“Electron probe micro-analysis and laser microprobe mass analysis of material, leached from a limestone cathedral”. Leysen LA, De Waele JK, Roekens EJ, Van Grieken RE, Scanning microscopy 1, 1617 (1987)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Radiation damage evaluation on LYSO and LuYAP materials through Dpa calculation assisted by Monte Carlo method”. Piñera I, Abreu Y, van Espen P, Diaz A, Leyva A, Cruz CM, IEEE conference record
T2 –, IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th, International Workshop on Room-Temperature Semiconductor X-Ray and, Gamma-Ray Detectors, OCT 23-29, 2011, Valencia, SPAIN , 1609 (2011)
Abstract: The aim of the present work is to study the radiation damage induced in LYSO and LuYAP crystals by the gamma radiation and the secondary electrons/positrons generated. The displacements per atom (dpa) distributions inside each material were calculated following the Monte Carlo assisted Classical Method (MCCM) introduced by the authors. As gamma sources were used Sc-44, Na-22 and V-48. Also the energy of gammas from the annihilation processes (511 keV) was included in the study. This procedure allowed studying the in-depth dpa distributions inside each crystal for all four sources. It was also possible to obtain the separate contribution from each atom to the total dpa. The LYSO crystals were found to receive more damage, mainly provoked by the displacements of silicon and oxygen atoms.
Keywords: P1 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Composition and sources of aerosols from the Amazon basin”. Artaxo P, Storms H, Bruynseels F, Van Grieken R, Maenhaut W, Journal of geophysical research 93, 1605 (1988). http://doi.org/10.1029/JD093ID02P01605
Abstract: Aerosols were sampled in the Amazon Basin, as part of the Global Tropospheric Experiment (GTE), during the Amazon Boundary Layer Experiment (ABLE 2A) in JulyAugust 1985. Fine- and coarse-particle fractions were analyzed for 22 elements by particle-induced X ray emission. Gravimetric mass, black carbon, sulfate, and nitrate concentrations were also determined. Morphological and trace element measurements of individual particles were carried out by automated electron probe X ray microanalysis. Various receptor models, including multivariate methods and a chemical mass balance model, were employed in the interpretation of the bulk trace element concentrations. Three factors explained over 85% of the variability of fine- and coarse-mode variables. On the basis of the elemental composition of the factors, two could be identified as plant related, and the third was a soil dust component. Of the coarse-mode aerosol mass concentration (of 7.6±1.6 μg/m3), 62% could be attributed to aerosols released by the vegetation and 11% to soil dust. In the fine mode, soil dust accounted for less than 10% of the measured mass concentration (of 6.8±3.9 μg/m3). The variables related to the plant component were K, P, S, Ca, Mg, Cl, Rb, and the gravimetric mass. The elemental profile of the plant component resembled the bulk plant composition. By single-particle analysis coupled with hierarchical cluster analysis, six to nine different biogenic-related particle groups could be identified in the fine- and coarse-aerosol modes. Almost all particle types consisted predominantly of carbonaceous material, with trace amounts of K, S, Ca, P, Cl, and Na. Only one group, comprising less than 11% of the total number of particles, consisted of soil dustrelated aerosol.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1029/JD093ID02P01605
|
“High-E scanning m-XRF experiment on test paintings”. Dik J, Janssens K, van der Snickt G, Wallert A, Rickers K, Falkenberg G page 1589 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Degradation potential of airborne particulate matter at the Alhambra monument : a Raman spectroscopic and electron probe X-ray microanalysis study”. Potgieter-Vermaak S, Horemans B, Anaf W, Cardell C, Van Grieken R, Journal of Raman spectroscopy 43, 1570 (2012). http://doi.org/10.1002/JRS.4052
