“Electrochemical fingerprint of street samples for fast on-site screening of cocaine in seized drug powders”. De Jong M, Sleegers N, Kim J, Van Durme F, Samyn N, Wang J, De Wael K, Chemical science , 1 (2016). http://doi.org/10.1039/C5SC04309C
Abstract: We report on a wearable fingertip sensor for on-the-spot identification of cocaine and its cutting agents in street samples. Traditionally, on-site screening is performed by means of colour tests which are difficult to interpret and lack selectivity. By presenting the distinct voltammetric response of cocaine, cutting agents, binary mixtures of cocaine and street samples in solution and powder street samples, we were able to elucidate the electrochemical fingerprint of all these compounds. The new electrochemical concept holds considerable promise as an on-site screening method.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 8.668
Times cited: 37
DOI: 10.1039/C5SC04309C
|
“Large-volume injection combined with gas chromatography/isotope ratio mass spectrometry for the analysis of polycyclic aromatic hydrocarbons”. Buczyńska AJ, Geypens B, Van Grieken R, De Wael K, Rapid communications in mass spectrometry 28, 1 (2014). http://doi.org/10.1002/RCM.6769
Abstract: RATIONALE: Compound-specific stable isotope analyses of carbon require relatively large amounts of sample for reliable analyses. Commonly applied injections of 1 μL may thus be inefficient for samples with low concentrations of pollutants (e.g. air particulate matter) or when the amount of a sample is limited. METHODS: A Large-Volume Injection (LVI) method for carbon stable isotope ratio analysis of Polycyclic Aromatic Hydrocarbons (PAHs) was optimized in this study. Gas chromatography/combustion/isotope ratio mass spectrometry (GCCIRMS) and ion trap mass spectrometry (ITMS) were used for the determination of stable carbon isotope ratios and quantification of compounds, respectively. RESULTS: The optimized method resulted in very good reproducibility, even for the most volatile PAH, naphthalene, when a small amount of higher boiling co-solvent was used. No significant fractionation of isotope ratios could be seen and the recoveries of analytes were similar to or better than that of a splitless cold injection. CONCLUSIONS: Injection of 100 μL, instead of the commonly used 1 μL, increases the detection limit for PAHs significantly and/or simplifies the sample preparation step. Using our optimized method, stable carbon isotope ratios can be reliably measured in samples with concentrations of PAHs down to 0.050.1 ng μL1.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.998
Times cited: 5
DOI: 10.1002/RCM.6769
|
“The use of lead dodecanoate as an environmentally friendly coating to inhibit the corrosion of lead objects : comparison of three different deposition methods”. De Keersmaecker M, De Wael K, Adriaens A, Progress in organic coatings 74, 1 (2012). http://doi.org/10.1016/J.PORGCOAT.2012.01.014
Abstract: An aqueous sodium dodecanoate solution has been used for the formation of a protective coating for lead. Three deposition methods have been compared: immobilization using cyclic voltammetry, immersion and amperometry. Apart from this, we tested a reduction pretreatment of the lead surface (−1.5 V during 600 s) in order to obtain a more reproducible coating, resulting in a better corrosion protection behavior. The corrosion inhibition properties were examined using potentiodynamic polarization curves and electrochemical impedance measurements in a standard corrosive environment.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.858
Times cited: 8
DOI: 10.1016/J.PORGCOAT.2012.01.014
|
“Assessing atmospheric dry deposition via water-soluble ionic composition of roadside leaves”. Kardel F, Wuyts K, De Wael K, Samson R, Journal of environmental science and health : part A: toxic/hazardous substances and environmental engineering , 1 (2020). http://doi.org/10.1080/10934529.2020.1752589
