“Micro-structure of fullerites and high Tc superconductors”. Van Tendeloo G, Krekels T, Amelinckx S Granada, page 17 (1992).
Keywords: H3 Book chapter; Electron microscopy for materials research (EMAT)
|
“Microanalysis of individual silver halide microcrystals”. Wu S, van Daele A, Jacob W, Gijbels R, Verbeeck A, de Keyzer R, Scanning microscopy 7, 17 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 7
|
“Analytical capabilities of laboratory, benchtop and handheld X-ray fluorescence systems for detection of metals in aqueous samples pre-concentrated with solid-phase extraction disks”. Margui E, Hidalgo M, Queralt I, van Meel K, Fontas C, Spectrochimica acta: part B : atomic spectroscopy 67, 17 (2012). http://doi.org/10.1016/J.SAB.2011.12.004
Abstract: We aimed to achieve improved instrumental sensitivity and detection limits for the analysis of several elements (Cu, Ni, Zn, Pb and Cd) in aqueous samples with energy dispersive X-ray fluorescence spectrometry (EDXRF). The metals were pre-concentrated from aqueous solutions using commercially available organic-based solid-phase extraction (SPE) disks functionalized with iminodiacetate groups. These thin-layer organic materials provide an ideal support for XRF analysis. The elements were collected on the SPE extraction disks using a simple filtration procedure (starting with 1 L of aqueous sample) that allows direct XRF measurements to be performed in the field (in situ). We evaluated the analytical possibilities and drawbacks of using this pre-concentration procedure in combination with the following XRF configurations: a handheld unit, a benchtop EDXRF system and a high-energy polarized-beam EDXRF instrument (HE-P-EDXRF). Using the HE-P-EDXRF system, the detection limits for all metals were more than one order of magnitude lower than those attained using handheld and benchtop EDXRF instrumentation. For the detection of metal concentrations higher than similar to 20 mu g/L, however, handheld or benchtop systems remain a very good option due to their extreme simplicity of operation and low-cost, compact design. We demonstrate the application of these methodologies, using the three equipment systems, to the analysis of trace concentrations of metals in different types of aqueous samples, including tap water and waste water. (C) 2011 Elsevier B.V. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.SAB.2011.12.004
|
“Assessment of homogeneity of candidate reference material at the nanogram level and investigation on representativeness of single particle analysis using electron probe X-ray microanalysis”. Ro C-U, Hoornaert S, Van Grieken R page 17 (2002).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Characterization of individual estuarine and marine particles by LAMMA and EPXMA”. Wouters L, Bernard P, Van Grieken R, International journal of environmental analytical chemistry 34, 17 (1988). http://doi.org/10.1080/03067318808029918
Abstract: Laser microprobe mass analysis (LAMMA) was applied to particulate matter from the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not probe X-ray microanalysis (EPXMA). Geochemically relevant groups of particles had been identified by EPXMA and cluster analysis. For both locations, the most abundant ones appeared to be those rich in silicon and the alumino-silicates. Afterwards LAMMA was applied to obtain more information about the trace element composition and surface characteristics. The iron-rich phase appeared to contain significant amounts of heavy metals and of phosphate. Lead appeared to be associated in detectable amounts with alumino-silicates in the Scheldt but not with those in the Atlantic Ocean. Inferring information about the surface layer by LAMMA was not always unambiguous.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1080/03067318808029918
|
“The Möbius phenomenon in Generalized Möbius-Listing surfaces and bodies, and Arnold's Cat phenomenon”. Gielis J, Ricci PE, Tavkhelidze I, Advanced Studies : Euro-Tbilisi Mathematical Journal 14, 17 (2021). http://doi.org/10.3251/ASETMJ/1932200812
Abstract: Möbius bands have been studied extensively, mainly in topology. Generalized Möbius-Listing surfaces and bodies providing a full geometrical generalization, is a quite new field, motivated originally by solutions of boundary value problems. Analogous to cutting of the original Möbius band, for this class of surfaces and bodies, results have been obtained when cutting such bodies or surfaces. In general, cutting leads to interlinked and intertwined different surfaces or bodies, resulting in very complex systems. However, under certain conditions, the result of cutting can be a single surface or body, which reduces complexity considerably. Our research is motivated by this reduction of complexity. In the study of cutting Generalized Möbius-Listing bodies with polygons as cross section, the conditions under which a single body results, displaying the Möbius phenomenon of a one-sided body, have been determined for even and odd polygons. These conditions are based on congruence and rotational symmetry of the resulting cross sections after cutting, and on the knife cutting the origin. The Möbius phenomenon is important, since the process of cutting (or separation of zones in a GML body in general) then results in a single body, not in different, intertwined domains. In all previous works it was assumed that the cross section of the GML bodies is constant, but the main result of this paper is that it is sufficient that only one cross section on the whole GML structure meets the conditions for the Möbius phenomenon to occur. Several examples are given to illustrate this.