Abstract: It is well known that airborne particulate matter (APM) has an impact on our cultural heritage. A limited number of articles have been published on the sequential application of elemental and molecular techniques to estimate the degradation potential of APM in environments of cultural heritage importance, and most of these were concerned with indoor environments. The Alhambra monument (Granada, Spain) represents one of the grandest and finest examples of Islamic art and architecture from the Middle Ages. As part of an air quality investigation, two sets of APM were collected at the Hall of the Ambassadors and characterised to determine its potential degradation profile. These were analysed by means of micro-Raman spectroscopy (MRS) and electron probe microanalysis with X-ray detection (EPXMA). The Raman data indicated the presence of various mixed salts of acidic and/or hygroscopic nature, such as sodium and ammonium nitrates and sulfates, especially in the finer fraction. Automated EPXMA estimated this fraction to be as high as 50%. Apart from the potential chemical attack, the soiling due to carbonaceous matter deposition is a real concern. Soot was identified by MRS and EPXMA in all size fractions, reaching values of up to 55%, and was often intertwined with soluble inorganic salts. Ongoing degradation of the pigments is implicated by the presence of brightly coloured particles. MRS and molar abundance ternary diagrams elicited the chemical structure of individual APM so that the degradation potential could be established.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/JRS.4052
|
“Gross alpha and beta activities of airborne particulate samples from Wawel Royal Castle Museum in Cracow, Poland”. Akbulut S, Krupinska B, Worobiec A, Čevik U, Taskin H, Van Grieken R, Samek L, Wiłkojć, E, Journal of radioanalytical and nuclear chemistry 295, 1567 (2013). http://doi.org/10.1007/S10967-012-1983-8
Abstract: Soils are complex mixtures of organic, inorganic materials, and metal compounds from anthropogenic sources. In order to identify the pollution sources, their magnitude and development, several X-ray analytical methods were applied in this study. The concentrations of 16 elements were determined in all the soil samples using energy dispersive X-ray fluorescence spectrometry. Soils of unknown origin were observed by scanning electron microscopy equipped with a Si(Li) X-ray detector using Monte Carlo simulation approach. The mineralogical analyses were carried out using X-ray diffraction spectrometry. Due to the correlations between heavy metals and oxide compounds, the samples were analyzed also by electron probe microanalyzer (EPMA) in order to have information about their oxide contents. On the other hand, soil pH and salinity levels were identified owing to their influence between heavy metal and soil-surface chemistry. Moreover, the geoaccumulation index (I geo) enables the assessment of contamination by comparing current and pre-industrial concentrations.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1007/S10967-012-1983-8
|
“Unraveling the reactivity of minium towards bicarbonate and the role of lead oxides therein”. Ayalew E, Janssens K, De Wael K, Analytical chemistry 88, 1564 (2016). http://doi.org/10.1021/ACS.ANALCHEM.5B02503
Abstract: Understanding the reactivity of (semiconductor) pigments provides vital information on how to improve conservation strategies for works of art in order to avoid rapid degradation of the pigments. This study focuses on the photoactivity of minium (Pb3O4), a semiconductor pigment, that gives rise to strong discoloration phenomena upon exposure to various environmental conditions. To demonstrate its photoactivity, an electrochemical setup with minium-modified graphite electrode (C|Pb3O4) was used. It is confirmed that minium is a p-type semiconductor which is photoactive during illumination and becomes inactive in the dark. Raman measurements confirm the formation of the degradation products. The photoactivity of a semiconductor pigment is partly defined by the presence of lead oxide (PbO) impurities; these introduce new states in the original band gap. It will be experi-mentally evidenced that the presence of PbO particles in minium leads to an upward shift of the valence band that reduces the band gap. Thus, upon photoexcitation, the electron/hole separation is more easily initialized. The PbO/Pb3O4 composite electrodes demonstrate a higher reductive photocurrent compared to the photocurrent registered at pure PbO or Pb3O4 modified electrodes. Upon exposure to light with energy close to and above the band gap, electrons are excited from the valence band to the conduction band to initialize the reduction of Pb(IV) to Pb(II), resulting in the initial formation of PbO. However in the presence of bicarbonate ions, a significantly higher photoreduction current is recorded since the PbO reacts further to form hydrocerussite. Therefore the presence of bicarbonates in the environment stimulates the photodecomposition process of minium and plays an important role in the degradation process.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.32