Abstract: This study focuses on the water-soluble ion concentrations in the washing solution of leaves of different roadside tree species at three sites in Iran to estimate the ionic composition of the dry deposition of ambient air particulates. All considered water-soluble ion concentrations were significantly higher next to the roads with high traffic density compared to the reference site with low traffic density. The PCA results showed that Ca2+, Mg2+, and originated mainly from traffic activities and geological sources, and Na+, Cl-, K+ and F- from sea salts. In addition to sea salt, K+ and F- were also originated from anthropogenic sources i.e. industrial activities, biomass burning and fluorite mining. Moreover, the concentration of the water-soluble ions depended on species and site. C. lawsoniana had significantly higher ion concentrations in its leaf washing solution compared to L. japonicum and P. brutia which indicates C. lawsoniana is the most suitable species for accumulating of atmospheric dry deposition. From our results, it can be concluded that sites with similar traffic density can have different particle loads and water-soluble ion species, and that concentrations in leaf-washing solutions depend on site conditions and species-specific leaf surface characteristics.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/10934529.2020.1752589
|
“Unlocking the full power of electrochemical fingerprinting for on-site sensing applications”. Moro G, Barich H, Driesen K, Montiel NF, Neven L, Mendonca CD, Thiruvottriyur Shanmugam S, Daems E, De Wael K, Analytical And Bioanalytical Chemistry , 1 (2020). http://doi.org/10.1007/S00216-020-02584-X
Abstract: Electrochemical sensing for the semi-quantitative detection of biomarkers, drugs, environmental contaminants, food additives, etc. shows promising results in point-of-care diagnostics and on-site monitoring. More specifically, electrochemical fingerprint (EF)-based sensing strategies are considered an inviting approach for the on-site detection of low molecular weight molecules. The fast growth of electrochemical sensors requires defining the concept of direct electrochemical fingerprinting in sensing. The EF can be defined as the unique electrochemical signal or pattern, mostly recorded by voltammetric techniques, specific for a certain molecule that can be used for its quantitative or semi-quantitative identification in a given analytical context with specified circumstances. The performance of EF-based sensors can be enhanced by considering multiple features of the signal (i.e., oxidation or reduction patterns), in combination with statistical data analysis or sample pretreatments or by including electrode surface modifiers to enrich the EF. In this manuscript, some examples of EF-based sensors, strategies to improve their performances, and open challenges are discussed to unlock the full power of electrochemical fingerprinting for on-site sensing applications.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.3
Times cited: 3
DOI: 10.1007/S00216-020-02584-X
|
“Design of smart nanoparticles for the electrochemical detection of 3,4-methylenedioxymethamphetamine to allow in field screening by law enforcement officers”. Truta FM, Cruz AG, Dragan A-M, Tertis M, Cowen T, Stefan M-G, Topala T, Slosse A, Piletska E, Van Durme F, Kiss B, De Wael K, Piletsky SA, Cristea C, Drug testing and analysis , 1 (2023). http://doi.org/10.1002/DTA.3605
Abstract: A portable and highly sensitive sensor was designed for the specific detection of 3,4-methyl-enedioxy-methamphetamine (MDMA), in a range of field-testing situations. The sensor can detect MDMA in street samples, even when other controlled substances drugs, or adulterants are present. In this work, we report for the first time a sensor using electroactive molecularly imprinted polymer nanoparticles computationally designed to recognize MDMA and then produced using solid phase synthesis. A composite comprising chitosan, reduced graphene oxide, and molecularly imprinted polymer nanoparticles synthesized for MDMA for the first time was immobilized on screen-printed carbon electrodes. The sensors displayed a satisfactory sensitivity (106.8 nA x mu M-1), limit of detection (1.6 nM; 0.31 ng/mL), and recoveries (92-99%). The accuracy of the results was confirmed through validation using Ultra-High Performance Liquid Chromatography coupled with tandem Mass Spectrometry (UPLC-MS/MS). This technology could be used in forensic analysis and make it possible to selectively detect MDMA in street samples. A highly sensitive and portable sensor has been developed to detect MDMA in street samples. It uses electroactive molecularly imprinted polymer nanoparticles computationally designed to recognize MDMA, which were immobilized on screen-printed carbon electrodes with chitosan and graphene. The sensor showed good sensitivity and satisfactory recoveries (92-99%), confirmed with UPLC-MS/MS validation. This technology has the potential to be used in forensic analysis.image
Keywords: A1 Journal article; Pharmacology. Therapy; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 2.9
DOI: 10.1002/DTA.3605
|