Keywords: A1 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
DOI: 10.3251/ASETMJ/1932200812
|
“The rise of thermophilic biotechnology for nitrogen removal”. Vandekerckhove TGL, Courtens ENP, Prat D, Boon N, Vlaeminck SE, , 17 p.
T2 (2016)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Single particle characterisation of inorganic and organic North Sea suspension”. Jambers W, Dekov V, Van Grieken R, Marine chemistry 67, 17 (1999). http://doi.org/10.1016/S0304-4203(99)00046-8
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0304-4203(99)00046-8
|
“Study of aluminium-exposed fish by scanning proton microprobe analysis”. Eeckhaoudt S, Van Grieken RE, Cholewa M, Legge GJF, Microchimica acta 122, 17 (1996). http://doi.org/10.1007/BF01252401
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1007/BF01252401
|
“Unique properties of core shell Ag@Au nanoparticles for the aptasensing of bacterial cells”. Hamidi-Asl E, Dardenne F, Pilehvar S, Blust R, De Wael K, Chemosensors 4, 16 (2016). http://doi.org/10.3390/CHEMOSENSORS4030016
Abstract: In this article, it is shown that the efficiency of an electrochemical aptasensing device is influenced by the use of different nanoparticles (NPs) such as gold nanoparticles (Au), silver nanoparticles (Ag), hollow gold nanospheres (HGN), hollow silver nanospheres (HSN), silvergold core shell (Ag@Au), goldsilver core shell (Au@Ag), and silvergold alloy nanoparticles (Ag/Au). Among these nanomaterials, Ag@Au core shell NPs are advantageous for aptasensing applications because the core improves the physical properties and the shell provides chemical stability and biocompatibility for the immobilization of aptamers. Self-assembly of the NPs on a cysteamine film at the surface of a carbon paste electrode is followed by the immobilization of thiolated aptamers at these nanoframes. The nanostructured (Ag@Au) aptadevice for Escherichia coli as a target shows four times better performance in comparison to the response obtained at an aptamer modified planar gold electrode. A comparison with other (core shell) NPs is performed by cyclic voltammetry and differential pulse voltammetry. Also, the selectivity of the aptasensor is investigated using other kinds of bacteria. The synthesized NPs and the morphology of the modified electrode are characterized by UV-Vis absorption spectroscopy, scanning electron microscopy, energy dispersive X-ray analysis, and electrochemical impedance spectroscopy.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 9
DOI: 10.3390/CHEMOSENSORS4030016
|
“Integration of a photocatalytic coating in a corona discharge unit for plasma assisted catalysis”. Van Wesenbeeck K, Hauchecorne B, Lenaerts S, Journal of environmental solutions 2, 16 (2013)
Abstract: The combination of a non-thermal plasma with catalysis is considered as a sustainable indoor air purification technology to achieve complete oxidation at reduced energy cost with a longer electrode lifetime. An optimal window of operation for plasma assisted catalysis is found by varying the polarity, the applied voltage, the relative humidity of the gas phase and the configuration of the plasma reactor. The results show that, in general, negative corona discharge can obtain higher nitric oxide (NO) conversion efficiencies compared to positive corona. It is also clear that at higher applied voltages, higher conversion efficiency can be reached. The effect of relative humidity, however, is not found to be significant in the range (0 20.3 %) tested in this work. Additionally, the configuration of the plasma reactor is changed by varying the amount of pins that are attached at the collector electrode. The results show that there is an optimum at 10 pairs of pins to obtain a high conversion efficiency of NO. By applying a coating on the collector electrode of the plasma reactor, it is possible to see the influence of the coating on the performance of the plasma system, which was operating in the previously found optimal window. It stands clear that the use of a plasma assisted catalysis system has high potential as an integrated and sustainable indoor air purification technology.
Keywords: A1 Journal article; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Conceptual framework for deammonification in a combined floc-granule system : impact of aeration control, external selector and bioaugmentation based on full-scale data from WWTP in Strass”. Van Winckel T, Al-Omari A, Takás I, Wett B, Bachmann B, Sturm B, Bott C, Vlaeminck SE, Murthy S, De Clippeleir H, , 16 p.
