“Microstructure and functional property changes in thin Ni-Ti wires heat teated by electric current: high energy X-ray and TEM investigations”. Malard B, Pilch J, Sittner P, Gartnerova V, Delville R, Schryvers D, Curfs C, Functional materials letters 2, 45 (2009). http://doi.org/10.1142/S1793604709000557
Abstract: High energy synchrotron X-ray diffraction, transmission electron microscopy and mechanical testing were employed to investigate the evolution of microstructure, texture and functional superelastic properties of 0.1 mm thin as drawn NiTi wires subjected to a nonconventional heat treatment by controlled electric current (FTMT-EC method). As drawn NiTi wires were prestrained in tension and exposed to a sequence of short DC power pulses in the millisecond range. The annealing time in the FTMT-EC processing can be very short but the temperature and force could be very high compared to the conventional heat treatment of SMAs. It is shown that the heavily strained, partially amorphous microstructure of the as drawn NiTi wire transforms under the effect of the DC pulse and tensile stress into a wide range of annealed nanosized microstructures depending on the pulse time. The functional superelastic properties and microstructures of the FTMT-EC treated NiTi wire are comparable to those observed in straight annealed wires.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 1.234
Times cited: 21
DOI: 10.1142/S1793604709000557
|
“Contact sponge method : performance of a promising tool for measuring the initial water absorption”. Vandevoorde D, Pamplona M, Schalm O, Vanhellemont Y, Cnudde V, Verhaeven E, Journal of cultural heritage 10, 41 (2009). http://doi.org/10.1016/J.CULHER.2008.10.002
Abstract: Porous limestone and mortar are able to absorb large quantities of water. This phenomenon will accelerate the deterioration of the material. In such cases, the material might be treated with a hydrophobic product, which creates a superficial layer that hampers the penetration of water. In order to decide if such a treatment should be applied or not, the water absorbing behaviour of the material should be measured. With the same measuring technique the efficiency of the hydrophobic barrier can be evaluated. Moreover, it allows the monitoring of such barriers as a function of time. At the same time, the water absorption of porous stone material is an indication of the degree of deterioration and its sensitivity to future deterioration. Up to now, two different measuring techniques exist, but one can only be used in laboratory and the other, which can be operated in laboratory as well as in situ, is not always reliable for in situ analyses. This article proposes an alternative method: the contact sponge method. This recently developed method was tested on non-treated porous stone materials in a laboratory environment in order to evaluate its performance in comparison with the two existing methods.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.CULHER.2008.10.002
|
“Adsorption of sulfur onto a surface of silver nanoparticles stabilized with sago starch biopolymer”. Djoković, V, Krsmanović, R, Božanić, DK, McPherson M, Van Tendeloo G, Nair PS, Georges MK, Radhakrishnan T, Colloids and surfaces: B : biointerfaces 73, 30 (2009). http://doi.org/10.1016/j.colsurfb.2009.04.022
Abstract: Adsorption of sulfide ions onto a surface of starch capped silver nanoparticles upon addition of thioacetamide was investigated. UVvis absorption spectroscopy revealed that the adsorption of the sulfide ion on the surface of the silver nanoparticles induced damping as well as blue shift of the silver surface plasmon resonance band. Further increase in thioacetamide concentration led to shift of the resonance band toward higher wavelengths indicating the formation of the continuous Ag2S layer on the silver surface. Thus fabricated nanoparticles were investigated using electron microscopy techniques (TEM, HRTEM, and HAADF-STEM) and X-ray photoelectron spectroscopy (XPS), which confirmed their coreshell structure.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 3.887
Times cited: 41
DOI: 10.1016/j.colsurfb.2009.04.022
|
“Formation of a combined micro- and mesoporous material using zeolite Beta nanoparticles”. van Oers CJ, Stevens WJJ, Bruijn E, Mertens M, Lebedev OI, Van Tendeloo G, Meynen V, Cool P, Microporous and mesoporous materials: zeolites, clays, carbons and related materials 120, 29 (2009). http://doi.org/10.1016/j.micromeso.2008.08.056
Abstract: Composite micro- and mesoporous materials are synthesized using zeolite Beta nanoparticles without the need for a structure directing agent to form the mesopores. This leads to important ecological and economical advantages. The influence of the way of cooling the aged nanoparticles solution on the formation of the composite materials has been studied. The materials have been characterized towards porosity by N2-sorption, towards zeolitic properties by TGA, DRIFT, XRD and TEM, towards aluminium content by EPMA. All prepared structures possess zeolitic properties. However, the method of cooling down of the aged seeds leads to differences in the porosity and intensity of the zeolitic characteristics.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Laboratory of adsorption and catalysis (LADCA)
Impact Factor: 3.615
Times cited: 42
DOI: 10.1016/j.micromeso.2008.08.056
|
