introducing John Campbell, the new regional editor for North America of X-Ray Spectrometry”. Van Grieken R, X-ray spectrometry 43, 67 (2014). http://doi.org/10.1002/XRS.2534
Keywords: Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.2534
|
|
|
“Folding of aerosol loaded filters during X-ray fluorescence analysis”. Van Grieken RE, Adams FC, X-ray spectrometry 5, 61 (1976). http://doi.org/10.1002/XRS.1300050204
Abstract: Folding aerosol loaded filters in two with the loaded side inwards during the X-ray analysis not only reduces possible filter heterogeneity effects and improves sample protection, but also increases the sensitivity and renders filter paper absorption corrections simple and more accurate in many instances. It is shown that folding an aerosol loaded Whatman filter paper during Kα X-rays counting leads to an increased sensitivity for all elements up from calcium, scandium or titanium (depending on the sensitivity definition and on the aerosol load) and for all elements up from phosphorus, sulphur or chlorine in the case of the Nuclepore filter. Although the absorption by the filter, into which the aerosol penetrates to some extent, is always more important in the sandwich than in the usual geometry, the dependence of the absorption correction on the usually unknown average deposition depth is less pronounced. Assuming all the aerosol material to be collected at the very surface of the filter and hence being present in the centre of the sandwich to be analysed, leads to an extremely simple filter paper absorption correction which is less prone to uncertainties than more sophisticated corrections in the usual geometry requiring additional measurements. This is the case for all elements up from potassium on Whatman filters and up from phosphorus on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300050204
|
|
|
“Radiometric diameter concept and exact intensities for spherical particles in x-ray fluorescence analysis”. Markowicz A, Van Dyck P, Van Grieken R, X-ray spectrometry 9, 52 (1980). http://doi.org/10.1002/XRS.1300090205
Abstract: In X-ray fluorescence analysis the concept of radiometric diameter, d, is often introduced in considerations of the fluorescent intensity from a particulate sample. It represents the mean geometric path of the X-rays through one particle and is usually simply taken to be equal to the volume-to-area ratio of the particle. The effective radiometric path is, however, itself dependent on geometry and absorption effects. Rigorous calculations of the fluorescent intensity from a particle in the π and π/2 geometries were carried out to evaluate the errors involved. It appears that, for π geometry, the discrepancy between these exact results and the intensity calculated via the use of d does not exceed 5.2%. For the π/2 geometry, the errors are much larger and can amount to 50% in realistic cases of X-ray fluorescence analysis. These conclusions are also applicable to monolayers. The effective radiometric diameter approaches d only when absorption effects become negligible, but is smaller in other cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300090205
|
|
|
“Efficiency calibartion of energy-dispersive detectors for application in quantitative x- and γ-ray spectrometry”. Szalóki I, Szegedi S, Varga K, Braun M, Osán J, Van Grieken R, X-ray spectrometry 30, 49 (2001). http://doi.org/10.1002/XRS.467
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.467
|
|
|
“Evaluation of the ArmstrongBuseck correction for automated electron probe X-ray microanalysis of particles”. Storms HM, Janssens KH, Török SB, Van Grieken RE, X-ray spectrometry 18, 45 (1989). http://doi.org/10.1002/XRS.1300180203
Abstract: The ArmstrongBuseck correction for absorption effects in electron probe x-ray microanalysis of particles considers seven specific particle shapes, and for these geometries exact correction equations are used. This procedure implies that the analyst has to associate the particle to be analysed with a certain particle type; an arbitrary relative thickness is sometimes assumed. A theoretical study was made of this absorption correction as a function of the particle composition, type and thickness for micrometre-sized particles. It appears that a correct choice of the particle type is critical. However, when the analytical results are normalized to 100%, the differences between the models are much less pronounced, and it is justified to assume a spherical model in all cases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300180203
|
|
|
“Literature trends in x-ray emission spectrometry in the period 1990-2000: a review”. Injuk J, Van Grieken R, X-ray spectrometry 32, 35 (2003). http://doi.org/10.1002/XRS.606
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.606
|
|
|
“Determination of sample thickness via scattered radiation in X-ray fluorescence spectrometry with filtered continuum excitation”. Araujo MF, van Espen P, Van Grieken R, X-ray spectrometry 19, 29 (1990). http://doi.org/10.1002/XRS.1300190107
Abstract: A semi-empirical approach is described for determining the mass per unit area of a sample being analysed. The method can be used to estimate the concentration of minor and trace elements in matrices containing a substantial amount of light elements. The procedure utilizes the coherently and incoherently scattered radiation induced in the sample by the filtered continuum radiation of a rhodium x-ray tube. The relationship between the intensity of the scattered radiation per unit mass and the average atomic number of the sample is established via calibration graphs, which can be applied for different x-ray tube voltages and for different primary beam filters. The overall procedure was validated by the analysis of several geological standards, deposited as thin slurries of unknown thickness either on Mylar foil or on Nuclepore filters.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.1300190107
|
|
|
“Heterogeneity effects in direct X-ray fluorescence analysis of hair”. Török S, Van Dyck P, Van Grieken R, X-ray spectrometry 13, 27 (1984). http://doi.org/10.1002/XRS.1300130106
Abstract: The methodology of direct hair analysis by energy-dispersive x-ray fluorescence was studied. The effect on the XRF result of having a non-homogeneous radial distribution of the analyte in a single hair strand and the macroscopic effects in a bundle of hairs were calculated to evaluate possible systematic errors. The detection limits were mapped as a function of the target thickness and surface fraction. It appeared that a 10 mg cm−2 sample thickness, i. e. a target with about four layers of hair strands, is recommended. The standard deviation of this simple direct analytical method is 619% for some important elements. Discrepancies with neutron activation analysis had a mean value of around 15%. About twelve elements can be determined simultaneously on a routine basis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.1300130106
|
|