“Evaluation of an electrochemical sensor and comparison with spectroscopic approaches as used today in practice for harm reduction in a festival setting: a case study : analysis of 3,4-methylenedioxymethamphetamine samples”. Deconinck E, Polet MA, Canfyn M, Duchateau C, De Braekeleer K, Van Echelpoel R, De Wael K, Gremeaux L, Degreef M, Balcaen M, Drug testing and analysis , 1 (2023). http://doi.org/10.1002/DTA.3625
Abstract: More and more countries and organisations emphasise the value of harm reduction measures in the context of illicit drug use and abuse. One of these measures is drug checking, a preventive action that can represent a quick win by tailored consultation on the risks of substance use upon analytical screening of a submitted sample. Unlike drop-in centres that operate within a fixed setting, enabling drug checking in a harm reduction context at events requires portable, easy to use analytical approaches, operated by personnel with limited knowledge of analytical chemistry. In this case study, four different approaches were compared for the characterisation of 3,4-methylenedioxymethamphetamine samples and this in the way the approaches would be applied today in an event context. The four approaches are mid-infrared (MIR), near-infrared, and Raman spectroscopy, which are today used in drug checking context in Belgium, as well as an electrochemical sensor approach initially developed in the context of law enforcement at ports. The MIR and the electrochemical approach came out best, with the latter allowing for a direct straightforward analysis of the percentage 3,4-methylenedioxymethamphetamine (as base equivalent) in the samples. However, MIR has the advantage that, in a broader drug checking context, it allows to screen for several molecules and so is able to identify unexpected active components or at least the group to which such components belong. The latter is also an important advantage in the context of the growing emergence of new psychotropic substances. MIR, NIR, Raman spectroscopy, and an electrochemical sensor (Narcoreader (R)) for MDMA analysis were compared in a realistic harm reduction context. NIR and Raman failed in simple library approaches. MIR and Narcoreader (R) were preferred. MIR came out as first choice. MIR and Narcoreader (R) have complementary (dis)advantages and could be used in a two-step approach: MIR for screening and Narcoreader (R) for dosage/risk evaluation of MDMA samples.image
Keywords: A1 Journal article; Pharmacology. Therapy; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 2.9
DOI: 10.1002/DTA.3625
|
“Stories of the life of Saint George : materials and techniques from a Barbelli mural painting”. Menegaldo B, Aleccia D, Nuyts G, Amato A, Orsega EF, Moro G, Balliana E, De Wael K, Moretto LM, Beltran V, Studies in conservation , 1 (2023). http://doi.org/10.1080/00393630.2023.2262842
Abstract: Gian Giacomo Inchiocchio (1604-1656), better known as Barbelli, was one of the main exponents of Lombard painting of the seventeenth century. A large body of work is attributed to him, encompassing a wide range of drawings, murals, and oil paintings. However, despite his broad production, there are still many open questions regarding his painting techniques and materials. In this paper, a multi-analytical study of the cycle Stories of the life of Saint George that originally decorated the presbytery of the parish church of Casaletto Vaprio (Cremona, Italy) was performed, combining non-invasive techniques with the characterisation of selected micro samples. Results show that Barbelli used a very limited number of inorganic pigments, often mixing them together to create different colours and shades. Remains of caseinate and degradation products (i.e. weddellite and whewellite) related to the strappo intervention were also highlighted. The study helped to decipher the materials and technique of this painting, providing data that can be used as a reference to study his extensive production.
Keywords: A1 Journal article; Art; History; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
Impact Factor: 0.8
DOI: 10.1080/00393630.2023.2262842
|
“Voltammetric drug testing makes sense at the border”. Van Echelpoel R, De Wael K, Nature Reviews Chemistry , 1 (2024). http://doi.org/10.1038/S41570-023-00571-1
Abstract: The European BorderSens project leverages voltammetric sensors, developed with end-users' input, to rapidly and accurately detect illicit drugs. By embracing practicalities and validation, this technology has the potential to combat the illicit drug problem.