Times cited: 9
DOI: 10.1021/ACS.ANALCHEM.5B02503
|
“Iron speciation in soda-lime-silica glass: a comparison of XANES and UV-vis-NIR spectroscopy”. Ceglia A, Nuyts G, Meulebroeck W, Cagno S, Silvestri A, Zoleo A, Nys K, Janssens K, Thienpont H, Terryn H, Journal of analytical atomic spectrometry 30, 1552 (2015). http://doi.org/10.1039/C5JA00046G
Abstract: Scientific analyses of ancient glasses have been carried out for many years using elemental chemical analysis. However, it is known that the control of the redox conditions in the glass melt has a strong implication on the final hue of glass because it affects Fe2+/SFe. Therefore an increasing number of studies on the redox conditions have been published in recent years by means of synchrotron based Xray absorption spectroscopy. This is a technique which is not easily accessible and requires dedicated facilities. In this paper we describe an alternative approach by means of optical absorption spectroscopy. We synthesised 10 soda-lime-silica glasses with known redox conditions and iron concentration to calibrate the absorption at 1100 nm as a function of Fe2+ concentration. The linear extinction coefficient was also determined. These glasses were also studied by means of X-ray Absorption Near Edge Structure (XANES) spectroscopy. Electron paramagnetic resonance spectroscopy was additionally used as an ancillary method to verify the quality of our data. Furthermore 28 samples from real archaeological samples were analysed by XANES and optical spectroscopy as a case study. The Fe2+/SFe values obtained were compared and demonstrated that the two techniques were in good agreement with each other. Optical spectroscopy can be applied in situ with moderate sample preparation to determine the concentration of Fe2+. To investigate the redox conditions, especially as a first screening approach, this methodology is an important tool to take into consideration before applying more sophisticated techniques such as XANES, which is more elaborate and requires high-tech resources.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 20
DOI: 10.1039/C5JA00046G
|
“Chemical composition of building materials used in Turkey”. Čevik U, Damla N, Van Grieken R, Vefa Akpinar M, Construction and building materials 25, 1546 (2011). http://doi.org/10.1016/J.CONBUILDMAT.2010.08.011
Abstract: The main goal of this work was to determine the chemical composition of building materials used in Turkey by utilizing energy dispersive X-ray fluorescence (EDXRF) spectrometry. Gas concrete, cement, sand, bricks, roofing tiles, marble, lime and gypsum materials were selected as building materials for this research. The chemical contents and their trace concentrations of the selected samples were determined. The most abundant oxides measured were generally SiO2, Al2O3, CaO, MgO, Fe2O3, K2O and SO3 for all samples. While the main chemical component of gas concrete, cement, sand and marble samples were SiO2 and CaO, brick and roofing tile mainly consisted of SiO2 and Al2O3. CaO and SO3 were major component of lime and gypsum samples, respectively. For U and Th concentrations in the samples, activities of 226Ra and 232Th were measured by utilizing gamma spectrometry. ANOVA and Pearson correlation analyses were performed on the studied data for statistical analysis.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CONBUILDMAT.2010.08.011
|
“Evidence of early medieval soda ash glass in the archaeological site of San Genesio (Tuscany)”. Cagno S, Favaretto L, Mendera M, Izmer A, Vanhaecke F, Janssens K, Journal of archaeological science 39, 1540 (2012). http://doi.org/10.1016/J.JAS.2011.12.031
