“Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis”. Anaf W, Horemans B, Van Grieken R, De Wael K, Talanta : the international journal of pure and applied analytical chemistry 101, 420 (2012). http://doi.org/10.1016/J.TALANTA.2012.09.051
Abstract: A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.162
Times cited: 3
DOI: 10.1016/J.TALANTA.2012.09.051
|
|
|
“Dry aerosol deposition over the North Sea estimated from aircraft measurements”. Rojas CM, Otten PM, Van Grieken RE, Laane R page 419 (1991).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Evaluation of energy-dispersive x-ray spectra of low-Z elements from electron-probe microanalysis of individual particles”. Osán J, de Hoog J, van Espen P, Szalóki I, Ro C-U, Van Grieken R, X-ray spectrometry 30, 419 (2001). http://doi.org/10.1002/XRS.523
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1002/XRS.523
|
|
|
“Efficient separation of acetate and formate by ion chromatography: application to air samples in a cultural heritage environment”. Kontozova-Deutsch V, Krata A, Deutsch F, Bencs L, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 75, 418 (2008). http://doi.org/10.1016/J.TALANTA.2007.11.025
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.11.025
|
|
|
“Water analysis by spark-source mass-spectrometry after preconcentration on activated carbon”. Vanderborght BM, Van Grieken RE, Talanta : the international journal of pure and applied analytical chemistry 27, 417 (1980). http://doi.org/10.1016/0039-9140(80)80225-6
Abstract: For trace analyses of environmental waters, spark-source mass-spectrometry has been combined with a preconcentration procedure involving chelation of the dissolved trace elements with oxine and subsequent adsorption of the oxinates and naturally occurring organic and colloidal metal species onto activated carbon. The activated carbon is filtered off and ashed at low temperature. The residue is dissolved, an internal standard and pure graphite are added and, after drying, the electrodes are prepared. The photographically recorded mass spectrum is evaluated by a suitable computer routine. The error of the procedure is around 30%. While this preconcentration and analysis procedure is capable of measuring about 40 elements quantitatively, in practice 1025 trace elements are determined simultaneously above the 0.1-μg/l. detection limit, as is illustrated by analyses of drinking water, surface and ground water samples. Although a sophisticated technique, SSMS can be considered for regular panoramic survey analyses.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0039-9140(80)80225-6
|
|
|
“Combined SEM/EDX and micro-Raman spectroscopy analysis of uranium minerals from a former uranium mine”. Stefaniak EA, Alsecz A, Frost R, Máthé, Z, Sajó, IE, Török S, Worobiec A, Van Grieken R, Journal of hazardous materials 168, 416 (2009). http://doi.org/10.1016/J.JHAZMAT.2009.02.057
Abstract: Samples of the secondary uranium minerals collected in the abandoned uranium mine at Pecs (Hungary) were investigated by two micro-techniques: scanning electron microscopy (SEM/EDX) and micro-Raman spectroscopy (MRS). They were applied to locate U-rich particles and identify the chemical form and oxidation state of the uranium compounds. The most abundant mineral was a K and/or Na uranyl sulphate (zippeite group). U(VI) was also present in the form showing intensive Raman scattering at 860 cm−1 which can be attributed to uranium trioxide. This research has shown the successful application of micro-Raman spectroscopy for the identification of uranyl mineral species on the level of individual particles.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JHAZMAT.2009.02.057
|
|
|
“Quantification problems in light element determination by grazing emission X-ray fluorescence”. Kuczumow A, Claes M, Schmeling M, Van Grieken R, de Gendt S, Journal of analytical atomic spectrometry 15, 415 (2000). http://doi.org/10.1039/A908724I
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1039/A908724I
|
|
|
“Trace element composition of Zaire suspended sediments”. Martin J-M, Thomas AJ, Van Grieken RE, Netherlands journal of sea research 12, 414 (1978). http://doi.org/10.1016/0077-7579(78)90043-1
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90043-1
|
|
|
“X-ray analysis of riverbank sediment of the Tisza (Hungary): identification of particles from a mine pollution event”. Osán J, Kurunczi S, Török S, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 57, 413 (2002). http://doi.org/10.1016/S0584-8547(01)00405-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(01)00405-0