Keywords: A1 Journal article; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1038/S41570-023-00571-1
|
“Coupling of phthalocyanines with plasmonic gold nanoparticles by click chemistry for an enhanced singlet oxygen based photoelectrochemical sensing”. Khan SU, Matshitse R, Borah R, Nemakal M, Moiseeva EO, Dubinina TV, Nyokong T, Verbruggen SW, De Wael K, ChemElectroChem , 1 (2024). http://doi.org/10.1002/CELC.202300677
Abstract: Coupling photosensitizers (PSs) with plasmonic nanoparticles increases the photocatalytic activity of PSs as the localized surface plasmon resonance (LSPR) of plasmonic nanoparticles leads to extreme concentration of light in their vicinity known as the near-field enhancement effect. To realize this in a colloidal phase, efficient conjugation of the PS molecules with the plasmonic nanoparticle surface is critical. In this work, we demonstrate the coupling of phthalocyanine (Pc) molecules with gold nanoparticles (AuNPs) in the colloidal phase via click chemistry. This conjugated Pc-AuNPs colloidal system is shown to enhance the photocatalytic singlet oxygen (1O2) production over non-conjugated Pcs and hence improve the photoelectrochemical detection of phenols. The plasmonic enhancement of the 1O2 generation by Pcs was clearly elucidated by complementary experimental and computational classical electromagnetic models. The dependence of plasmonic enhancement on the spectral position of the excitation laser wavelength and the absorbance of the Pc molecules with respect to the wavelength specific near-field enhancement is clearly demonstrated. A high similar to 8 times enhancement is obtained with green laser (532 nm) at the LSPR due to the maximum near-field enhancement at the resonance wavelength. Zinc phthalocyanine is covalently linked to plasmonic AuNPs via click chemistry to investigate the synergistic effect that boosts the overall activity toward the detection of HQ under visible light illumination. The 1O2 quantum yield of ZnPc improved significantly after conjugating with AuNPs, resulting in enhanced photoelectrochemical activity. image
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)
Impact Factor: 4
DOI: 10.1002/CELC.202300677
|
Blust RJP, Dardenne F, De Wael K, Nagels L, Van Camp G (2013) Electrochemical aptasensors with a gelatin B matrix : EP13175128
Abstract: An aptamer-based electrochemical sensor, wherein said aptamer is covalently bonded to or chemisorbed on an electrode, said aptamer forming a robust complex with a target molecule and is encapsulated by a gelatin B matrix; a method of manufacturing an aptamer-based electrochemical sensor for determining a concentration of a target molecule comprising the steps of: selecting an aptamer to form a robust complex with a target molecule using the SELEX procedure; synthesizing said aptamer; adsorbing said aptamer on or covalently coupling said aptamer with an electrode; and providing a gelatin B matrix for said aptamer on said electrode thereby realising said aptamer-based potentiometric or amperometric sensor; and the use of the aptamer-based electrochemical sensor produced according to the above method for the electrochemical determination of a concentration of 15 the target molecule.
Keywords: Patent; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
De Wael K, Nagels L, Van Camp G (2013) Potentiometric sensors and method for measuring intermolecular interactions
Keywords: Patent; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Electrochemical Analysis of Speedball-like Polydrug Samples”. de Jong M, Florea A, Daems D, Van Loon J, Samyn N, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01097A
Abstract: Increasing global production, trafficking and consumption of drugs of abuse cause an emerging threat to people’s health and safety. Electrochemical approaches have proven to be useful for on-site analysis of drugs of abuse. However, few attention has been focused on the analysis of polydrug samples, despite these samples causing severe health concerns, certainly when stimulants and depressants are combined, as is the case for Speedball, a mixture of cocaine and heroin. In this work, we provide solutions for the selective detection of cocaine (stimulant) in polydrug samples adulterated with heroin and codeine (depressants). The presence of either one of these compounds in cocaine street samples leads to an overlap with the cocaine signal in square-wave voltammetry measurements at unmodified carbon screen-printed electrodes, leading to inconclusive screening results in the field. The provided solutions to this problem consist of two parallel approaches: (i) cathodic pretreatment of the carbon screen-printed electrode surface prior to measurement in both alkaline and neutral conditions; (ii) electropolymerization of orthophenylenediamine on graphene modified carbon screen-printed electrodes prior to measurement in neutral conditions. Both strategies allow simultaneous detection of cocaine and heroin in speedball samples as well as simultaneous detection of cocaine and codeine. Implementing these strategies in portable devices holds great potential for significantly improved accuracy of on-site cocaine screening in polydrug samples.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
Impact Factor: 4.2
DOI: 10.1039/D0AN01097A
|
“Do aptamers always bind? The need for a multifaceted analytical approach when demonstrating binding affinity between aptamer and low molecular weight compounds”. Bottari F, Daems E, de Vries A-M, Van Wielendaele P, Trashin S, Blust R, Sobott F, Madder A, Martins JC, De Wael K, Journal Of The American Chemical Society 142, jacs.0c08691 (2020). http://doi.org/10.1021/JACS.0C08691