Abstract: The early medieval period marks an important turning point in the history of glassmaking, since it comprises the transition period between the mineral-based silica-soda-lime glass of the Roman tradition and the plant ash-based glass. With the aim of expanding the knowledge on the glass recipes and technologies of this period, 37 glass samples were analyzed, originating from the archaeological excavations of San Genesio (Tuscany) and dated from the fourth to the eleventh century. The major and minor element concentrations were measured with SEM-EDX, while the trace elements were quantified with LA-ICP-MS. The results were compared with published compositions of glass samples of similar age in order to highlight differences and similarities. The results offer a very interesting view on the glass circulation in the religious/residential/manufacturing center of San Genesio in the early medieval period. Most of the glass has a typical late-Roman composition, but some glass fragments are identified as soda ash glass. These are among the earliest medieval ash-fluxed glasses ever found in the Italian peninsula. (C) 2011 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; Philosophy; History; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.602
Times cited: 24
DOI: 10.1016/J.JAS.2011.12.031
|
“Quantification in grazing-emission X-ray fluorescence spectrometry”. Spolnik ZM, Claes M, Van Grieken RE, de Bokx PK, Urbach HP, Spectrochimica acta: part B : atomic spectroscopy 54, 1525 (1999). http://doi.org/10.1016/S0584-8547(99)00051-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00051-8
|
“Single particle characterisation of inorganic suspension in Lake Baikal”. Jambers W, Van Grieken R, Environmental science and technology 31, 1525 (1997)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Trace elements in the atmospheric aerosols and soils in and around Recife, N.E. Brasil”. Costa Dantas C, Moura de Amorim W, Van 't dack L, Van Grieken R, Ciencia e cultura 32, 1525 (1980)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Determination of low-Z elements in individual environmental particles using windowless EPMA”. Ro C-U, Osán J, Van Grieken R, Analytical chemistry 71, 1521 (1999). http://doi.org/10.1021/AC981070F
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC981070F
|
“Determination of silicon in organic matrices with grazing-emission X-ray fluorescence spectrometry”. Claes M, van Dyck K, Deelstra H, Van Grieken R, Spectrochimica acta: part B : atomic spectroscopy 54, 1517 (1999). http://doi.org/10.1016/S0584-8547(99)00098-1
Abstract: The potential of a prototype grazing-emission X-ray fluorescence spectrometer for reliable analysis of sample solutions, obtained by pressurized microwave oven digestion of Si-spiked organic and biological materials, was investigated as part of an inter-laboratory study. The fact that this grazing-emission technique is based on the total reflection phenomenon and wavelength-dispersive detection, gives it the benefit to determine light elements in a sensitive way. Results of the determination of silicon in pork liver, cellulose, urine, serum, spinach, beer, mineral water and horsetail (dry plant extract) samples are presented. Some of the results are compared with those obtained with other analytical techniques. The study proved that determination of silicon traces in biological matrices represents an extremely difficult task, however, measurements of silicon are achieved with acceptable precision. The most important problems still arise when sample pre-treatment is needed prior to analysis. (C) 1999 Elsevier Science B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0584-8547(99)00098-1
|
“Gypsum and other calcium-rich particles above the North Sea”. Hoornaert S, van Malderen H, Van Grieken R, Environmental science and technology 30, 1515 (1996). http://doi.org/10.1021/ES9504350
Abstract: Ca-containing particles, especially CaSO4 particles, have been encountered in several atmospheric aerosol studies. An overview is given of the different sources of airborne Ca-containing particles, The North Sea atmosphere is studied to identify the different Ca-containing particle types and to find the correlation between their occurrence and the source regions of the corresponding air masses. About 50000 individual aerosol samples were collected above the Southern Eight of the North Sea for several wind directions and analyzed for their composition using electron probe X-ray microanalysis. Nonhierarchical cluster analysis is performed on the data to reveal the different particle types, their relative abundances and their sources. CaSO4 in most cases constitutes the largest fraction of the Ca-containing particles. Extremely high numbers of CaSO4 particles are found for northeastern winds, coming from the central part of Germany, suggesting that a great fraction is derived from anthropogenic sources located in this region. Among the other Ca-containing particle types are the aluminosilicates, CaCO3, Fe-Ca-rich particles, and CaSO4 or CaCO3 in combination with NaCl.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES9504350