|
|
|
“Analysis of indoor gaseous formic and acetic acid, using radial diffusive samplers”. Stranger M, Potgieter-Vermaak S, Sacco P, Quaglio F, Pagani D, Cocheo C, Godoi AFL, Van Grieken R, Environmental monitoring and assessment 149, 411 (2009). http://doi.org/10.1007/S10661-008-0217-6
Abstract: A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 ìg m−3 and 1248 ìg m−3 were determined to be 91.2 ± 3.9 ml min−1 and 111.6 ± 2.8 ml min−1, respectively. The acetic acid sampling rate was independent of the concentration in the range 160 ìg m−31564 ìg m−3, and amounted to 97.3 ± 3.1 ml min−1. Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 321% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 ± 0.07 ìg for formic acid and 1.21 ± 0.14 ìg for acetic acid, and detection limits lower than 0.5 ìg m−3 could be achieved, which is an improvement of 9899% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-008-0217-6
|
|
|
“Barite formation in the Southern Ocean water column”. Stroobants N, Dehairs F, Goeyens L, Vanderheijden N, Van Grieken R, Marine chemistry 35, 411 (1991). http://doi.org/10.1016/S0304-4203(09)90033-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(09)90033-0
|
|
|
“Specimen preparation”. Injuk J, Van Grieken R, Blank A, Eksperiandova L, Buhrke V page 411 (2006).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“The major-element composition of suspended matter in the Zaire river and estuary”. Sholkovitz ER, Van Grieken R, Eisma D, Netherlands journal of sea research 12, 407 (1978). http://doi.org/10.1016/0077-7579(78)90042-X
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(78)90042-X
|
|
|
“Quantification in XRF analysis of intermediate-thickness samples”. Markowicz AA, Van Grieken RE page 407 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Assessment of air quality after the implementation of Compressed Natural Gas (CNG) as fuel in public transport in Delhi, India”. Ravindra K, Wauters E, Tyagi SK, Mor S, Van Grieken R, Environmental monitoring and assessment 115, 405 (2006). http://doi.org/10.1007/S10661-006-7051-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S10661-006-7051-5
|
|
|
“Inorganic mass spectrometry”. Adams F, Gijbels R, Van Grieken R Wiley, Chichester, page 404 p. (1988).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Pixe analysis of aerosol samples collected over the atlantic-ocean from a sailboat”. Maenhaut W, Selen A, van Espen P, Van Grieken R, Winchester WJ, Nuclear instruments and methods 181, 399 (1981). http://doi.org/10.1016/0029-554X(81)90640-6
Abstract: Size-fractionated aerosol samples, collected over the Atlantic Ocean, were analyzed for up to 20 elements by PIXE. Using a sailboat as sampling platform, duplicate samples were taken for two-day periods by means of battery operated 6-stage cascade impactors, positioned about 8 m above the sea surface. In the PIXE analysis of the fine particle stages (stages 3 to 5) a 5 times smaller beam size was used than for stages 1 and 2. This led to significant improvement in the detection limits for the former stages. The results from the duplicate impactor samples were normally in good agreement, indicating that the combined uncertainty of sampling and PIXE analysis was of the order of 20%. The precision of the PIXE analysis alone was investigated by rebombarding some samples six months after the first analysis. The trends with time of the fine particle sulfur and the coarse particle iron concentrations are discussed in some detail.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/0029-554X(81)90640-6
|
|
|
“Reduction of trace metal levels in analytical-grade activated carbon”. Vanderborght B, Van Grieken R, Analytica chimica acta 89, 399 (1977). http://doi.org/10.1016/S0003-2670(01)84739-5
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(01)84739-5
|
|
|
“Sedimentation rate of the floodplain sediments of the Yamuna river basin (tributary of the river Ganges, India) by using <tex>210Pb</tex>, and <tex>137Cs</tex>, techniques”. Saxena DP, Joos P, Van Grieken R, Subramanian V, Journal of radioanalytical and nuclear chemistry 251, 399 (2002). http://doi.org/10.1023/A:1014821906600
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1023/A:1014821906600
|
|
|