Abstract: In this manuscript, we compare different analytical methodologies to validate or disprove the binding capabilities of aptamer sequences. This was prompted by the lack of a universally accepted and robust quality control protocol for the characterization of aptamer performances coupled with the observation of independent yet inconsistent data sets in the literature. As an example, we chose three aptamers with a reported affinity in the nanomolar range for ampicillin, a β-lactam antibiotic, used as biorecognition elements in several detection strategies described in the literature. Application of a well-known colorimetric assay based on aggregation of gold nanoparticles (AuNPs) yielded conflicting results with respect to the original report. Therefore, ampicillin binding was evaluated in solution using isothermal titration calorimetry (ITC), native nano-electrospray ionization mass spectrometry (native nESI-MS), and 1H-nuclear magnetic resonance spectroscopy (1H NMR). By coupling the thermodynamic data obtained with ITC with the structural information on the binding event given by native nESI-MS and 1H NMR we could verify that none of the ampicillin aptamers show any specific binding with their intended target. The effect of AuNPs on the binding event was studied by both ITC and 1H NMR, again without providing positive evidence of ampicillin binding. To validate the performance of our analytical approach, we investigated two well-characterized aptamers for cocaine/quinine (MN4), chosen for its nanomolar range affinity, and l-argininamide (1OLD) to show the versatility of our approach. The results clearly indicate the need for a multifaceted analytical approach, to unequivocally establish the actual detection potential and performance of aptamers aimed at small organic molecules.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Medical Biochemistry
Impact Factor: 15
DOI: 10.1021/JACS.0C08691
|
“Gold-sputtered microelectrodes with built-in gold reference and counter electrodes for electrochemical DNA detection”. Thiruvottriyur Shanmugam S, Trashin S, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01387K
Abstract: Gold-sputtered microelectrodes with built-in gold reference and counter electrodes represent a promising platform for the development of disposable DNA sensors. Pretreating gold electrode surfaces and immobilization of DNA thereon is commonly employed in biosensing applications. However, with no scientific or practical guidelines to prepare a DNA sensor using these miniature gold-sputtered microelectrodes, cleaning and immobilization steps need to be systematically optimized and updated. In this work, we present efficient cleaning and modification of miniaturized gold-sputtered microelectrodes with thiolated DNA probes for DNA detection. Additional discussions on subtleties and nuances involved at each stage of pretreating and modifying gold-sputtered microelectrodes are included to present a robust, well-founded protocol. It was evident that the insights on cleaning polycrystalline gold disk electrodes with a benchmark electrode surface for DNA sensors, cannot be transferred to clean these miniature gold-sputtered microelectrodes. Therefore, a comparison between five different cleaning protocols was made to find the optimal one for gold-sputtered microelectrodes. Additionally, two principally different immobilization techniques for gold-sputtered microelectrode modification with thiolated ssDNA were compared i.e., immobilization through passive chemisorption and potential perturbation were compared in terms of thiol-specific attachment and thiol-unspecific adsorption through nitrogenous bases. The hybridization performance of these prepared electrodes was characterized by their sensitive complementary DNA capturing ability, detected by a standard alkaline phosphatase assay. Immobilization through passive chemisorption proved to be efficient in capturing the complementary target DNA with a detection limit of 0.14 nM and sensitivity of 9.38 A M−1 cm2. In general, this work presents a comprehensive understanding of cleaning, modification and performance of gold-sputtered microelectrodes with built-in gold reference and counter electrodes for both fundamental investigations and practical DNA sensing applications.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.2
DOI: 10.1039/D0AN01387K
|
“Transposing testing from lab to on-site environment : a case of cocaine powder sampling”. Van Loon J, De Jong M, De Wael K, Du Bois E, (2020)
Abstract: This paper reports on the transition process to convert a specific lab technique to the on-site, real-life environment. Bringing a lab test to an on-site environment involves many difficulties regarding to the context, people skills and environmental support. Within this project, a case about sampling for an electrochemical measurement, was investigated as a basis to reason upon some general conclusions related to the process of transposing lab-tests to an on-site environment. The current lab test was analysed and compared with a focus group discussion with future users. Based on the findings, assumptions for the new sampling technique in the specific case were formulated. New low-tech methods to achieve the sampling were extensively tested and verified. Starting from this chosen case an argumentation was set up to generalise the conclusions, by reasoning on other cases of products that already passed this transition to the field. Based on a comparison, we could discuss that the selected parameters related to impact of the context environment, of the people that should handle the tests, related to the reasons for transposing the technology, and related to the technology that will be transposed to the on-site environment, were of importance of almost all cases and can therefore be considered as context-independent and related to the transfer to on-site testing.