|
“Quantitative Fe determination inside tomato roots by confocal μ-XRF”. Terzano R, Spagnuolo M, Ruggiero P, Vekemans B, Scoonjans T, Vincze L, Janssens K, Tomasi N, Cesco S, Falkenberg G page 1513 (2008).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Synchrotron-based X-ray spectromicroscopy and electron paramagnetic resonance spectroscopy to investigate the redox properties of lead chromate pigments under the effect of visible light”. Monico L, Janssens K, Cotte M, Romani A, Sorace L, Grazia C, Brunetti BG, Miliani C, Journal of analytical atomic spectrometry 30, 1500 (2015). http://doi.org/10.1039/C5JA00091B
Abstract: Light-induced redox processes have been established as the cause of the chromatic alterations of a number of artists' pigments used from the 15th to the 20th century. Despite the fact that a general comprehension of the mechanisms has been provided through the characterization of photo-degraded compounds, both exhaustive information on the wavelength-dependence of the alteration process of the pigments and experimental evidence in how visible light may influence the formation pathways of specific secondary compounds are still lacking. Establishing an analytical protocol for the study of wavelength-dependence of pigments on photo-redox pathways is relevant for the safe illumination of paintings, especially in view of the possible use of spectrally tunable light sources such as white light emitting diodes (WLEDs). In this work, we propose an integrated approach based on a combination of diffuse reflectance UV-visible, synchrotron radiation (SR)-based micro X-ray fluorescence (m-XRF)/X-ray absorption near edge structure (m-XANES) and electron paramagnetic resonance (EPR) spectroscopies to study the photo-redox process of Cr(VI) -> Cr(III) for lead chromate yellows (PbCr1-xSxO4, 0 <= x <= 0.8) under exposure to different monochromatic light. In view of the thin (3-5 mm) alteration layer that is formed at the paint surface after light exposure, SR-based Cr K-edge mu-XANES/mu-XRF analysis was employed to obtain information on the abundance, nature and distribution of the alteration of Cr(III)-compounds at the micrometricscale level. On the other hand, EPR spectroscopy was used as a complementary tool to the SR-based X-ray methods due to its sensitivity for revealing species containing one or more unpaired electrons and for distinguishing different coordination geometries of paramagnetic centers, such as Cr(V)-species. Semi-quantitative indications about the darkening of the paint surface were obtained by UV-Vis spectroscopy. An abundance of reduced Cr down to around 50% was detected at the aged surface of chrome yellow paints. The reduction process was favored not only by wavelengths shorter than 460 nm (i.e., where the pigment shows its maximum absorption) but also by light in the 490-530 nm range. The first evidence of the presence of Cr(V)-intermediates in the Cr(VI) -> Cr(III) reduction reaction allowed the risks of inducing photo-degradation of the 490-530 nm wavelength range to be explained.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.379
Times cited: 17
DOI: 10.1039/C5JA00091B
|
“Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments”. Horemans B, Van Grieken R, Atmospheric environment : an international journal 44, 1497 (2010). http://doi.org/10.1016/J.ATMOSENV.2010.01.010