“EPXMA survey of shelf sediments (Southern Bight, North Sea): a glance beyond the XRD-invisible”. de Maeyer-Worobiec A, Dekov VM, Laane RWPM, Van Grieken R, Microchemical journal 91, 21 (2009). http://doi.org/10.1016/J.MICROC.2008.07.001
Abstract: Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a reasonable analytical reliability. XRD studies of such a type of sediments with monotonous mineral composition are not able to provide mineralogical information beyond the main well-crystalline minerals and the mineralogical quantitative characteristic of the sediment based on XRD estimations are incorrect. The EPXMA mineralogical interpretations are based on the statistical evaluation of a huge data set (thousands of mineral particles) and provide a rather correct quantitative determination of the main minerals. The comparative EPXMAXRF study revealed that the Al, Si, K, Ca, Fe and to some extent Ti contents estimated by EPXMA are fairly reliable. In this respect the accuracy of the EPXMA-based mineral identification of the pure silicates, pure aluminosilicates, and Al-, Ca-, Fe- and Ti-containing minerals with simple composition is very high. Mg-calcite, augite and apatite determinations are assessed to be correct. The supposed accuracy of the clay mineral determinations is slightly lower (7080%) than that of the other main minerals due to the complex and varying composition of the clays. The identification of XRD-invisible accessory minerals and quantification of their presence in the sediments is an essential advantage of the EPXMA, which makes it a useful approach in tracing the origin of the sediments, the pathways of their transport and the geochemical processes they have undergone. However, the EPXMA has several flaws, which need to be solved in the future sediment investigations: (1) calibration with natural standards is needed in order to provide a higher accuracy of the mineral determinations; (2) any EPXMA study of sediments needs to be secured with XRF examinations of selected samples since EPXMA gives only semi-quantitative information about the abundance of the elements; (3) ultra-thin window EPXMA of low-Z elements has to be used since some of them (O, C) are always present in the main sediment components: silicates, aluminosilicates, carbonates and metal oxyhydroxides; (4) the interpretations of the clay fraction have to be supported with detailed XRD investigations of selected samples, while the mineralogy of the silt and sand fractions needs to be backed up with optical microscopy studies. The information from different analytical techniques (EPXMA with XRFXRD-optical microscopy of selected samples) combined with the knowledge about the most possible minerals in a given environment, would give the most reliable results in studying mineralogical composition of shelf sediments.
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.MICROC.2008.07.001
|
“Numerical study of the sputtering in a dc magnetron”. Kolev I, Bogaerts A, Journal of vacuum science and technology: A: vacuum surfaces and films 27, 20 (2009). http://doi.org/10.1021/jp8058992
Abstract: Molecular dynamics simulations were used to investigate the size-dependent melting mechanism of nickel nanoclusters of various sizes. The melting process was monitored by the caloric curve, the overall cluster Lindemann index, and the atomic Lindemann index. Size-dependent melting temperatures were determined, and the correct linear dependence on inverse diameter was recovered. We found that the melting mechanism gradually changes from dynamic coexistence melting to surface melting with increasing cluster size. These findings are of importance in better understanding carbon nanotube growth by catalytic chemical vapor deposition as the phase state of the catalyst nanoparticle codetermines the growth mechanism.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.536
Times cited: 66
DOI: 10.1021/jp8058992
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
“Description of the plasma chemistry in an atmospheric pressure CH4 dielectric barrier discharge using a two dimensional fluid model”. De Bie C, Martens T, van Dijk J, van der Mullen JJAM, Bogaerts A, , 13 (2009)
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“X ray fluorescence in member states: Belgium: integration of analysis techniques of different scales using X ray induced and electron induced X ray spectrometry for applications in preventive conservation and environmental monitoring”. Van Grieken R, Potgieter-Vermaak S, Darchuk L, Worobiec A, XRF newsletter , 9 (2009)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Computation and parametrization of the temperature dependence of Debye-Waller factors for group IV, III-V and II-VI semiconductors”. Schowalter M, Rosenauer A, Titantah JT, Lamoen D, Acta crystallographica: section A: foundations of crystallography 65, 5 (2009). http://doi.org/10.1107/S0108767308031437
Abstract: We calculated the temperature dependence of the Debye-Waller factors for a variety of group IV, III-V and II-VI semiconductors from 0.1 to 1000 K. The approach used to fit the temperature dependence is described and resulting fit parameters are tabulated for each material. The Debye-Waller factors are deduced from generalized phonon densities of states which were derived from first principles using the WIEN2k and the ABINIT codes.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT)
Impact Factor: 5.725
Times cited: 51
DOI: 10.1107/S0108767308031437
|
“Glow discharge optical spectroscopy and mass spectrometry”. Steiner RE, Barshick CM, Bogaerts A Wiley, Chichester, page 1 (2009).