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
|
“Wearable wristband-based electrochemical sensor for the detection of phenylalanine in biofluids”. Parrilla M, Vanhooydonck A, Watts R, De Wael K, Biosensors and bioelectronics 197 (2022). http://doi.org/10.1016/J.BIOS.2021.113764
Abstract: Wearable electrochemical sensors are driven by the user-friendly capability of on-site detection of key biomarkers for health management. Despite the advances in biomolecule monitoring such as glucose, still, several unmet clinical challenges need to be addressed. For example, patients suffering from phenylketonuria (PKU) should be able to monitor their phenylalanine (PHE) level in a rapid, decentralized, and affordable manner to avoid high levels of PHE in the body which can lead to a profound and irreversible mental disability. Herein, we report a wearable wristband electrochemical sensor for the monitoring of PHE tackling the necessity of controlling PHE levels in PHE hydroxylase deficiency patients. The proposed electrochemical sensor is based on a screen-printed electrode (SPE) modified with a membrane consisting of Nafion, to avoid interferences in biofluids. The membrane also consists of sodium 1,2-naphthoquinone-4-sulphonate for the in situ derivatization of PHE into an electroactive product, allowing its electrochemical oxidation at the surface of the SPE in alkaline conditions. Importantly, the electrochemical sensor is integrated into a wristband configuration to enhance user interaction and engage the patient with PHE self-monitoring. Besides, a paper-based sampling strategy is designed to alkalinize the real sample without the need for sample pretreatment, and thus simplify the analytical process. Finally, the wearable device is tested for the determination of PHE in saliva and blood serum. The proposed wristband-based sensor is expected to impact the PKU self-monitoring, facilitating the daily lives of PKU patients toward optimal therapy and disease management.
Keywords: A1 Journal article; Engineering sciences. Technology; Product development; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)
DOI: 10.1016/J.BIOS.2021.113764
|
“A practical guide to build a Raspberry Pi Pico based potentiostat for educational electrochemistry and electronic instrumentation”. Steijlen A, Docter M, Bastemeijer J, Topyla M, Moraczewska M, Hoekstra T, Parrilla M, De Wael K, Journal of chemical education (2024). http://doi.org/10.1021/ACS.JCHEMED.4C00624
Abstract: This manuscript presents the first practical guide to build a Raspberry Pi Pico based potentiostat for electrical and electrochemical instrumentation education. The circuit enables us to perform different types of voltammetry such as cyclic and square wave voltammetry. Voltammograms of paracetamol tablets in a neutral buffer solution were successfully recorded and compared to lab equipment. Thereafter, the effect of different scan rates and different concentrations was studied as a proof of concept. Furthermore, the experiments were expanded with measurements of other pharmaceutical tablets such as vitamin C. Over 80 nanobiology bachelor students successfully built their own potentiostat in an electronic instrumentation course. They validated their systems successfully with electrochemical experiments using paracetamol as a conventional pharmaceutical that can be performed in a classroom. The students acquired a valuable understanding of the electronic building blocks and system architecture within electrochemical instrumentation, equipping them with the requisite knowledge to effectively optimize instrumentation parameters in their future research work.
Keywords: A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab); Antwerp engineering, PhotoElectroChemistry & Sensing (A-PECS)
Impact Factor: 3
DOI: 10.1021/ACS.JCHEMED.4C00624
|