Abstract: Thoracic (PM10), fine thoracic (PM2.5) and sub-micrometer (PM1) airborne particulate matter was sampled during day and night. In total, about 100 indoor and outdoor samples were collected for each fraction at ten different office environments. Energy-dispersive X-ray fluorescence spectrometry and ion chromatography were applied for the quantification of some major and minor elements and ions in the collected aerosols. During daytime, mass concentrations were in the ranges: 1129, 8.124, and 6.618 μg m−3, with averages of 20 ± 1, 15.0 ± 0.9, and 11.0 ± 0.8 μg m−3, respectively. At night, mass concentrations were found to be significantly lower for all fractions. Indoor PM1 concentrations exceeded the corresponding outdoor levels during office hours and were thought to be elevated by office printers. Particles with diameters between 1 and 2.5 μm and 2.5 and 10 μm were mainly associated with soil dust elements and were clearly subjected to distinct periods of settling/resuspension. Indoor NO3 − levels were found to follow specific microclimatic conditions at the office environments, while daytime levels of sub-micrometer Cl− were possibly elevated by the use of Cl-containing cleaning products. Indoor carbon black concentrations were sometimes as high as 22 μg m−3 and were strongly correlated with outdoor traffic conditions.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.ATMOSENV.2010.01.010
|
“Rapid classification and quantification of cocaine in seized powders with ATR-FTIR and chemometrics”. Eliaerts J, Dardenne P, Meert N, Van Durme F, Samyn N, Janssens K, De Wael K, Drug testing and analysis 9, 1480 (2017). http://doi.org/10.1002/DTA.2149
Abstract: Traditionally, fast screening for the presence of cocaine in unknown powders is performed by means of colour tests. The major drawbacks of these tests are subjective colour evaluation depending on the operator (50 shades of blue) and a lack of selectivity. An alternative fast screening technique is Fourier Transform InfraRed (FTIR) spectrometry. This technique provides spectra that are difficult to interpret without specialized expertise and showing a lack of sensitivity for the detection of cocaine in mixtures. To overcome these limitations, a portable FTIR spectrometer using Attenuated Total Reflectance (ATR) sampling was combined with a multivariate technique, called Support Vector Machines (SVM). Representative street drug powders (n = 482), seized during the period January 2013 to July 2015, and reference powders (n = 33) were used to build and validate a classification model (n = 515) and a quantification model (n = 378). Both models were compared with the conventional chromatographic techniques. The SVM classification model showed a high sensitivity, specificity and efficiency (99%). The SVM quantification model determined cocaine content with a root mean squared error of prediction (RMSEP) of 6% calculated over a wide working range from 4 to 99 w%. In conclusion, the developed models resulted in a clear output (cocaine detected or cocaine not detected) and a reliable estimation of the cocaine content in a wide variety of mixtures. The ATR-FTIR technique combined with SVM is a straightforward, user-friendly and fast approach for routine classification and quantification of cocaine in seized powders.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.469
Times cited: 9
DOI: 10.1002/DTA.2149
|
“Characterization of a 2,2'-diaminodiethylamine-cellulose filter toward metal cation extraction”. Smits JA, Van Grieken RE, Analytical chemistry 52, 1479 (1980). http://doi.org/10.1021/AC50059A022
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC50059A022
|
“Possibilities of energy-resolved X-ray radiography for the investigation of paintings”. Cabal Rodríguez AE, Leyva Pernia D, Schalm O, van Espen PJM, Analytical and bioanalytical chemistry 402, 1471 (2012). http://doi.org/10.1007/S00216-011-5230-X
Abstract: X-ray radiographic images of paintings often show little or no contrast. In order to increase the contrast in radiographic images we measured the X-ray spectrum of a low power X-ray tube, after passing through the painting, with a high energy-resolution SDD detector. To obtain images, the detector is collimated with a 400 mu m diameter pinhole and the painting was moved through the beam in the x and y-direction using a dwell time of a few seconds per pixel. The data obtained consists of a data cube of, typically, 200 x 200 pixels and a 512-channel X-ray spectrum for each pixel, spanning the energy range from 0 to 40 keV. Having the absorbance spectrum available for each pixel, we are able, a posteriori, to produce images by edge subtraction for any given element. In this way high contrast, element-specific, images can be obtained. Because of the high energy-resolution a much simpler edge subtraction algorithm can be applied. We also used principal-component imaging to obtain, in a more automated way, images with high contrast. Some of these images can easily be attributed to specific elements. It turns out that preprocessing of the spectral data is crucial for the success of the multivariate image processing.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-011-5230-X