Abstract: Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupolemass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (5001500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (e.g. Ar, Ne, and Xe) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. Unfortunately, the GD source functions optimally in a dry environment, making analysis of solutions more difficult. These sources also suffer from difficulties associated with analyzing nonconductingsamples. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This section focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GDsources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with avariety of spectroscopic and spectrometric instruments for both quantitative and qualitative analysis.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Tuning the superconducting properties of nanomaterials”. Croitoru MD, Shanenko AA, Peeters FM Springer, Dordrecht, page 1 (2009).
Abstract: Electron continement and its effect on the superconducting-to-normal phase transition driven by a magentic field and/or a current is studied in nanowires. Our investigation is based on a self-consistent numerical solution of the Bogoliubov-de Gennes equations. We find that in a parallel magneitc field and/or in the presence of a supercurrent the transition from the superconducting to the normal phase occurs as a cascade of discontinuous jumps in the superconducting order parameter for diameters D < 10 divided by 15 nm at T = 0. The critical magentic field exhibits quantum-size oscillations with pronounced resonant enhancements as a function of the wire radius.
Keywords: H1 Book chapter; Condensed Matter Theory (CMT); Electron microscopy for materials research (EMAT)
DOI: 10.1007/978-90-481-3120-4_1
|
“X-ray fluorescence analysis, sample preparation for”. Margu'i' E, Queralt I, Van Grieken R page 1 (2009).
Keywords: H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Characterization of nano-crystalline diamond films grown under continuous DC bias during plasma enhanced chemical vapor deposition”. Mortet V, Zhang L, Echert M, Soltani A, d' Haen J, Douheret O, Moreau M, Osswald S, Neyts E, Troadec D, Wagner P, Bogaerts A, Van Tendeloo G, Haenen K, Materials Research Society symposium proceedings (2009). http://doi.org/10.1557/PROC-1203-J05-03
Abstract: Nanocrystalline diamond films have generated much interested due to their diamond-like properties and low surface roughness. Several techniques have been used to obtain a high re-nucleation rate, such as hydrogen poor or high methane concentration plasmas. In this work, the properties of nano-diamond films grown on silicon substrates using a continuous DC bias voltage during the complete duration of growth are studied. Subsequently, the layers were characterised by several morphological, structural and optical techniques. Besides a thorough investigation of the surface structure, using SEM and AFM, special attention was paid to the bulk structure of the films. The application of FTIR, XRD, multi wavelength Raman spectroscopy, TEM and EELS yielded a detailed insight in important properties such as the amount of crystallinity, the hydrogen content and grain size. Although these films are smooth, they are under a considerable compressive stress. FTIR spectroscopy points to a high hydrogen content in the films, while Raman and EELS indicate a high concentration of sp2 carbon. TEM and EELS show that these films consist of diamond nano-grains mixed with an amorphous sp2 bonded carbon, these results are consistent with the XRD and UV Raman spectroscopy data.
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1557/PROC-1203-J05-03
|
“Cluster issue on plasma modelling”. van Dijk J, Kroesen GMW, Bogaerts A London (2009).