“Loss of particulate organic matter in estuaries as exemplified by the Ems and Gironde estuaries”. Eisma D, Bernard P, Boon JJ, Van Grieken R, Kalf J, Mook WG, Mitteilungen aus dem Geologisch-Paläontologischen Institut der Universität Hamburg 58, 397 (1985)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Use of laser microprobe mass analysis (LAMMA) for localizing multiple elements in soft and hard tissues”. Verbueken AH, van de Vijver FL, Visser WJ, Roels F, Van Grieken R, de Broe ME, Biological trace element research 13, 397 (1987). http://doi.org/10.1007/BF02796651
Abstract: The potential of laser microprobe mass analysis (LAMMA) as a sensitive microanalytical technique was explored in applications relevant to nephrology. Aluminum and associated elements, such as iron, were localized in fresh tissue biopsies obtained from uremic patients treatment by chronic hemodialysis. The LAMMA was applied to serum, liver, bone, and parathyroid glands of such patients. In addition, we used LAMMA to evaluate the specificity and sensitivity of routine histochemistry, in particular on human bone sections stained by the aluminon method. The high, multielemental sensitivity and molecular microprobe potential of LAMMA established important advantages over other microchemical methods forin situ analysis at the micron level in histological sections.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/BF02796651
|
|
|
“Trace element geochemistry in thermal waters from Plombières and Bains (Vosges)”. Gijbels R, van Grieken R, Blommaert W, Vandelannoote R, Van 't dack L, , 396 (1980)
Keywords: P3 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
Adams F, Gijbels R, Van Grieken R, Dachang Z (1993) Inorganic mass spectrometry. Fudan University Press, Shanghai, 391 p
Keywords: MA3 Book as author; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Elemental composition of aircraft-sampled aerosols above the Southern Bight of the North Sea”. Rojas CM, Van Grieken R, Maenhaut W, Water, air and soil pollution 71, 391 (1993). http://doi.org/10.1007/BF00480557
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF00480557
|
|
|
“Optimisation of light element analysis of individual particles using UTW-EPMA”. de Hoog J, Osán J, Worobiec A, Ro C-U, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 388 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Simultaneous determination of silicon and phosphorus in cast iron by 14 MeV neutron activation analysis”. Van Grieken R, Speecke A, Hoste J, Journal of radioanalytical chemistry 6, 385 (1970). http://doi.org/10.1007/BF02513966
Abstract: A fast (10 min), non-destructive simultaneous determination of silicon and phosphorus in cast iron and steel by 14 MeV neutron activation was developed. The 1.78 MeV28Al activity (T=2.24 min) induced by the reaction28Si(n, p)28Al is counted on a NaI(Tl) detector. Two measurements are made to correct for the 1.81 MeV56Mn activity (T=2.58 hr) from the iron matrix. However,28Al is also produced via31P(n, α)28Al. By (n, 2n) reaction, phosphorus yields also30P (T=2.6 min), the 0.511 MeV annihilation radiation of which is counted by two opposite NaI(Tl) detectors in coincidence. Again, two successive coincidence measurements are carried out in order to take into account the53Fe activity (β+; T=8.9 min) from54Fe(n, 2n)53Fe. The28Al measurement is appropriately corrected via the computed phosphorus content. An oxygen flux monitor was used to normalize to the same flux. Nuclear interferences have been examined. Special attention has been paid to the presence of copper. The standard deviation for phosphorus being as high as ca. 0.09% P for a single determination, this technique can only be practical as an independent phosphorus analysis for high phosphorus cast irons. The precision on the28Al measurement is 5% relative for 0.2% Si and 2.5% above 1% Si.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF02513966
|
|
|
“Trace metals in the St-Louis aerosol”. Winchester JW, Meinert DL, Nelson JW, Johansson TB, Van Grieken RE, Orsini C, Kaufmann HC, Akselsson R page 385 (1975).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Unconventional microanalysis for low-Z, volatile and organic aerosol compounds”. Worobiec A, de Hoog J, Osán J, Szalóki I, Joos P, Van Grieken R, Journal of aerosol science 31, 384 (2000)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Dispersal of suspended matter in Makasar Strait and the Flores Basin”. Eisma D, Kalf J, Karmini M, Mook WG, Van Put A, Bernard P, Van Grieken R, Netherlands journal of sea research 24, 383 (1989). http://doi.org/10.1016/0077-7579(89)90116-6