|
“Optimization of measurement conditions of an energy dispersive X-ray fluorescence spectrometer with high-energy polarized beam excitation for analysis of aerosol filters”. Spolnik Z, Belikov K, van Meel K, Adriaenssens E, de Roeck F, Van Grieken R, Applied spectroscopy 59, 1465 (2005). http://doi.org/10.1366/000370205775142647
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1366/000370205775142647
|
“Particulate matter analysis at elementary schools in Curitiba, Brazil”. Avigo D, Godoi AFL, Janissek PR, Makarovska Y, Krata A, Potgieter-Vermaak S, Alfoldy B, Van Grieken R, Godoi RHM, Analytical and bioanalytical chemistry 391, 1459 (2008). http://doi.org/10.1007/S00216-008-2031-Y
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S00216-008-2031-Y
|
“Composition of individual aerosol particles above Lake Baikal, Siberia”. van Malderen H, Van Grieken R, Khodzher T, Obolkin V, Potemkin V, Atmospheric environment : an international journal 30, 1453 (1996). http://doi.org/10.1016/1352-2310(95)00430-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/1352-2310(95)00430-0
|
“Characterization of indoor and outdoor atmospheric pollutants impacting architectural monuments : the case of San Jerónimo Monastery (Granada, Spain)”. Kontozova-Deutsch V, Cardell carolina, Urosevic M, Ruiz-Agudo E, Deutsch F, Van Grieken R, Environmental earth sciences 63, 1433 (2011). http://doi.org/10.1007/S12665-010-0657-5
Abstract: Indoor and outdoor concentrations of atmospheric gaseous pollutants as well as composition, size, and morphology of particulate matter have been investigated at the monastery of San Jerónimo in Granada (Southern Spain). Complementary micro- and nano-analytical techniques were applied; elemental and mineralogical composition and morphological characteristics of particulate matter were investigated combining electron probe microanalysis at the single particle level, and bulk aerosol samples were analyzed using energy-dispersive X-ray fluorescence, X-ray diffraction, scanning electron microscopy with energy-dispersive X-ray analyzer and transmission electron microscopy (TEM). Microclimatic conditions at the monastery were monitored, and gas concentrations were assessed by means of diffusion tubes subsequently analyzed with ion chromatography. Results revealed high abundances of soil dust particles (aluminosilicates, calcite, dolomite, quartz), salt aerosols (chlorides, sulfates and ammonium-rich salts), and NO2 and SO2 both outdoors and indoors. Amorphous black carbon particles had surprisingly high abundances for Granada, a non-industrialized city. The composition of indoor particles corresponds to severe weathering affecting the construction materials and artworks inside the church; moreover their composition promotes a feedback process that intensifies the deterioration. Chemical reactions between chloride-rich salts and pigments from paintings were confirmed by TEM analyses. Indoors, blackening of surface decorative materials is fostered by particle re-suspension due to cleaning habits in the monastery (i.e. dusting). This is the first air quality study performed in a monument in the city of Granada with the aim of developing a strategy for preventive conservation.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/S12665-010-0657-5
|
“Single-particle characterization of four “Asian Dust&rdquo, samples collected in Korea, using low-Z particle electron probe X-ray microanalysis”. Ro C-U, Hwang H, Kim HK, Chun Y, Van Grieken R, Environmental science and technology 39, 1409 (2005). http://doi.org/10.1021/ES049772B
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/ES049772B
|
“Magnetic field oriented tetragonal zirconia with anisotropic toughness”. Zhang L, Vleugels J, Darchuk L, van der Biest O, Journal of the European Ceramic Society 31, 1405 (2011). http://doi.org/10.1016/J.JEURCERAMSOC.2011.02.002