T2 (2017)
Keywords: P3 Proceeding; Engineering sciences. Technology; Sustainable Energy, Air and Water Technology (DuEL)
|
“Grazing-exit electron probe x-ray microanalysis of light elements in particles”. Spolnik Z, Tsuji K, Van Grieken R, X-ray spectrometry 33, 16 (2004). http://doi.org/10.1002/XRS.656
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/XRS.656
|
“Single-run ion chromatographic separation of inorganic and low-molecular-mass organic anions under isocratic elution: application to environmental samples”. Krata A, Kontozova-Deutsch V, Bencs L, Deutsch F, Van Grieken R, Talanta : the international journal of pure and applied analytical chemistry 79, 16 (2009). http://doi.org/10.1016/J.TALANTA.2009.02.044
Abstract: For the isocratic ion chromatography (IC) separation of low-molecular-mass organic acids and inorganic anions three different anion-exchange columns were studied: IonPac AS14 (9 ìm particle size), Allsep A-2 (7 ìm particle size), and IC SI-50 4E (5 ìm particle size). A complete baseline separation for all analyzed anions (i.e., F−, acetate, formate, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−) in one analytical cycle of shorter than 17 min was achieved on the IC SI-50 4E column, using an eluent mixture of 3.2 mM Na2CO3 and 1.0 mM NaHCO3 with a flow rate of 1.0 mL min−1. On the IonPac AS14 column, it was possible to separate acetate from inorganic anions in one run (i.e., less than 9 min), but not formate, under the following conditions: 3.5 mM Na2CO3 plus 1.0 mM NaHCO3 with a flow rate of 1.2 mL min−1. Therefore, it was necessary to adapt a second run with a 2.0 mM Na2B4O7 solution as an eluent under a flow rate of 0.8 mL min−1 for the separation of organic ions, which considerably enlarged the analysis time. For the Allsep A-2 column, using an eluent mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.6 mL min−1, it was possible to separate almost all anions in one run within 25 min, except the fluoride-acetate critical pair. A Certified Multianion Standard Solution PRIMUS for IC was used for the validation of the analytical methods. The lowest RSDs (less than 1%) and the best LODs (0.02, 0.2, 0.16, 0.11, 0.06, 0.05, 0.04, 0.14 and 0.09 mg L−1 for F−, Ac−, For−, Cl−, NO2−, Br−, NO3−, HPO42− and SO42−, respectively) were achieved using the IC SI-50 4E column. This column was applied for the separation of concerned ions in environmental precipitation samples such as snow, hail and rainwater.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2009.02.044
|
“State-of-the-art X-ray fluorescence instrumentation for chemical analysis”. Margui E, Van Grieken R, Petro Industry News , 16 (2013)
Abstract: Nowadays, X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis (sometimes from Be to U) of a wide variety of samples. In particular, the truly multi-element character, acceptable speed and economy, ease of automation and the possibility to directly analyse solid samples are the most important features among the many that have made it a very mature analytical tool for routine quality controls in many industries, as well as for analytical support for the research laboratory.e recent technological advances, including the design of low-power micro-focus tubes and the novel X-ray optics and detectors have made it possible to extend XRF to the determination of low-Z elements and to obtain 2D or 3D information on a micrometre-scale. Furthermore, the recent development and commercialisation of benchtop and portable instrumentation, that offer extreme simplicity of operation in a low-cost design, have promoted even more the approach of XRF for many analytical problems.is article highlights this state-of-the art technique with regards to currently available XRF instrumentation on the market as well as recent applications in environmental and industrial fields.