Abstract: In November 1984 in Makasar and the Flores Basin water samples were collected (T, S, dissolved O2, total CO2), bottom samples (sediment composition) and suspended matter (particle composition, particle size). A sediment trap was moored in the Flores Basin at 4600 m depth for nearly four months, covering the dry season. In the Flores Basin there are indications for bottom flow resuspending bottom material or preventing suspended material from settling; in Makasar Strait there is probably inflow of deep water both from the south and from the north, resulting in a very slow bottom water flor. Bottom deposits in Makasar Strait and the Flores Basin are predominantly terrigenous, with an admixture of organic carbonate and silica (mostly coccoliths). Volcanic material is primarily present near to the volcanoes in the south and reaches the deeper basins by slumping. In the suspended matter no volcanic particles and little planktonic material were found, although the latter form 10 to 15% of the top sediment and of the material deposited in the sediment trap. In suspension particles with a large concentration of tin (Sn) were found associated mainly with iron. They probably come from northern Kalimantan or northern Sulawesi. Suspended matter concentrations were mainly less than 0.5 mg·dm−3, only off the Mahakam river mouth were concentrations higher than 1 mg·dm−3. Particle size was erratic because of the variable composition of the coarser particles in suspension. Organic matter concentrations in suspension (in mg·dm−3) roughly follow the distribution of total suspended matter but organic content (in %) of the suspended matter does not show any trends. All organic matter in suspension is of marine origin except in the Mahakam river and estuary. Deposition rates, as estimated from the sediment trap results, are 150 mg·cm−2·a−1 for the total sediment, 26 mg·cm−2·a−1 for carbonate and 13 mg·cm−2·a−1 for organic matter. Flocs and fibres in suspension were only found in and below the Mahakam river plume that reaches ca 400 km from the river mouth to the southeast, and in surface waters associated with plankton (diatoms). The formation of these flocs (broken-up macroflocs or marine snow) is primarily related to particle concentration, turbulence, and the presence of organisms that produce sticky material or glue particles together.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0077-7579(89)90116-6
|
|
|
“Monitoring of tropospheric ozone in the ambient air with passive samplers”. Alejo ellys, Morales MC, Nuñez V, Bencs L, Van Grieken R, van Espen P, Microchemical journal 99, 383 (2011). http://doi.org/10.1016/J.MICROC.2011.06.010
Abstract: Two sampling campaigns in suburban places in the north zone of Santa Clara city, Cuba, have been carried out on a weekly base with the use of Radiello passive diffusion tubes in order to monitor the tropospheric ozone (O3) levels in 2010. The first campaign was scheduled from February to April (cold season) and the second one in August and October (warm season), both of them at two sampling sites, i.e., Farm and School of Art Instructors. After aqueous extraction, the samples were analyzed by UVVIS spectrophotometry. A seasonal trend was observed with the maximum O3 concentrations in the cold season and the minimum levels in the warm season. Samples collected during the cold season showed the highest O3 levels. Higher levels were reached at the Farm site with average values of about 58 ± 12 μg/m3, which exceeded the limit of the Cuban Standard 99:1999. In the warm season, the O3 concentrations were similar for both sites, but lower than those observed in the cold season. The overall, seasonal average value was found to be 24 μg/m3. Despite the higher weekly average temperatures in August, the O3 concentrations during this month showed the lowest values of the whole sampling period, which finding is in agreement with that reported by the Meteorological Institute of Cuba. Mathematical models, based on the Cochrane-Orcutt algorithm, were fitted to the acquired data set to explain the change in the tropospheric ozone concentrations under various meteorological conditions during the two campaigns. The correlation coefficients for both the cold and the warm seasons demonstrated a strong correlation, i.e., 0.779 and 0.951, respectively. The high correlation of wind speed in the model from the first sampling campaign explains the sharp decrease in O3 concentrations at the SAI sampling site from the sixth week of sampling.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2011.06.010
|
|