Abstract: (0 0 1)-oriented 3 mol% yttria stabilized tetragonal zirconia (3Y-TZP) has been developed by reactive synthesis of undoped pure monoclinic zirconia and co-precipitated 8 mol% yttria-stabilized zirconia (8Y-ZrO2). The dispersed pure monoclinic ZrO2 powder, having magnetic anisotropy, was first aligned in a strong magnetic field and co-sintered in a randomly distributed cubic 8Y-ZrO2 fine matrix powder. The reactive sintering resulted in a 3Y-TZP ceramic with a (0 0 1) orientation. The (0 0 1)-oriented 3Y-TZP showed a substantial toughness anisotropy, i.e. the toughness along the [0 0 1] direction is 54% higher than that of its perpendicular direction. Moreover, the toughness along the [0 0 1] direction is 49% higher than that of a non-textured isotropic reactively synthesized 3Y-TZP and 110% higher than that of an isotropic co-precipitated powder based 3Y-TZP. The substantially enhanced toughness was interpreted in terms of the tetragonal to monoclinic martensitic phase transformability.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.JEURCERAMSOC.2011.02.002
|
“Method for the determination of Pd-catalyst residues in active pharmaceutical ingredients by means of high-energy polarized-beam energy dispersive X-ray fluorescence”. Marguí, E, van Meel K, Van Grieken R, Buendía A, Fontás C, Hidalgo M, Queralt I, Analytical chemistry 81, 1404 (2009). http://doi.org/10.1021/AC8021373
Abstract: In medicinal chemistry, Pd is perhaps the most-widely utilized precious metal, as catalyst in reactions which represent key transformations toward the synthesis of new active pharmaceutical ingredients (APIs). The disadvantage of this metal-catalyzed chemistry is that expensive and toxic metal residues are invariably left bound to the desired product. Thus, stringent regulatory guidelines exist for the amount of residual Pd that a drug candidate is allowed to contain. In this work, a rapid and simple method for the determination of Pd in API samples by high-energy polarized-beam energy dispersive X-ray fluorescence spectrometry has been developed and validated according to the specification limits of current legislation (10 mg kg−1 Pd) and the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH guidelines). Sample and calibration standards preparation includes a first step of homogenization and then, in a second step, the pressing of the powdered material into pellets without any chemical treatment. The use of several synthetic calibration standards made of cellulose to simulate the API matrix appears to be an effective means to obtain reliable calibration curves with a good spread of data points over the working range. With the use of the best measuring conditions, the limit of detection (0.11 mg kg−1 Pd) as well as the limit of quantitation (0.37 mg kg−1 Pd) achieved meet rigorous requirements. The repeatability of the XRF measurement appeared to be less than 2%, while the precision of the whole method was around 7%. Trueness was evaluated by analyzing spiked API samples at the level of the specification limit and calculating the recovery factor, which was better than 95%. To study the applicability of the developed methodology for the intended purpose, three batches of the studied API were analyzed for their Pd content, and the attained results were comparable to those obtained by the daily routine method (acid digestion plus atomic spectroscopy) used in most pharmaceutical laboratories.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1021/AC8021373
|
“Argentinean prehistoric pigments' study by combined SEM/EDX and molecular spectroscopy”. Darchuk L, Tsybrii Z, Worobiec A, Vázquez C, Palacios OM, Stefaniak EA, Gatto Rotondo G, Sizov F, Van Grieken R, Spectrochimica acta: part A: molecular and biomolecular spectroscopy 75, 1398 (2010). http://doi.org/10.1016/J.SAA.2010.01.006
Abstract: Composition of the prehistoric pigments (from Carriqueo rock shelter, Rio Negro province, Argentina) has been analysed by means of molecular spectroscopy (Fourier transform infrared (FTIR) and micro-Raman) and scanning electron microscopy (SEM) coupled to an energy-dispersive X-ray spectrometer (EDS). Red and yellow pigments were recognized as red and yellow ochre. The matrix of the pigments is composed of one or more substances. According to the matrix composition yellow and red pigments were also divided into two groupsi.e. those containing kaolinite or sulphates. Green pigment was detected as green earth, made up of celadonite as a chromophore.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
DOI: 10.1016/J.SAA.2010.01.006
|