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Synchrotron light through ancient glass”. de Raedt I, Vekemans B, Janssens K, Adams F, Europhysics news 31, 15 (2000)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Populieren en hun bacteriën : een sanering hoeft niet altijd duur en ingrijpend te zijn”. Compernolle T, Van Passel S, Lebbe L, Vangronsveld J, Thewys T, Nieuwsbrief milieu &, economie 24, 15 (2010)
Keywords: A3 Journal article; Economics
|
“Materiaaltransfer van de oceaan naar de atmosfeer”. Van Grieken R, Mededelingen en informatie , 15 (1976)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Effect of mismatched electron-hole effective masses on superfluidity in double layer solid-state systems”. Conti S, Perali A, Peeters FM, Neilson D, Condensed Matter 6, 14 (2021). http://doi.org/10.3390/CONDMAT6020014
Abstract: Superfluidity has been predicted and now observed in a number of different electron-hole double-layer semiconductor heterostructures. In some of the heterostructures, such as GaAs and Ge-Si electron-hole double quantum wells, there is a strong mismatch between the electron and hole effective masses. We systematically investigate the sensitivity to unequal masses of the superfluid properties and the self-consistent screening of the electron-hole pairing interaction. We find that the superfluid properties are insensitive to mass imbalance in the low density BEC regime of strongly-coupled boson-like electron-hole pairs. At higher densities, in the BEC-BCS crossover regime of fermionic pairs, we find that mass imbalance between electrons and holes weakens the superfluidity and expands the density range for the BEC-BCS crossover regime. This permits screening to kill the superfluid at a lower density than for equal masses.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Times cited: 1
DOI: 10.3390/CONDMAT6020014
|
“The analysis of volatile siloxanes in waste activated sludge”. Dewil R, Appels L, Baeyens J, Van Vaeck L, Buczyńska A, Talanta 74, 14 (2007). http://doi.org/10.1016/J.TALANTA.2007.05.041
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/J.TALANTA.2007.05.041
|
“De kleine boerderij : twee bijzondere tuinkamers”. Vermander C, De Wael J, Gielis J, Groencontact 45, 14 (2019)
Keywords: A2 Journal article; Sustainable Energy, Air and Water Technology (DuEL)
|
“Modification of the multislice method for calculating coherent STEM images”. Chen JH, van Dyck D, op de Beeck M, Broeckx J, van Landuyt J, Physica status solidi: A: applied research 150, 13 (1995). http://doi.org/10.1002/pssa.2211500103
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Vision lab
Times cited: 5
DOI: 10.1002/pssa.2211500103
|
“Confocal micro-XRF study of element distribution of a uranium enriched tertiary sediment”. Janssens K, Denecke M, Rothe J, Simon R page 13 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Examination of historical paintings by state-of-the-art hyperspectral imaging methods : from scanning infra-red spectroscopy to computed X-ray laminography”. Legrand S, Vanmeert F, van der Snickt G, Alfeld M, de Nolf W, Dik J, Janssens K, Heritage science 2, 13 (2014). http://doi.org/10.1186/2050-7445-2-13
Abstract: The development of advanced methods for non-destructive selective imaging of painted works of art at the macroscopic level based on radiation in the X-ray and infrared range of the electromagnetic spectrum are concisely reviewed. Such methods allow to either record depth-selective, element-selective or species-selective images of entire paintings. Camera-based full field methods (that record the image data in parallel) can be discerned next to scanning methods (that build up distributions in a sequential manner by scanning a beam of radiation over the surface of an artefact). Six methods are discussed: on the one hand, macroscopic X-ray fluorescence and X-ray diffraction imaging and X-ray laminography and on the other hand macroscopic Mid and Near Infrared hyper- and full spectral imaging and Optical Coherence Tomography. These methods can be considered to be improved versions of the well-established imaging methods employed worldwide for examination of paintings, i.e., X-ray radiography and Infrared reflectography. Possibilities and limitations of these new imaging techniques are outlined.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1186/2050-7445-2-13
|
“Synchroton X-ray powder diffraction study of lead white oxidation by sodium hypochloride”. Clerici EA, De Meyer S, van der Snickt G, Janssens K, , 13 (2017)
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Un verre méditerranéen pour la production de bracelets laténiens en Europe septentrionale : résultats danalyses SEM-EDX et LA-ICP-MS de bracelets en verre La Tène tardive de Odijk, Tiel et Geldermalseren-Hondsgemet”. Cosyns P, Cagno S, Janssens K, Nys K, Bulletin AFAV , 13 (2014)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“XRS activities at the Micro &, Trace Analysis Centre (MiTAC), University of Antwerp, Belgium”. Padilla R, Janssens K, van Espen P, Van Grieken R, IAEA XRF newsletter 12, 13 (2006)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
“Characterization of air pollutants observed in three European cathedrals: is the protective glazing really effective?”.Kontozova V, Godoi RHM, Spolnik Z, Worobiec A, Deutsch F, Van Grieken R, Rivista della Stazione sperimentale del vetro 3, 13 (2005)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP)
|
“Compositional correlation between pigments found in excavations and on human bones investigated with micro-raman spectrometry and scanning electron microscopy”. Vázquez C, Darchuk L, Stefaniak EA, Van Grieken R, Palacios OR page 13 (2011).
Keywords: H2 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
“Corrosive marine atmosphere investigations in Tanzania: exposure sites and preliminary results”. Mmari AG, Potgieter-Vermaak SS, Uiso CBS, Makundi IN, Potgieter JH, Van Grieken R, Newsletter of the International Global Atmospheric Chemistry Project , 13 (2007)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|