Keywords: ME3 Book as editor; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
“Allogeneic stromal cell implantation in brain tissue leads to robust microglial activation”. Tambuyzer BR, Bergwerf I, de Vocht N, Reekmans K, Daans J, Jorens PG, Goossens H, Ysebaert DK, Chatterjee S, Van Marck E, Berneman ZN, Ponsaerts P, Immunology and cell biology (2009). http://doi.org/10.1038/ICB.2009.12
Abstract: Although adult and embryonic stem cell-based therapy for central nervous system (CNS) injury is being developed worldwide, less attention is given to the immunological aspects of allogeneic cell implantation in the CNS. The latter is of major importance because, from a practical point of view, future stem cell-based therapy for CNS injury will likely be performed using well-characterised allogeneic stem cell populations. In this study, we aimed to further describe the immunological mechanism leading to rejection of allogeneic bone marrow-derived stromal cells (BM-SC) after implantation in murine CNS. For this, we first investigated the impact of autologous and allogeneic BM-SC on microglia activation in vitro. Although the results indicate that both autologous and allogeneic BM-SC do not activate microglia themselves in vitro, they also do not inhibit activation of microglia after exogenous stimuli in vitro. Next, we investigated the impact of allogeneic BM-SC on microglia activation in vivo. In contrast to the in vitro observations, microglia become highly activated in vivo after implantation of allogeneic BM-SC in the CNS of immune-competent mice. Moreover, our results suggest that microglia, rather than T-cells, are the major contributors to allograft rejection in the CNS.
Keywords: A1 Journal article; Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP); Bio-Imaging lab; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.557
Times cited: 31
DOI: 10.1038/ICB.2009.12
|
“Reporter gene-expressing bone marrow-derived stromal cells are immune-tolerated following implantation in the central nervous system of syngeneic immunocompetent mice”. Bergwerf I, de Vocht N, Tambuyzer B, Verschueren J, Reekmans K, Daans J, Ibrahimi A, Van Tendeloo V, Chatterjee S, Goossens H, Jorens PG, Baekelandt V, Ysebaert D, Van Marck E, Berneman ZN, Van Der Linden A, Ponsaerts P, BMC biotechnology (2009). http://doi.org/10.1186/1472-6750-9-1
Abstract: Background Cell transplantation is likely to become an important therapeutic tool for the treatment of various traumatic and ischemic injuries to the central nervous system (CNS). However, in many pre-clinical cell therapy studies, reporter gene-assisted imaging of cellular implants in the CNS and potential reporter gene and/or cell-based immunogenicity, still remain challenging research topics. Results In this study, we performed cell implantation experiments in the CNS of immunocompetent mice using autologous (syngeneic) luciferase-expressing bone marrow-derived stromal cells (BMSC-Luc) cultured from ROSA26-L-S-L-Luciferase transgenic mice, and BMSC-Luc genetically modified using a lentivirus encoding the enhanced green fluorescence protein (eGFP) and the puromycin resistance gene (Pac) (BMSC-Luc/eGFP/Pac). Both reporter gene-modified BMSC populations displayed high engraftment capacity in the CNS of immunocompetent mice, despite potential immunogenicity of introduced reporter proteins, as demonstrated by real-time bioluminescence imaging (BLI) and histological analysis at different time-points post-implantation. In contrast, both BMSC-Luc and BMSC-Luc/eGFP/Pac did not survive upon intramuscular cell implantation, as demonstrated by real-time BLI at different time-points post-implantation. In addition, ELISPOT analysis demonstrated the induction of IFN-ã-producing CD8+ T-cells upon intramuscular cell implantation, but not upon intracerebral cell implantation, indicating that BMSC-Luc and BMSC-Luc/eGFP/Pac are immune-tolerated in the CNS. However, in our experimental transplantation model, results also indicated that reporter gene-specific immune-reactive T-cell responses were not the main contributors to the immunological rejection of BMSC-Luc or BMSC-Luc/eGFP/Pac upon intramuscular cell implantation. Conclusion We here demonstrate that reporter gene-modified BMSC derived from ROSA26-L-S-L-Luciferase transgenic mice are immune-tolerated upon implantation in the CNS of syngeneic immunocompetent mice, providing a research model for studying survival and localisation of autologous BMSC implants in the CNS by real-time BLI and/or histological analysis in the absence of immunosuppressive therapy.
Keywords: A1 Journal article; Antwerp Surgical Training, Anatomy and Research Centre (ASTARC); Laboratory Experimental Medicine and Pediatrics (LEMP); Bio-Imaging lab; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.415
Times cited: 33
DOI: 10.1186/1472-6750-9-1
|
“Chemical characterization and source apportionment of fine aerosols”. Ravindra K, Stranger M, Van Grieken R, Sokhi RS (2009).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
Chou L, Harlay J, Roevros N, Lannuzel D, Rebreanu L, van der Zee C, Lapernat P-E, Daro M-H, Aerts K, Godoi R, Van Grieken R (2009) Role of oceanic production and dissolution of calcium carbonate in climate change (CCCC): final report
Keywords: Minutes and reports; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|